Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSTRUMENT ORIENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Spatially Resolved, In Situ Carbon Isotope Analysis of Archean Organic Matter

Spatiotemporal variability in the carbon isotope composition of sedimentary organic matter (OM) preserves information about the evolution of the biosphere and of the exogenic carbon cycle as a whole. Primary compositions, and imprints of the post-depositional processes that obscure them, exist at the scale of individual sedimentary grains (mm to micron). Secondary ion mass spectrometry (SIMS) (1) enables analysis at these scales and in petrographic context, (2) permits morphological and compositional characterization of the analyte and associated minerals prior to isotopic analysis, and (3) reveals patterns of variability homogenized by bulk techniques. Here we present new methods for in situ organic carbon isotope analysis with sub-permil precision and spatial resolution to 1 micron using SIMS, as well as new data acquired from a suite of Archean rocks. Three analytical protocols were developed for the CAMECA ims1280 at WiscSIMS to analyze domains of varying size and carbon concentration. Average reproducibility (at 2SD) using a 6 micron spot size with two Faraday cup detectors was 0.4 %, and 0.8 % for analyses using 1 micron and 3 micron spot sizes with a Faraday cup (for C-12) and an electron multiplier (for C-13). Eight coals, two ambers, a shungite, and a graphite were evaluated for micron-scale isotopic heterogeneity, and LCNN anthracite (delta C-13 = -23.56 +/- 0.1 %, 2SD) was chosen as the working standard. Correlation between instrumental bias and H/C was observed and calibrated for each analytical session using organic materials with H/C between 0.1 and 1.5 (atomic), allowing a correction based upon a C-13H/C-13 measurement included in every analysis. Matrix effects of variable C/SiO2 were evaluated by measuring mm to sub-micron graphite domains in quartzite from Bogala mine, Sri Lanka. Apparent instrumental bias and C-12 count rate are correlated in this case, but this may be related to a crystal orientation effect in graphite. Analyses of amorphous Archean OM suggest that instrumental bias is consistent for 12C count rates as low as 10% relative to anthracite. Samples from the ABDP-9 (n=3; Mount McRae Shale, approximately 2.5 Ga), RHDH2a (n=2; Carrawine Dolomite and Jeerinah Fm, approximately 2.6 Ga), WRL1 (n=3; Wittenoom Fm, Marra Mamba Iron Formation, and Jeerinah Fm, approximately 2.6 Ga), and SV1 (n=1; Tumbiana Fm, approximately 2.7 Ga) drill cores, each previously analyzed for bulk organic carbon isotope composition, yielded 100 new, in situ data from Neoarchean sedimentary OM. In these samples, delta C-13 varies between -53.1 and -28.3 % and offsets between in situ and bulk compositions range from -8.3 to 18.8%. In some cases, isotopic composition and mode of occurrence (e.g. morphology and mineral associations) are statistically correlated, enabling the identification of distinct reservoirs of OM. Our results support previous evidence for gradients of oxidation with depth in Neoarchean environments driven by photosynthesis and methane metabolism. The relevance of these findings to questions of bio- and syngenicity as well as the alteration history of previously reported Archean OM will be discussed.

Williford, Kenneth H.↗

Multi-Angle Snowflake Camera Instrument Handbook

The Multi-Angle Snowflake Camera (MASC) takes 9- to 37-micron resolution stereographic photographs of free-falling hydrometers from three angles, while simultaneously measuring their fall speed. Information about hydrometeor size, shape orientation, and aspect ratio is derived from MASC photographs. The instrument consists of three commercial cameras separated by angles of 36º. Each camera field of view is aligned to have a common single focus point about 10 cm distant from the cameras. Two near-infrared emitter pairs are aligned with the camera’s field of view within a 10-angular ring and detect hydrometeor passage, with the lower emitters configured to trigger the MASC cameras. The sensitive IR motion sensors are designed to filter out slow variations in ambient light. Fall speed is derived from successive triggers along the fall path. The camera exposure times are extremely short, in the range of 1/25,000th of a second, enabling the MASC to capture snowflake sizes ranging from 30 micrometers to 3 cm.

