Search NASA⌕ Search

SEARCH · Search NASA

Results for “High-throughput sample processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

High-Throughput Open-Air Plasma Activation of Metal-Oxide Thin Films with Low Thermal Budget

Sputter-processed oxide films are usually annealed at high temperature (activation process) to achieve stable electrical characteristics through the formation of strong metal-oxide chemical bonds. For instance, indium– gallium–zinc oxide (IGZO) films typically need a thermal treatment at 300 °C for ≥1 h as an activation process. We introduce an open-air plasma treatment (OPT) to rapidly and effectively activate sputter-processed IGZO films. The OPT effectively induces metal-oxide chemical bonds in IGZO films at temperatures as low as 240 °C, with a dwell time on the order of a second. Furthermore, by controlling the plasma-processing conditions (scan speed, distance α between plasma nozzle and samples, and gas flow rate), the electrical characteristics and the microstructure of the IGZO films can be easily tuned. Finally, OPT can be utilized to implement a selective activation process. Plasma-treated IGZO thin-film transistors (TFTs) display comparable electrical characteristics to those of conventionally thermal treated IGZO TFTs. Through in-depth optical, chemical, and physical characterizations, we validate that OPT simultaneously dissociates weak chemical bonds by UV radiation and ion bombardment and reestablishes the metal-oxide network by radical reaction and OPT-induced heat.

36 MATERIALS SCIENCE↗

Chemiluminescent Biosensors for Detection of Second Messenger Cyclic di-GMP

Bacteria colonize highly diverse and complex environments, from gastrointestinal tracts to soil and plant surfaces. This colonization process is controlled in part by the intracellular signal cyclic di-GMP, which regulates bacterial motility and biofilm formation. To interrogate cyclic di-GMP signaling networks, a variety of fluorescent biosensors for live cell imaging of cyclic di-GMP have been developed. However, the need for external illumination precludes the use of these tools for imaging bacteria in their natural environments, including in deep tissues of whole organisms and in samples that are highly autofluorescent or photosensitive. The need for genetic encoding also complicates the analysis of clinical isolates and environmental samples. Toward expanding the study of bacterial signaling to these systems, we have developed the first chemiluminescent biosensors for cyclic di-GMP. The biosensor design combines the complementation of split luciferase (CSL) and bioluminescence resonance energy transfer (BRET) approaches. Furthermore, we developed a lysate-based assay for biosensor activity that enabled reliable high-throughput screening of a phylogenetic library of 92 biosensor variants. The screen identified biosensors with very large signal changes (~40- and 90-fold) as well as biosensors with high affinities for cyclic di-GMP ($K_D$ < 50 nM). These chemiluminescent biosensors then were applied to measure cyclic di-GMP levels in $E. coli$. The cellular experiments revealed an unexpected challenge for chemiluminescent imaging in Gram negative bacteria but showed promising application in lysates. Taken together, this work establishes the first chemiluminescent biosensors for studying cyclic di-GMP signaling and provides a foundation for using these biosensors in more complex systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uncertainty-Aware Machine Learning for Small-Angle X-ray Scattering Analysis in Autonomous Experimentation

Small-angle X-ray scattering (SAXS) is a powerful high-throughput characterization tool for probing nanoscale structure in native sample environments, providing real-time morphological information such as nanoparticle size and shape during synthesis. However, automated SAXS data analysis for extracting meaningful structural parameters is non-trivial and remains a bottleneck in closed-loop experimentation towards autonomous materials discovery, which demands fast, reliable, and uncertainty-aware data analysis. Here, we develop a machine-learning approach for automated SAXS analysis tailored to closed-loop nanoparticle synthesis. A Random Forest (RF) regression model is trained on 100,000 synthetic SAXS curves generated from polydisperse spherical nanoparticles with realistic background contributions. Using normalized one-dimensional SAXS intensity profiles as input, the RF model directly predicts nanoparticle radius, size polydispersity, and background parameters, while the ensemble standard deviation across trees provides built-in uncertainty quantification (UQ). On synthetic data, we show that combining fit-quality metrics (R 2 , MAE) with thresholds on prediction uncertainty reliably identifies accurate parameter estimates without access to ground truth. We then apply the trained model to 365 experimental SAXS profiles of citrate-reduced gold nanoparticles synthesized using an automated droplet-flow microreactor with in situ SAXS at a synchrotron beamline, classifying the results into high- and low-confidence subsets based on UQ metrics. Finally, we integrate RF-based SAXS analysis into a simulated closed-loop optimization campaign using Gaussian process Bayesian optimization to minimize nanoparticle polydispersity, benchmarking against conventional automated Levenberg–Marquardt fitting. The RF-guided campaign exhibits substantially faster convergence and lower relative opportunity cost (∼0.07 vs ∼0.3), demonstrating that uncertainty-aware machine-learning SAXS analysis significantly enhances the efficiency and robustness of autonomous nanomaterials synthesis workflows.

