Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE CONTRAST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Fourier-based three-dimensional multistage transformer for aberration correction in multicellular specimens

High-resolution tissue imaging is often compromised by sample-induced optical aberrations that degrade resolution and contrast. Although wavefront sensor-based adaptive optics (AO) can measure these aberrations, such hardware solutions are typically complex, expensive to implement and slow when serially mapping spatially varying aberrations across large fields of view. Here we introduce AOViFT (adaptive optical vision Fourier transformer)—a machine learning-based aberration sensing framework built around a three-dimensional multistage vision transformer that operates on Fourier domain embeddings. AOViFT infers aberrations and restores diffraction-limited performance in puncta-labeled specimens with substantially reduced computational cost, training time and memory footprint compared to conventional architectures or real-space networks. We validated AOViFT on live gene-edited zebrafish embryos, demonstrating its ability to correct spatially varying aberrations using either a deformable mirror or postacquisition deconvolution. By eliminating the need for the guide star and wavefront sensing hardware and simplifying the experimental workflow, AOViFT lowers technical barriers for high-resolution volumetric microscopy across diverse biological samples.

Alshaabi, Thayer [Howard Hughes Medical Institute,↗

Accelerated Over-The-Air Neural Receiver Training Using Self-Contrastive Learning

Self-contrastive learning (SCL), a self-supervised learning method, has been shown to improve image and signal classifier accuracies and reduce the training time for neural communications receivers. In particular, prior work has shown that SCL applied as a pre-training step can improve simulated performance of OFDM in 3GPP TDL channel models by reducing the training time of the downstream classification task (demodulation and demapping). In this work a practical implementation demonstrating SCL pre-training using software defined radios (SDRs) is proposed.

Cooke, Corey [ORNL] (ORCID:0000000234263672)↗

Voltage-induced magnetic domain evolution in a phase-change material

Applying voltage to metal–insulator transition (MIT) materials allows electrical actuation of the local electronic phase state. In MIT systems that have the electronic order coupled with the magnetic order, voltage switching of the electronic phase state can also enable the electrical manipulation of magnetic properties. In this work, we utilized x-ray magnetic circular dichroism photoemission electron microscopy (XMCD-PEEM) to investigate the control of magnetic domain configurations in ferromagnetic MIT electrical switches. For applied voltages above a threshold value, the XMCD-PEEM images show that the magnetic domains separate into two distinct regions: one with a high contrast (white/black), indicating well-defined micrometer-scale magnetic domains with a component of their magnetization aligned parallel/antiparallel to the x-ray helicity, and the other with different shades of intermediate contrast (gray). Significant changes in magnetic domain configurations upon voltage biasing were only observed in these gray regions. Furthermore, the voltage-induced magnetic domain separation was found to be bias polarity-dependent, with the gray regions expanding from the opposite sample edge when the applied voltage polarity was reversed. This polarity-dependent electrical control of magnetic domain configurations during the MIT switching opens alternative opportunities in memory applications for magnetic MIT switching materials.

42 ENGINEERING↗

Bragg Coherent Imaging of Fluctuating Domains

This review presents two examples of domain dynamics in crystalline solid state samples which were imaged recently with synchrotron X-rays by Bragg Coherent Diffraction methods. Domains are associated with sub-atomic phase shifts in the structure which are revealed by the strong phase contrast associated with Bragg diffraction. At low temperatures, La2-xSrxNiO4 has an antiferromagnetic spin-ordered phase with correlation lengths of 200 nm; its domains are imaged with magnetic Bragg Ptychography to visualize their slow fluctuations. Hydrothermally synthesized nanocrystalline BaTiO3 is found to be made up of ~50 nm domains using Bragg Coherent Diffraction Imaging; electric field induced movement of its internal domain walls is a likely explanation of the nano-material's anomalously large dielectric constant, which is used in the manufacture of multilayer ceramic capacitors

77 NANOSCIENCE AND NANOTECHNOLOGY↗

AI-enabled Lorentz microscopy for quantitative imaging of nanoscale magnetic spin textures

The manipulation and control of nanoscale magnetic spin textures are of rising interest as they are potential foundational units in next-generation computing paradigms. Achieving this requires a quantitative understanding of the spin texture behavior under external stimuli using in situ experiments. Lorentz transmission electron microscopy (LTEM) enables real-space imaging of spin textures at the nanoscale, but quantitative characterization of in situ data is extremely challenging. Here, we present an AI-enabled phase-retrieval method based on integrating a generative deep image prior with an image formation forward model for LTEM. Our approach uses a single out-of-focus image for phase retrieval and achieves significantly higher accuracy and robustness to noise compared to existing methods. Furthermore, our method is capable of isolating sample heterogeneities from magnetic contrast, as shown by application to simulated and experimental data. This approach allows quantitative phase reconstruction of in situ data and can also enable near real-time quantitative magnetic imaging.

