Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

WE-AB-BRA-11: Improved Imaging of Permanent Prostate Brachytherapy Seed Implants by Combining an Endorectal X-Ray Sensor with a CT Scanner

Purpose: To test feasibility of the use of a digital endorectal x-ray sensor for improved image resolution of permanent brachytherapy seed implants compared to conventional CT. Methods: Two phantoms simulating the male pelvic region were used to test the capabilities of a digital endorectal x-ray sensor for imaging permanent brachytherapy seed implants. Phantom 1 was constructed from acrylic plastic with cavities milled in the locations of the prostate and the rectum. The prostate cavity was filled a Styrofoam plug implanted with 10 training seeds. Phantom 2 was constructed from tissue-equivalent gelatins and contained a prostate phantom implanted with 18 strands of training seeds. For both phantoms, an intraoral digital dental x-ray sensor was placed in the rectum within 2 cm of the seed implants. Scout scans were taken of the phantoms over a limited arc angle using a CT scanner (80 kV, 120–200 mA). The dental sensor was removed from the phantoms and normal helical CT and scout (0 degree) scans using typical parameters for pelvic CT (120 kV, auto-mA) were collected. A shift-and add tomosynthesis algorithm was developed to localize seed plane location normal to detector face. Results: The endorectal sensor produced images with improved resolution compared to CT scans. Seed clusters and individual seed geometry were more discernable using the endorectal sensor. Seed 3D locations, including seeds that were not located in every projection image, were discernable using the shift and add algorithm. Conclusion: This work shows that digital endorectal x-ray sensors are a feasible method for improving imaging of permanent brachytherapy seed implants. Future work will consist of optimizing the tomosynthesis technique to produce higher resolution, lower dose images of 1) permanent brachytherapy seed implants for post-implant dosimetry and 2) fine anatomic details for imaging and managing prostatic disease compared to CT images. Funding: LSU Faculty Start-up Funding. Disclosure: XDR Radiography has loaned our research group the digital x-ray detector used in this work. CoI: None.

60 APPLIED LIFE SCIENCES↗

Dietary omega-3 and -6 fatty acids affect the expression of prostaglandin E2 synthesis enzymes and receptors in mice uteri during the window of pre-implantation

Highlights: • Dietary omega-3 and -6 could affect uterine expression of PGE pathway especially mPGES and EP2 during pre-implantation period. • Uterine expression of mPGES and EP2 on the day of implantation has a positive correlation with implantation rate. • One of the important mechanisms of PUFA in affecting female pregnancy is through mPGES and EP2. Considering possible effects of poly-unsaturated fatty acids (PUFA) on embryo implantation more likely through PGs, we investigated effects of dietary omega-3 and -6 PUFA on prostaglandin E2 (PGE2) signaling in mice uterus during pre-implantation period. The mRNA expressions of microsomal- and cytosolic- PGE synthase (mPGES and cPGES) and protein expressions of PGE receptor 2 and 4 (EP2 and EP4) were evaluated in uterus tissues of control as well as omega 3 and omega 6 received mice at days 1–5 of pregnancy. Expression of cPGES gene was not significantly different between groups but the mPGES expression on days 4 and 5 of pregnancy in supplemented groups was higher than controls. Omega-3 significantly decreased EP2 levels on days 3 and 4, while omega-6 caused an increase on days 3–5 of pregnancy. The levels of EP4 were significantly higher in the omega-6 group than other groups on days 4 and 5 of pregnancy. Also the implantation rate was higher in omega -6 compared to omega-3 group (p = 0.006). Moreover, there were significant correlations between implantation rate with expression levels of mPGES and EP2. Our results showed negative and positive effects of respectively dietary omega-3 and -6 PUFA on PGE2 signaling and implantation rate.

