Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE CONTRAST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Equation-of-state measured via x-ray phase contrast imaging for Epon 828/DEA epoxy

Epoxies are a broad class of polymer materials often used as adhesive, structural or binding materials. Epon 828 is an epoxy resin that can be polymerized with a variety of curing agents with the choice of curing agent potentially having an effect on the resulting epoxy polymer’s material properties. In this study, the dynamic behavior of Epon 828 epoxy resin cured with diethanolamine (DEA) is investigated through a series of tamped Richtmyer-Meshkov instability (RMI) experiments measured with x-ray phase-contrast imaging. The measured shock and particle velocities are combined with data in the literature to calibrate Mie-Grüneisen equations-of-state (EOS) for portions and combinations of the collective dataset. The calibrated Mie-Grüneisen EOS are validated against particle velocity profiles extracted from published literature using the Eulerian hydrocode CTH. Here, the Mie-Grüneisen EOS fit to only the tamped RMI experimental data presented here most closely follows the particle velocity profile in the published literature.

36 MATERIALS SCIENCE↗

Planar shock-induced bubble collapse and jetting in water captured via X-ray phase contrast imaging

Shock wave–bubble interactions in water manifest rich dynamics driven by a combination of strong pressure and density mismatches. They have a wide variety of applications, including the injection of pharmaceuticals, and through scaling, enable the exploration of various aspects of high-energy-density systems such as inertial confinement fusion. In this work, the interaction between a micrometric nitrogen bubble and a planar shock wave, characterized by a Mach number of M = 1.24 and a peak pressure of p max = 0.57 , is experimentally recorded using ultra-high-speed x-ray phase contrast imaging. Highly resolved radiographs provide access to all phase discontinuities along the beam path, offering quantities such as the time-varying bubble size, the speed of a jet produced during the bubble collapse, and the time evolution of the shock wave front, which are critical benchmark data for numerical scheme validation. This study addresses the lack of well-characterized, repeatable, and high spatiotemporal resolution experiments at negative Atwood numbers by providing shock–bubble visualization and corresponding numerical simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Robustness of phase retrieval methods in x-ray phase contrast imaging: A comparison

Purpose: The robustness of the phase retrieval methods is of critical importance for limiting and reducing radiation doses involved in x-ray phase contrast imaging. This work is to compare the robustness of two phase retrieval methods by analyzing the phase maps retrieved from the experimental images of a phantom. Methods: Two phase retrieval methods were compared. One method is based on the transport of intensity equation (TIE) for phase contrast projections, and the TIE-based method is the most commonly used method for phase retrieval in the literature. The other is the recently developed attenuation-partition based (AP-based) phase retrieval method. The authors applied these two methods to experimental projection images of an air-bubble wrap phantom for retrieving the phase map of the bubble wrap. The retrieved phase maps obtained by using the two methods are compared. Results: In the wrap's phase map retrieved by using the TIE-based method, no bubble is recognizable, hence, this method failed completely for phase retrieval from these bubble wrap images. Even with the help of the Tikhonov regularization, the bubbles are still hardly visible and buried in the cluttered background in the retrieved phase map. The retrieved phase values with this method are grossly erroneous. In contrast, in the wrap's phase map retrieved by using the AP-based method, the bubbles are clearly recovered. The retrieved phase values with the AP-based method are reasonably close to the estimate based on the thickness-based measurement. The authors traced these stark performance differences of the two methods to their different techniques employed to deal with the singularity problem involved in the phase retrievals. Conclusions: This comparison shows that the conventional TIE-based phase retrieval method, regardless if Tikhonov regularization is used or not, is unstable against the noise in the wrap's projection images, while the AP-based phase retrieval method is shown in these experiments to be superior to the TIE-based method for the robustness in performing the phase retrieval.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Viewing internal bubbling and microexplosions in combusting metal particles via x-ray phase contrast imaging

