A Near-Infrared Spectrometer to Measure Zodiacal Light Absorption Spectrum

We have developed a high throughput infrared spectrometer for zodiacal light fraunhofer lines measurements. The instrument is based on a cryogenic dual silicon Fabry-Perot etalon which is designed to achieve high signal to noise Fraunhofer line profile measurements. Very large aperture silicon Fabry-Perot etalons and fast camera optics make these measurements possible. The results of the absorption line profile measurements will provide a model free measure of the zodiacal Light intensity in the near infrared. The knowledge of the zodiacal light brightness is crucial for accurate subtraction of zodiacal light foreground for accurate measure of the extragalactic background light after the subtraction of zodiacal light foreground. We present the final design of the instrument and the first results of its performance.

Kutyrev, A. S.↗

Multilayer Monochromator For Hard X Rays And Gamma Rays

Compact monochromator for hard x rays and gamma rays provides high spectral resolution with high throughput. Resembles instruments in "Compact X-Ray and Extreme-Ultraviolet Monochromator" (MFS-28499), "Scanning X-Ray or Extreme-Ultraviolet Monochromator" (MFS-28492), "Ultra-High-Spectral-Resolution X-Ray/EUV Monochromator" (MFS-28500), and "Four-Mirror X-Ray and Extreme-Ultraviolet Monochromator" (MFS-28498). Operates on principle of multilayer Bragg reflector. Used in nuclear, astronomical, and biomedical research, x-ray crystallography, research on processing materials, research in x-ray lasers, and x-ray lithography.

Hoover, Richard B.↗

POINTS (Precision Optical INTerferometer in Space)

POINTS is a high-precision, high-throughput interferometer intended for astromomy only. It can perform science compatable with astrophysics (AIM) and planet detection (TOPS-1). The spacecraft will be compact, lightweight, and suitable for high Earth orbit. It will employ the minimal number and complexity of mechanisms or deployable parts and be designed for a 10 year mission life.

interferometer astronomy satellite↗

Application of holographic optical techniques to bulk memory.

Current efforts to exploit the spatial redundancy and built-in imaging of holographic optical techniques to provide high information densities without critical alignment and tight mechanical tolerances are reviewed. Read-write-erase in situ operation is possible but is presently impractical because of limitations in available recording media. As these are overcome, it should prove feasible to build holographic bulk memories with mechanically replaceable hologram plates featuring very fast (less than 2 microsec) random access to large (greater than 100 million bit) data blocks and very high throughput (greater than 500 Mbit/sec). Using volume holographic storage it may eventually be possible to realize random-access mass memories which require no mechanical motion and yet provide very high capacity.

Anderson, L. K.↗

Transcriptomics-based Machine Learning (ML) Analysis Predicts Space-Exposed Murine Livers

NASA has employed high-throughput molecular assays to identify sub-cellular changes impacting human physiology during spaceflight. Machine learning (ML) methods hold the promise to improve our ability to identify important signals within highly dimensional molecular data. However, the inherent limitation of study subject numbers within a spaceflight mission minimizes the utility of ML approaches. To overcome the sample power limitations, data from multiple spaceflight missions must be aggregated while appropriately addressing intra- and inter-study variabilities. Here we describe an approach to log transform, scale and normalize data from six heterogeneous, mouse liver derived transcriptomics datasets (ntotal=137) which enabled ML-methods to perform well (AUC ≥ 0.87) in classifying spaceflown vs ground control animals rather than mission-of-origin. Concordance was found between liver-specific biological processes identified from harmonized ML-based analysis and study-by-study classical omics analysis. This work demonstrates the feasibility of applying ML methods on integrated, heterogeneous datasets of small sample size.

Machine Learning↗

A Miniature Solid-State Spectrometer for Space Applications: Field Tests

A solid state infrared spectrometer has been developed under the Planetary Instrument Definition and Development Program PIDDP to implement a small rugged spectrometer principally for landed applications. The instrument uses the high index of refraction and waveguide properties of a silicon slab to achieve good spectral resolution and high throughput in a small instrument footprint (less than 25 cm). Light enters the silicon slab and is reflected off a grating (Ebert configuration), utilizing the silicon index of refraction to achieve high dispersion. An array of microthermopiles is used to measure the amplitude of the dispersed light. Input optics are typically utilized to focus light on the input aperture and a chopper is used to compensate system drift.