60 APPLIED LIFE SCIENCES↗

Analysis of strain in ion implanted 4H-SiC by fringes observed in synchrotron X-ray topography

A novel high energy implantation system has been successfully developed to fabricate 4H-SiC superjunction devices for medium and high voltage via implantation of dopant atoms with multi-energies ranging from 13 to 66 MeV. The significantly higher levels of energy used compared to conventional implantation processes, necessitates detailed characterization of the lattice damage caused by implantation. To achieve this by employing the novel high energy system, 4H-SiC wafer with 12 μm epilayers were blanket implanted by 13.8–65.7 MeV Al atoms. The lattice damages induced by the implantation were primarily characterized by Synchrotron X-ray Plane Wave Topography (SXPWT) and Reciprocal Space Mapping (RSM). Topographs reveal fringe contrast akin to multiple asymmetric diffraction peaks with an angular separation of only 2″ (arcseconds) observed on rocking curves, indicating inhomogeneous strain distribution across the implanted layer. The strain profile of the implanted layer was extracted from the fringe contrast by applying Rocking-curve Analysis by Dynamical Simulation (RADS). In conclusion, the maximum strain value is similar to that measured on the RSM.

A1. Characterization↗

p-type conductivity and damage recovery in implanted GaN annealed by rapid gyrotron microwave annealing

We demonstrate p-type activation of GaN doped by Mg ion implantation, and in situ during metalorganic chemical vapor deposition through sequential short-duration gyrotron microwave heating cycles at temperatures of 1200–1350 °C. GaN is implanted with 1019 cm−3 Mg ions, capped with AlN, and annealed under 3 MPa N2 overpressure in 5 s heating cycles for less than 60 s total using a high-power gyrotron microwave heating source. Through I–V characterization, photoluminescence spectroscopy, and Raman spectroscopy, we study the evolution of electrical properties, optically active point defects, and material strain in response to implantation and annealing. For Mg-implanted samples, increasing annealing temperature is characterized by an increase in the PL substitutional Mg-related peak (UVL) relative to the shallow-donor vacancy-related peak (GL2). Through comparison of implanted and in situ doped samples, it is demonstrated that the origin of compensating VN lies primarily in implantation rather than degradation from the annealing process. Transmission line measurements and diode I–V measurements show a sheet resistance of 1083 kΩ/□ and a hole concentration of 1.23 × 1015 cm−3, respectively, in the Mg-implanted material annealed at 1350 °C. We conclude that temperature-cycled gyrotron annealing at 1350 °C decreases implant-induced compensating point defects and activates Mg to obtain selective p-type conduction.

Meyers, V. (ORCID:0000000176731553)↗

Study of the effects of MeV Ag, Cu, Au, and Sn implantation on the optical properties of LiNbO3

The authors present the results of characterization of linear absorption and nonlinear refractive index of Au, Ag, Cu and Sn ion implantation into LiNbO3. Ag was implanted at 1.5 MeV to fluences of 2 to 17 x 17(exp 16)/sq cm at room temperature. Au and Cu were implanted to fluences of 5 to 20 x 10(exp 16)/sq cm at an energy of 2.0 MeV. Sn was implanted to a fluence of 1.6 x 10(exp 17)/sq cm at 160 kV. Optical absorption spectrometry indicated an absorption peak for the Au implanted samples after heat treatment at 1,000 C at approx. 620 nm. The Ag implanted samples absorption peaks shifted from approx. 450 nm before heat treatment to 550 nm after 500 C for 1h. Heat treatment at 800 C returned the Ag implanted crystals to a clear state. Cu nanocluster absorption peaks disappears at 500 C. No Sn clusters were observed by optical absorption or XRD. The size of the Ag and Au clusters as a function of heat treatment were determined from the absorption peaks. The Ag clusters did not change appreciably in size with heat treatment. The Au clusters increased from 3 to 9 nm diameter upon heat treatment at 1000 C. TEM analysis performed on a Au implanted crystal indicated the formation of Au nanocrystals with facets normal to the c-axis. Measurements of the nonlinear refractive indices were carried out using the Z-scan method with a tunable dye laser pumped by a frequency doubled mode-locked Nd:YAG laser. The dye laser had a 4.5 ps pulse duration time and 76 MHz pulse repetition rate (575 nm).

