Search NASA⌕ Search

SEARCH · Search NASA

Results for “INHALATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Toxicity of thermal degradation products of spacecraft materials

Three polymeric materials were evaluated for relative toxicity of their pyrolysis products to rats by inhalation: Y-7683 (LS 200), Y-7684 (Vonar 3 on Fiberglass), and Y-7685 (Vonar 3 on N W Polyester). Criteria employed for assessing relative toxicity were (1) lethality from in-chamber pyrolysis, (2) lethality from an outside-of-chamber pyrolysis MSTL Procedure, and (3) disruption of trained rats' shock-avoidance performance during sub-lethal exposures to in-chamber pyrolysis of the materials.

Lawrence, W. H.↗

Evaluation of aerosolized medications during parabolic flight maneuvers

The goal was to visually evaluate the effect gravity has on delivery of medications by the use of various aerosol devices. During parabolic flight the same four aerosols were retested as performed in studio ground tests. It appears that the Cetacaine spray and the Ventolin inhaler function without failure during all test. The pump spray (Nostril) appeared to function normally when the container was full, however it appeared to begin to fail to deliver a full mist with larger droplet size when the container was nearly empty. The simple hand spray bottle appeared to work when the container was full and performed progressively worse as the container was emptied. During Apollo flights, it was reported that standard spray bottles did not work well, however, they did not indicate why. It appears that we would also conclude that standard spray bottles do not function as well in zero gravity by failing to produce a normal mist spray. The standard spray bottle allowed the fluid to come out in a narrow fluid stream when held with the nozzle either level or slightly tilted upward.

Lloyd, Charles W.↗

Human exposure limits to hypergolic fuels

Over the past four decades, many studies have been conducted on the toxicities of the rocket propellants hydrazine (HZ) and monomethylhydrazine (MH). Numerous technical challenges have made it difficult to unambiguously interpret the results of these studies, and there is considerable divergence between results obtained by different investigators on the inhalation concentrations (MAC's) for each toxic effect inducible by exposure to hypergolic fuels in spacecraft atmospheres, NASA undertook a critical review of published and unpublished investigations on the toxicities of these compounds. The current state of the art practices for similar studies. While many questions remain unanswered, MAC's were determined using the best available data for a variety of toxic endpoints for potential continuous exposure durations ranging from 1 hour to 180 days. Spacecraft MAC's (SMAC's) were set for each compound based on the most sensitive toxic endpoint at each exposure duration.

Garcia, H. D.↗

Development of lower body negative pressure as a countermeasure for orthostatic intolerance

Exposure to prolonged (1-4 hr) lower body negative pressure (LBNP) is a countermeasure against postflight orthostatic intolerance which is used in the Soviet space program and planned for use in the American space program. LBNP in combination with fluid-loading is believed to act by promoting a transient positive fluid balance resulting in an increase in vascular, as well as extravascular fluid. Inflight LBNP also may provide beneficial orthostatic effects by restoring baroreceptor reflex functions and/or lower body venous compliance. Current research efforts at the Johnson Space Center are directed toward increasing the effectiveness and efficiency of the LBNP and saline countermeasure. A promising avenue may involve combining pharmacologic agents, such as inhaled anti-diuretic hormone, or mineralocorticoids, with mechanical stimuli such as LBNP.

Fortney, Suzanne M.↗

Rett syndrome - Stimulation of endogenous biogenic amines

Transient hypercapnic hyperoxemia was induced in two Rett syndrome children by the administration of a gaseous mixture of 80 percent O2 and 20 percent CO2. Time course studies of neurotransmitters and their metabolites showed an immediate and marked increase in central biogenic amine turnover following inhalation of the gas mixture. The increased turnover of biogenic amines was associated with improved clinical changes. This suggests a coupled relationship and provides further support for an etiological role of neurotransmitter dysfunction in Rett syndrome. In a complementary study, elevation of pulmonary CO2 by application of a simple rebreathing device resulted in improvement of abnormal blood gases and elimination of the Cheyne-Stokes-like respiratory pattern of the Rett syndrome. Near normalization of the EEG occurred when a normal respiratory pattern was imposed by means of a respirator. Taken together, these results lead to the preliminary conclusion that cerebral hypoxemia secondary to abnormal respiratory function may contribute to diminished production of biogenic amines in Rett syndrome.

