Search NASA⌕ Search

SEARCH · Search NASA

Results for “INCIDENT RAY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

HAZMAT. IX. An Analysis of the UV and X-Ray Evolution of Low-mass Stars in the Era of Gaia

Low-mass stars (≤1 M⊙) are some of the best candidates for hosting planets with detectable life because of these stars' long lifetimes and relative ratios of planet to star mass and radius. An important aspect of these stars to consider is the amount of ultraviolet (UV) and X-ray radiation incident on planets in the habitable zones due to the ability of UV and X-ray radiation to alter the chemistry and evolution of planetary atmospheres. In this work, we build on the results of the HAZMAT I and HAZMAT III M-star studies to determine the intrinsic UV and X-ray flux evolution with age for M stars using Gaia parallactic distances. We then compare these results to the intrinsic fluxes of K stars adapted from HAZMAT V. We find that although the intrinsic M-star UV flux is 10–100 times lower than that of K stars, the UV fluxes in their respective habitable zone are similar. However, the habitable zone X-ray flux evolutions are slightly more distinguishable with a factor of 3–15 times larger X-ray flux for late M stars than for K stars. These results suggest that there may not be a K-dwarf advantage compared to M stars in the UV, but one may still exist in the X-ray.

stars↗

Direct Observation of Morphological and Chemical Changes during the Oxidation of Model Inorganic Ligand-Capped Particles

Functionalization and volatilization are competing reactions during the oxidation of carbonaceous materials and are important processes in many different areas of science and technology. Here, we present a combined ambient pressure X-ray photoelectron spectroscopy (APXPS) and grazing incidence X-ray scattering (GIXS) investigation of the oxidation of oleic acid ligands surrounding NaYF 4 nanoparticles (NPs) deposited onto SiO x /Si substrates. While APXPS monitors the evolution of the oxidation products, GIXS provides insight into the morphology of the ligands and particles before and after the oxidation. Our investigation shows that the oxidation of the oleic acid ligands proceeds at O 2 partial pressures of below 1 mbar in the presence of X-rays, with the oxidation eventually reaching a steady state in which mainly CH x and –COOH functional groups are observed. The scattering data reveal that the oxidation and volatilization reaction proceeds preferentially on the side of the particle facing the gas phase, leading to the formation of a chemically and morphologically asymmetric ligand layer. This comprehensive picture of the oxidation process could be obtained only by combining the X-ray scattering and APXPS data. The investigation presented here lays the foundation for further studies of the stability of NP layers in the presence of reactive trace gases and ionizing radiation and for other nanoscale systems where chemical and morphological changes happen simultaneously and cannot be understood in isolation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gamma rays of 0.3 to 30 MeV from PSR 0531+21

Pulsed gamma rays from the Crab Pulsar PSR 0531+21 are reported for energies of 0.3 to 30 MeV. The observations were carried out with the UCR gamma ray double Compton scatter telescope launched on a balloon from Palestine, Texas at 4.5 GV, at 2200 LT, September 29, 1978. Two 8 hr observations of the pulsar were made, the first starting at 0700 UT (0200 LT) September 30 just after reaching float altitude of 4.5 g/sq cm. Analysis of the total gamma ray flux from the Crab Nebula plus pulsar using telescope vertical cell pairs was published previously. The results presented supersede the preliminary ones. The double scatter mode of the UCR telescope measures the energy of each incident gamma ray from 1 to 30 MeV and its incident angle to a ring on the sky. The time of arrival is measured to 0.05 ms. The direction of the source is obtained from overlapping rings on the sky. The count rate of the first scatter above a threshold of 0.3 MeV is recorded every 5.12 ms. The Crab Pulsar parameters were determined from six topocentric arrival times of optical pulses.