47 OTHER INSTRUMENTATION↗

The Ring Current ENA Instrument on the NASA STORIE Mission

NASA has recently selected the Storm Time O+ Ring current Imaging Evolution (STORIE) mission to study the evolution of Earth’s ring current and the role of composition and dynamics during geomagnetic storms. STORIE addresses this inner magnetospheric science through the use of a Ring current Energetic Neutral Atom (RENA) instrument hosted on the International Space Station (ISS). This novel vantage point for ENA imaging has a number of scientific and implementation advantages. RENA is a high sensitivity remote sensing ENA imager and composition instrument with a field of view of 90 x 2 degrees, and an angular resolution of 2 x 2 degrees. The instrument aperture points zenith and its long dimension is oriented perpendicular to the ISS ram direction. As a result, RENA acts as a “push broom” imager building up a complete sky scan of the ring current in a single 90-minute ISS orbit. The instrument employs electrostatic optics along with a foil-MCP TOF x PHA x Delay-Line position measurement technique to resolve H and O energy spectra in the energy range 10-500 KeV for each look direction. Furthermore, it employs triple+ time and position coincidence to effectively reduce background noise from geocoronal and black sky UV as well as penetrating radiation. The abundant mass, power, and telemetry, resources of the ISS allow for large instrument aperture, very high sensitivity, complex data product and simplified operations, altogether contributing towards a high signal to noise (S/N) measurement.

Space Science↗

Program Instrumentation and Trace Analysis

Several attempts have been made recently to apply techniques such as model checking and theorem proving to the analysis of programs. This shall be seen as a current trend to analyze real software systems instead of just their designs. This includes our own effort to develop a model checker for Java, the Java PathFinder 1, one of the very first of its kind in 1998. However, model checking cannot handle very large programs without some kind of abstraction of the program. This paper describes a complementary scalable technique to handle such large programs. Our interest is turned on the observation part of the equation: How much information can be extracted about a program from observing a single execution trace? It is our intention to develop a technology that can be applied automatically and to large full-size applications, with minimal modification to the code. We present a tool, Java PathExplorer (JPaX), for exploring execution traces of Java programs. The tool prioritizes scalability for completeness, and is directed towards detecting errors in programs, not to prove correctness. One core element in JPaX is an instrumentation package that allows to instrument Java byte code files to log various events when executed. The instrumentation is driven by a user provided script that specifies what information to log. Examples of instructions that such a script can contain are: 'report name and arguments of all called methods defined in class C, together with a timestamp'; 'report all updates to all variables'; and 'report all acquisitions and releases of locks'. In more complex instructions one can specify that certain expressions should be evaluated and even that certain code should be executed under various conditions. The instrumentation package can hence be seen as implementing Aspect Oriented Programming for Java in the sense that one can add functionality to a Java program without explicitly changing the code of the original program, but one rather writes an aspect and compiles it into the original program using the instrumentation. Another core element of JPaX is an observation package that supports the analysis of the generated event stream. Two kinds of analysis are currently supported. In temporal analysis the execution trace is evaluated against formulae written in temporal logic. We have implemented a temporal logic evaluator on finite traces using the Maude rewriting system from SRI International, USA. Temporal logic is defined in Maude by giving its syntax as a signature and its semantics as rewrite equations. The resulting semantics is extremely efficient and can handle event streams of hundreds of millions events in few minutes. Furthermore, the implementation is very succinct. The second form of even stream analysis supported is error pattern analysis where an execution trace is analyzed using various error detection algorithms that can identify error-prone programming practices that may potentially lead to errors in some different executions. Two such algorithms focusing on concurrency errors have been implemented in JPaX, one for deadlocks and the other for data races. It is important to note, that a deadlock or data race potential does not need to occur in order for its potential to be detected with these algorithms. This is what makes them very scalable in practice. The data race algorithm implemented is the Eraser algorithm from Compaq, however adopted to Java. The tool is currently being applied to a code base for controlling a spacecraft by the developers of that software in order to evaluate its applicability.

Havelund, Klaus↗

A new white beam x-ray microdiffraction setup on the BM32 beamline at the European Synchrotron Radiation Facility

A white beam microdiffraction setup has been developed on the bending magnet source BM32 at the European Synchrotron Radiation Facility. The instrument allows routine submicrometer beam diffraction to perform orientation and strain mapping of polycrystalline samples. The setup features large source to optics distances allowing large demagnification ratios and small beam sizes. The optics of the beamline is used for beam conditioning upstream a secondary source, suppressing any possible interference of beam conditioning on beam size and position. The setup has been designed for an easy and efficient operation with position control tools embedded on the sample stage, a high magnification large aperture optical microscope, and fast readout detectors. Switching from the white beam mode to the monochromatic mode is made easy by an automatic procedure and allows the determination of both the deviatoric and hydrostatic strain tensors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using XML and Java for Astronomical Instrumentation Control