Williams, E. K.↗

Neuro-Prosthetic Implants With Adjustable Electrode Arrays

Brushlike arrays of electrodes packaged with application-specific integrated circuits (ASICs) are undergoing development for use as electronic implants especially as neuro-prosthetic devices that might be implanted in brains to detect weak electrical signals generated by neurons. These implants partly resemble the ones reported in Integrated Electrode Arrays for Neuro-Prosthetic Implants (NPO-21198), NASA Tech Briefs, Vol. 27, No. 2 (February 2003), page 48. The basic idea underlying both the present and previously reported implants is that the electrodes would pick up signals from neurons and the ASICs would amplify and otherwise preprocess the signals for monitoring by external equipment. The figure presents a simplified and partly schematic view of an implant according to the present concept. Whereas the electrodes in an implant according to the previously reported concept would be microscopic wires, the electrodes according to the present concept are in the form of microscopic needles. An even more important difference would be that, unlike the previously reported concept, the present concept calls for the inclusion of microelectromechanical actuators for adjusting the depth of penetration of the electrodes into brain tissue. The prototype implant now under construction includes an array of 100 electrodes and corresponding array of electrode contact pads formed on opposite faces of a plate fabricated by techniques that are established in the art of microelectromechanical systems (MEMS). A mixed-signal ASIC under construction at the time of reporting the information for this article will include 100 analog amplifier channels (one amplifier per electrode). On one face of the mixed-signal ASIC there will be a solder-bump/micro-pad array that will have the same pitch as that of the electrode array, and that will be used to make the electrical and mechanical connections between the electrode array and the ASIC. Once the electrode array and the ASIC are soldered together, the remaining empty space between them will be filled with a biocompatible epoxy, the remaining exposed portions of the ASIC will be covered with micromachined plates for protection against corrosive bodily fluids, and then the ASIC and its covering micromachined plates will be coated with parylene

Whitacre, Jay↗

Nissin Ion Doping System--H{sub 2}{sup +} Implantation for Silicon Layer Exfoliation

A Nissin iG4 ion doping system (termed iG4) utilizes broad beam technology to implant GEN 4 sheets of glass for LCD production. The mechanical scanned end-station with robotic handling for GEN 4 glass substrates was redesigned, and a new end-station was built to handle rectangular silicon tiles (23x18 cm). A three sub-system modular risk reduction process was used to test production solutions, and maximize the success of transferring the R and D implant recipes developed on a standard focused beam ion implanter to the Nissin broad beam iG4 solution. The silicon tile end-station including the implant scanning system was tested for reliability and durability. The end-station handled rectangular silicon tiles reliably without detrimental edge chipping or silicon breakage. The ion optics was demonstrated to successfully provide stable hydrogen ions for the Corning registered silicon on glass layer transfer process. This layer transfer process is very susceptible and sensitive to the implant processing temperature. The temperature excursions during implant processing for the iG4 exfoliation process were found to be in line with the R and D focused ion beam system. This data confirmed the system production-readiness in providing an efficient solution for the high volume production of hydrogen implanted silicon rectangular tiles.

36 MATERIALS SCIENCE↗

Method For Silicon Surface Texturing Using Ion Implantation

As the semiconductor industry continues to show more interest in the photovoltaic market, cheaper and readily integrable methods of silicon solar cell production are desired. One of these methods - ion implantation - is well-developed and optimized in all commercial semiconductor fabrication facilities. Here we have developed a silicon surface texturing technique predicated upon the phenomenon of surface blistering of H-implanted silicon, using only ion implantation and thermal annealing. We find that following the H implant with a second, heavier implant markedly enhances the surface blistering, causing large trenches that act as a surface texturing of c-Si. We have found that this method reduces total broadband Si reflectance from 35% to below 5percent;. In addition, we have used Rutherford backscattering/channeling measurements investigate the effect of ion implantation on the crystallinity of the sample. The data suggests that implantation-induced lattice damage is recovered upon annealing, reproducing the original monocrystalline structure in the previously amorphized region, while at the same time retaining the textured surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enhanced light extraction efficiency of GaN-based light-emittng diodes by nitrogen implanted current blocking layer

Highlights: • A nitrogen implanted current-blocking layer was successfully demonstrated. • Light-extraction efficiency and radiant intensity was increased by more than 20%. • Ion implantation was successfully implemented in GaN based light-emitting diodes. - Abstract: GaN-based light emitting diodes (LEDs) with a nitrogen implanted current-blocking layer (CBL) were successfully demonstrated for improving the light extraction efficiency (LEE) and radiant intensity. The LEE and radiant intensity of the LEDs with a shallow implanted CBL with nitrogen was greatly increased by more than 20% compared to that of a conventional LED without the CBL due to an increase in the effective current path, which reduces light absorption at the thick p-pad electrode. Meanwhile, deep implanted CBL with a nitrogen resulted in deterioration of the LEE and radiant intensity because of formation of crystal damage, followed by absorption of the light generated at the multi-quantum well(MQW). These results clearly suggest that ion implantation method, which is widely applied in the fabrication of Si based devices, can be successfully implemented in the fabrication of GaN based LEDs by optimization of implanted depth.

