Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE TUBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Imaging Bubble Formation In a Drop Tube

Entire process under control of computer. Computer-controlled image-acquisition system tracks object, such as water bubble, as it moves in drop tube. Ultimately, such tracking system used to observe fusion-pellet formation in drop furnace.

Helizon, R.↗

Designing the Imaging and Breadboard System for FBCE-TL Project

This presentation outlines the support work done on designing the imaging and breadboard system of the Transfer Line (TL) project, which is the third module for the Flow Boiling and Condensation Experiment (FBCE) operating in the Fluids Integrated Rack on-board the International Space Station (ISS). The goal of the FBCE is to serve as a facility for flow boiling and condensation investigating two-phase flow and heat transfer data in microgravity. The TL module aims use existing FBCE hardware to study cryogenic chilldown, a large component of cryogenic propellant tank transfer research. The TL test module will perform chilldown studies with normal-perfluorohexane (nPFH), a cryogenic simulant, flowing through a super-heated line, which is heated through the process of Joule-heating. SolidWorks and Creo were used to create electrically conductive pipe junctions that connect and seal several Indium Tin Oxide (ITO) coated sapphire tube sections together to allow for low leak probability fluid flow and circumferentially uniform electrical current density. It is necessary to understand and calculate the thermal expansion of the tubing sections such that the junctions would not leak at anticipated operating temperatures and pressures, would maintain electrical contact, and not crack the crystalline tubes. Optical imaging techniques were used to build an experimentally validated image remapping process for flight-like setups of cylindrical tubes. Then MATLAB was used to create an algorithm that distorts an image based on the refraction of light passing through the mediums we were imaging through to accurately visualize the cryogenic chilldown that is of scientific interest. This research will assist NASA to move forward with long-duration spaceflight missions where knowledge of efficient heat transfer processes becomes more critical.

imaging system↗

The smoothing dissector.

A technique for adding a form of buffer store to an image dissector is described that increases markedly the photoelectron-detecting ability of the image dissector. The buffer-store function is accomplished in the phosphor screen of an image intensifier tube by the metastable electronic excitation states resulting in the phosphor screen from high-energy photoelectron bombardment. The addition of this image intensifier to an image dissector is shown to cause no nonlinearity in the input/output characteristics of the image dissector.

Eberhardt, E. H.↗

Monitoring Both Sides Of A Weld In Progress

Proposed remote vision system provides simultaneous viewing of front and back of workpiece while being welded. Enables human or automatic controller to monitor both weld pool on front and weld penetration on back. Nitrogen laser generates ultraviolet light, distributed to both sides of workpiece through two optical fiber cables. Image-intensifier tubes convert reflected ultraviolet light to visible light. Video cameras equipped with high-resolution charge-coupled devices convert visible outputs of image intensifiers into images for viewing on video monitors.

Dickinson, C. B.↗

A laboratory simulation of a single-axis dual-level precision pointing system

The laboratory simulation of a scaled single-axis dual-level control system for a large space telescope is demonstrated. The dual-level control system consists of a coarse-body-pointing system and a fine-pointing system, which uses an image motion compensator, an image dissector tube, and digital electronics. The results of the simulation indicate that the dual-level system can be used to provide tracking capability within one-tenth of a diffraction-limited image diameter of a 3-meter f/100 telescope for stars up to a +12.3 visual magnitude.

Bullock, G. F.↗

High-spatial resolution and high-spectral resolution detector for use in the measurement of solar flare hard X-rays

In the areas of high spatial resolution, the evaluation of a hard X-ray detector with 65 micron spatial resolution for operation in the energy range from 30 to 400 keV is proposed. The basic detector is a thick large-area scintillator faceplate, composed of a matrix of high-density scintillating glass fibers, attached to a proximity type image intensifier tube with a resistive-anode digital readout system. Such a detector, combined with a coded-aperture mask, would be ideal for use as a modest-sized hard X-ray imaging instrument up to X-ray energies as high as several hundred keV. As an integral part of this study it was also proposed that several techniques be critically evaluated for X-ray image coding which could be used with this detector. In the area of high spectral resolution, it is proposed to evaluate two different types of detectors for use as X-ray spectrometers for solar flares: planar silicon detectors and high-purity germanium detectors (HPGe). Instruments utilizing these high-spatial-resolution detectors for hard X-ray imaging measurements from 30 to 400 keV and high-spectral-resolution detectors for measurements over a similar energy range would be ideally suited for making crucial solar flare observations during the upcoming maximum in the solar cycle.