36 MATERIALS SCIENCE↗

Selective Amnesia using Contrastive Subnet Erasure for Class Level Unlearning in Vision Models

We study concept-level forgetting in pretrained vision models: removing an entire semantic category so the system no longer recognizes that object in unseen images and contexts, rather than merely forgetting specific training examples. Prior work either applies blunt global projections or fine-tunes parameters, which can introduce collateral damage to unrelated features, add compute, and become unstable as forgetting strength increases. We introduce Contrastive Subnet Erasure (CSE), a training-free, encoder-centric edit that targets a compact set of channels most responsible for the class and attenuates them in a calibrated manner. The modification is algebraically folded into the subsequent layer, yielding no inference-time overhead and leaving task heads unchanged. To evaluate whether forgetting generalizes beyond the data used to specify the class, we introduce a cross dataset protocol in which the class is defined on a source dataset and performance is measured on a disjoint target dataset drawn from a different distribution with no shared images. This setup tests whether the model still fails to recognize the object when it looks different or appears in new scenes, and it helps avoid overfitting to patterns in the source dataset. Across CIFAR 10, CIFAR 100, and ImageNet under this protocol, CSE achieves stronger forgetting of the target class while better preserving non target utility than existing baselines in both single class and multi class settings. Overall, CSE provides a simple, stable, and deployment-ready mechanism for class-level unlearning in vision.

Kotevska, Olivera [ORNL] (ORCID:0000000316772243)↗

Cone beam neutron interferometry: From modeling to applications

Phase-grating moiré interferometers (PGMIs) have emerged as promising candidates for the next generation of neutron interferometry, enabling the use of a polychromatic beam and manifesting interference patterns that can be directly imaged by existing neutron cameras. However, the modeling of the various PGMI configurations is limited to cumbersome numerical calculations and backward propagation models which often do not enable one to explore the setup parameters. Here we generalize the Fresnel scaling theorem to introduce a k -space model for PGMI setups illuminated by a cone beam, thus enabling an intuitive forward propagation model for a wide range of parameters and experimental setups. The interference manifested by a PGMI is shown to be a special case of the Talbot effect, and the optimal fringe visibility is shown to occur at the moiré location of the Talbot distances. We derive analytical expressions for the contrast and the propagating intensity profiles in various conditions and provide the first analysis of the PGMI dark-field imaging signal when considering sample characterization. The model's predictions are compared to experimental measurements and good agreement is found between them. Last, we propose and experimentally verify a method to recover contrast at typically inaccessible PGMI autocorrelation lengths. The presented work provides a toolbox for analyzing and understanding existing PGMI setups and their future applications, for example extensions to two-dimensional PGMIs and characterization of samples with nontrivial structures. Published by the American Physical Society 2024

Sarenac, D. (ORCID:0000000185753367)↗

X-ray and Neutron Radiography for Quantitative Material Reconstructions

Radiography is a powerful tool to determine the interior structure of objects. X-ray radiography is widely used and provides high-resolution images, though X-rays have limited transmission through materials of high atomic number (Z) and density. In contrast, neutrons can penetrate many materials that are heavily attenuating to X-rays, such as metals, providing contrast in the inner layers of highly attenuating items. Past work has shown the value in using both X-ray and neutron radiography for estimating material thicknesses, though that work was limited to simulated data. Here, we demonstrate quantitative material reconstructions using experimental X-ray and neutron radiography data from lab-based systems, accurately modeling radiography system responses to within a few percent to enable quantitative measures of material thickness. We demonstrate the utility of neutron radiography and X-ray radiography for these quantitative reconstructions and introduce methods for using their complementarity to improve image quality and optimize experimental design.