White, R. S.↗

Interaction of space radiation with matter

The physical interactions of high-energy space radiations with bulk matter are described with particular emphasis on the nuclear and electromagnetic interactions of solar and galactic cosmic rays. Methods of incorporating these interactions into radiation transport models which accurately describe the propagation of the incident cosmic rays and their subsequent-generation reaction products are also explained. Representative results for solar and galactic cosmic ray doses and dose equivalents are presented for various aluminum and water absorber depths. For the first time, the main contributions to human exposure in space from galactic cosmic rays will be presented on a component by component basis, including a breakdown of the dose-equivalent contributions into primary ions, heavy fragments, alpha particles, neutrons, and protons. For the galactic cosmic ray environment outside of the earth's magnetosphere, over 70 percent of the total dose equivalent results from only seven nuclear species (hydrogen, helium, carbon, oxygen, silicon, magnesium, and iron ions). Of these, the largest single contributor is cosmic ray iron and its secondaries, which account for nearly one-fourth of the unshielded total dose equivalent during solar minimum.

Townsend, L. W.↗

Calibration of the High Energy Replicated Optics to Explore the Sun (HEROES) Hard X-ray Telescope

On September 21-22, 2013, the High Energy Replicated Optics to Explore the Sun (HEROES) hard X-ray telescope, flew as a balloon payload from Ft. Sumner, N.M. HEROES observed the Sun, the black hole binary GRS 1915+105, and the Crab Nebula during its 27 hour flight. In this paper we describe laboratory calibration measurements of the HEROES detectors using line and continuum sources, applications of these measurements to define channel to energy (gain) corrections for observed events and to define detector response matrices. We characterize the HEROES X-ray grazing incidence optics using measurements taken in the Stray-Light (SLF) Facility in Huntsville, AL, and using ray traces.

Wilson-Hodge, Colleen A.↗

X-ray scattering study

A soft X-ray glancing incidence telescope mirror and a group of twelve optical flat samples were used to study the scattering of X-rays. The mirror was made of Kanigen coated beryllium and the images produced were severely limited by scattering of X-rays. The best resolution attained was about fifteen arc seconds. The telescope efficiency was found to be 0.0006. The X-ray beam reflected from the twelve optical flat samples was analyzed by means of a long vacuum system of special design for these tests. The scattering then decreased with increasing angle of incidence until a critical angle was passed. At larger angles the scattering increased again. The samples all scattered more at 44 A than at 8 A. Metal samples were found to have about the same scattering at 44 A but greater scattering at 8 A than glass samples.

Wriston, R. S.↗

ISEE-C HKH high energy cosmic rays

The paper describes the ISEE-C multidetector cosmic ray telescope experiment. The HKH particle identifier sensor array is designed to identify the charge and mass of incident cosmic ray nuclei from H-1 to Ni-64 over the energy range of approximately 20 to 500 MeV/nucleon. Particle identification is based on the multiple energy loss technique. The scientific aspects of the experiment are briefly reviewed and consideration is given to the flight hardware, including sensors, event encoding, buffer memory, redundancy and commandability, and packaging.

Greiner, D. E.↗

Wolter Optics for Neutron Focusing

Focusing optics based on Wolter optical geometries developed for x-ray grazing incidence beams can be designed for neutron beams. Wolter optics are formed by grazing incidence reflections from two concentric conic sections (for example, a paraboloid and a hyperboloid). This has transformed observational X-ray astronomy by increasing the sensitivity by many orders of magnitude for research in astrophysics and cosmology. To increase the collection area, many reflecting mirrors of different diameters are nested with a common focal plane. These mirrors are fabricated using nickel-electroformed replication techniques. We apply these ideas to neutron focusing using nickel mirrors. We show an initial test of a conical mirror using a beam of cold neutrons. key words: electroformed nickel replication, focusing optics, grazing angle incidence, mirror reflection, neutron focusing, Wolter optics

