Search NASA⌕ Search

SEARCH · Search NASA

Results for “INSULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Stress-Dependent Voltage Offsets From Polymer Insulators Used in Rock Mechanics and Material Testing

Dielectric insulators are used in a variety of laboratory settings when performing experiments in rock mechanics, petrology, and electromagnetic studies of rocks in the fields of geophysics,material science, and civil engineering. These components may be used to electrically isolate geological samples from the experimental equipment, to perform a mechanical compliance function between brittle samples and the loading equipment, to match ultrasonic transducers, or perform other functions. In manyexperimental configurations the insulators bear the full brunt of force applied to the sample but do not need to withstand high voltages, therefore the insulators are often thin sheets of mechanically tough polymers. From an instrument perspective, transduction from various types of mechanical perturbation has beenqualitatively compared for a number of polymers [1, 2] and these error sources are readily apparent duringhigh-impedance measurements if not mitigated. However even when following best practices, a force dependent voltage signal still remains and its behavior is explored in this presentation. In this experimenttwo thin sheets (0.25 mm) of high-density polyethylene (HDPE) were set up in a stack, held alternatelybetween three aluminum bars; this stack was placed on the platen of a 60T capacity hydraulic testingmachine. The surface area, A, over which the force is applied to the PE sheets in this sandwich is roughly 40 square cm, each sheet forming a parallel-plate capacitor having roughly 320 pF [3], assuming therelative dielectric permittivity of PE is approximately 2.3. The outer two aluminum bars were connected to the LO input ofthe electrometer and the central aluminum bar was connected to the HI input of a Keithley model 617 electrometer. Once the stack is mechanically well-seated with no air gaps, the voltage offset is observed tobe a linear function of the baseline voltage for a given change in applied force. For a periodically appliedforce of 66.7 kN the voltage offsets were measured as a function of initial voltage, and these data were fitwith a linear function that was constrained to pass through the origin. The best fit solution had a correlation coefficient of R=0.85 and a slope of approximately -0.0228 volts/volt. The voltage offset when normalizedis demonstrated to be constant -2.28% for both positive and negative polarities over nearly 3 orders ofbaseline voltage magnitude. From this, the voltage-force coefficient is derived to be -0.34 ppm/N. Thiscorrelates well to a first-order parallel plate capacitor model that assumes constant area, and smalldeformation such that the polymer may be mechanically modeled by a spring that obeys Hookes law. Thissimple model predicts that the coefficient of proportionality is a function of Youngs modulus E= 0.8 GPaand surface area of the insulator, theoretically -1EA= -0.31 ppm/N. The outcome of this work is animproved insulator made from ultra-high molecular weight (UHMW) polyethylene and other approachestoward the minimization of and compensation for these experimental artifacts.

Electromagnetic Studies of Rocks↗

Thin Aerogel as a Spacer in Multilayer Insulation

Cryogenic fluid management is a critical technical area that is needed for future space exploration. A key challenge is the storability of liquid hydrogen (LH2), liquid methane (LCH4), and liquid oxygen (LOX) propellants for long-duration missions. The storage tanks must be well-insulated to prevent over-pressurization and venting, which can lead to unacceptable propellant losses for long-duration missions to Mars and beyond. Aspen Aerogels had validated the key process step to enable the fabrication of thin, low-density aerogel materials. The multilayer aerogel insulation (MLAI) system prototypes were prepared using sheets of aerogel materials with superior thermal performance exceeding current state-of-the-art insulation for space applications. The exceptional properties of this system include a new breakthrough in high-vacuum cryogenic thermal insulation, providing a durable material with excellent thermal performance at a reduced cost when compared to longstanding state-of-the-art multilayer insulation systems. During the Phase II project, further refinement and qualification/system-level testing of the MLAI system will be performed for use in cryogenic storage applications. Aspen has been in discussions with United Launch Alliance, LLC; NASA's Kennedy Space Center; and Yetispace, Inc., to test the MLAI system on real-world tanks such as Vibro-Acoustic Test Article (VATA) or the Cryogenic Orbital Testbed (CRYOTE).