Desai, U. D.↗

Persistence of phosphor glow in microchannel plate image intensifiers

Image intensifier tubes using microchannel plate amplification stages and phosphor output stages are being increasingly used in various detection applications. In this paper, measurements of the decay times of what are attributed to be the P20 phosphors in various image intensifiers are reported. It is found that the long tail on the decay curve of the phosphor following illumination can be a limitation for certain observations. In addition, the background level of phosphor glow (which is seen by the subsequent detection system as a light signal) continues to build with continuing illumination.

Torr, M. R.↗

Fabry-Perot observations of comet Austin

Preliminary results of a program to observe Comet Austin (1990c1) from 16 April to 4 May and from 11 May to 27 May 1990 using the West Auxiliary of the McMath Solar Telescope on Kitt Peak, Arizona were presetned. The observations were made with a 15 cm duel-etalon Fabry-Perot scanning and imaging spectrometer with two modes of operation: a high resolution mode with a velocity resolution of 1.2 km/s and a medium resolution mode with a velocity resolution 10 km/s. Scanning data was obtained with an RCA C31034A photomultiplier tube and imaging data was obtained with a Photometrics LN2 cooled CCD camera with a 516 by 516 Ford chip. The results include: (1) information on the coma outflow velocity from high resolution spectral profiles of (OI)6300 and NH2 emissions, (2) gaseous water production rates from medium resolution observation of (OI)6300, (3) spectra of H2O(+) emissions in order to study the ionized component of the coma, (4) spatial distribution of H2O(+) emission features from sequences of velocity resolved images (data cubes), and (5) spatial distribution of (OI)6300 and NH2 emissions from medium resolution images. The field of view on the sky was 10.5 arcminutes in diameter. In the imaging mode the CCD was binned 4 by 4 resulting in 7.6 sec power pixel and a subarray readout for a field of view of 10.5 min.

Schultz, David↗

A near-infrared view of the Uranus system.

An image intensifying tube placed at the f/10 Cassegrain focus of an 88-in. reflector telescope was used together with a narrow filter centered at the 8870-A methane band to obtain near-infrared photographs of Uranus and its satellites. Good images of Uranus were obtained with a 1-min exposure, while the faintest satellite Miranda was well recorded in about one hour. The short-exposure photograph of Uranus shows that the limb is brighter than the center of the disk and brightest at the south pole. The explanation for the brightening of the limb and pole seems to be haze in the planet's upper atmosphere.

Sinton, W. M.↗

Description of a prototype emission-transmission computed tomography imaging system

We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an arc pivoted at the x-ray source. Multiple projections are obtained by rotating the object, which is mounted at the center of rotation of the system. The detector array and electronics can count up to 10(6) cps/element with sufficient energy-resolution to discriminate between x-rays at 100-120 kVp and gamma rays from 99mTc. We have used this device to acquire x-ray CT and SPECT images of a three-dimensional Hoffman brain phantom. The emission and transmission images may be superimposed in order to localize the emission image on the transmission map.

NASA Discipline Musculoskeletal↗

Infrared viewing permits human iris response studies

Infrared image converter tube and a filtered light source monitor and measure the eye of a subject during experimental task-work operations to obtain a more natural measurement of unimpeded iris response. The device permits observation in the near infrared region, with little stimulation to the eye except by normal ambient lighting.

Schnass, E. R.↗

Nematic liquid crystals for optical shutters: A concept

Nonmechanical shutter utilizes nematic crystals to attenuate illumination, thus protecting light-sensitive devices such as vidicon or image orthicon tubes and phototubes. Opacity of liquid crystals is controlled by photosensor.

Imus, R. E.↗

Image dissector development

A second-generation electrostatically focused image dissector tube for use in spacecraft attitude control star trackers is being developed with the support of an industrial contractor. Significant improvements are being made in functional characteristics, as well as in package dimensional control, tolerance of a wide variety of environmental conditions, and expected reliability over long operational lifetimes.

Goss, W. C.↗

Laser ranging system with 1-cm resolution.

A laser ranging system has been developed in which an image converter tube equipped with deflection plates is used to make a precise measurement of the fractional amount by which the time of flight of the ranging pulse exceeds an integral multiple N of the period of a stable oscillator. The value of N is determined in an auxiliary measurement. In short-range tests with a laboratory breadboard version of the system, time-of-flight uncertainties of about 45 psec were observed. The corresponding uncertainty in a range measurement is smaller than 7 mm.

Golden, K. E.↗

Advanced electro-optical imaging techniques

The papers presented at the symposium are given which deal with the present state of sensors, as may be applicable to the Large Space Telescope (LST) program. Several aspects of sensors are covered including a discussion of the properties of photocathodes and the operational imaging camera tubes.

Sobieski, S.↗