The combustion performance of metal particles for explosives, propellants, pyrotechnics, and bio-agent defeat can be optimized by controlling the chemistry, size, and coatings of the particles. Many pure and composite metal fuels used in these applications have been observed to microexplode during combustion. This causes particles to fragment, revealing fresh surfaces, which may enhance burn rates and efficiencies. Despite these potential benefits, few have attempted to control the bubbling and the microexplosion of metal powders as they combust in molten states. Here, we choose Al:Zr composite powders as a representative system to study bubbling and microexplosions and to identify active mechanisms. Using synchrotron x-rays and phase contrast imaging, we observe molten metal particles of various sizes as they burn in air at temperatures ranging from 2700 to 3500 K. We characterize bubble nucleation and growth in the interior of the particles during the combustion process, and we identify heterogeneous nucleation, slow growth and coalescence of bubbles, as well as rapid bubble growth leading to microexplosions. Bubble growth rates and Laplace pressures are calculated, and we find that during slow expansion growth rates are similar to classical predictions of bubble growth in superheated liquids. For rapid expansions we find that a critical growth rate of ~0.5m s –1 , independent of the initial particle size, is necessary to enable microexplosions. We calculate the rate of gas generation that is needed to enable this growth and we conclude that nitrogen is the gas most likely driving rapid bubble growth and fragmentation. Furthermore these results provide the first in situ observations of the mechanisms that control bubbling and microexplosions during the combustion of metal particles.

36 MATERIALS SCIENCE↗

THE TRENDS HIGH-CONTRAST IMAGING SURVEY. I. THREE BENCHMARK M DWARFS ORBITING SOLAR-TYPE STARS

We present initial results from a new high-contrast imaging program dedicated to stars that exhibit long-term Doppler radial velocity accelerations (or ''trends''). The goal of the TRENDS (TaRgetting bENchmark-objects with Doppler Spectroscopy) imaging survey is to directly detect and study the companions responsible for accelerating their host star. In this first paper of the series, we report the discovery of low-mass stellar companions orbiting HD 53665, HD 68017, and HD 71881 using NIRC2 adaptive optics (AO) observations at Keck. Follow-up imaging demonstrates association through common proper motion. These comoving companions have red colors with estimated spectral types of K7-M0, M5, and M3-M4, respectively. We determine a firm lower limit to their mass from Doppler and astrometric measurements. In the near future, it will be possible to construct three-dimensional orbits and calculate the dynamical mass of HD 68017 B and possibly HD 71881 B. We already detect astrometric orbital motion of HD 68017 B, which has a projected separation of 13.0 AU. Each companion is amenable to AO-assisted direct spectroscopy. Further, each companion orbits a solar-type star, making it possible to infer metallicity and age from the primary. Such benchmark objects are essential for testing theoretical models of cool dwarf atmospheres.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-D-207A-04: Use of Gradient Echo Plural Contrast Imaging (GEPCI) in MR-Guided Radiation Therapy: A Feasibility Study Targeting Brain Treatment

Purpose: To implement the Gradient Echo Plural Contrast Imaging(GEPCI) technique in MRI-simulation for radiation therapy and assess the feasibility of using GEPCI images with advanced inhomogeneity correction in MRI-guided radiotherapy for brain treatment. Methods: An optimized multigradient-echo GRE sequence (TR=50ms;TE1=4ms;delta-TE=4ms;flip angle=300,11 Echoes) was developed to generate both structural (T1w and T2*w) and functional MRIs (field and susceptibility maps) from a single acquisition. One healthy subject (Subject1) and one post-surgical brain cancer patient (Subject2) were scanned on a Philips Ingenia 1.5T MRI used for radiation therapy simulation. Another healthy subject (Subject3) was scanned on a 0.35T MRI-guided radiotherapy (MR-IGRT) system (ViewRay). A voxel spread function (VSF) was used to correct the B0 inhomogeneities caused by surgical cavities and edema for Subject2. GEPCI images and standard radiotherapy planning MRIs for this patient were compared focusing the delineation of radiotherapy target region. Results: GEPCI brain images were successfully derived from all three subjects with scan times of <7 minutes. The images derived for Subjects1&2 demonstrated that GEPCI can be applied and combined into radiotherapy MRI simulation. Despite low field, T1-weighted and R2* images were successfully reconstructed for Subject3 and were satisfactory for contour and target delineation. The R2* distribution of grey matter (center=12,FWHM=4.5) and white matter (center=14.6, FWHM=2) demonstrated the feasibility for tissue segmentation and quantification. The voxel spread function(VSF) corrected surgical site related inhomogeneities for Subject2. R2* and quantitative susceptibility map(QSM) images for Subject2 can be used to quantitatively assess the brain structure response to radiation over the treatment course. Conclusion: We implemented the GEPCI technique in MRI-simulation and in MR-IGRT system for radiation therapy. The images demonstrated that it is feasible to adopt this technique in radiotherapy for structural delineation. The preliminary data also enable the opportunity for quantitative assessment of radiation response of the target region and normal tissue.

