Search NASA⌕ Search

SEARCH · Search NASA

Results for “ILC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The E166 experiment: Development of an Undulator-Based Polarized Positron Source for the International Linear Collider

A longitudinal polarized positron beam is foreseen for the international linear collider (ILC). A proof-of-principle experiment has been performed in the final focus test beam at SLAC to demonstrate the production of polarized positrons for implementation at the ILC. The E166 experiment uses a 1 m long helical undulator in a 46.6 GeV electron beam to produce a few MeV photons with a high degree of circular polarization. These photons are then converted in a thin target to generate longitudinally polarized e{sup +} and e{sup -}. The positron polarization is measured using a Compton transmission polarimeter. The data analysis has shown asymmetries in the expected vicinity of 3.4% and {approx}1% for photons and positrons respectively and the expected positron longitudinal polarization is covering a range from 50% to 90%. The full exploitation of the physics potential of an international linear collider (ILC) will require the development of polarized positron beams. Having both e{sup +} and e{sup -} beams polarized will provide new insight into structures of couplings and thus give access to physics beyond the standard model [1]. The concept for a polarized positron source is based on circularly polarized photon sources. These photons are then converted to longitudinally polarized e{sup +} and e{sup -} pairs. While in an experiment at KEK [1a], Compton backscattering is used [2], the E166 experiment uses a helical undulator to produce polarized photons. An undulator-based positron source for the ILC has been proposed in [3,4]. The proposed scheme for an ILC positron source is illustrated in figure 1. In this scheme, a 150 GeV electron beam passes through a 120 m long helical undulator to produce an intense photon beam with a high degree of circular polarization. These photons are converted in a thin target to e{sup +} e{sup -} pairs. The polarized positrons are then collected, pre-accelerated to the damping ring and injected to the main linac. The E166 experiment is dedicated to test this concept of a helical-undulator-based polarized positron source for the ILC. The experiment was carried out at SLAC where it benefitted from the high quality electron beam in the final focus test beam (FFTB).

43 PARTICLE ACCELERATORS↗

ATF2 Summary and Status

The Accelerator Test Facility (ATF) [1] at KEK was originally constructed as a Damping Ring (DR) demonstration facility for the next generation of electron linear colliders. It consists of a 1.3 GeV s-band linac and a 136m circumference damping ring which can routinely generate 1.6 nC electron bunches with very small vertical emittances (<10pm.rad). Completed in December of 2008, a new extraction line and final focus optics was built, this is referred to as ATF2 [2]. The location of ATF in-relation to the KEK site can be seen in Figure 1. ATF is a general-purpose facility for accelerator physics related R and D activities, with approximately 50% of the available beam time currently devoted to the ATF2 program. The ATF2 extraction line (EXT) and final focus system (FFS) extends about 90 meters from the DR extraction point, a sketch of this system can be seen in figure 2, along with the location of key instrumentation. The primary purpose of the ATF2 beam line is to demonstrate a new style of magnetic focusing optics intended for use at future linear colliders, such as ILC or CLIC based on a local chromaticity correction scheme. The primary goal of the collaboration is to demonstrate the ability of this optics to focus an electron beam of similar emittance to the ILC using a FFS of the same design chromaticity. A comparison of some of the ATF2 design parameters with those of the ILC and CLIC are shown in table 1. With the 1.3 GeV beam energy of ATF2, the target spot size to prove the operability of this optics for ILC is 37nm. This is referred to as 'Goal 1'. In addition, Goal 1 requires the demonstration of stable operations with such a beam size at the Interaction Point (IP). 'Goal 2' is to demonstrate nm-level stability with respect to the IP beam monitors, such as is required for stable beam collisions at ILC or CLIC. A further goal is to attempt to increase the chromaticity of the final focus optics, reducing the IP beta functions to a level where the system more closely resembles the CLIC FFS, and also for some of the newly proposed ILC parameters. It is anticipated that the difficulty of successfully tuning the FFS to deliver design IP beam spot sizes scales with the chromaticity of the system. The design of the achromatic focusing system involves fine cancelation of first, second and third order aberrations at the IP. One needs more accurate cancelation the tighter one attempts to focus the beam, also including more higher order terms. By gradually pushing the system to smaller IP beta functions and higher chromaticity we hope to learn what the limits of such a design are when applied practically. This will give confidence in the design philosophy behind future high-luminosity colliders and in the simulations used to predict their behaviour.

