At least 163 records · Page 9

International Space Station Environmental Control and Life Support System Acceptance Testing for Node 1 Temperature and Humidity Control Subsystem

The International Space Station (ISS) Node 1 Environmental Control and Life Support (ECLS) System is comprised of five subsystems: Atmosphere Control and Storage (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). This paper will provide a summary of the Node 1 ECLS THC subsystem design and a detailed discussion of the ISS ECLS Acceptance Testing methodology utilized for this subsystem.The International Space Station (ISS) Node 1 Environmental Control and Life Support (ECLS) System is comprised of five subsystems: Atmosphere Control and Storage (ACS), Atmosphere Revitalization (AR), Fire Detection and Suppression (FDS), Temperature and Humidity Control (THC), and Water Recovery and Management (WRM). This paper will provide a summary of the Node 1 ECLS THC subsystem design and a detailed discussion of the ISS ECLS Acceptance Testing methodology utilized for this subsystem.

Williams, David E.↗

Simulation and Optimization of Vacuum Swing Adsorption Units for Spacesuit Carbon Dioxide and Humidity Control

Controlling carbon dioxide (CO2) and humidity levels in a spacesuit is critical to ensuring both the safety and comfort of an astronaut during extra-vehicular activity (EVA). Traditionally, this has been accomplished utilizing either non-regenerative lithium hydroxide (LiOH) or regenerative but heavy metal oxide (MetOx) canisters which pose a significant weight burden. Although such technology enables air revitalization, the volume requirements to store the waste canisters as well as the mass to transport multiple units become prohibitive as mission durations increase. Consequently, motivation exists toward developing a fully regenerative technology for spacesuit environmental control. The application of solid amine materials with vacuum swing adsorption technology has shown the capacity to control CO2 while concomitantly managing humidity levels through a fully regenerative cycle eliminating constraints imposed with the traditional technologies. Prototype air revitalization units employing this technology have been fabricated in both a rectangular and cylindrical geometry. Experimental results for these test articles have been collected and are described herein. In order to accelerate the developmental efforts, an axially-dispersed plug flow model with an accompanying energy balance has been established and correlated with the experimental data. The experimental and simulation results display good agreement for a variety of flow rates (110-170 ALM), replicated metabolic challenges (100-590 Watts), and atmosphere pressures under consideration for the spacesuit (248 and 760 mm Hg). The testing and model results lend insight into the operational capabilities of these devices as well as the influence the geometry of the device has on performance. In addition, variable metabolic profiles were imposed on the test articles in order to assess the ability of the technology to transition to new metabolic conditions. The advent of the model provides the capacity to apply computer-aided engineering practices to support the ongoing efforts to optimize and mature this technology for future application to space exploration.

Swickrath, Michael J.↗

Measuring Humidity in Sealed Glass Encasements

A technique has been devised for measuring the relative humidity levels in the protective helium/water vapor atmosphere in which the Declaration of Independence, the United States Constitution, and the Bill of Rights are encased behind glass panels on display at the National Archives in Washington, DC. The technique is noninvasive: it does not involve penetrating the encasements (thereby risking contamination or damage to the priceless documents) to acquire samples of the atmosphere. The technique could also be applied to similar glass encasements used to protect and display important documents and other precious objects in museums. The basic principle of the technique is straightforward: An encasement is maintained at its normal display or operating temperature (e.g., room temperature) while a portion of its glass front panel is chilled (see Figure 1) until condensed water droplets become visible on the inside of the panel. The relative humidity of the enclosed atmosphere can then be determined as a known function of the dew point, the temperature below which the droplets condense. Notwithstanding the straightforwardness of the basic principle, careful attention to detail is necessary to enable accurate determination of the dew point. In the initial application, the affected portion of the glass panel was cooled by contact with an aluminum plate that was cooled by a thermoelectric module, the exhaust heat of which was dissipated by a heat sink cooled by a fan. A thermocouple was used to measure the interior temperature of the aluminum plate, and six other thermocouples were used to measure the temperatures at six locations on the cooled outer surface of the glass panel (see Figure 2). Thermal grease was applied to the aluminum plate and the thermocouples to ensure close thermal contact. Power was supplied to the thermoelectric module in small increments, based on previous laboratory tests. A small flashlight and a magnifying glass were used to look for water droplets condensing on the inner surface of the glass. The temperature readings of the thermocouples were taken during cool-down and upon observing condensation. In determining the dew point, it was necessary to make a correction for the differences between the temperatures measured on the chilled outer surface of the glass and the temperature of the inner surface, where the condensation took place. The correction was derived from a laboratory test on a measurement setup that was nearly identical, except that the dew location on the inner surface was also instrumented with a thermocouple. The test showed that the temperature at the dew location on the inner surface of the glass panel was 0.9 C above the temperature determined from the measurements on the chilled outer surface of the panel.