60 APPLIED LIFE SCIENCES↗

High-speed x-ray phase contrast imaging and digital image correlation analysis of microscale shock response of an additively manufactured energetic material simulant

The performance of energetic materials subjected to dynamic loading significantly depends on their micro- and meso-scale structural morphology. The geometric versatility offered by additive manufacturing opens new pathways to tailor the performance of these materials. Additively manufactured energetic materials (AMEMs) have a wide range of structural characteristics with a hierarchy of length scales and process-inherent heterogeneities, which are hitherto difficult to precisely control. It is important to understand how these features affect AMEMs’ response under dynamic/shock loading. Therefore, temporally and spatially resolved measurements of both macroscopic behavior and micro- and meso-level processes influencing macroscopic behavior are required. In this paper, we analyze the shock compression response of an AMEM simulant loaded under several impact conditions and orientations. Furthermore, x-ray phase contrast imaging (PCI) is used to track features across the observed shock front and determine the linear shock velocity vs particle velocity equation of state, as well as to quantify the interior deformation fields via digital image correlation (DIC) analyses. Photon Doppler velocimetry is simultaneously used to measure the particle velocities of the specimens, which are consistent with those obtained from x-ray PCI. The DIC analyses provide an assessment of the average strain fields inside the material, showing that the average axial strain depends on the loading intensity and reaches as high as 0.23 for impact velocities up to 1.5 km/s. The overall results demonstrate the utility of x-ray PCI for probing “in-material” equation of state and interior strains associated with dynamic shock compression behavior of the AMEM simulant.

3D printing↗

Performance Sensitivity Studies on the PIAA Implementation of the High-Contrast Imaging Testbed

This slide presentation reviews the sensitivity studies on the Phase-Induced Amplitude Apodization (PIAA), or pupil mapping using the High-Contrast Imaging Testbed (HCIT). PIAA is a promising technique in high-dynamic range stellar coronagraph. This presentation reports on the investigation of the effects of the phase and rigid-body errors of various optics on the narrowband contrast performance of the PIAA/HCIT hybrid system. The results have shown that the 2-step wavefront control method utilizing 2-DMs is quite effective in compensating the effects of realistic phase and rigid-body errors of various optics

Phase-Induced Amplitude Apodization (PIAA)↗

SCExAO/CHARIS Near-IR High-Contrast Imaging and Integral Field Spectroscopy of the HIP 79977 Debris Disk

We present new, near-infrared (1.1–2.4 μm) high-contrast imaging of the bright debris disk surrounding HIP 79977 with the Subaru Coronagraphic Extreme Adaptive Optics system (SCExAO) coupled with the CHARIS integral field spectrograph. SCExAO/CHARIS resolves the disk down to smaller angular separations of (0".11; r ∼ 14 au) and at a higher significance than previously achieved at the same wavelengths. The disk exhibits a marginally significant east–west brightness asymmetry in H band that requires confirmation. Geometrical modeling suggests a nearly edge-on disk viewed at a position angle of ∼114°.6 east of north. The disk is best-fit by scattered-light models assuming strongly forward-scattering grains (g ∼ 0.5–0.65) confined to a torus with a peak density at r0 ∼ 53–75 au. We find that a shallow outer density power law of α(sub out) = −1 to −3 and flare index of β = 1 are preferred. Other disk parameters (e.g., inner density power law and vertical scale height) are more poorly constrained. The disk has a slightly blue intrinsic color and its profile is broadly consistent with predictions from birth ring models applied to other debris disks. While HIP 79977ʼs disk appears to be more strongly forward- scattering than most resolved disks surrounding 5–30 Myr old stars, this difference may be due to observational biases favoring forward-scattering models for inclined disks versus lower inclination, ostensibly neutral-scattering disks like HR 4796A’s. Deeper, higher signal-to-noise SCExAO/CHARIS data can better constrain the disk’s dust composition.