43 PARTICLE ACCELERATORS↗

Signal-preserving CMB component separation with machine learning

Analysis of microwave sky signals, such as the cosmic microwave background, often requires component separation using multifrequency methods, whereby different signals are isolated according to their different frequency behaviors. Many so-called blind methods, such as the internal linear combination (ILC), make minimal assumptions about the spatial distribution of the signal or contaminants, and only assume knowledge of the frequency dependence of the signal. The ILC produces a minimum-variance linear combination of the measured frequency maps. In the case of Gaussian, statistically isotropic fields, this is the optimal linear combination, as the variance is the only statistic of interest. However, in many cases the signal we wish to isolate, or the foregrounds we wish to remove, are non-Gaussian and/or statistically anisotropic (in particular for the case of Galactic foregrounds). In such cases, it is possible that machine learning (ML) techniques can be used to exploit the non-Gaussian features of the foregrounds and thereby improve component separation. However, many ML techniques require the use of complex, difficult-to-interpret operations on the data. We propose a hybrid method whereby we train an ML model using only combinations of the data that , and combine the resulting ML-predicted foreground estimate with the ILC solution to reduce the error from the ILC. We demonstrate our methods on simulations of extragalactic temperature and Galactic polarization foregrounds and show that our ML model can exploit non-Gaussian features, such as point sources and spatially varying spectral indices, to produce lower-variance maps than ILC—e.g., reducing the variance of the B-mode residual by factors of up to 5—while preserving the signal of interest in an unbiased manner. Moreover, we often find improved performance even when applying our ML technique to foreground models on which it was not trained. Published by the American Physical Society 2025

McCarthy, Fiona (ORCID:0000000253893565)↗

Neoadjuvant Endocrine Therapy Versus Neoadjuvant Chemotherapy in Node-Positive Invasive Lobular Carcinoma

Background: Neoadjuvant chemotherapy (NACT) is often recommended for patients with node-positive invasive lobular carcinoma (ILC) despite unclear benefit in this largely hormone receptor-positive (HR+) group. We sought to compare overall survival (OS) between patients with node-positive ILC who received neoadjuvant endocrine therapy (NET) and those who received NACT. Methods: Women with cT1–4c, cN1–3 HR+ ILC in the National Cancer Data Base (2004–2014) who underwent surgery following neoadjuvant therapy were identified. Kaplan–Meier curves and Cox proportional hazards modeling were used to estimate unadjusted and adjusted overall survival (OS), respectively. Results: Of the 5942 patients in the cohort, 855 received NET and 5087 received NACT. NET recipients were older (70 vs. 54 years) and had more comorbidities (Charlson–Deyo score ≥ 1: 21.1% vs. 11.5%), lower cT classification (cT3–4: 44.2% vs. 51.0%), lower rates of mastectomy (72.5% vs. 82.2%), lower rates of pathologic complete response (0% vs. 2.5%), and lower rates of postlumpectomy (73.2% vs. 91.0%) and postmastectomy (60.0% vs. 80.8%) radiation versus NACT recipients (all p < 0.001). NACT recipients had higher unadjusted 10-year OS versus NET recipients (57.9% vs. 36.0%), but after adjustment, there was no significant difference in OS between the two groups (p = 0.10). Conclusions: Patients with node-positive ILC who received NET presented with smaller tumors, older age, and greater burden of comorbidities versus NACT recipients but had similar adjusted OS. While there is evidence from clinical trials supporting efficacy of NET in HR+ breast cancer, our findings suggest the need for further, histology-specific investigation regarding the optimal inclusion and sequence of endocrine therapy and chemotherapy in ILC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Was Reexcision Less Frequent for Patients with Lobular Breast Cancer After Publication of the SSO-ASTRO Margin Guidelines?