Gilbert, Andrew J.↗

High-resolution in-situ characterization of laser powder bed fusion via transmission X-ray microscopy at X-ray free electron lasers

In this work, we describe the instrumentation used to perform the first operando transmission X-ray microscopy (TXM) and simultaneous X-ray diffraction of laser melting simulating laser powder bed fusion on the XCS instrument at the Linac Coherent Light Source (LCLS) X-ray free-electron laser (XFEL). Our TXM with 40× magnification in the X-ray regime at 11 keV gave spatial resolutions down to 940 nm per line pair, with effective pixel sizes down to 206 nm, image integration times of <100 fs, and frame rates tunable between 2.1 and 119 ns for two probe frames (0.48 GHz to 8.4 MHz). Images were recorded on Zyla and Icarus (UXI) detectors to trade off between spatial resolution and time dynamics. A 1 kW CW IR laser was coupled into the interaction point to conduct pump–probe studies of laser melting and solidification dynamics. Our temporal and spatial resolution with attenuation-based contrast exceeds that currently possible with synchrotron-based high-speed radiography. This system was sensitive to feature velocities of 10–12000 m s −1 but we did not observe any motion in this range in the laser melting of Al6061 alloy. Shockwaves were not observed and hot cracking proceeded at velocities below the detection limits. Pore accumulation was observed between successive shots, indicating that bubble escape mechanisms were not active. With proper experimental design, the spatial resolution, contrast and field of view could be further improved or modified. The increased brightness and narrower bandwidth of the XFEL allowed for this imaging technique and it lays the groundwork for a wide range of operando techniques to study additive manufacturing.

47 OTHER INSTRUMENTATION↗

In Situ Tracking of Nonthermal Plasma Etching of ZIF-8 Films

Surface characterization is critical for understanding the processes used for preparing catalysts, sorbents, and membranes. Nonthermal plasma (NTP) is a process that achieves high reactivity at low temperatures and is used to tailor the surface properties of materials. In this work, we combine the capabilities of infrared reflection absorption spectroscopy (IRRAS) with NTP for the in situ interrogation of zeolitic imidazolate framework-8 (ZIF-8) thin films to probe modifications in the material induced by oxygen and nitrogen plasmas. The IRRAS measurements in oxygen plasma reveal etching of organic ligands with sequential removal of the methyl group and imidazole ring and with the formation of carbonyl moieties (C═O). In contrast, nitrogen plasma induces mild etching and grafting of nitrile groups (−C≡N). Scanning electron microscopy imaging shows that oxygen plasma, at prolonged times, significantly degrades the ZIF-8 film at the grain boundaries. Treatment of ZIF-8 membranes using mild plasma conditions yields a fivefold enhancement for H 2 /N 2 and CO 2 /CH 4 ideal selectivities and an eightfold enhancement for CO 2 /N 2 ideal selectivity. Additionally, the new tools described here can be used for spectroscopic in situ tracking of plasma-induced chemistry on thin films in general.

IRRAS↗

Characterization of Incremental Markings in the Sagittal Otolith of the Pacific Sardine ( Sardinops sagax ) Using Different Imaging Modalities

Teleost fish possess calcium carbonate otoliths located in separate chambers (utriculus, sacculus, and lagena) of their membranous labyrinth. This study analyzed the surface topography of the sagittal otolith of the Pacific sardine (Sardinops sagax) and the daily and annual increments in these otoliths. The otolith surface, characterized by laser scanning confocal microscopy for the first time, consisted of a system of prominent ridges and valleys (grooves), but it is unclear whether these structures are functional or represent time-resolving markings reflecting growth periodicity. Within the first-year volume, daily increments, each consisting of an incremental (more mineralized) and a discontinuous (less mineralized) zone, were resolved by optical microscopy and backscattered electron (BSE) imaging in the scanning electron microscope (SEM). Daily growth increments could, however, not be resolved in volumes formed after the first year, presumably because otolith growth markedly slows down and spacing of incremental markings narrows in older fish. Throughout otolith growth, the crystalline network continues across the discontinuous zones. Fluorochrome labeling provides additional information on growth after the first year. Compared with optical and BSE imaging, synchrotron microComputed Tomography of intact otoliths (with 0.69 µm volume elements) was less able to resolve daily increments; X-ray phase contrast reconstructions provided more detail than reconstructions with absorption contrast. Future research directions are proposed.