Mildner, D. F. R.↗

Controlling Ion Uptake in Carboxylated Mixed Conductors

Organic mixed ionic‐electronic conductors (OMIECs) have garnered significant attention due to their capacity to transport both ions and electrons, making them ideal for applications in energy storage, neuromorphics, and bioelectronics. However, charge compensation mechanisms during the polymer redox process remain poorly understood, and are often oversimplified as single‐ion injection with little attention to counterion effects. To advance understanding and design strategies toward next‐generation OMIEC systems, a series of p‐channel carboxylated mixed conductors is investigated. Varying side‐chain functionality, distinctive swelling character is uncovered during electrochemical doping/dedoping with model chao‐/kosmotropic electrolytes. Carboxylic acid functionalized polymers demonstrate strong deswelling and mass reduction during doping, indicating cation expulsion, while ethoxycarbonyl counterparts exhibit prominent mass increase, pointing to an anion‐driven doping mechanism. By employing operando grazing incidence X‐ray fluorescence (GIXRF), it is revealed that the carboxyl functionalized polymer engages in robust cation interaction, whereas ester functionalization shifts the mechanism towards no cation involvement. It is demonstrated that cations are pivotal in mitigating swelling by counterbalancing anions, enabling efficient anion uptake without compromising performance. These findings underscore the transformative influence of functionality‐driven factors and side‐chain chemistry in governing ion dynamics and conduction, providing new frameworks for designing OMIECs with enhanced performance and reduced swelling.

carboxylated polythiophenes↗

Hybrid X-ray telescope systems

It has been known for some time that glancing incidence X-ray optics have sharply peaked point response functions. The spatial resolution of Wolter X-ray telescope systems is frequently limited by the performance characteristics of the X-ray detector rather than by the optics, even when high resolution detectors such as photographic emulsions are used. This problem becomes even more severe when it is desirable to take advantage of the high sensitivity and broad wavelength response afforded by modern solid state detectors such as charge coupled devices or multi-anode microchannel arrays. Results of theoretical investigations of methods for increasing the telescope plate scale by the use of glancing incidence hyperboloid/ellipsoid X-ray microscope optics and normal incidence contoured layered synthetic microstructure optics for coupling the Wolter mirrors to the detector are reported. The relative merits of the different hybrid X-ray telescope systems which result will be discussed. Considerations will be made concerning applications of these systems to high resolution imagery and spectroscopy of astronomical X-ray/XUV sources.

Shealy, David L.↗

X-ray/EUV optics for astronomy and microscopy; Proceedings of the Meeting, San Diego, CA, Aug. 7-11, 1989

Topics included in these proceedings are on X-ray/EUV zone plates, filters, and windows; X-ray/EUV microscopes, telescopes, and monochromators; the design, characterization, and test of multilayer optics; the fabrication of X-ray/EUV multilayer optics; and the design, characterization, and test of grazing incidence X-ray optics. Other topics are on the fabrication of grazing incidence X-ray optics, X-ray/EUV space observatories and missions, the test and calibration of X-ray/EUV instruments, X-ray polarimetry, and X-ray/EUV spectroscopy and instruments. Papers are presented on 8-keV X-ray zone plates, a cylindrical X-ray multilayer monochromator, multilayer mirrors for 182 A, advanced flow polishing of exotic optical materials, and optical analysis of grazing incidence ring resonators for free-electron lasers. Attention is also given to X-ray mirrors for the European Synchrotron Radiation Facility, the XUV wide-field camera for Rosat, an optical test and alignment method for the XMM mirror module, Bragg crystal polarimeters, and a liftoff process for multilayer phase gratings.

Hoover, Richard B.↗

Figure Measurements of High-Energy-X-Ray Replicated Optics

We are developing grazing incidence x-ray optics for a balloon-borne hard-x-ray telescope (HERO). The HERO mirror shells are fabricated using electroform-nickel replication off super-polished cylindrical mandrels. One of the sources for mirror resolution error is departure of the shell figure from prescription. We have modified a Vertical-scan Long Trace Profilometer (VLTP) in order to measure the figure of the inner surface of the HERO mirror shells for diameters as small as 76 mm. Mirror alignment method and sources for systematic errors will be discussed. Comparison of figure metrology of the mandrel and the shells will be presented together with results from x-ray tests.