Smythe, W. D.↗

Design, Implementation, and Verification of the Reliable Multicast Protocol

This document describes the Reliable Multicast Protocol (RMP) design, first implementation, and formal verification. RMP provides a totally ordered, reliable, atomic multicast service on top of an unreliable multicast datagram service. RMP is fully and symmetrically distributed so that no site bears an undue portion of the communications load. RMP provides a wide range of guarantees, from unreliable delivery to totally ordered delivery, to K-resilient, majority resilient, and totally resilient atomic delivery. These guarantees are selectable on a per message basis. RMP provides many communication options, including virtual synchrony, a publisher/subscriber model of message delivery, a client/server model of delivery, mutually exclusive handlers for messages, and mutually exclusive locks. It has been commonly believed that total ordering of messages can only be achieved at great performance expense. RMP discounts this. The first implementation of RMP has been shown to provide high throughput performance on Local Area Networks (LAN). For two or more destinations a single LAN, RMP provides higher throughput than any other protocol that does not use multicast or broadcast technology. The design, implementation, and verification activities of RMP have occurred concurrently. This has allowed the verification to maintain a high fidelity between design model, implementation model, and the verification model. The restrictions of implementation have influenced the design earlier than in normal sequential approaches. The protocol as a whole has matured smoother by the inclusion of several different perspectives into the product development.

Montgomery, Todd L.↗

Fast, High-Precision Readout Circuit for Detector Arrays

The GEO-CAPE mission described in NASA's Earth Science and Applications Decadal Survey requires high spatial, temporal, and spectral resolution measurements to monitor and characterize the rapidly changing chemistry of the troposphere over North and South Americas. High-frame-rate focal plane arrays (FPAs) with many pixels are needed to enable such measurements. A high-throughput digital detector readout integrated circuit (ROIC) that meets the GEO-CAPE FPA needs has been developed, fabricated, and tested. The ROIC is based on an innovative charge integrating, fast, high-precision analog-to-digital circuit that is built into each pixel. The 128×128-pixel ROIC digitizes all 16,384 pixels simultaneously at frame rates up to 16 kHz to provide a completely digital output on a single integrated circuit at an unprecedented rate of 262 million pixels per second. The approach eliminates the need for off focal plane electronics, greatly reducing volume, mass, and power compared to conventional FPA implementations. A focal plane based on this ROIC will require less than 2 W of power on a 1×1-cm integrated circuit. The ROIC is fabricated of silicon using CMOS technology. It is designed to be indium bump bonded to a variety of detector materials including silicon PIN diodes, indium antimonide (InSb), indium gallium arsenide (In- GaAs), and mercury cadmium telluride (HgCdTe) detector arrays to provide coverage over a broad spectral range in the infrared, visible, and ultraviolet spectral ranges.

Rider, David M.↗

Creating Benchmark Data for Artificial Intelligence and Machine Learning Space Biology Research

To identify an appropriate AI/ML approach for a specific problem, the best practice is to measure algorithm performance through the benchmarking process. A scientific benchmark consists of an AI-ready dataset and a reference implementation on a specific scientific question. The NASA Science Mission Directorate (SMD) has started the “Benchmark Initiative for AI/ML to create scientific benchmark datasets in three applications: 1) scientific benchmarking, which finds the best algorithm for a specific problem; 2) application benchmarking, which measures algorithm performance against a set of parameters; and 3) system benchmarking, which evaluates performance of hardware and software architecture. Currently, there are no standardized datasets available to benchmark AI/ML algorithms in the domain of space biology. In this work, we constructed two AI/ML-ready biological datasets from experiments in space-flown mice: cellular imaging and RNA-seq. First, radiation-exposed immune cells harbor DNA damage foci that can be fluorescently marked to visualize the amount of damage following exposure to ionizing radiation. However, such large datasets are difficult to analyze visually, due to imaging inconsistencies and human bias, and classical image processing approaches can fail on imaging artifacts. AI/ML are therefore exciting alternative, providing the speed of machines and the accuracy of humans. We have made this dataset available at https://registry.opendata.aws/bps_microscopy/. Second, high-throughput nucleic acid sequencing (DNA-seq, RNA-seq) has become widespread in biomedical research due to the growing availability and affordability of these assays. However, most sequencing datasets suffer from high dimensionality and low sample count. In this work, we used a generative adversarial network to synthesize a standardized, AI-ready, publicly available benchmark dataset for space biology RNA-seq data with sufficient space-flown and ground control mouse liver samples from NASA GeneLab. This dataset is available at https://registry.opendata.aws/bps_rnaseq/. These datasets are now fully open the Space Biology community to test their favorite AI/ML approaches.