Bayesian optimization↗

High-throughput and high-efficiency sample preparation for single-cell proteomics using a nested nanowell chip

Abstract Global quantification of protein abundances in single cells could provide direct information on cellular phenotypes and complement transcriptomics measurements. However, single-cell proteomics is still immature and confronts many technical challenges. Herein we describe a nested nanoPOTS (N2) chip to improve protein recovery, operation robustness, and processing throughput for isobaric-labeling-based scProteomics workflow. The N2 chip reduces reaction volume to <30 nL and increases capacity to >240 single cells on a single microchip. The tandem mass tag (TMT) pooling step is simplified by adding a microliter droplet on the nested nanowells to combine labeled single-cell samples. In the analysis of ~100 individual cells from three different cell lines, we demonstrate that the N2 chip-based scProteomics platform can robustly quantify ~1500 proteins and reveal membrane protein markers. Our analyses also reveal low protein abundance variations, suggesting the single-cell proteome profiles are highly stable for the cells cultured under identical conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Inverse design of photonic surfaces via multi fidelity ensemble framework and femtosecond laser processing

We demonstrate a multi-fidelity (MF) machine learning ensemble framework for the inverse design of photonic surfaces, trained on a dataset of 11,759 samples that we fabricate using high throughput femtosecond laser processing. The MF ensemble combines an initial low fidelity model for generating design solutions, with a high fidelity model that refines these solutions through local optimization. The combined MF ensemble can generate multiple disparate sets of laser-processing parameters that can each produce the same target input spectral emissivity with high accuracy (root mean squared errors < 2%). SHapley Additive exPlanations analysis shows transparent model interpretability of the complex relationship between laser parameters and spectral emissivity. Finally, the MF ensemble is experimentally validated by fabricating and evaluating photonic surface designs that it generates for improved efficiency energy harvesting devices. Our approach provides a powerful tool for advancing the inverse design of photonic surfaces in energy harvesting applications.

97 MATHEMATICS AND COMPUTING↗

The evolution of analytical techniques for multiplex analysis of protein biomarkers

Introduction: The landscape of biomarker development has evolved with advanced analytical technologies, particularly affinity- and mass spectrometry-based techniques. These advancements have deepened our understanding of disease mechanisms, enabling the development of precise diagnostic tools and personalized medicine. Protein biomarkers, which play pivotal roles in biological processes, have become invaluable in diagnosing and monitoring diseases, aided by their presence in various biological samples and the availability of established detection methods. Areas covered: This review covers the role of protein biomarkers in clinical practice, the development and dimensionality of protein biomarkers, advancements in detection technologies, a comparison of these technologies, and future directions in biomarker discovery and disease mechanism elucidation. Expert opinion: Advances in biomarker technologies have the potential to transform diagnostics and personalized treatment but face challenges such as high costs and technical complexity. Enhancing reproducibility and integrating multi-omics approaches may offer better insights. In conclusion, the field should evolve toward high-throughput, automated methods, continuously adapting research, and clinical practices.

59 BASIC BIOLOGICAL SCIENCES↗

Genomic reconstruction of Bacillus anthracis from complex environmental samples enables high-throughput identification and lineage assignment in Pakistan