West, James W.↗

Single-Antenna Temperature- and Humidity-Sounding Microwave Receiver

For humidity and temperature sounding of Earth s atmosphere, a single-antenna/LNA (low-noise amplifier) is needed in place of two separate antennas for the two frequency bands. This results in significant mass and power savings for GeoSTAR that is comprised of hundreds of antennas per frequency channel. Furthermore, spatial anti-aliasing would reduce the number of horns. An anti-aliasing horn antenna will enable focusing the instrument field of view to the hurricane corridor by reducing spatial aliasing, and thus reduce the number of required horns by up to 50 percent. The single antenna/receiver assembly was designed and fabricated by a commercial vendor. The 118 183-GHz horn is based upon a profiled, smooth-wall design, and the OMT (orthomode transducer) on a quad-ridge design. At the input end, the OMT presents four ver y closely spaced ridges [0.0007 in. (18 m)]. The fabricated assembly contains a single horn antenna and low-noise broadband receiver front-end assembly for passive remote sensing of both temperature and humidity profiles in the Earth s atmosphere at 118 and 183 GHz. The wideband feed with dual polarization capability is the first broadband low noise MMIC receiver with the 118 to 183 GHz bandwidth. This technology will significantly reduce PATH/GeoSTAR mass and power while maintaining 90 percent of the measurement capabilities. This is required for a Mission-of-Opportunity on NOAA s GOES-R satellite now being developed, which in turn will make it possible to implement a Decadal-Survey mission for a fraction of the cost and much sooner than would otherwise be possible.

Hoppe, Daniel J.↗

Application of Artificial Neural Networks to the Development of Improved Multi-Sensor Retrievals of Near-Surface Air Temperature and Humidity Over Ocean

Improved estimates of near-surface air temperature and air humidity are critical to the development of more accurate turbulent surface heat fluxes over the ocean. Recent progress in retrieving these parameters has been made through the application of artificial neural networks (ANN) and the use of multi-sensor passive microwave observations. Details are provided on the development of an improved retrieval algorithm that applies the nonlinear statistical ANN methodology to a set of observations from the Advanced Microwave Scanning Radiometer (AMSR-E) and the Advanced Microwave Sounding Unit (AMSU-A) that are currently available from the NASA AQUA satellite platform. Statistical inversion techniques require an adequate training dataset to properly capture embedded physical relationships. The development of multiple training datasets containing only in-situ observations, only synthetic observations produced using the Community Radiative Transfer Model (CRTM), or a mixture of each is discussed. An intercomparison of results using each training dataset is provided to highlight the relative advantages and disadvantages of each methodology. Particular emphasis will be placed on the development of retrievals in cloudy versus clear-sky conditions. Near-surface air temperature and humidity retrievals using the multi-sensor ANN algorithms are compared to previous linear and non-linear retrieval schemes.

Roberts, J. Brent↗

Bias Correction for Assimilation of Retrieved AIRS Profiles of Temperature and Humidity

Atmospheric Infrared Sounder (AIRS) is a hyperspectral radiometer aboard NASA's Aqua satellite designed to measure atmospheric profiles of temperature and humidity. AIRS retrievals are assimilated into the Weather Research and Forecasting (WRF) model over the North Pacific for some cases involving "atmospheric rivers". These events bring a large flux of water vapor to the west coast of North America and often lead to extreme precipitation in the coastal mountain ranges. An advantage of assimilating retrievals rather than radiances is that information in partly cloudy fields of view can be used. Two different Level 2 AIRS retrieval products are compared: the Version 6 AIRS Science Team standard retrievals and a neural net retrieval from MIT. Before assimilation, a bias correction is applied to adjust each layer of retrieved temperature and humidity so the layer mean values agree with a short-term model climatology. WRF runs assimilating each of the products are compared against each other and against a control run with no assimilation. This paper will describe the bias correction technique and results from forecasts evaluated by validation against a Total Precipitable Water (TPW) product from CIRA and against Global Forecast System (GFS) analyses.