59 BASIC BIOLOGICAL SCIENCES↗

The Amazon River‐Breeze Circulation Limits Detection of Aerosol‐Cloud Interactions in Warm Clouds

Increased aerosol concentrations can brighten low-level clouds and extend their lifetimes, but aerosol–cloud interactions (ACI) remain highly uncertain and difficult to quantify. We show that part of this uncertainty is caused by topographical influences on clouds, that is, those arising from land–water contrasts. This is demonstrated using satellite retrievals in regions with extensive river networks, such as the Amazon Basin. 15 years of MODerate resolution Imaging Spectroradiometer (MODIS) satellite data show cloud formation over the Amazon River basin is suppressed by 26% with warm low clouds above the river exhibiting a 22% smaller droplet effective radius and 18% higher droplet concentration ($N_d$) compared to adjacent land clouds. Thus, clouds above the river may appear polluted but are actually influenced by river-breeze circulations driven by the thermal contrast between the river and the surrounding land. These responses are robust in both wet and dry seasons, and tests using an improved MODIS retrieval product show cloud differences are unlikely due to retrieval artifacts. In situ measurements from the Green Ocean Amazon Experiment (GoAmazon) confirm that $N_d$ is elevated above rivers and are also higher when carbon monoxide concentrations are elevated near the large city of Manaus. Lagrangian airmass tracking over Manaus shows that regional-scale river-breeze circulations impact $N_d$ as much as the urban aerosol plume, complicating ACI attribution and highlighting the need to isolate land-surface effects to assess ACI in continental regions.

Aerosol-Cloud Interactions↗

Phase-resolving spin-wave microscopy using infrared strobe light

The need for sensitively and reliably probing magnetization dynamics has been increasing in various contexts such as studying novel hybrid magnonic systems, in which the spin dynamics strongly and coherently couple to other excitations, including microwave photons, light photons, or phonons. Recent advances in quantum magnonics also highlight the need for employing the magnon phase as quantum state variable, which is to be detected and mapped out with high precision in on-chip micro- and nanoscale magnonic devices. Here, in this study, we demonstrate a facile optical technique that can directly perform concurrent spectroscopic and imaging functionalities with spatial and phase resolutions, using infrared strobe light operating at 1550-nm wavelength. To showcase the methodology, we spectroscopically studied the phaseresolved spin dynamics in a bilayer of Permalloy and yttrium iron garnet Y 3 Fe 5 O 12 (YIG), and spatially imaged the backward-volume spin-wave modes of YIG in the dipolar spin-wave regime. Using the strobe light probe, the detected precessional phase contrast can be directly used to construct the map of the spin wave's wave front, in the continuous-wave regime of spin-wave propagation and in the stationary state, without needing any optical reference path. By selecting the applied field, frequency, and detection phase, the spin-wave images can be made sensitive to the precession amplitude and phase. Our results demonstrate that infrared optical strobe light can serve as a versatile platform for magneto-optical probing of magnetization dynamics, with potential implications in investigating hybrid magnonic systems.

Xiong, Yuzan [University of North Carolina, Chapel↗

Operando Neutron Imaging of Reaction Extent and Particle Swelling Informs Limiting Factors for Salt Hydrate Thermochemical Energy Storage

Salt hydrates are a promising thermochemical energy storage medium that stores heat through the reversible uptake (hydration) and release (dehydration) of water vapor. Our study deploys operando neutron imaging to investigate salt hydrate performance with high spatial resolution (42 μm pixels). For flow over a packed bed with diffusion-driven transport, measurements reveal the formation of a solid diffusion layer due to particle swelling for the pure SrBr2 salt. In contrast, the SrBr2–vermiculite composite exhibits significantly less swelling and more than a 2-fold increase in the apparent water vapor diffusivity. For axial flow through a packed bed, neutron imaging confirms theoretically predicted transitions from a moving reaction front to a homogeneous profile with an increase in humid air flow rate. Our study establishes neutron imaging as a powerful technique to advance fundamental understanding of thermochemical systems and help guide composite material design.