Bacillus anthracis, the causative agent of anthrax, is a highly virulent zoonotic pathogen primarily affecting domesticated and wild herbivores. Human exposure to B. anthracis is primarily through contact with infected animals or contaminated animal products. In Pakistan, where livestock vaccines are largely unavailable and infected carcasses are often disposed of improperly, the risk to humans, wildlife and livestock is significant. Currently, the diagnosis of anthrax infections and outbreak tracing necessitates the isolation and culturing of B. anthracis, a process that requires BSL-3 facilities. In this study, we show that positive identification, genome reconstruction and lineage assignment can be accomplished using bioinformatic analysis of DNA extracted directly from environmental samples that would otherwise provide the starting material for isolation and culturing. This approach does not require laboratory target enrichment as is necessary for other pathogens, due in part to the extremely high bacterial load in the bloodstream in the deceased animals. Using these methods, we greatly expand the knowledge of endemic B. anthracis in Pakistan. We provide the first reference B. anthracis genomes from Pakistan since the 1970s and identify A.Br.014 Aust94 as a minor circulating sublineage alongside the dominant A.Br.047 Vollum. Future work will focus on the limits of detection and will determine if this bioinformatic method can be expanded more broadly for B. anthracis or other pathogens to replace typical culture-based methods.

A.Br.047 Vollum↗

Evaluation of an event-driven 3FI ASIC for spectroscopic X-ray detection with synchrotron radiation

The novel design and evaluation on the NSLS-II beamline of the 3FI application-specific integrated circuit (ASIC) bump-bonded to a simple, planar, 2D segmented silicon sensor are presented. The ASIC was developed for full-field fluorescence spectral X-ray imaging (3FI). It is a small-scale prototype that features a square array of 32 × 32 pixels, and the size of the pixels is 100 µm × 100 µm. The ASIC was implemented in a 65 nm CMOS integrated circuit fabrication process. Each pixel incorporates a charge-sensitive amplifier, a shaping filter, a discriminator, a peak detector and a sample-and-hold circuit, allowing detection of events and storage of signal amplitudes. The system operates in a frameless event-driven readout mode, outputting analog values for threshold-triggered events, allowing high-speed multi-element X-ray fluorescence data acquisition. The 3FI ASIC achieves per-channel spectrometric performance at a power consumption of only 200 µW per pixel, with nearly all dissipation confined to the analog front-end. An energy resolution is measured at the level of 308 eV full width at half-maximum (FWHM) at 8.04 keV (Cu Kα), and 138 eV FWHM at 3.69 keV (Ca Kα). This per-pixel capability makes the prototype suitable for in situ trace element microanalysis in biological and environmental studies. Moreover, the frameless architecture of the detector is designed to address limitations of conventional X-ray fluorescence microscopy, which typically requires mechanical scanning, by enabling continuous high-throughput data acquisition in future full-field implementations.

47 OTHER INSTRUMENTATION↗

NACHOS, a CubeSat-based high-resolution UV-Visible hyperspectral imager for remote sensing of trace gases: system overview and science objectives

Here, the Nano-satellite Atmospheric Chemistry Hyperspectral Observation System (NACHOS) is a high-throughput (f/2.9), high spectral resolution (~1.3 nm optical resolution, 0.6 nm sampling) Offner-design hyperspectral imager operating in the 300-500 nm spectral region. The 1.5U instrument payload (1U optical system, 0.5U electronics module) is hosted by a 1.5U LANL-designed CubeSat bus to comprise a 3U complete satellite. Spectroscopically similar to NASA’s Ozone Monitoring Instrument (OMI), which provides wide-field global mapping of ozone and other gases at coarse spatial resolution, NACHOS fills the complementary niche of targeted measurements at much higher spatial resolution. With 350 across-track spatial pixels and a 15-degree across-track field of view, NACHOS will provide spectral imaging at roughly 0.4 km per pixel from 500 km altitude. NACHOS incorporates highly streamlined gas-retrieval algorithms for rapid onboard processing, alleviating the need to routinely downlink massive hyperspectral data cubes. We will discuss the instrument design, challenges in achieving mechanical robustness to launch vibration in such a compact instrument, the onboard calibration system, and gas-retrieval data downlink strategy. We will also discuss potential science missions, including monitoring of NO 2 as an easily detected proxy for anthropogenic fossil-fuel greenhouse gases, monitoring lowlevel SO 2 degassing at pre-eruptive volcanoes, H 2 CO from wildfires, and characterization of aerosols. The long-term vision is for a many-satellite constellation that could provide both high spatial resolution and frequent revisits for selected targets of interest. As an initial technology demonstration of this vision, the NACHOS project is currently slated to launch two CubeSats in early 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Novel laser-processed CsI:Tl detector for SPECT