Blankenship, Clay↗

Bias Correction for Assimilation of Retrieved AIRS Profiles of Temperature and Humidity

The Atmospheric Infrared Sounder (AIRS) is a hyperspectral radiometer aboard NASA's Aqua satellite designed to measure atmospheric profiles of temperature and humidity. AIRS retrievals are assimilated into the Weather Research and Forecasting (WRF) model over the North Pacific for some cases involving "atmospheric rivers". These events bring a large flux of water vapor to the west coast of North America and often lead to extreme precipitation in the coastal mountain ranges. An advantage of assimilating retrievals rather than radiances is that information in partly cloudy fields of view can be used. Two different Level 2 AIRS retrieval products are compared: the Version 6 AIRS Science Team standard retrievals and a neural net retrieval from MIT. Before assimilation, a bias correction is applied to adjust each layer of retrieved temperature and humidity so the layer mean values agree with a short‐term model climatology. WRF runs assimilating each of the products are compared against each other and against a control run with no assimilation. Forecasts are against ERA reanalyses.

Blakenship, Clay↗

A Revised Calibration Function and Results for the Phoenix Mission TECP Relative Humidity Sensor

The original calibration function of the R(sub H) sensor on the Phoenix Thermal and Electrical Conductivity Sensor (TECP) has been revised in order to extend the range of the valid calibration, and to improve accuracy. The original function returned non-physical R(sub H) values at the lowest temperatures. To resolve this, and because the original calibration was performed against a pair of hygrometers that measured frost point (T(sub f)), the revised calibration equation is also cast in terms of frost point. Because of the complexity of maintaining very low temperatures and high R(sub H) in the laboratory, no calibration data exists at T is greater than 203K. However, sensor response during the mission was smooth and continuous down to 181 K. Therefore we have opted to include flight data in the calibration data set; selection was limited to data acquired during periods when the atmosphere is known to have been saturated. T(sub f) remained below 210 K throughout the mission(P is greater than 0.75 Pa). R(sub H), conversely, ranged from 1 to well under 0.01 diurnally, due to approximately 50 K temperature variations. To first order, both vapor pressure and its variance are greater during daylight hours. Variance in overnight humidity is almost entirely explained by temperature, while atmospheric turbulence contributes substantial variance to daytime humidity. Likewise, data gathered with the TECP aloft reflect higher H2O abundances than at the surface, as well as greater variance. There is evidence for saturation of the atmosphere overnight throughout much of the mission. In virtually every overnight observation, once the atmosphere cooled to T(sub f), water vapor begins to decrease, and tracks air temperature. There is no evidence for substantial decreases in water vapor prior to saturation, as expected for adsorptive exchange. Likewise, there is no evidence of local control of vapor by phases such as perchlorate hydrates hydrated minerals. The daytime average H2O pressure does not change substantially over the course of the mission, although the H2O column abundance varies by a factor of 2. Column abundances calculated from TECP data are lower than orbital measurements if one assumes that H2O is uniformly mixed through a single scale height. These results argue that the vertical distribution of H2O begins to change well in advance of surface concentrations as northern autumn approaches.

Phoenix Thermal and Electrical Conductivity Sensor↗

Development Requirements for the Exploration PLSS (xPLSS) Carbon Dioxide and Humidity Control Unit (CDHCU)

Functional Requirements for the Carbon Dioxide and Humidity Control Unit (CDHCU): The CDHCU is a component of the Exploration Portable Life Support System (xPLSS) to provide carbon dioxide (CO2) and humidity control within the spacesuit for a crewmember to perform extravehicular activities (EVA) in vacuum (micro-g), lunar, and Mars environments for up to 8 hours continuous, and during EVA preparation in airlocks or support vehicles for an additional 2 hours (TBR) continuous.