Background: The Society of Surgical Oncology and American Society for Radiation Oncology consensus guidelines defined a negative margin for breast-conserving surgery (BCS) as no ink on tumor, and implementation has reduced rates of additional surgery for patients with invasive ductal cancer (IDC). The outcomes for invasive lobular cancer (ILC) patients are uncertain. Methods: This study identified patients who had stage 1 or 2 ILC treated with BCS from January 2010 to February 2018. The guidelines were adopted 1 January 2014. Clinicopathologic characteristics, margin status, and reexcisions were compared before and after adoption of the guidelines and with those of IDC patients treated from May 2013 to February 2015. Results: Among 745 early-stage ILC patients undergoing BCT, 312 (42%) were treated before the guidelines and 433 (58%) after the guidelines. Most clinicopathologic characteristics were similar between the two groups, with differences in lobular carcinoma in situ, lymphovascular invasion, and node-positivity rates. The overall rates of additional surgery declined significantly after the guidelines (31.4 to 23.1%; p = 0.01), but the difference did not reach significance for reexcisions (19.9 to 15.2%; p = 0.12) or conversions to mastectomy (11.5 to 7.9%; p = 0.099) individually. Between eras, no difference in incidence or number of tumor on ink or ≤ 2 mm margins was observed (all p = 0.2). Larger tumors, younger age, and pre-guideline era were independently associated with additional surgery. Only younger age was predictive of mastectomy. Among 431 pre-guideline and 601 post-guideline IDC patients, reexcisions declined from 21.3 to 14.8% (p = 0.008), and conversion to mastectomy was rare (0.6%). The magnitude of reduction in any additional surgery (interaction, p = 0.92) and reexcisions (interaction, p = 0.56) was similar between ILC and IDC. Conclusions: Despite differences in growth pattern and conspicuity, guideline adoption significantly reduced additional surgery among ILC patients, with a magnitude of benefit similar to that among IDC patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

International Linear Collider Physics and Detectors (2011 Status Report)

The studies of physics and detectors for the International Linear Collider are an important parallel element to the effort for the ILC Technical Design Report. The studies comprise the physics opportunities, detector requirements, and detector development to achieve the challenging high performance demanded by the physics, as well as integration of detectors into the accelerator. The current phase of this effort began with a call for Letters of Intent (LOIs) in 2007 and will lead to the submission of Detailed Baseline Design (DBD) report together with the ILC Technical Design Report at the end of 2012. Here we summarise the current status of this process, review what it has accomplished and identify the work that still needs to be completed. This report, titled International Linear Collider Physics and Detectors: 2011 Status Report, does just this. This report begins with a discussion of the outstanding issues in physics that motivate the construction of the ILC. It describes the organisation of the LOI process, the validation of the LOIs by the International Detector Advisory Group, and the results of R&D carried out to support the detector designs. The details of the concept detectors have already been published in the LOIs, which were completed in 2009. This report will, in a complementary way, describe the status of the detector R&D for each individual detector component and the status of the physics simulation infrastructure that has been built for the detector design process. Much of this work is carried out in cooperation between the two detector concept groups. This report describes the five common task groups and two working groups that have organised these cooperative activities. Many members of the detector concept groups and the common task groups have contributed to this report. Many more people have carried out the actual work that is reviewed. The complete list of members of each detector concept group can be found from the author lists of the published LOIs. The members of the ILC physics and detector organisation are listed at the end of this document. As we are now nearing the completion of the DBD phase, we are also entering a new stage of our preparation process. The experiments at the Large Hadron Collider at CERN, Switzerland, are accumulating data and are extending our knowledge of the physics of the teraelectronvolt energy scale. The LHC results may confirm the standard model of electroweak symmetry breaking or they may deliver something completely new. In either case, we believe, the ILC will be critical to resolve the questions that the LHC programme will bring forward. In any scenario, we will need very high-quality detectors and excellent technical and simulation capabilities. This report describes the status of our work in pursuit of that goal.