Pelligra, R.↗

Tests of artificial flight at high altitudes

If we wish to form an accurate idea of the extraordinary progress achieved in aeronautics, a comparison must be made of the latest altitude records and the figures regarded as highest attainable limit some ten years ago. It is desirable, for two reasons, that we should be able to define the limit of the altitudes that can be reached without artificial aid. First, to know to what extent the human body can endure the inhalation of rarified air. Second, the mental capacity of the aviator must be tested at high altitudes and the limit known below which he is able to make reliable observations without being artificially supplied with oxygen. A pneumatic chamber was used for the most accurate observations.

Gradenwitz, Arthur↗

Respiratory Protection Program medical clearance for respirator use

Background on occupational exposure to various inhalents is discussed including on-site hazard control measures, procedures, physiological effects, and interpretation of results for the medical clearance of employee for use of personal respiratory protection devices. The purpose of the Respiratory Protection Program at LeRC is outlined, and the specifics of the Medical Surveillance Program for Respiratory Protection at LeRC are discussed.

Source record↗

Gravity, the third dimension of life support in space

The ascent of the human into high altitudes required a 2-D life support system that supplied: oxygen, and heat. At lower altitudes, increased oxygen concentration in the inhaled gases was useful, but at higher altitudes for longer durations, this 'clever' life support approach was no longer adequate--physiologic requirements had to provide a natural pressure-based environment. In space, the life support system requires a third dimension, gravity. Although substituting for gravity has been successful on a limited number of physiologic functions for short-duration stays in space, long durations will require the effects of the real thing for critical physiologic functions. It has been known for over a hundred years that the forces of acceleration (G) and gravity are equivalent. Therefore, gravitational stimulation in space can be achieved with centrifugation. However, for this stimulation to be effective, the dosage of G required to maintain normal physiologic function must be determined. An approximation of this dosage of G for the human can be determined with 3-day bed-rest studies including periodic centrifuge exposure. Recent research on this topic is reviewed.

Burton, Russell R.↗

Development of an in-line filter to prevent intrusion of NO2 toxic vapors into A/C systems

The hypergolic propellant nitrogen tetroxide (N2O4 or NTO) is routinely used in spacecraft launched at Kennedy Space Center (KSC) and Cape Canaveral Air Station (CCAS). In the case of a catastrophic failure of the spacecraft, there would be a release of the unspent propellant in the form of a toxic cloud. Inhalation of this material at downwind concentrations which may be as high as 20 parts per million (ppm) for 30 minutes in duration, may produce irritation to the eyes, nose and respiratory tract. Studies at both KSC and CCAS have shown that the indoor concentrations of N2O4 during a toxic release may range from 1 to 15 ppm and depend on the air change rate (ACR) for a particular building and whether or not the air conditioning (A/C) system has been shut down or left in an operating mode. This project was initiated in order to assess how current A/C systems could be easily modified to prevent personnel from being exposed to toxic vapors. A sample system has been constructed to test the ability of several types of filter material to capture the N2O4 vapors prior to their infiltration into the A/C system. Test results will be presented which compare the efficiencies of standard A/C filters, water wash systems, and chemically impregnated filter material in taking toxic vapors out of the incoming air stream.