James Casaletto↗

In-Situ Heat Rejection to the Martian Atmosphere

In order to provide in-situ heat rejection to the thin Martian atmosphere, approaches relying on forced convection and buoyancy flow are conceptualized. A convective radiator concept utilizing a fan to draw local atmosphere through an expanded metal foam heat exchanger panel is developed. To provide a pumped fluid loop interface, flow tubes are embedded in the heat exchanger panel and heat is transferred from the tubes to the foam via conduction and subsequently convectively to the environment. To forgo the use of a specialized high throughput fan, a concept utilizing a buoyant chimney tower to draw atmospheric flow through a low pressure drop heat exchanger is also considered. Both concepts may best align with moderate- to high-temperature heat loads that provide a significant delta temperature relative to the ambient atmosphere temperature. While eliminating dust accumulation on radiator surfaces, some type of serviceable filtration or screening may be required to prevent accumulation of dust inside the expanded metal foam heat exchanger for both concepts.

Heat Rejection↗

Remotely Controlled Mixers for Light Microscopy Module (LMM) Colloid Samples

Developed by NASA Glenn Research Center, the LMM aboard the International Space Station (ISS) is enabling multiple biomedical science experiments. Techshot, Inc., has developed a series of colloid specialty cell systems (C-SPECS) for use in the colloid science experiment module on the LMM. These low-volume mixing devices will enable uniform particle density and remotely controlled repetition of LMM colloid experiments. By automating the experiment process, C-SPECS allow colloid samples to be processed more quickly. In addition, C-SPECS will minimize the time the crew will need to spend on colloid experiments as well as eliminate the need for multiple and costly colloid samples, which are expended after a single examination. This high-throughput capability will lead to more efficient and productive use of the LMM. As commercial launch vehicles begin routine visits to the ISS, C-SPECS could become a significant means to process larger quantities of high-value materials for commercial customers.

Kurk, Michael A. (Andy)↗

Lunar UV-visible-IR mapping interferometric spectrometer

Ultraviolet-visible-infrared mapping digital array scanned interferometers for lunar compositional surveys was developed. The research has defined a no-moving-parts, low-weight and low-power, high-throughput, and electronically adaptable digital array scanned interferometer that achieves measurement objectives encompassing and improving upon all the requirements defined by the LEXSWIG for lunar mineralogical investigation. In addition, LUMIS provides a new, important, ultraviolet spectral mapping, high-spatial-resolution line scan camera, and multispectral camera capabilities. An instrument configuration optimized for spectral mapping and imaging of the lunar surface and provide spectral results in support of the instrument design are described.

Smith, W. Hayden↗

Variability in Galactic Cosmic Radiation- Induced DNA Damage Response in Inbred Mice Is Modulated by Genetics