Brau, James E.↗

The International Linear Collider. A Global Project

A large, world-wide community of physicists is working to realise an exceptional physics program of energy-frontier, electron-positron collisions with the International Linear Collider (ILC). This program will begin with a central focus on high-precision and model-independent measurements of the Higgs boson couplings. This method of searching for new physics beyond the Standard Model is orthogonal to and complements the LHC physics program. The ILC at 250 GeV will also search for direct new physics in exotic Higgs decays and in pair-production of weakly interacting particles. Polarised electron and positron beams add unique opportunities to the physics reach. The ILC can be upgraded to higher energy, enabling precision studies of the top quark and measurement of the top Yukawa coupling and the Higgs self-coupling. The key accelerator technology, superconducting radio-frequency cavities, has matured. Optimised collider and detector designs, and associated physics analyses, were presented in the ILC Technical Design Report, signed by 2400 scientists. There is a strong interest in Japan to host this international effort. A detailed review of the many aspects of the project is nearing a conclusion in Japan. Now the Japanese government is preparing for a decision on the next phase of international negotiations, that could lead to a project start within a few years. The potential timeline of the ILC project includes an initial phase of about 4 years to obtain international agreements, complete engineering design and prepare construction, and form the requisite international collaboration, followed by a construction phase of 9 years.

43 PARTICLE ACCELERATORS↗

NGF induces adult stem Leydig cells to proliferate and differentiate during Leydig cell regeneration

Highlights: •Nerve growth factor has shown significant changes on mRNA levels during Adult Leydig cells regeneration. •We established the organ culture model of rat seminiferous tubules with ethane dimethyl sulphonate (EDS) treatment. •Nerve growth factor has shown proliferation and differentiation-promoting effects on Adult stem Leydig cells. •Nerve growth factor induces progenitor Leydig cells to proliferate and differentiate and immature Leydig cells to proliferate. -- Abstract: Nerve growth factor (NGF) has been reported to be involved in male reproductive physiology. However, few reports have described the activity of NGF during Leydig cell development. The objective of the present study was to examine the role of NGF during stem-Leydig-cell (SLC) regeneration. We investigated the effects of NGF on Leydig-cell (LC) regeneration by measuring mRNA levels in the adult rat testis after ethane dimethanesulfonate (EDS) treatment. Furthermore, we used the established organ culture model of rat seminiferous tubules to examine the regulation of NGF during SLC proliferation and differentiation using EdU staining, real-time PCR and western blotting. Progenitor Leydig cells (PLCs) and immature Leydig cells (ILCs) were also used to investigate the effects of NGF on LCs at different developmental stages. NGF mRNA levels changed significantly during Leydig-cell regeneration in vivo. In vitro, NGF significantly promoted the proliferation of stem Leydig cells and also induced steroidogenic enzyme gene expression and 3β-HSD protein expression. The data from PLCs and ILCs showed that NGF could increase Cyclin D1 and Hsd 17b3 mRNA levels in PLCs and Cyclin D1 mRNA levels in ILCs. These results indicate that NGF may play an important role during LC regeneration by regulating the proliferation and differentiation of LCs at different developmental stages, from SLCs to PLCs and from PLCs to ILCs. The discovery of this effect of NGF on Leydig cells will provide useful information for developing new potential therapies for PADAM (Partial Androgen Deficiency in the Aging Male)

60 APPLIED LIFE SCIENCES↗

Ingot Nb based SRF technology for the International Linear Collider

The International Linear Collider (ILC) is anticipated to be built as the next energy-frontier electron-positron colliding accelerator with a global effort in particle physics. Niobium based Superconducting Radio-Frequency (SRF) technology is required to provide beam-accelerating structure with elliptical cavity strings to linearly accelerate the electron and positron beams up to 250 GeV and to realize a center-of-mass energy of 500 GeV in collisions. The accelerator design and R&D efforts progressed, and the ILC Technical Design Report (ILC-TDR) was published in 2013. Niobium will take a critical role to generate electric field gradient with a frequency of 1.3 GHz, for accelerating the beam with the best efficiency, in energy balance, using RF superconductivity. This paper discusses a technical approach to provide Nb material (ingot) and thin disks for producing the elliptical cavity structure, with direct slicing from Nb ingot having sufficiently optimized purity and residual resistance ration (RRR) necessary for the ILC SRF cavities.