Meneghelli, Barry↗

A Summary of Ambient Air at John F. Kennedy Space Center with a Comparison to Data from the Florida Statewide Monitoring Network (1983-1992)

The EPA criteria air pollutants were monitored at Kennedy Space Center (KSC) since 1983 to comply the prevention of significant deterioration requirements under the Clean Air Act amendments passed by Congress in 1977 and 1990. Monitoring results show that monthly maximum 24-hour total suspended particulates decreased from 144.6 micograms/cu m in 1988 to 73.0 micrograms/cu m in 1991 and increased to 149.3 micrograms/cu m in 1992. Inhalable particulates increased from 56.1 gg/M3 in 1983 to 131.4 micrograms/cu m in 1988, and then decreased to 38.5 micrograms/cu m in 1992. Sulfur dioxide monthly maximum 24-hour average concentrations decreased each year from 135.2 micrograms/cu m in 1983 to 33.8 micrograms/cu m in 1992. Nitrogen dioxide concentrations increased from 5.1 micrograms/cu m in 1983 to 5.9 micrograms/cu m in 1988, then decreased to 4.5 micrograms/cu m in 1992. Carbon monoxide annual average concentrations decreased from 6.2 micrograms/cu m in 1983 to 1.1 micrograms/cu m in 1988, and increased to 1.2 micrograms/cu m in 1992. Ozone maximum 1-hour concentrations increased from 98 parts per billion (ppb) in 1983 to 134 ppb in 1989, and then decreased to 80 ppb in 1992. Total annual rainfall ranged from 37.47 inches to 57.47 inches and shows a 6.6 percent increase over this same ten year period.

Drese, John H.↗

COSMIC: Carbon Monoxide and Soot in Microgravity Inverse Combustion

Almost seventy percent of deaths in accidental fires are caused by inhalation of toxins such as carbon monoxide (CO) and smoke (soot) that form during underventilated burning. The COSMIC project examines the formation mechanisms of CO and soot during underventilated combustion, achieved presently using laminar, inverse diffusion flames (IDFs) formed between an air jet and surrounding fuel. A major hypothesis of the project is that the IDF mimics underventilated combustion because carbon-containing species that form on the fuel side of the flame (such as CO and soot) can escape without passing through an oxidizing flame tip. An IDF literature review was presented at the last microgravity workshop, and a few additional IDF papers have appeared since that meeting. The COSMIC project is entering the third year of its four-year funding cycle. The first two years have been devoted to designing and constructing a rig for use in the NASA 2.2-second drop tower. A few computations and laboratory experiments have been performed. The goals of this paper are to discuss the use of numerical simulation during burner design, to present computational and experimental results that support the hypothesis that IDFs are similar to underventilated flames, and to delineate future plans.

Blevins, L. G.↗

Particle Sizer

Microspheres are tiny plastic beads that represent the first commercial products manufactured in orbit. An example of how they are used is a new aerodynamic particle sizer designated APS 33B produced by TSI Incorporated. TSI purchased the microspheres from the National Bureau of Standards which certified their exact size and the company uses them in calibration of the APS 33B* instrument, latest in a line of TSI systems for generating counting and weighing minute particles of submicron size. Instruments are used for evaluating air pollution control devices, quantifying environments, meteorological research, testing filters, inhalation, toxicology and other areas where generation or analysis of small airborne particles is required. * The APS 33B is no longer being manufactured. An improved version, APS 3320, is now being manufactured. 2/28/97

Source record↗

Lung Diagnosis

NASA research in aircraft sound production provided a theoretical basis for a mode of the production of human respiratory sounds. Respiratory changes that occur after inhaling cigarette smoke may be recorded and analyzed. The research team includes representatives from the Medical College of Virginia, RTI, Bruel and Kjaer Instruments. A commercial market as a diagnostic tool is anticipated.

Source record↗

Space Technology for the Fire Department

A National Bureau of Standards/NASA project directed by Johnson resulted in a lightweight breathing system including face mask, frame, harness and air bottle marketed by Scott Aviation. Aluminum composite material was used; frame and harness were easier to put on and take off. Today every major manufacturer of breathing apparatus incorporates NASA technology in some form, and inhalation injuries have been reduced.