Purpose: The aim of this work is to demonstrate the feasibility of a novel technique for fabrication of high spatial resolution CsI:Tl scintillation detectors for single photon emission computed tomography systems. Methods: The scintillators are fabricated using laser-induced optical barriers technique to create optical microstructures (or optical barriers) inside the CsI:Tl crystal bulk. The laser-processed CsI:Tl crystals are 3, 5, and 10 mm in thickness. In this work, the authors focus on the simplest pattern of optical barriers in that the barriers are created in the crystal bulk to form pixel-like patterns resembling mechanically pixelated scintillators. The monolithic CsI:Tl scintillator samples are fabricated with optical barrier patterns with 1.0 × 1.0 mm{sup 2} and 0.625 × 0.625 mm{sup 2} pixels. Experiments were conducted to characterize the fabricated arrays in terms of pixel separation and energy resolution. A 4 × 4 array of multipixel photon counter was used to collect the scintillation light in all the experiments. Results: The process yield for fabricating the CsI:Tl arrays is 100% with processing time under 50 min. From the flood maps of the fabricated detectors exposed to 122 keV gammas, peak-to-valley (P/V) ratios of greater than 2.3 are calculated. The P/V values suggest that regardless of the crystal thickness, the pixels can be resolved. Conclusions: The results suggest that optical barriers can be considered as a robust alternative to mechanically pixelated arrays and can provide high spatial resolution while maintaining the sensitivity in a high-throughput and cost-effective manner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanoimprinted superlattice metallic photonic crystal as ultraselective solar absorber

Here, a two-dimensional superlattice metallic photonic crystal (PhC) and its fabrication by nanoimprint lithography on tantalum substrates are presented. The superior tailoring capacity of the superlattice PhC geometry is used to achieve spectrally selective solar absorption optimized for high-temperature and high-efficiency solar-energy-conversion applications. The scalable fabrication route by nanoimprint lithography allows for a high-throughput and high-resolution replication of this complex pattern over large areas. Despite the high fill factor, the pattern of polygonal cavities is accurately replicated into a resist that hardens under ultraviolet radiation over an area of 10 mm 2 . In this way, cavities of 905 nm and 340 nm width are achieved with a period of 1 μm. After pattern transfer into tantalum via a deep reactive ion-etching process, the achieved cavities are 2.2 μm deep, separated by 85–95 nm wide ridges with vertical sidewalls. The room-temperature reflectance spectra of the fabricated samples show excellent agreement with simulated results, with a high spectral absorptance approaching blackbody absorption in the range from 300 to 1900 nm and a steep cutoff. The calculated solar absorptivity of this superlattice PhC is 96% and its thermal transfer efficiency is 82.8% at an operating temperature of 1500 K and an irradiance of 1000 kW/m 2 .

14 SOLAR ENERGY↗

Ambient Ion Trapping and Separations for High Throughput Structurally Selective Material Deposition

While ion mobility coupled to mass spectrometry (IMS/MS) has been increasingly adapted to biological analysis, the structural and molecular specificity offered by IMS/MS has untapped potential for creating novel materials (for energy, catalysis, biomolecular switches etc.) with rationally tailored properties by precisely controlling the chemical structure and composition of these materials. While electrochemical and catalytic properties of the bulk material are understood by mass-selective ion-soft-landing, different structures of one molecule can exhibit distinct properties from the bulk. Many biological phenomenon occur at interfaces and are highly structurally specific. IMS/MS offers means to separate molecules in a sample (which is first ionized and released to gas phase from the condensed phase) based on mass and structure. Species thus separated can potentially be deposited onto surfaces with molecular and structural specificity, to perform fundamental investigations for understanding critical interfacial phenomenon. Key performance metrics for IMS/MS analysis are resolution of separations and sensitivity. Recently developed Structures for Lossless Ion Manipulations (SLIM)4 enabled unprecedented resolution in IMS separations. In addition, high sensitivity was enabled in SLIM due to lossless confinement of ions using radio frequency fields. Thus, SLIM enabled extremely long path length separations (up to 0.1 km thus far) providing efficient separation of molecular ions never before achieved (e.g. isotopologues, D&L amino acids). While SLIM has unprecedented analytical separations power/utility, the use of SLIM platform for depositing mobility and mass selected molecular ions has two specific technological challenges: (a) Pulsed nature of IMS separations and their low duty cycle and (b) the need for a low vacuum of ~4 torr for lossless ion confinement. These limitations lead to long deposition times due to loss of ions generated from the sample. Enabling ion confinement at atmospheric pressure will be path-breaking contribution to the fundamental understanding of ion manipulations and separations and will also enable novel science currently precluded due to the inability of the present technologies to confine ions under ambient conditions. Traditionally used radio frequency fields are ineffective in confining ions at high pressures due to ion/neutral collisions. To address these, we propose to (a) develop methods for confining and manipulating ions for lossless IMS separations at atmospheric pressure enabling high sensitivity and throughput and (b) use the high specificity of IMS/MS and high throughput from ambient ion confinement to perform mobility and mass selective ion deposition at atmospheric pressure. Our goal is to enable the study of the fundamental properties of energy/catalysis materials and biomolecules. This project paves the way for high-throughput, mass and structure selective material deposition for highly specific surface creation/functionalization (discussed in Section 2 of the report). Further, the developments reported continue to push the boundaries of this process to ambient conditions (discussed in Section 3 of the report). We conclude with a list of specific intellectual property and publications which have been the outcome of this funded project.