43 PARTICLE ACCELERATORS↗

INTERACTING GALACTIC NEUTRAL HYDROGEN FILAMENTS AND ASSOCIATED HIGH-FREQUENCY CONTINUUM EMISSION

Galactic H I emission profiles in an area where several large-scale filaments at velocities ranging from -46 km s{sup -1} to 0 km s{sup -1} overlap were decomposed into Gaussian components. Eighteen families of components defined by similarities of center velocity and line width were identified and related to small-scale structure in the high-frequency continuum emission observed by the Wilkinson Microwave Anisotropy Probe spacecraft, as evidenced in the Internal Linear Combination (ILC) map of Hinshaw et al. When the center velocities of the Gaussian families, which summarize the properties of all the H I along the lines of sight in a given area, are used to focus on H I channel maps the phenomenon of close associations between H I and ILC peaks reported in previous papers is dramatically highlighted. Of particular interest, each of two pairs of H I peaks straddles a continuum peak. The previously hypothesized model for producing the continuum radiation involving free-free emission from electrons is re-examined in light of the new data. By choosing reasonable values for the parameters required to evaluate the model, the distance for associated H I-ILC features is of order 30-100 pc. No associated H{alpha} radiation is expected because the electrons involved exist throughout the Milky Way. The mechanism for clumping and separation of neutrals and electrons needs to be explored. It is concluded that the small-scale ILC structure originates in the local interstellar medium and not at cosmological distances.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimal multifrequency weighting for CMB lensing

We report that extragalactic foregrounds in cosmic microwave background (CMB) temperature maps lead to significant biases in CMB lensing reconstruction if not properly accounted for. Combinations of multifrequency data have been used to minimize the overall map variance (internal linear combination, or ILC), or specifically null a given foreground, but these are not tailored to CMB lensing. In this paper, we derive an optimal multifrequency combination to jointly minimize CMB lensing noise and bias. We focus on the standard lensing quadratic estimator, as well as the "shear-only"and source-hardened estimators, whose responses to foregrounds differ. We show that an optimal multifrequency combination is a compromise between the ILC and joint deprojection, which nulls the thermal Sunyaev-Zel'dovich (tSZ) and cosmic infrared background (CIB) contributions. In particular, for a Simons Observatory-like experiment with ℓ max,T =3000, we find that profile hardening alone (with the standard ILC) reduces the bias to the lensing power amplitude by 40%, at a 20% cost in noise, while the bias to the cross-correlation with a LSST-like sample is reduced by nearly an order of magnitude at a 10% noise cost, relative to the standard quadratic estimator. With a small amount of joint deprojection the bias to the profile hardened estimator can be further reduced to less than half the statistical uncertainty on the respective amplitudes, at a 20% and 5% noise cost for the auto- and cross-correlation respectively, relative to the profile hardened estimator with the standard ILC weights. Finally, we explore possible improvements with more aggressive masking and varying ℓ max,T .

79 ASTRONOMY AND ASTROPHYSICS↗

First Beam and High-Gradient Cryomodule Commissioning Results of the Advanced Superconducting Test Accelerator at Fermilab

The advanced superconducting test accelerator at Fermilab has accelerated electrons to 20 MeV and, separately, the International Linear Collider (ILC) style 8-cavity cryomodule has achieved the ILC performance milestone of 31.5 MV/m per cavity. When fully completed, the accelerator will consist of a photoinjector, one ILC-type cryomodule, multiple accelerator R&D beamlines, and a downstream beamline to inject 300 MeV electrons into the Integrable Optics Test Accelerator (IOTA). We report on the results of first beam, the achievement of our cryomodule to ILC gradient specifications, and near-term future plans for the facility.