Gubarev, Mikhail↗

Alignment, Assembly and Testing of High Energy X-Ray Optics

We are developing grazing-incidence x-ray imaging optics for a balloon-borne hard x-ray telescope (HERO). The HERO payload, scheduled for launch in May 2005, currently consists of 8 mirror modules each containing 12 mirror shells fabricated using electroform-nickel replication off super-polished cylindrical mandrels. An optical system developed for aligning and assembling the shells in the modules will be described. Sources for systematic errors associated with this process will be discussed and results from on-ground x-ray testing of each module will be presented.

Gubarev, Mikhail↗

Mounting and Alignment of Full-Shell Replicated X-Ray Optics

We are developing grazing-incidence x-ray optics for astronomy. The optics are full-cylinder mirror shells fabricated using electroformed-nickel replication off super-polished mandrels. For space-based applications where weight is at a premium, very-thin-walled, light-weight mirrors are required. Such shells have been fabricated at MSFC with greater than 15 arcsec resolution. The challenge, however, is to preserve this resolution during mounting and assembly. We present here a status report on a mounting and alignment system currently under development at Marshall Space Flight Center to meet this challenge.

Gubarev, Mikhail↗

Alignment System for Full-Shell Replicated X-Ray Mirrors

We are developing grazing-incidence x-ray optics for high-energy astrophysical applications using the electroformnickel replication process. For space-based applications these optics must be light-weight yet stable, which dictates the use of very-thin-walled full-shell mirrors. Such shells have been fabricated with resolution as good as 11 arcsec for hard x-rays, and technology enhancements under development at MSFC are aimed at producing mirrors with resolution better than 10 arcsec. The challenge, however, is to preserve this resolution during mounting and assembly. We present here a status report on a mounting and alignment system currently under development at Marshall Space Flight Center designed to meet this challenge.

Gubarev, Mikhail↗

Measurement of the point spread function and effective area of the Solar-A Soft X-ray Telescope mirror

A grazing incidence solar X-ray telescope, Soft X-ray Telescope (SXT), will be flown on the Solar-A satellite in 1991. Measurements have been conducted to determine the focal length, Point Spread Function (PSF), and effective area of the SXT mirror. The measurements were made with pinholes, knife edges, a CCD, and a proportional counter. The results show the 1/r character of the PSF, and indicate a half power diameter of 4.9 arcsec and an effective area of 1.33 sq cm at 13.3 A (0.93 keV). The mirror was found to provide a high contrast image with very little X-ray scattering.

Lemen, J. R.↗

Event Selection and Background Rejection in Time Projection Chambers Using Convolutional Neural Networks and a Specific Application to the AdEPT Gamma-ray Polarimeter Mission

The Advanced Energetic Pair Telescope gamma-ray polarimeter uses a time projection chamber for measuring pair production events and is expected to generate a raw instrument data rate four orders of magnitude greater than is transmittable with typical satellite data communications. GammaNet, a convolutional neural network, proposes to solve this problem by performing event classification on-board for pair production and background events, reducing the data rate to a level that can be accommodated by typical satellite communication systems. In order to train GammaNet, a set of 1.1 × 10(exp 6) pair production events and 10(exp 6) background events were simulated for the Advanced Energetic Pair Telescope using the Geant4 Monte Carlo code. An additional set of 10(exp 6) pair production and 10 background events were simulated to test GammaNet’s capability for background discrimination. With optimization, GammaNet has achieved the proposed background rejection requirements for Galactic Cosmic Ray proton events. Given the best case assumption for downlink speeds, signal sensitivity for pair production ranged between 1.1 ± 0.5% to 69 ± 2% for 5 and 250 MeV incident gamma rays. This range became 0.1 ± 0.1% to 17 ± 2% for the worst case scenario of downlink speeds. The application of a feature visualization algorithm to GammaNet demonstrated decreased response to electronic noise and events exiting or entering the frame and increased response to parallel tracks that are close in proximity. GammaNet has been successfully implemented and shows promising results.

Richard L. Garnett↗