36 MATERIALS SCIENCE↗

Dosimetric comparison between model 9011 and 6711 sources in prostate implants

The purpose of this work is to evaluate the model 9011 iodine-125 ({sup 125}I) in prostate implants by comparing dosimetric coverage provided by the 6711 vs 9011 source implants. Postimplant dosimetry was performed in 18 consecutively implanted patients with prostate cancer. Two were implanted with the 9011 source and 16 with the 6711 source. For purposes of comparison, each implant was then recalculated assuming use of the other source. The same commercially available planning system was used and the specific source data for both 6711 and 9011 products were entered. The results of these calculations are compared side by side in the terms of the isodose values covering 100% (D100) and 90% (D90) of prostate volume, and the percentages of volumes of prostate, bladder, rectum, and urethra covered by 200% (V200), 150% (V150), 100% (V100), 50% (V50), and 20% (V20) of the prescribed dose as well. The 6711 source data overestimate coverage by 6.4% (ranging from 4.9% to 6.9%; median 6.6%) at D100 and by 6.6% (ranging from 6.2% to 6.8%; median 6.6%) at D90 compared with actual 9011 data. Greater discrepancies of up to 67% are seen at higher dose levels: average reduction for V100 is 2.7% (ranging from 0.6% to 7.7%; median 2.3%), for V150 is 14.6% (ranging from 6.1% to 20.5%; median 15.3%), for V200 is 14.9% (ranging from 4.8% to 19.1%; median 16%); similarly seen in bladder, rectal, and urethral coverage. This work demonstrates a clear difference in dosimetric behavior between the 9011 and 6711 sources. Using the 6711 source data for 9011 source implants would create a pronounced error in dose calculation. This study provides evidence that the 9011 source can provide the same dosimetric quality as the 6711 source, if properly used; however, the 6711 source data should not be considered as a surrogate for the 9011 source implants.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reduced boron diffusion under interstitial injection in fluorine implanted silicon

Point defect injection studies are performed to investigate how fluorine implantation influences the diffusion of boron marker layers in both the vacancy-rich and interstitial-rich regions of the fluorine damage profile. A 185 keV, 2.3x10{sup 15} cm{sup -2} F{sup +} implant is made into silicon samples containing multiple boron marker layers and rapid thermal annealing is performed at 1000 deg. C for times of 15-120 s. The boron and fluorine profiles are characterized by secondary ion mass spectroscopy and the defect structures by transmission electron microscopy (TEM). Fluorine implanted samples surprisingly show less boron diffusion under interstitial injection than those under inert anneal. This effect is particularly noticeable for boron marker layers located in the interstitial-rich region of the fluorine damage profile and for short anneal times (15 s). TEM images show a band of dislocation loops around the range of the fluorine implant and the density of dislocation loops is lower under interstitial injection than under inert anneal. It is proposed that interstitial injection accelerates the evolution of interstitial defects into dislocation loops, thereby giving transient enhanced boron diffusion over a shorter period of time. The effect of the fluorine implant on boron diffusion is found to be the opposite for boron marker layers in the interstitial-rich and vacancy-rich regions of the fluorine damage profile. For marker layers in the interstitial-rich region of the fluorine damage profile, the boron diffusion coefficient decreases with anneal time, as is typically seen for transient enhanced diffusion. The boron diffusion under interstitial injection is enhanced by the fluorine implant at short anneal times but suppressed at longer anneal times. It is proposed that this behavior is due to trapping of interstitials at the dislocation loops introduced by the fluorine implant. For boron marker layers in the vacancy-rich region of the fluorine damage profile, suppression of boron diffusion is seen for short anneals and then increased diffusion after a critical time, which is longer for inert anneal than interstitial injection. This behavior is explained by the annealing of vacancy-fluorine clusters, which anneal quicker under interstitial injection because the injected interstitials annihilate vacancies in the clusters.