43 PARTICLE ACCELERATORS↗

Damping Ring R&D at CESR-TA

Accelerators that collide high energy beams of matter and anti-matter are essential tools for the investigation of the fundamental constituents of matter, and the search for new forms of matter and energy. A “Linear Collider” is a machine that would bring high energy and very compact bunches of electrons and positrons (anti-electrons) into head-on collision. Such a machine would produce (among many other things) the newly discovered Higgs particle, enabling a detailed study of its properties. Among the most critical and challenging components of a linear collider are the damping rings that produce the very compact and intense beams of electrons and positrons that are to be accelerated into collision. Hot dilute particle beams are injected into the damping rings, where they are compressed and cooled. The size of the positron beam must be reduced more than a thousand fold in the damping ring, and this compression must be accomplished in a fraction of a second. The cold compact beams are then extracted from the damping ring and accelerated into collision at high energy. The proposed International Linear Collider (ILC), would require damping rings that routinely produce such cold, compact and intense beams. The goal of the Cornell study was a credible design for the damping rings for the ILC. Among the technical challenges of the damping rings; the development of instrumentation that can measure the properties of the very small beams in a very narrow window of time, and mitigation of the forces that can destabilize the beams and prevent adequate cooling, or worse lead to beam loss. One of the most pernicious destabilizing forces is due to the formation of clouds of electrons in the beam pipe. The electron cloud effect is a phenomenon in particle accelerators in which a high density of low energy electrons, build up inside the vacuum chamber. At the outset of the study, it was anticipated that electron cloud effects would limit the intensity of the positron ring, and that an instability associated with residual gas in the beam pipe would limit the intensity of the electron ring. It was also not clear whether the required very small beam size could be achieved. The results of this study are important contributions to the design of both the electron and positron damping rings in which all of those challenges are addressed and overcome. Our findings are documented in the ILC Technical Design Report, a document that represents the work of an international collaboration of scientists. Our contributions include design of the beam magnetic optics for the 3 km circumference damping rings, the vacuum system and surface treatments for electron cloud mitigation, the design of the guide field magnets, design of the superconducting damping wigglers, and new detectors for precision measurement of beam properties. Our study informed the specification of the basic design parameters for the damping rings, including alignment tolerances, magnetic field errors, and instrumentation. We developed electron cloud modelling tools and simulations to aid in the interpretation of the measurements that we carried out in the Cornell Electron-positron Storage Ring (CESR). The simulations provide a means for systematic extrapolation of our measurements at CESR to the proposed ILC damping rings, and ultimately to specify how the beam pipes should be fabricated in order to minimize the effects of the electron cloud. With the conclusion of this study, the design of the essential components of the damping rings is complete, including the development and characterization (with computer simulations) of the beam optics, specification of techniques for minimizing beam size, design of damping ring instrumentation, R&D into electron cloud suppression methods, tests of long term durability of electron cloud coatings, and design of damping ring vacuum system components.

43 PARTICLE ACCELERATORS↗

The International Linear Collider Progress Report 2015

The ILC technical design is now being adapted to the preferred candidate site. Changes in layout are being managed by a rigorous change-control procedure. Series production of cavities for the European XFEL has shown that cavities can be mass-produced in industry with a performance well above XFEL requirements and close to that needed for the ILC. A number of technical developments are under way with a view to further reducing the ILC cost. This work must continue through the preparatory stage for ILC construction once resources become available. A summary of the design updates and of the further preparatory work needed is summarized in tabular form in the Appendix.