Chullen, Cinda↗

Physical Processes Controlling the Spatial Distributions of Relative Humidity in the Tropical Tropopause Layer over the Pacific

The spatial distribution of relative humidity with respect to ice (RHI) in the boreal wintertime tropical tropopause layer (TTL, is asymptotically Equal to 14-18 km) over the Pacific is examined with the measurements provided by the NASA Airborne Tropical TRopopause EXperiment. We also compare the measured RHI distributions with results from a transport and microphysical model driven by meteorological analysis fields. Notable features in the distribution of RHI versus temperature and longitude include (1) the common occurrence of RHI values near ice saturation over the western Pacific in the lower to middle TTL; (2) low RHI values in the lower TTL over the central and eastern Pacific; (3) common occurrence of RHI values following a constant mixing ratio in the middle to upper TTL (temperatures between 190 and 200 K); (4) RHI values typically near ice saturation in the coldest airmasses sampled; and (5) RHI values typically near 100% across the TTL temperature range in air parcels with ozone mixing ratios less than 50 ppbv. We suggest that the typically saturated air in the lower TTL over the western Pacific is likely driven by a combination of the frequent occurrence of deep convection and the predominance of rising motion in this region. The nearly constant water vapor mixing ratios in the middle to upper TTL likely result from the combination of slow ascent (resulting in long residence times) and wave-driven temperature variability. The numerical simulations generally reproduce the observed RHI distribution features, and sensitivity tests further emphasize the strong influence of convective input and vertical motions on TTL relative humidity.

Jensen, Eric J.↗

Influence of Cloud, Fog, and High Relative Humidity during Pollution Transport Events in South Korea: Aerosol Properties and PM2.5 Variability

This investigation examines aerosol dynamics during major fine mode aerosol transboundary pollution events in South Korea primarily during the KORUS-AQ campaign from May 1 – June 10, 2016, particularly when cloud fraction was high and/or fog was present to quantify the change in aerosol characteristics due to near-cloud or fog interaction. We analyze the new AERONET Version 3 data that have significant changes to cloud screening algorithms, allowing many more fine-mode observations in the near vicinity of clouds or fog. Case studies for detailed investigation include May 25–26, 2016 when cloud fraction was high over much of the peninsula, associated with a weak frontal passage and advection of pollution from China. These cloud-influenced Chinese transport dates also had the highest aerosol optical depth (AOD), surface PM2.5 concentrations and fine mode particle sizes of the entire campaign. Another likewise cloud/high relative humidity (RH) case is June 9 and 10, 2016 when fog was present over the Yellow Sea that appears to have affected aerosol properties well downwind over the Korean peninsula. In comparison we also investigated aerosol properties on air stagnation days with very low cloud cover and relatively low RH (May 17 & 18, 2016), when local Korean emissions dominated. Aerosol volume size distributions show marked differences between the transport days (with high RH and cloud influences) and the local pollution stagnation days, with total column-integrated particle fine mode volume being an order of magnitude greater on the pollution transport dates. The PM2.5 over central Seoul were significantly greater than for coastal sites on the transboundary transport days yet not on stagnation days, suggesting addi-tional particle formation from gaseous urban emissions in cloud/fog droplets and/or in the high RH humidified aerosol environment. Many days had KORUS-AQ research aircraft flights that provided observations of aerosol absorption, particle chemistry and vertical profiles of extinction. AERONET retrievals and aircraft in situ mea-surements both showed high single scattering albedo (weak absorption) on the cloudy or cloud influenced days, plus aircraft profile in situ measurements showed large AOD enhancements (versus dried aerosol) at ambient relative humidity (RH) on the pollution transport days, consistent with the significantly larger fine mode particle radii and weak absorption.