Kinzer, Bryan [ORNL] (ORCID:0000000337804910)↗

Solution-Processed Temperature-Adaptive Radiative Paint as a Thermal Imaging Sensitizer

Thermography detects mid-infrared radiation from surfaces based on the Stefan-Boltzmann law, mapping surface temperatures and potentially revealing subsurface thermal activity. Recent developments offer an alternative strategy to traditional camera-based improvements: a thermal imaging sensitizer (TIS) coating whose emissivity increases sharply with local temperature, amplifying small thermal variations into high-contrast signals. Existing TIS structures are nanofabricated solid membranes and face significant challenges in fabrication complexity. Here, in this study, we present a solution-processed, liquid form of TIS, termed temperature-adaptive radiative paint (TARP), to address these limitations. TARP offers drastically reduced fabrication costs, scalability to large areas, applicability to curved surfaces, and an extended operating temperature range, while maintaining the function of temperature amplification. Application of TARP enhances small temperature contrast by more than 3 times, substantially improving ambient thermography and enabling broader applications such as detection of structural defects and hot spots in electronic components.

paint↗

Deep learning of structural morphology imaged by scanning X-ray diffraction microscopy

Scanning X-ray nanodiffraction microscopy is a powerful technique for spatially resolving nanoscale structural morphologies by diffraction contrast. One of the critical challenges in experimental nanodiffraction data analysis is posed by the convergence angle of nanoscale focusing optics which creates simultaneous dependency of the far-field scattering data on three independent components of the local strain tensor-corresponding to dilation and two potential rigid body rotations of the unit cell. All three components are in principle resolvable through a spatially mapped sample tilt series; however, traditional data analysis is computationally expensive and prone to artifacts. In this study, we implement NanobeamNN, a convolutional neural network specifically tailored to the analysis of scanning probe X-ray microscopy data. NanobeamNN learns lattice strain and rotation angles from simulated diffraction of a focused X-ray nanobeam by an epitaxial thin film and can directly make reasonable predictions on experimental data without the need for additional fine-tuning. We demonstrate that this approach represents a significant advancement in computational speed over conventional methods, as well as a potential improvement in accuracy over the current standard.

Luo, Aileen [Cornell Univ., Ithaca, NY (United Sta↗

Beyond Contrast Transfer: Spectral SNR as a Finite-Dose Metric for STEM Phase Retrieval

The contrast transfer function (CTF) is widely used to evaluate phase retrieval methods in scanning transmission electron microscopy (STEM), including center-of-mass imaging, parallax imaging, direct ptychography, and iterative ptychography. However, the CTF reflects only the maximum usable signal, neglecting the effects of finite electron fluence and the Poisson-limited nature of detection. As a result, it can significantly overestimate practical performance, especially in low-dose regimes. Here, we employ the spectral signal-to-noise ratio (SSNR), as a finite-dose statistical framework to evaluate the recoverable signal as a function of spatial frequency. Using numerical reconstructions of white-noise objects, we show that center-of-mass, parallax, and direct ptychography exhibit dose-independent SSNRs, with close-form analytic expressions. In contrast, iterative ptychography exhibits a surprising dose dependence: at low fluence, its SSNR converges to that of direct ptychography; at high fluence, it saturates at a value consistent with the maximum detective quantum efficiency predicted by recent quantum Fisher information bounds. The results highlight the limitations of CTF-based evaluation and motivate SSNR as a more accurate, finite-dose metric for assessing STEM phase retrieval methods.

STEM phase retrieval↗

Time-Resolved Neutron Imaging for Hydrogen Uptake in Subsurface Lithologies

Geologic hydrogen production and underground storage are increasingly important for meeting rising energy demands while providing clean-combustion advantages. However, hydrogen’s high diffusivity and propensity for leakage through porous media necessitate direct evaluation of its transport behavior in subsurface materials. Whereas X-ray microcomputed tomography (μCT) studies often employ contrast agents or surrogate gases, this study leverages neutron transmission radiography/CT to observe hydrogen migration in situ. This work represents the first demonstration of real-time neutron radiography of hydrogen migration in reservoir and caprock lithologies. Cylindrical cores of Indiana limestone, Amherst Gray sandstone, and Tumey shale were subjected to constant-pressure hydrogen charging and scanned in real time using high-resolution neutron radiography. Results indicate immediate hydrogen infiltration in sandstone and limestone, with homogeneous distribution detected throughout their pore structure. In contrast, hydrogen remained largely absent from fine-grained shale under the same pressure, except in an apparently localized fracture zone, where neutron signatures confirmed the presence of hydrogen. Subsequent neutron CT of the sandstone sample, using image subtraction against an uncharged reference, corroborated hydrogen distribution patterns. Even under lowpressure, single-phase conditions, distinct neutron imaging signatures of hydrogen were achieved. These preliminary findings underscore the potential of neutron imaging for advancing subsurface hydrogen migration research.

08 HYDROGEN↗