In radiation biology, the ability to predict cancer risk associated with exposure to low doses of high-LET (Linear Energy Transfer) ionizing radiation remains a challenge. Epidemiological methods lack the sensitivity and power to provide detailed risk estimates for cancer and ignore individual sensitivity. We have hypothesized that DNA repair capacity is the primary factor differentiating peoples radiation sensitivity. We previously showed in immortalized human cell lines that characterizing the dose and time dependence of p53-binding protein 1 (53BP1) foci formation in the nucleus following X-rays exposure is sufficient to predict DNA repair response to any other LET in the same cell line. We now tested this hypothesis across a population of mice with different genetic background. Fibroblast cells were extracted and cultivated from 76 individual mice from 15 different strains and exposed to HZE (high (H) atomic number (Z) and energy (E) galactic cosmic ray particles) particles and X-rays. Individual radiation sensitivities were investigated by high throughput measurement of DNA repair kinetics that evaluated 53bp1 foci numbers as a surrogate for DNA double-strand breaks at various times post-irradiation. Instead of just counting foci which can be hard to distinguish for high-LET or high doses, we also took into account the track structure of high-LET particles to compute the remaining number of unrepaired tracks as a function of time post-irradiation. As expected, the percentage of unrepaired track over a 48 hours follow-up period increased with LET. In addition, repair rate was modulated by genetics, with animals from the same strain showing small variance while large rate differences were observed between strains. Radiation strain sensitivity ranking was estimated based on repair rates from exposure to each LET evaluated in this work, and ranking for high-LET correlated better with ranking from high dose of X-ray, not low dose. At the in-vivo level, drops in T-cells and B-cells number measured 24 hours after 0.1 Gy (Gray) X-ray exposure, correlated with slower DNA repair kinetic in fibroblast cells of the same strains of mice. At the genomic level, mouse genome wide association (GWA) analysis identified seven significant genetic loci on chromosomes 2, 3, 7, 10, 11, 13 and 19 with different significance depending on the LET. Interestingly, for the two highest LET, a common locus on Chromosome 10 was identified with high enrichment for DNA repair associated genes.Overall, this work suggests that repair kinetics of primary skin fibroblasts is a good surrogate marker for in-vivo radiation sensitivities in other tissues and that this response is modulated by genetics. Our study also confirms that DNA repair kinetics following high doses of X-ray can be used to predict radiation sensitivity to high-LET.

High-LET Radiation↗

Neurovascular effects of simulated space radiation

A major health risk for human deep space exploration is central nervous system (CNS) damage by ionizing radiation. Simulated galactic cosmic rays or their components, especially high-linear energy transfer particles such as 56Fe ions, have been shown to cause CNS damage, neuroinflammation and cognitive dysfunction in rodent models, but their effects on human CNS remain to be investigated. CNS damage from any insult, including ionizing radiation, is partially mediated by the blood-brain barrier (BBB), which regulates interactions between CNS and the rest of the body. Astrocytes are major cellular regulators of BBB permeability and also modulate neuroinflammation and neurodegeneration. However, BBB and astrocyte functions in regulating CNS responses to space radiation remain little investigated, especially in human organ analogs. Therefore, we developed and utilized a high-throughput 3D human neurovascular organ-on-a-chip model, seeded with induced pluripotent stem cell-derived cells. The effects of time course, ionizing radiation dose and dose rate were mapped by exposing the model to either acute, high dose rate radiation with simulated galactic cosmic rays or 600 MeV/n 56Fe particles, or protracted, low dose rate gamma radiation using a 57Co sealed source setup. We investigated BBB permeability, oxidative stress, cellular damage and secreted factors over the time period between 24 hours – 2 weeks after 0.1 – 0.8 Gy irradiation. We observed that ionizing radiation exposure increased BBB permeability, caused oxidative stress, damaged endothelial cells and altered expression of inflammatory cytokines with a subset of outcomes dependent on ionizing radiation dose rate. Furthermore, our results indicated that astrocyte functions were primarily deleterious at early time points and protective later after irradiation, resembling CNS responses to injury in vivo. Our findings in organ models were complemented by studies on true spaceflight using mouse spatial and single cell multi-omics, which similarly indicated spaceflight-mediated changes in astrocyte functions. In summary, our study evaluates the regulation of neurovascular responses to simulated space radiation, suggesting astrocytes as targets for countermeasures to mitigate CNS damage in deep space exploration.

Radiation↗

Potential for improved silicon ribbon growth through thermal environment control

The Ribbon-to-Ribbon (RTR) process for growth of silicon ribbon is described. This process involves the fabrication of a microcrystalline ribbon of silicon and subsequent grain size enhancement through a laser recrystallization process. The microribbon is obtained from a Thermal Expansion Shear Separation (TESS) process which allows a CVD layer of silicon to be separated from a temporary molybdenum substrate. Efforts to achieve increased solar cell efficiencies and higher area production rates have been problematical. Furnaces, which are necessary for thermal stress control, have been shown to contribute contamination to substrates resulting in degraded efficiencies. Recent results with a new furnace design indicate efficiencies in excess of 9% will be routine. Limitations to area throughput arise due to fundamental linear velocity limitations and width limitations necessary to prevent the occurrence of thermal buckling. Calculations are reported which show the influence of thermal profile on buckling tendencies, and a proposed electron beam technique is considered which promises high throughput with minimal buckling.