36 MATERIALS SCIENCE↗

Fine-scale evaluation of two standard 16S rRNA gene amplicon primer pairs for analysis of total prokaryotes and archaeal nitrifiers in differently managed soils

The advance of high-throughput molecular biology tools allows in-depth profiling of microbial communities in soils, which possess a high diversity of prokaryotic microorganisms. Amplicon-based sequencing of 16S rRNA genes is the most common approach to studying the richness and composition of soil prokaryotes. To reliably detect different taxonomic lineages of microorganisms in a single soil sample, an adequate pipeline including DNA isolation, primer selection, PCR amplification, library preparation, DNA sequencing, and bioinformatic post-processing is required. Besides DNA sequencing quality and depth, the selection of PCR primers and PCR amplification reactions arguably have the largest influence on the results. This study tested the performance and potential bias of two primer pairs, i.e., 515F (Parada)-806R (Apprill) and 515F (Parada)-926R (Quince) in the standard pipelines of 16S rRNA gene Illumina amplicon sequencing protocol developed by the Earth Microbiome Project (EMP), against shotgun metagenome-based 16S rRNA gene reads. The evaluation was conducted using five differently managed soils. We observed a higher richness of soil total prokaryotes by using reverse primer 806R compared to 926R, contradicting to in silico evaluation results. Both primer pairs revealed various degrees of taxon-specific bias compared to metagenome-derived 16S rRNA gene reads. Nonetheless, we found consistent patterns of microbial community variation associated with different land uses, irrespective of primers used. Total microbial communities, as well as ammonia oxidizing archaea (AOA), the predominant ammonia oxidizers in these soils, shifted along with increased soil pH due to agricultural management. In the unmanaged low pH plot abundance of AOA was dominated by the acid-tolerant NS-Gamma clade, whereas limed agricultural plots were dominated by neutral-alkaliphilic NS-Delta/NS-Alpha clades. This study stresses how primer selection influences community composition and highlights the importance of primer selection for comparative and integrative studies, and that conclusions must be drawn with caution if data from different sequencing pipelines are to be compared.

16S rRNA gene amplicon Illumina sequencing↗

A novel statistical methodology for quantifying the spatial arrangements of axons in peripheral nerves

A thorough understanding of the neuroanatomy of peripheral nerves is required for a better insight into their function and the development of neuromodulation tools and strategies. In biophysical modeling, it is commonly assumed that the complex spatial arrangement of myelinated and unmyelinated axons in peripheral nerves is random, however, in reality the axonal organization is inhomogeneous and anisotropic. Present quantitative neuroanatomy methods analyze peripheral nerves in terms of the number of axons and the morphometric characteristics of the axons, such as area and diameter. In this study, we employed spatial statistics and point process models to describe the spatial arrangement of axons and Sinkhorn distances to compute the similarities between these arrangements (in terms of first- and second-order statistics) in various vagus and pelvic nerve cross-sections. We utilized high-resolution transmission electron microscopy (TEM) images that have been segmented using a custom-built high-throughput deep learning system based on a highly modified U-Net architecture. Our findings show a novel and innovative approach to quantifying similarities between spatial point patterns using metrics derived from the solution to the optimal transport problem. We also present a generalizable pipeline for quantitative analysis of peripheral nerve architecture. Our data demonstrate differences between male- and female-originating samples and similarities between the pelvic and abdominal vagus nerves.