36 MATERIALS SCIENCE↗

Amorphous Ge quantum dots embedded in SiO{sub 2} formed by low energy ion implantation

Under ultrahigh vacuum conditions, extremely small Ge nanodots embedded in SiO{sub 2}, i.e., Ge-SiO{sub 2} quantum dot composites, have been formed by ion implantation of {sup 74}Ge{sup +} isotope into (0001) Z-cut quartz at a low kinetic energy of 9 keV using varying implantation temperatures. Transmission electron microscopy (TEM) images and micro-Raman scattering show that amorphous Ge nanodots are formed at all temperatures. The formation of amorphous Ge nanodots is different from reported crystalline Ge nanodot formation by high energy ion implantation followed by a necessary high temperature annealing process. At room temperature, a confined spatial distribution of the amorphous Ge nanodots can be obtained. Ge inward diffusion was found to be significantly enhanced by a synergetic effect of high implantation temperature and preferential sputtering of surface oxygen, which induced a much wider and deeper Ge nanodot distribution at elevated implantation temperature. The bimodal size distribution that is often observed in high energy implantation was not observed in the present study. Cross-sectional TEM observation and the depth profile of Ge atoms in SiO{sub 2} obtained from x-ray photoelectron spectra revealed a critical Ge concentration for observable amorphous nanodot formation. The mechanism of formation of amorphous Ge nanodots and the change in spatial distribution with implantation temperature are discussed.

36 MATERIALS SCIENCE↗

Implantation conditions for diamond nanocrystal formation in amorphous silica

We present a study of carbon ion implantation in amorphous silica, which, followed by annealing in a hydrogen-rich environment, leads to preferential formation of carbon nanocrystals with cubic diamond (c-diamond), face-centered cubic (n-diamond), or simple cubic (i-carbon) carbon crystal lattices. Two different annealing treatments were used: furnace annealing for 1 h and rapid thermal annealing for a brief period, which enables monitoring of early nucleation events. The influence of implanted dose and annealing type on carbon and hydrogen concentrations, clustering, and bonding were investigated. Rutherford backscattering, elastic recoil detection analysis, infrared spectroscopy, transmission electron microscopy, selected area electron diffraction, ultraviolet-visible absorption measurements, and Raman spectroscopy were used to study these carbon formations. These results, combined with the results of previous investigations on similar systems, show that preferential formation of different carbon phases (diamond, n-diamond, or i-carbon) depends on implantation energy, implantation dose, and annealing conditions. Diamond nanocrystals formed at a relatively low carbon volume density are achieved by deeper implantation and/or lower implanted dose. Higher volume densities led to n-diamond and finally to i-carbon crystal formation. This observed behavior is related to damage sites induced by implantation. The optical properties of different carbon nanocrystal phases were significantly different.

36 MATERIALS SCIENCE↗

Characterization of Charging Control of a Single Wafer High Current Spot Beam Implanter

This paper focuses on the characterization of charging control of an Axcelis Optima HD single wafer high current spot beam implanter using MOS capacitors with attached antennas of different size and shape. Resist patterns are implemented on Infineon Technologies own charging control wafers to investigate the influence of photo resist on charging damage. Compared to batch high current implanters the design of the beamline and the beam shape are comparable to single wafer high current spot beam implanters, however due to the different scanning architecture the dose rate of the single wafer high current spot beam implanters is significantly higher compared to the batch tools. Therefore, the risk of charging damage will be higher. The charging damage was studied as a function of the energy, the beam current and the most important plasma flood gun parameters. The results have shown that for very high antenna ratios the charging damage for single wafer implanters, even spot or ribbon beam implanters, is higher than for high current batch implanters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accurate Dose Control with Pressure Compensation System on Single-Wafer Ion Implanters