Aerosol↗

G-band FMCW Radar for Humidity Profiling Inside Boundary Layer Clouds

We are developing a G-band FMCW radar for remote sensing of vertical water vapor profiles and total column water vapor. The radar utilizes the frequency-dependent absorption near the 183 GHz water absorption line to obtain a differential signal from which we can derive range-resolved humidity measurements. This proof-of-concept instrument will eventually be tested from an airborne platform. In this report, we discuss recent measurements and a humidity profile retrieval algorithm based on an absorption line shape fitting model

Monje, Raquel↗

Variations in radiative heating of humid biomass burning aerosols in the southeast Atlantic from airborne observations and reanalysis

The atmosphere over the southeast Atlantic Ocean (SEA) experiences consistent springtime biomass burning (BB) smoke from widespread agricultural fires on the African continent. This smoke layer is initially lofted high in a continental mixed layer (~5-6km) and is then transported westward into the free troposphere where it overlies and ultimately mixes into a stratocumulus-topped oceanic boundary layer. Coincident with this smoke is an elevated humidity signal which is present from the time a given airmass is over the continental source region. ORACLES (ObseRvations of Aerosols above CLouds and their intEractionS) was a NASA Earth Venture Suborbital mission with the goal of measuring aerosol, cloud, and atmospheric properties over this region over three deployments in September 2016, August 2017, and October 2018. Measurements included in situ profile measurements of aerosol physical and optical properties, trace gas concentrations, and cloud properties, as well as column measurements of aerosol optical depth and trace gas concentrations from an airborne sun photometer. Here we present results from each of the ORACLES deployments over the southeast Atlantic Ocean. Despite the differing locations and season of each deployment, we show that there is good agreement between the airborne ORACLES dataset and large-scale reanalyses, specifically the ECMWF ERA5 reanalyses (and, to a degree, the CAMS product) as compared to other available products. This agreement allows us to examine multi-year seasonal patterns and trends beyond the three months with available aircraft data. In both the data and reanalysis, we find distinct variations between each deployment in terms of vertical smoke distribution and correlation to atmospheric specific humidity, due to changing conditions over the BB season. We trace the origin and the history of these smoky airmasses and finally, we briefly discuss the broader radiative and dynamical implications of these results for conditions of aerosols overlying stratocumulus clouds.

K. Pistone↗

Humidity Disrupts Structural and Chiroptical Properties of Chiral 2D Perovskites

Chiral two-dimensional (2D) hybrid organic–inorganic metal halide perovskite semiconductors have emerged as an exceptional material platform with many design opportunities for spintronic applications. However, a comprehensive understanding of changes to the crystal structure and chiroptical properties upon exposure to atmospheric humidity has not been established. We demonstrate phase degradation to the 1D (MBA)PbI 3 (MBA = methylbenzylammonium) and the hypothetical (MBA) 3 PbI 5 ·H 2 O hydrate phases, accompanied by a reduction and disappearance of the chiroptical response. Firstprinciple simulations show that water molecules preferentially locate at the interface between the organic cations and the inorganic framework, thereby disrupting the hydrogen bonding, impacting both the structural chirality and stability of the material. These findings provide critical insights into phase degradation mechanisms and their impact on chiroptical activity in chiral 2D perovskites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temperature, Humidity, and Time-Lapse Video Data from the East River Watershed, Water Years 2024 and 2025

This dataset contains time-lapse imagery and distributed measurements of air temperature, relative humidity, dew point, and soil temperature across the East River basin from 3 October 2023 to 8 August 2025. Instruments were deployed at 19 sites as part of the DOE Grant: Seasonal Cycles Unravel Mysteries of Missing Mountain Water organized by Jessica Lundquist (University of Washington), Rosemary Carroll (Desert Research Institute), and Ethan Gutmann (National Center for Atmospheric Research). The data are published to support studies of surface climate or hydrologic processes in complex terrain. Measurements were collected with low-cost data loggers installed 2 m high on evergreen trees or buried just below the soil surface. Time-lapse cameras were deployed at three sites. Imagery from sites AP BONUS and AP5 (Avery Picnic) provides insight into large-scale seasonal snow cover variability. Imagery from site EL2 (Emerald Lake) shows smaller-scale snow patterns across a nearby meadow. Dataset files are organized by site and variable (air measurements, ground measurements, or time-lapse video). Air and ground measurements are packaged in LoggerData.zip, and time-lapse imagery is compiled into short videos stored in TimelapseVideos.zip. File-level metadata contains details for each file included in the dataset. A data dictionary provides units and descriptions for column or row names in all files. The locations metadata file describes site characteristics, locations, and associated GPS methods.