59 BASIC BIOLOGICAL SCIENCES↗

A Portable Miniature Cryogenic Environment for In Situ Neutron Diffraction

Neutron diffraction instruments offer a platform for materials science and engineering studies at extended temperature ranges far from ambient. As one of the widely used neutron sample environment types, cryogenic furnaces are usually bulky and complex, and they may need hours of beamtime overhead for installation, configuration, cooling, and sample change, etc. To reduce the overhead time and expedite experiments at the state-of-the-art high-flux neutron source, we developed a low-cost, miniature, and easy-to-use cryogenic environment (77–473 K) for in situ neutron diffraction. A travel-size mug serves for the environment where the samples sit inside. Immediate cooling and an isothermal dwell at 77 K are realized on the sample by direct contact with liquid N 2 in the mug. The designed Al inserts serve as the holder of samples and heating elements, alleviate the thermal gradient, and clear neutron pathways. Both a single-sample continuous measurement and multi-sample high-throughput measurements are demonstrated in this environment. High-quality and refinable in situ neutron diffraction patterns are acquired on model materials. The results quantify the orthorhombic-to-cubic phase transformation process in LiMn 2 O 4 and differentiate the anisotropic lattice thermal expansions and bond length evolutions between rhombohedral perovskite oxides with composition variation.

47 OTHER INSTRUMENTATION↗

Use of High-Throughput Automated Microbioreactor System for Production of Model IgG1 in CHO Cells

Automated microscale bioreactors (15 mL) can be a useful tool for cell culture engineers. They facilitate the simultaneous execution of a wide variety of experimental conditions while minimizing potential process variability. Applications of this approach include: clone screening, temperature and pH shifts, media and supplement optimization. Furthermore, the small reactor volumes are conducive to large Design of Experiments that investigate a wide range of conditions. This allows upstream processes to be significantly optimized before scale-up where experimentation is more limited in scope due to time and economic constraints. Automated microscale bioreactor systems offer various advantages over traditional small scale cell culture units, such as shake flasks or spinner flasks. However, during pilot scale process development significant care must be taken to ensure that these advantages are realized. When run with care, the system can enable high level automation, can be programmed to run DOE's with a higher number of variables and can reduce sampling time when integrated with a nutrient analyzer or cell counter. Integration of the expert-derived heuristics presented here, with current automated microscale bioreactor experiments can minimize common pitfalls that hinder meaningful results. In the extreme, failure to adhere to the principles laid out here can lead to equipment damage that requires expensive repairs. Furthermore, the microbioreactor systems have small culture volumes making characterization of cell culture conditions difficult. The number and amount of samples taken in-process in batch mode culture is limited as operating volumes cannot fall below 10 mL. This method will discuss the benefits and drawbacks of microscale bioreactor systems.

59 BASIC BIOLOGICAL SCIENCES↗

Large-scale continuous carbon/glass fiber additive-compression molded composites

Additive Manufacturing (AM) or 3-D printing has advanced from small-scale desktop printers to large-scale printers. Most of the present large-scale printers utilize feedstock materials in the form of pellets to create composite structures. To create structurally robust composite parts, reinforcements in the form of short fibers (carbon or glass) are often used to impart mechanical properties to the printed parts. However, poor mechanical properties in Z-direction and high porosity of pellets-based printed composites compared to composite manufactured using traditional methods are serious concerns. The authors report a combined approach in the present work, where fiber reinforced composites are printed with a high-throughput continuous fiber deposition method followed by a secondary compression molding process. A specially designed end-effector mounted on a robotic arm is used to print composite preforms. Continuous comingled fibers (Thermofiber 12K CF-PA12, Thermofiber 12K S2-PA12, and Hybrid Thermofiber 12K CF-PA12+PEEK PA6) embedded in the thermoplastic nylon matrix are printed to create composite preform plaques. The printed preforms were further compression molded (CM) using a hydraulic hot-press to create highly consolidated composite parts. The mechanical properties of the continuous fiber composites produced by this combined approach are improved significantly due to the highly aligned continuous fibers and reduced porosity. Flexural strength, flexural modulus, and tensile modulus of AM-CM Thermofiber 12K CF-PA12 UD sample were 615.37 MPa, 75.65 GPa, and 122.23 GPa, respectively.

Kumar, Vipin↗