On ion implanters, dosimetry is generally controlled by monitoring an electrical current detected with Faraday cup(s) instead of the actual number of dopants. In some cases, ions in a beam undergo charge exchange phenomenon, interacting with residual gas molecules in a beamline. This charge exchange of ions causes variations of the detected beam currents which result in inaccurate dosimetry of implanted dopants. We will introduce to you a system similar to Pressure Compensation of the batch-type ion implanters to single-wafer ion implanters, that is, the SHX high current ion implanter and the MC3-II medium current ion implanter. The system converts the beam current detected with Faraday cups to an adequate value for dose control as a function of beamline pressure and brings accurate dosimetry also in these single-wafer ion implanters.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characteristics of Cluster Implantation and Low Diffusion Annealing

Beyond 45 nm device fabrication, it is recognized that the ultra-shallow junction (USJ) formation is required, which is achieved by the ultra-low energy ion implantation and ultra-low diffusion annealing. For this purpose, Cluster ion implantation (CII) and the Flash lamp annealing (FLA) activation processes have been developed. In this paper, we introduce characteristics of activation using B{sub 18}Hx{sup +} implantation with FLA, which are applied to a source drain extension (SDE) for pMOSFET in Hgh-k/metal process. We will prove that the combined process of B{sub 18}Hx{sup +} and FLA can make the low sheet resistance and the fine crystal recovery for USJ formation such a SDE. Moreover, the combined process of C{sub 7}Hx{sup +} implantation and FLA can make the high stress region for nMOSFET by the high substitutional Carbon. If both of B{sub 18}Hx{sup +} implantation and C{sub 7}Hx{sup +} implantation with FLA are applied to High-k/metal process, it will give the highest performance. The combination of FLA and cluster ion implanter ''CLARIS'' which is developed for IC fabrication, will promise the most powerful performance beyond 45 nm node device.

36 MATERIALS SCIENCE↗

Diluted magnetic semiconductor effects in Mn-implanted silicon carbide

Light transmission and Faraday rotation spectra measured at the temperature of 2 K were compared for silicon carbide single crystals of 4H polytype (4H-SiC), implanted with 3.8 x 10{sup 16} cm{sup -2} of Mn ions at the beam energy of 190 keV, and a control 4H-SiC single crystal sample, which was not implanted. Mn ion implantation led to the creation of a Mn-doped surface layer with the average Mn concentration of 10{sup 21} cm{sup -3} and a thickness of approximately 0.2 {mu}m. Transmission of light through the implanted crystal changed only slightly in comparison with the control sample, which however, corresponded to a relatively strong attenuation in the implanted layer. This was interpreted as a result of scattering, which emerges in the surface layer due to optical nonuniformities, created by the high energy ion irradiation. The presence of a thin Mn-ion-containing surface layer led, despite its small thickness, to noticeable changes in the sample Faraday rotation spectra. The estimated values of the Verdet constant for this layer were about three orders of magnitude larger and of opposite sign compared to the Verdet constant values of the undoped sample. Magnetic field dependencies of the Faraday rotation contribution from the implanted layer were found to be saturating functions, which points to a proportionality of the Faraday rotation to the magnetization of the paramagnetic Mn ion subsystem. Based on these findings we conclude that the Mn-implanted SiC layer exhibits magneto-optical properties typical of a diluted magnetic semiconductor. At the same time, no ferromagnetic ordering was observed in the studied (Si, Mn)C sample.

36 MATERIALS SCIENCE↗

Modeling of nanocluster formation by ion beam implantation

A theoretical model was developed to investigate the mechanism of the formation of nanoclusters via ion beam implantation. The evolution of nanoclusters, including the nucleation and growth process known as Ostwald ripening, was rebuilt using numerical simulations. The effects of implantation parameters such as the ion energy, ion fluence, and temperature on the morphology of implanted microstructures were also studied through integration with the Monte Carlo Transport of Ions in Matter code calculation for the distribution profiles of implanted ions. With an appropriate ion fluence, a labyrinth-like nanostructure with broad size distributions of nanoclusters formed along the ion implantation range. In a latter stage, a buried layer of implanted impurity developed. With decreasing ion energy, the model predicted the formation of precipitates on the surface. These simulation results were fully consistent with many experimental observations. With increased temperature, the characteristic length and size of nanostructures would increase due to the high mobility. This theoretical model provides an efficient numerical approach for fully understanding the mechanism of the formation of nanoclusters, allowing for the design of ion beam experiments to form specific nanostructures through ion-implantation technology.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