54 ENVIRONMENTAL SCIENCES↗

Dielectric Engineering of ZnO@ZIF‐8 for High‐Performance Triboelectric Nanogenerators and Self‐Powered Humidity Sensors

Porous metal oxide–metal-organic framework (MO x @MOF) hybrids offer synergistic effects that enhance surface charge density, electronic structure, and textural properties, making them ideal for self-powered sensing applications. Here, uniform, and pinhole-free ternary porous ZnO–PTFE@ZIF-8 hybrid films are developed on room-temperature co-sputtered ZnO–polytetrafluoroethylene (PTFE) composite films, where ZnO serves as a self-sacrificial precursor to precisely regulate ZIF-8 (Zn-MeIm 2 ) growth through solvothermal methods. The resulting TENG achieves a high output power density of 0.67 mW cm −2 , attributed to the synergistic effects of fluorine-rich PTFE and methyl-functionalized ZIF-8, which enhance surface charge density and dielectric response. By tuning PTFE content in the ZnO–PTFE composite, the dielectric constant and triboelectric output is optimized. The ZP60@ZIF-8-based device also demonstrates excellent humidity sensing performance, with a wide detection range (20–99% RH) and ultrahigh sensitivity (R V % of 19 900%, R I % of 19 325% at 99% RH). These results position ZP@ZIF-8-based TENGs as promising platforms for next-generation self-powered sensors and smart wearable electronics.

42 ENGINEERING↗

Ni coarsening under humid atmosphere in the electrode of solid oxide cells: A combined study of density-functional theory and phase-field modeling

Ni coarsening in solid oxide cell (SOC) electrodes is known to be significantly faster under a humid atmosphere. The underlying mechanisms, though, have not been fully understood. In this work, we examine the surface diffusion of Ni(OH) x by a combination of density-functional theory and phase-field modeling. Here, density-functional theory is used to evaluate the adsorption and diffusion of the Ni(OH) x species on Ni (111) surface, and the results are used to obtain the effective surface diffusivity of Ni versus steam and hydrogen gas partial pressures. This diffusivity is used as an input for a phase-field model to investigate the Ni coarsening in SOC electrodes. It is found that Ni(OH) x formed through chemical reaction cannot accelerate coarsening unless an extremely high steam to hydrogen ratio is reached. However, if Ni(OH) x is formed through electrochemical reactions near triple phase boundaries (TPBs), surface diffusion of Ni(OH) x may cause faster Ni coarsening in fuel cell mode under a large overpotential. Specifically, surface diffusion of Ni(OH) may be comparable to or faster than that of Ni under an overpotential that is large but still possible under fuel cell operating conditions.

25 ENERGY STORAGE↗

Real-Time Ammonia and Humidity Monitoring with Ultra-Fast Conductometric Sensors Based on Porphyrin and Phthalocyanine Complexes

Organic semiconductors like porphyrins and phthalocyanines are attracting a wide range of researchers due to their versatile electrical properties and sensing performances in conductometric sensors. In this study, we investigate two types of π-extended porphyrins, which share the same macrocyclic structure but differ in their central metal. These porphyrins are employed as sublayers in bilayer heterojunction devices, with the lutetium bisphthalocyanine complex, LuPc 2 , serving as the common top layer. Remarkably, the central metal in the porphyrin macrocycle significantly influences the solubility of the materials and, consequently, the surface topography of the resulting bilayer heterojunction devices. This structural variation translates into distinct electrical and sensing performances. The device incorporating nickel as metal centre (AM2) demonstrates superior sensitivity towards NH3, with a relative response (RR) of ca. -7% at 90 ppm, an ultra-fast response time of about 9 s, and an impressive limit of detection (LOD) of 250 ppb, whereas, the device that has zinc as metal centre in sublayer (AM3) exhibits RR value of ca. -0.9% at 90 ppm with t 90 of ca. 120 s and LOD of 2 ppm. Both devices are evaluated under randomly varying NH 3 concentration and RH value. The results shows that the AM2-based sensor allows following NH 3 in real-time, while the AM3-based sensor delivers an average concentration over time. On the other hand, the AM2-based sensor exhibits slow kinetics under RH exposure, while the AM3-based sensor precisely mirrors the pattern of random RH changes generated by the software, demonstrating its exceptional responsiveness and accuracy in tracking humidity fluctuations. In conclusion, these findings underscore the critical role of the metal centre in tuning the electrical and sensing properties of the heterojunction devices.