Goebel, Sean↗

Analyzer-based X-ray phase contrast imaging using the forward-diffracted o-beam in a few-millimetre-thick Bragg-case asymmetrically cut crystal

An analyzer-based X-ray phase contrast imaging experiment employing the forward-diffracted o-beam in a few-millimetre-thick Bragg-case asymmetrically cut analyzer crystal has been implemented and tested in a geometry similar to that used in conventional radiography. The high angular stability requirements were overcome using specially designed crystals and a closed-loop feedback intensity system, monitoring the intensity of the diffracted h-beam. Analyzer-based images (ABis) taken at different angular positions on the forward-diffracted o-beam rocking curve show different contrasts, as expected. However, the ABis did not show sharp borders. This was closely investigated by X-ray topography and Δ d / d mapping and was attributed to the stresses caused by the analyzer crystal's own weight in the bulk. Further investigation of the crystal design using finite element analysis coupled with dynamical theory of X-ray diffraction is envisaged.

Honnicke, Marcelo Goncalves (ORCID:000000033276432↗

Melting temperature of bismuth to 55 GPa using synchrotron X-ray phase contrast imaging

The melting temperature of elemental bismuth under high pressure has been measured to 55 GPa using synchrotron X-ray phase-contrast imaging in the laser-heated diamond anvil cell. Imaging of solid-liquid interface formation, combined with radiometric temperature and X-ray diffraction measurements, reveals a pronounced reduction in melting boundary slope in Bi-V with pressure. The unusually steep initial slope is attributed to low configurational entropy of melting, arising from structural ordering and coordination matching in the cool liquid, while slope reduction is driven by entropy increase correlated with significant liquid structure changes with rising pressure and temperature. Finally, the data rule out kinetic effects on melting in shock compression experiments and demonstrate the need for improved theoretical phase diagrams.

Materials science↗

Double sided grating fabrication for high energy X-ray phase contrast imaging

State of the art grating fabrication currently limits the maximum source energy that can be used in lab based x-ray phase contrast imaging (XPCI) systems. In order to move to higher source energies, and image high density materials or image through encapsulating barriers, new grating fabrication methods are needed. In this work we have analyzed a new modality for grating fabrication that involves precision alignment of etched gratings on both sides of a substrate, effectively doubling the thickness of the grating. Furthermore, we have achieved a front-to-backside feature alignment accuracy of 0.5 µm demonstrating a methodology that can be applied to any grating fabrication approach extending the attainable aspect ratios allowing higher energy lab based XPCI systems.

36 MATERIALS SCIENCE↗

Simultaneous 8.2 keV phase-contrast imaging and 24.6 keV X-ray diffraction from shock-compressed matter at the LCLS

In this paper, we demonstrate simultaneous phase-contrast imaging (PCI) and X-ray diffraction from shock compressed matter at the Matter in Extreme Conditions endstation, at the Linac Coherent Light Source (LCLS). We utilize the chromaticity from compound refractive X-ray lenses to focus the 24.6 keV 3rd order undulator harmonic of the LCLS to a spot size of 5 μm on target to perform X-ray diffraction. Simultaneous PCI from the 8.2 keV fundamental X-ray beam is used to visualize and measure the transient properties of the shock wave over a 500 μm field of view. Furthermore, we demonstrate the ability to extend the reciprocal space measurements by 5 Å –1 , relative to the fundamental X-ray energy, by utilizing X-ray diffraction from the 3rd harmonic of the LCLS.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Phase contrast imaging measurements of reversed shear Alfven eigenmodes during sawteeth in Alcator C-Mod