Gurtler, R. W.↗

GeneLab for High Schools – Bioinformatic Training For Students And Educators

Modern biological sciences are increasingly based on high-throughput molecular techniques, including genomics, transcriptomics, and proteomics. NASA’s GeneLab program has collected extensive data from ‘omics’ studies, curated them into an accessible platform and provided data analysis/visualization tools to facilitate the generation of new hypotheses and research directions. GeneLab for High Schools (GL4HS), launched in 2017, has endeavored to utilize this database and provide tools for students to understand and analyze omics datasets whilst also learning about spaceflight research. The GL4HS program ran in person at Ames from 2017-2019 and has run virtually since 2020. Each year fifteen high school students are trained to analyze and interpret GeneLab transcriptomic data. Additionally, in the last several years we have expanded our “teacher training program” to include 10 teachers total in an effort to enable this program to be utilized in classrooms across the USA. Teachers also join the NASA GeneLab Education Working Group (EWG) enabling support as they implement custom GL4HS modules into their classrooms. The GL4HS program consists of three main components – (1) core learning modules, (2) networking and teamwork, and (3) an independent learning project. Students are also taught critical networking and science communication skills facilitating their ability to ‘sell their science’ in innovative and creative ways. This program has enabled students to learn about biology in space and to have a glimpse into the world of research for the first time. Many of the students in this program shared that the course was transformative to their perception about biological sciences and how it linked to other areas of STEM. The ultimate and long-term goal of GL4HS is to expand the program to multiple locations thereby facilitating the reach of NASA Space Biology beyond NASA-centric regions.

GeneLab↗

Space Biotech: Hindsight, Insight, Foresight

Over the past forty years, microgravity has inspired and enabled applications in a wide range of sectors including medicine, materials, computers, communications, and national defense. Trends show that demand for high-tech solutions is increasing in these sectors, solutions that require higher resolution, greater precision, novel materials, innovative processes, and more sophisticated tools. These are areas where microgravity can offer unique capabilities for innovation. The Emerging Space Office (ESO) has engaged in multiple studies over the past year that have found that microgravity RD is one of the most promising technology areas for contributing to economic growth and to NASAs mission. The focus of these studies was on terrestrial markets rather than NASA applications, applied research rather than basic research, and commercial rather than academic investigators. There have been more success stories than are generally appreciated and there are significant areas of promising future potential. Many of the problems that have limited commercial microgravity development in the past are being solved. Microgravity research and development (RD) requires iteration and learning, as rapidly as possible. New technologies enable high throughput and rapid data collection in increasingly small payloads. The International Space Station is in orbit and provides a laboratory that is available 247 at least until 2024. Frequent flights by commercial space providers to and from the ISS now enable the fast learning cycles needed by high-tech industries. Launch costs are decreasing and the ability to return payloads to Earth is increasing. New commercial space laboratories, such as those being developed by SpaceX and Bigelow Aerospace, are in the final stages of development and testing. This ecosystem for microgravity RD has never been available before. These are game-changer conditions for attracting high-tech industries to space for terrestrial, as well as NASA, applications. However, few know that these capabilities are available or how to use them. In aggregate, the potential value for new applications from microgravity RD over the next ten years could add billions of dollars per year in terrestrial applications to the future economy, create new jobs, and generate a wide range of public benefits in medical advances, while broadening the customer base for the emerging space industry.

biotech↗

Modular, Fast, Two-Dimensional Cyclic Convolver

Proposed high-throughput, real-time synthetic-aperture-radar (SAR) processor built using new, modular, two-dimensional cyclic convolver architecture based on polynomial factorization and designed for very-large-scale integrated (VLSI) circuitry. New architecture reduces cost, size, and power dissipation of SAR processor in comparison to high-speed array-processor approach. Processor also used for other image-and data-processing applications involving two-dimensional Fourier transforms.