Traditionally, instrument command and control systems have been highly specialized, consisting mostly of custom code that is difficult to develop, maintain, and extend. Such solutions are initially very costly and are inflexible to subsequent engineering change requests, increasing software maintenance costs. Instrument description is too tightly coupled with details of implementation. NASA Goddard Space Flight Center is developing a general and highly extensible framework that applies to any kind of instrument that can be controlled by a computer. The software architecture combines the platform independent processing capabilities of Java with the power of the Extensible Markup Language (XML), a human readable and machine understandable way to describe structured data. A key aspect of the object-oriented architecture is software that is driven by an instrument description, written using the Instrument Markup Language (IML). ]ML is used to describe graphical user interfaces to control and monitor the instrument, command sets and command formats, data streams, and communication mechanisms. Although the current effort is targeted for the High-resolution Airborne Wideband Camera, a first-light instrument of the Stratospheric Observatory for Infrared Astronomy, the framework is designed to be generic and extensible so that it can be applied to any instrument.

Ames, Troy↗

The retinal funduscope demonstration project

A lightweight, relatively inexpensive electronic and photographic instrument has been re-developed for the detection, monitoring, and objective quantification of ocular/ systemic disease or physiological alterations of the retina, blood vessels, or other structures in the anterior and posterior chambers of the eye. The instrument can be operated with little training. It can function with a human or animal subject seated, recumbent, inverted, or in almost any other orientation; and in a hospital, laboratory, field, or other environment. The instrument produces video images that can be viewed directly and/or digitized for simultaneous or subsequent analysis. It can also be equipped to produce photographs and/or fitted with adaptors to produce stereoscopic or magnified images ot the skin, nose, ear, throat, or mouth to detect lesions or diseases.

Wilhelm, Jim↗

NASA Tech Briefs, September 2010

Topics covered include: Instrument for Measuring Thermal Conductivity of Materials at Low Temperatures; Multi-Axis Accelerometer Calibration System; Pupil Alignment Measuring Technique and Alignment Reference for Instruments or Optical Systems; Autonomous System for Monitoring the Integrity of Composite Fan Housings; A Safe, Self-Calibrating, Wireless System for Measuring Volume of Any Fuel at Non-Horizontal Orientation; Adaptation of the Camera Link Interface for Flight-Instrument Applications; High-Performance CCSDS Encapsulation Service Implementation in FPGA; High-Performance CCSDS AOS Protocol Implementation in FPGA; Advanced Flip Chips in Extreme Temperature Environments; Diffuse-Illumination Systems for Growing Plants; Microwave Plasma Hydrogen Recovery System; Producing Hydrogen by Plasma Pyrolysis of Methane; Self-Deployable Membrane Structures; Reactivation of a Tin-Oxide-Containing Catalys; Functionalization of Single-Wall Carbon Nanotubes by Photo-Oxidation; Miniature Piezoelectric Macro-Mass Balance; Acoustic Liner for Turbomachinery Applications; Metering Gas Strut for Separating Rocket Stages; Large-Flow-Area Flow-Selective Liquid/Gas Separator; Counterflowing Jet Subsystem Design; Water Tank with Capillary Air/Liquid Separation; True Shear Parallel Plate Viscometer; Focusing Diffraction Grating Element with Aberration Control; Universal Millimeter-Wave Radar Front End; Mode Selection for a Single-Frequency Fiber Laser; Qualification and Selection of Flight Diode Lasers for Space Applications; Plenoptic Imager for Automated Surface Navigation; Maglev Facility for Simulating Variable Gravity; Hybrid AlGaN-SiC Avalanche Photodiode for Deep-UV Photon Detection; High-Speed Operation of Interband Cascade Lasers; 3D GeoWall Analysis System for Shuttle External Tank Foreign Object Debris Events; Charge-Spot Model for Electrostatic Forces in Simulation of Fine Particulates; Hidden Statistics Approach to Quantum Simulations; Reconstituted Three-Dimensional Interactive Imaging; Determining Atmospheric-Density Profile of Titan; Digital Microfluidics Sample Analyzer; Radiation Protection Using Carbon Nanotube Derivatives; Process to Selectively Distinguish Viable from Non-Viable Bacterial Cells; and TEAMS Model Analyzer.