Reversed shear Alfven eigenmodes (RSAEs) have been observed with the phase contrast imaging diagnostic and Mirnov coils during the sawtooth cycle in Alcator C-mod [M. Greenwald et al., Nucl. Fusion 45, S109 (2005)] plasmas with minority ion-cyclotron resonance heating. Both down-chirping RSAEs and up-chirping RSAEs have been observed during the sawtooth cycle. Experimental measurements of the spatial structure of the RSAEs are compared to theoretical models based on the code NOVA[C. Z. Cheng and M. S. Chance, J. Comput. Phys. 71, 124 (1987)] and used to derive constraints on the q profile. It is shown that the observed RSAEs can be understood by assuming a reversed shear q profile (up chirping) or a q profile with a local maximum (down chirping) with q{approx_equal}1.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurements of Mode Converted Ion Cyclotron Wave with Phase Contrast Imaging in Alcator C-Mod and Comparisons with Synthetic PCI Simulations in TORIC

Mode converted ion cyclotron wave (ICW) has been observed with phase contrast imaging (PCI) in D-{sup 3}He plasmas in Alcator C-Mod. The measurements were carried out with the optical heterodyne technique using acousto-optic modulators which modulate the CO2 laser beam intensity near the ion cyclotron frequency. With recently improved calibration of the PCI system using a calibrated sound wave source, the measurements have been compared with the full-wave code TORIC, as interpreted by a synthetic diagnostic. Because of the line-integrated nature of the PCI signal, the predictions are sensitive to the exact wave field pattern. The simulations are found to be in qualitative agreement with the measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-Ray Phase Contrast Imaging (XPCI) System

Sandia National Laboratories (Sandia) and Carestream Health, Inc. (CHI) collaborated on the development of a grating-based X-ray Phase Contrast Imaging (XPCI) system at Sandia. The purpose of the agreement was to share research and development knowledge, resources, and capabilities in the advancement of XPCI that would be mutually beneficial to CHI and Sandia. In the course of this agreement Sandia designed and built an XPCI apparatus including opto-mechanical design, source and x-ray detector selection, software interface, hardware assembly, and system alignment. Data acquisition and image reconstruction were demonstrated at both CHI and Sandia. XPCI is a new imaging modality that enables non-destructive inspection of low density materials not previously possible with conventional x-ray. The technique fills a capability gap valuable to both the industry partner in their technical portfolio and in national security applications important to Sandia and the DOE mission space.

47 OTHER INSTRUMENTATION↗

A Pockels cell enabled heterodyne phase contrast imaging diagnostic for detection of ion cyclotron emission

This work describes a novel optical heterodyne detection scheme that significantly extends the frequency response of the phase contrast imaging method to detect electron density fluctuations in tens of megahertz frequency range. The system employs a variable frequency electro-optic modulator to allow operation at any frequency in the range 10–40 MHz without the need to realign the system. The frequency coverage of the system makes it suitable to measure the radial structure of the electron density component of ion cyclotron emission on devices having confining magnetic field of a few tesla, thus extending the purely temporal measurements provided so far by magnetic probes.

47 OTHER INSTRUMENTATION↗

High-contrast imaging of intermediate-mass giants with long-term radial velocity trends

A radial velocity (RV) survey for intermediate-mass giants has been in operation for over a decade at Okayama Astrophysical Observatory (OAO). The OAO survey has revealed that some giants show long-term linear RV accelerations (RV trends), indicating the presence of outer companions. Direct-imaging observations can help clarify what objects generate these RV trends. We present the results of high-contrast imaging observations of six intermediate-mass giants with long-term RV trends using the Subaru Telescope and HiCIAO camera. We detected co-moving companions to γ Hya B (0.61{sub −0.14}{sup +0.12}M{sub ⊙}), HD 5608 B (0.10±0.01M{sub ⊙}), and HD 109272 B (0.28±0.06M{sub ⊙}). For the remaining targets (ι Dra, 18 Del, and HD 14067), we exclude companions more massive than 30–60 M {sub Jup} at projected separations of 1″–7″. We examine whether these directly imaged companions or unidentified long-period companions can account for the RV trends observed around the six giants. We find that the Kozai mechanism can explain the high eccentricity of the inner planets ι Dra b, HD 5608 b, and HD 14067 b.

79 ASTRONOMY AND ASTROPHYSICS↗