Source record↗

Atmosphere Analyzer

California Measurements, Inc.'s model PC-2 Aerosol Particle Analyzer is produced in both airborne and ground-use versions. Originating from NASA technology, it is a quick and accurate method of detecting minute amounts of mass loadings on a quartz crystal -- offers utility as highly sensitive detector of fine particles suspended in air. When combined with suitable air delivery system, it provides immediate information on the size distribution and mass concentrations of aerosols. William Chiang, obtained a NASA license for multiple crystal oscillator technology, and initially developed a particle analyzer for NASA use with Langley Research Center assistance. Later his company produced the modified PC-2 for commercial applications Brunswick Corporation uses the device for atmospheric research and in studies of smoke particles in Fires. PC-2 is used by pharmaceutical and chemical companies in research on inhalation toxicology and environmental health. Also useful in testing various filters for safety masks and nuclear installations.

Source record↗

Smoke Mask

Smoke inhalation injury from the noxious products of fire combustion accounts for as much as 80 percent of fire-related deaths in the United States. Many of these deaths are preventable. Smoke Mask, Inc. (SMI), of Myrtle Beach, South Carolina, is working to decrease these casualties with its line of life safety devices. The SMI personal escape hood and the Guardian Filtration System provide respiratory protection that enables people to escape from hazardous and unsafe conditions. The breathing filter technology utilized in the products is specifically designed to supply breathable air for 20 minutes. In emergencies, 20 minutes can mean the difference between life and death.

Source record↗

Development of Laser-Polarized Noble Gas Magnetic Resonance Imaging (MRI) Technology

We are developing technology for laser-polarized noble gas nuclear magnetic resonance (NMR), with the aim of enabling it as a novel biomedical imaging tool for ground-based and eventually space-based application. This emerging multidisciplinary technology enables high-resolution gas-space magnetic resonance imaging (MRI)-e.g., of lung ventilation, perfusion, and gas-exchange. In addition, laser-polarized noble gases (3He and 1BXe) do not require a large magnetic field for sensitive NMR detection, opening the door to practical MRI with novel, open-access magnet designs at very low magnetic fields (and hence in confined spaces). We are pursuing two specific aims in this technology development program. The first aim is to develop an open-access, low-field (less than 0.01 T) instrument for MRI studies of human gas inhalation as a function of subject orientation, and the second aim is to develop functional imaging of the lung using laser-polarized He-3 and Xe-129.

Walsworth, Ronald L.↗

Microgravity Superagglomerates Produced By Silane And Acetylene

The size of the agglomerates produced in the upper portion of a flame is important for a variety of applications. Soot particle size and density effect the amount of radiative heat transfer from a fire to its surroundings. Particle size determines the lifetime of smoke in a building or in the atmosphere, and exposure hazard for smoke inhaled and deposited in the lungs. The visibility through a smoke layer and dectectability of the smoke are also greatly affected by agglomerate size. Currently there is limited understanding of soot growth with an overall dimension of 10 m and larger. In the case of polystyrene, smoke agglomerates in excess of 1 mm have been observed raining out from large fires. Unlike hydrocarbon fuels, silane has the advantage that silica particles are the major combustion product resulting in a particle volume fraction a factor of ten greater than that for a carbonaceous smoke. There are two very desirable properties of silica aero-gels that are important for both space and earth based applications. The first important property is its inertness to most oxidizing and reducing atmospheres. Therefore, silica aero-gels make excellent fire ablatives and can be used in very demanding applications. The second important property is that silica aero-gels are expected to have very high porosity (greater than 0.999), making them lightweight and ideal for aerospace applications. The added benefit of the high porosity is that they can be used as extremely efficient filters for many earth based applications as well. Evidence of the formation of superagglomerates in a laminar acetylene/air diffusion flame was found by Sorensen et al. [1]. An interconnecting web of super-agglomerates was observed to span the width of the soot plume in the region just above the flame tip and described as a gel state. It was observed that this gel state immediately breaks up into agglomerates as larges as 100 m due to buoyancy induced turbulence. Large soot agglomerates were observed in microgravity butane jet diffusion flames by Ito et al.[2]. Several other works to date have studied the effect of flame structure on soot volume fraction and agglomeration size in a microgravity environment.[3-4]. In microgravity the absence of buoyant convective flows increases the residence time in the flame and causes a broadening of the high temperature region in the flame. Both of these factors play a significant role in gas phase radiation and soot formation

Gokoglu, Suleyman↗