Source record↗

Terrestrial Gamma-Ray Flashes (TGFs) Above Thunderstorms

Intense of gamma rays have been observed by five different space-borne detectors. The TGFs have hard spectra, with photons extending to over 50 MeV. Most of these flashes last less than a millisecond. Relativistic electrons and positrons associated with TGFs are also seen by orbiting instruments In a special mode of operation, the Fermi-GBM detectors are now detecting an average of about one TGF every two hours. The Fermi spacecraft has been performing special orientations this year which has allowed the Fermi-LAT instrument also detect TGFs. The most likely origin of these high energy photons is bremsstrahlung radiation from electrons, produced by relativistic runaway electrons in intense electric fields within or above thunderstorm regions; the altitude of origin is uncertain. These TGFs may produce an appreciable radiation dose to passengers and crew in nearby aircraft. The observational aspects of TGFs will be the main focus of this talk; theoretical aspects remain speculative.

Fishman, Gerald J.↗

Test Facilities for SHERLOC Laser Development

The Scanning Habitable Environments with Raman and Luminescence for Organics and Chemicals (SHERLOC) instrument is a deep UV laser based spectrometer that is part of NASA’s Mars Perseverance rover. The laser is a pulsed 248.6 nm NeCu hollow cathode gas discharge laser. The design, development, and testing of lasers and laser power supplies (LPS) were performed by scientists and engineers at the Jet Propulsion Laboratory (JPL) and Photon Systems Inc. (PSI). While these lasers had been used previously in extreme terrestrial environments, before they had to be qualified for operation and functionality over the expected range of environmental situations (temperature cycling, vibration, mechanical shock, low pressure corona emission testing) over the course of mission life time. The SHERLOC laser/LPS testing facilities consisted of custom-tailored environmental test chambers with metrology/control electronics. A custom LabVIEW software package was developed to autonomously operate all test facilities using a multi-threaded, object-oriented programming architecture, tasked with interfacing with many instruments simultaneously for operation and data acquisition.

Houck, Andrew↗

On the applicability of integrated circuit technology to general aviation orientation estimation

The criteria of the significant value of the panel instruments used in general aviation were examined and kinematic equations were added for comparison. An instrument survey was performed to establish the present state of the art in linear and angular accelerometers, pressure transducers, and magnetometers. A very preliminary evaluation was done of the computers available for data evaluation and estimator mechanization. The mathematical model of a light twin aircraft employed in the evaluation was documented, the results of the sensor survey and the results of the design studies were presented.

Debra, D. B.↗

New Limit on Lorentz- and CPT-Violating Neutron Spin Interactions

We performed a search for neutron spin coupling to a Lorentz- and CPT-violating background field using a magnetometer with overlapping ensembles of K and {sup 3}He atoms. The comagnetometer is mounted on a rotary platform for frequent reversal of its orientation. We measure sidereal oscillations in the signal to search for anomalous spin coupling of extra-solar origin. We determine the equatorial components of the background field interacting with the neutron spin to be b-tilde{sub X}{sup n}=(0.1{+-}1.6)x10{sup -33} GeV and b-tilde{sub Y}{sup n}=(2.5{+-}1.6)x10{sup -33} GeV, improving on the previous limit by a factor of 30. This measurement represents the highest energy resolution of any spin anisotropy experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Structure, bonding, and magnetic response in two complex borides: Zr{sub 2}Fe{sub 1-{delta}}Ru{sub 5+{delta}}B2 and Zr{sub 2}Fe{sub 1-{delta}}(Ru{sub 1-x}Rh{sub x}){sub 5+{delta}}B2