43 PARTICLE ACCELERATORS↗

Implications of the 750 GeV γγ Resonance as a Case Study for the International Linear Collider

If the γγ resonance at 750 GeV suggested by 2015 LHC data turns out to be a real effect, what are the implications for the physics case and upgrade path of the International Linear Collider? Whether or not the resonance is confirmed, this question provides an interesting case study testing the robustness of the ILC physics case. In this note, we address this question with two points: (1) Almost all models proposed for the new 750 GeV particle require additional new particles with electroweak couplings. The key elements of the 500 GeV ILC physics program - precision measurements of the Higgs boson, the top quark, and 4-fermion interactions - will powerfully discriminate among these models. This information will be important in conjunction with new LHC data, or alone, if the new particles accompanying the 750 GeV resonance are beyond the mass reach of the LHC. (2) Over a longer term, the energy upgrade of the ILC to 1 TeV already discussed in the ILC TDR will enable experiments in γγ and e + e - collisions to directly produce and study the 750 GeV particle from these unique initial states.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Final Report - Sensor Development for Future e + e - Colliders

This project advances electromagnetic calorimeter sensor development for future electron-positron colliders, particularly the International Linear Collider (ILC). The ILC, under consideration for construction in Japan, will collide electrons and positrons at a 500 GeV baseline center-of-mass collision energy. The multi-volume ILC Technical Design Report describes two detector concepts, SiD and ILD, based on their “Detailed Baseline Design” documents. SiD and ILD are continuing to develop their technologies in anticipation of a positive decision from Japan in 2018. The ILC and its detectors will make unprecedented precision measurements relating to the Higgs boson and the top quark, and search for new phenomena that could be missed at the LHC, such as electroweak particles expected in some beyond the standard models. The sensor development covered by this project primarily pertains to the electromagnetic calorimeters (EMCal). This work continues conceptual work towards realistic modules. It is important to emphasize that the HEP sensor development on this project will enable applications beyond HEP. It does not include detector engineering. This proposal is a collaboration among one National Laboratory and four universities from Japan and two National Laboratories and four universities from the U.S.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Project to Design and Build the Magnets for a New Test Beamline, the ATF2, at KEK

In order to achieve the high luminosity required at the proposed International Linear Collider (ILC), it is critical to focus the beams to nanometer size with the ILC Beam Delivery System, and to maintain the beams collisions with a nanometer-scale stability. To establish the technologies associated with this ultra-high precision beam handling, a special beamline has been designed and built as an extension of the existing extraction beamline of the Accelerator Test Facility at KEK, Japan. The ATF provides an adequate ultra-low emittance electron beam that is comparable to the ILC requirements; the ATF2 mimics the ILC final focus system to create a tightly focused, stable beam. There are 37 magnets in the ATF2, 29 quadrupoles, 5 sextupoles and 3 bends. These magnets had to be acquired in a short time and at minimum cost, which led to various acquisition strategies; but nevertheless they had to meet strict requirements on integrated strength, physical dimensions, compatibility with existing magnet movers and beam position monitors, mechanical stability and field stability and quality. This paper will describe how 2 styles of quadrupoles, 2 styles of sextupoles, one dipole style and their supports were designed, fabricated, refurbished or modified, measured and aligned by a small team of engineers from 3 continents.

43 PARTICLE ACCELERATORS↗

Recommendation for the Feasibility of more Compact LC Damping Rings

As part of the international Linear Collider (ILC) collaboration, we have compared the electron cloud (EC) effect for different Damping Ring (DR) designs respectively with 6.4 km and 3.2 km circumference and investigated the feasibility of the shorter damping ring with respect to the electron cloud build-up and related beam instabilities. The studies for a 3.2 km ring were carried out with beam parameters of the ILC Low Power option. A reduced damping ring circumference has been proposed for the new ILC baseline design SB2009 [1] and would allow considerable reduction of the number of components, wiggler magnets and costs. We discuss the impact of the proposed operation of the ILC at high repetition rate 10 Hz and address the necessary modifications for the DRs. We also briefly discuss the plans for future studies including the luminosity upgrade option with shorter bunch spacing, the evaluation of mitigation techniques and the integration of the CesrTA results into the Damping Ring design.

43 PARTICLE ACCELERATORS↗