Polycrystalline samples of two complex intermetallic borides Zr{sub 2}Fe{sub 1-{delta}}Ru{sub 5+{delta}}B2 and Zr{sub 2}Fe{sub 1-{delta}}(Ru{sub 1-x}Rh{sub x}){sub 5+{delta}}B2 ({delta}=ca. 0.10; x=0.20) were synthesized by high-temperature methods and characterized by single-crystal X-ray diffraction, energy dispersive spectroscopy, and magnetization measurements. Both structures are variants of Sc{sub 2}Fe(Ru{sub 1-x}Rh{sub x}){sub 5}B{sub 2} and crystallize in the space group P4/mbm (no. 127) with the Ti{sub 3}Co{sub 5}B{sub 2}-type structure. These structures contain single-atom, Fe-rich Fe/Ru or Fe/Ru/Rh chains along the c-axis with an interatomic metal-metal distance of 3.078(1) A, a feature which makes them viable for possible low-dimensional temperature-dependent magnetic behavior. Magnetization measurements indicated weak ferrimagnetic ordering with ordering temperatures ca. 230 K for both specimens. Tight-binding electronic structure calculations on a model 'Zr{sub 2}FeRu{sub 5}B{sub 2}' using LDA yielded a narrow peak at the Fermi level assigned to Fe-Fe antibonding interactions along the c-axis, a result that indicates an electronic instability toward ferromagnetic coupling along these chains. Spin-polarized calculations of various magnetic models were examined to identify possible magnetic ordering within and between the single-atom, Fe-rich chains. -- Graphical abstract: Zr{sub 2}FeRu{sub 5-x}Rh{sub x}B{sub 2} (x=0, 1) crystallizes with magnetic atoms forming chains which have been shown to order magnetically depending on the total valence electron count. Magnetic measurements and tight-binding electronic structure calculations are employed to investigate the ordering. Display Omitted

36 MATERIALS SCIENCE↗

Polarization Of The High-Energy And Of The Electron-Nucleus Bremsstrahlung In Electron-Atom Collisions

The linear polarization of bremsstrahlung radiation emitted in collisions of spin-polarized and unpolarized electrons with carbon and gold targets has been measured for an incident kinetic energy of 100 keV. We present preliminary results for the degree of linear polarization for incident unpolarized electrons as a function of bremsstrahlung photon energy.

74 ATOMIC AND MOLECULAR PHYSICS↗

Limits on New Long Range Nuclear Spin-Dependent Forces Set with a K-{sup 3}He Comagnetometer

A magnetometer using spin-polarized K and {sup 3}He atoms occupying the same volume is used to search for anomalous nuclear spin-dependent forces generated by a separate {sup 3}He spin source. We measure changes in the {sup 3}He spin precession frequency with a resolution of 18 pHz and constrain anomalous spin forces between neutrons to be less than 2x10{sup -8} of their magnetic or less than 2x10{sup -3} of their gravitational interactions on a length scale of 50 cm. We present new limits on neutron coupling to light pseudoscalar and vector particles, including torsion, and constraints on recently proposed models involving unparticles and spontaneous breaking of Lorentz symmetry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Replacement Cold Neutron Guide System for HFIR (Conceptual Design Report)

The design of a replacement cold neutron guide system for the High Flux Isotope Reactor (HFIR) is presented. The proposed six-channel design uses the latest technologies and is optimally designed to account for operational and site constraints. These include the design of the cold source and the beam tube, the size and shape of the penetrations in the reactor confinement boundary, and the shape and orientation of the guide hall. The existing user instruments are a macromolecular diffractometer (IMAGINE), an IMAGING station, two small-angle neutron scattering (SANS) instruments (Bio-SANS and GP-SANS), and a cold triple-axis spectrometer (C-TAX). These instruments will all be reinstalled at end-of-guide positions with improved performance, and a position for a new high-performance neutron spin echo instrument will be created. The proposed guide design requires an extension to the guide hall toward the south. The calculated flux gain for a typical experiment is between a factor of 1.3 and 3 for all instruments, with the exception of the C-TAX instrument, which stands to gain a factor of >30 in flux at the sample. The new guide system will also offer additional performance gains, such as an increase in Q-range on Bio-SANS. The stated performance gains do not take into account any potential performance gains resulting from renewal and realignment of the guide system. The design of the guide system in the common sections up to about 25 m from the source is considered to be complete and ready for engineering design, while the designs of the instrument-specific guides are in some cases still a work in progress. The present report describes the current status of those designs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design of a multi-detector spectrometer for the infrared

A modified Ebert-Fastie spectrometer has been developed for atmospheric temperature sounding applications. The device is described with reference to its resolution, grating, focal-length mirror, mirror, equivalent f-number, and projected area of grating. The images of the entrance slit appear tilted backwards away from the concave mirror. Astigmatism and spherical aberration are reduced by asperizing the mirror. The resolution and f-number of the instrument are limited by the sagittal coma. The orientation and size of the exit slit are functions of wavelength.

Koch, D. G.↗

The Malcolm horizon: History and future

The development of the Malcolm Horizon, a peripheral vision horizon used in flight simulation, is discussed. A history of the horizon display is presented as well as a brief overview of vision physiology, and the role balance plays is spatial orientation. Avenues of continued research in subconscious cockpit instrumentation are examined.

Malcolm, R.↗