Moroz, Nancy↗

Thin Aerogel as a Spacer in Multilayer Insulation

Cryogenic fluid management is a critical technical area that is needed for future space exploration. A key challenge is the storability of liquid hydrogen (LH2), liquid methane (LCH4), and liquid oxygen (LOX) propellants for long-duration missions. The storage tanks must be well-insulated to prevent over-pressurization and venting, which can lead to unacceptable propellant losses for long-duration missions to Mars and beyond. Aspen Aerogels had validated the key process step to enable the fabrication of thin, low-density aerogel materials. The multilayer aerogel insulation (MLAI) system prototypes were prepared using sheets of aerogel materials with superior thermal performance exceeding current state-of-the-art insulation for space applications. The exceptional properties of this system include a new breakthrough in high-vacuum cryogenic thermal insulation, providing a durable material with excellent thermal performance at a reduced cost when compared to longstanding state-of-the-art multilayer insulation systems. During the Phase II project, further refinement and qualification/system-level testing of the MLAI system will be performed for use in cryogenic storage applications. Aspen has been in discussions with United Launch Alliance, LLC; NASA's Kennedy Space Center; and Yetispace, Inc., to test the MLAI system on rea-lworld tanks such as Vibro-Acoustic Test Article (VATA) or the Cryogenic Orbital Testbed (CRYOTE).

Moroz, Nancy↗

Vacuum Pump-Down of the Annular Insulation Space for Large Field-Erected Liquid Hydrogen Storage Tanks

Insulation systems are critical to liquid hydrogen storage tank performance. Tanks in the capacity range of 100 to 1,000 m 3 are typically shop built and designed with high-vacuum (HV) multi-layer insulation (MLI), whereas storage vessels larger than 1,000 m 3 are typically field-erected and supplied with bulk fill insulation working at moderate vacuum (MV) levels (1-100 millitorr). For large, field-erected vessels, two types of bulk fill insulation typically used: perlite and hollow glass microspheres (glass bubbles). Selection of either material is driven by a tradeoff between CAPEX and OPEX, such as the material and construction cost versus operating thermal performance and maintenance. In either case, the vacuum level needed to achieve optimum performance is likely to drive the field testing and commissioning portion of the construction schedule. A primary goal of this paper is to present practical experience and data for warm vacuum pressure (WVP) and cold vacuum pressure (CVP) levels. Recommended WVP levels needed prior to cooldown consider both perlite powder and glass bubbles. Pumping time expected to achieve target vacuum levels, considering a variety of factors, is also discussed. Recommendations for a standard practice in vacuum-insulated tank commissioning are based on historical NASA data, and those collected during recent projects.

A M Swanger↗

Demonstration of Hybrid Multilayer Insulation for Fixed Thickness Applications

Once on orbit, high performing insulation systems for cryogenic systems need just as good radiation (optical) properties as conduction properties. This requires the use of radiation shields with low conductivity spacers in between. By varying the height and cross-sectional area of the spacers between the radiation shields, the relative radiation and conduction heat transfers can be manipulated. However, in most systems, there is a fixed thickness or volume allocated to the insulation. In order to understand how various combinations of different multilayer insulation (MLI) systems work together and further validate thermal models of such a hybrid MLI set up, test data is needed. The MLI systems include combinations of Load Bearing MLI (LB-MLI) and traditional MLI. To further simulate the space launch vehicle case wherein both ambient pressure and vacuum environments are addressed, different cold-side thermal insulation substrates were included for select tests.

Cryogenic Fluid Management↗

Absorption Voltages and Insulation Resistance in Ceramic Capacitors with Cracks

Time dependence of absorption voltages (Vabs) in different types of low-voltage X5R and X7R ceramic capacitors was monitored for a maximum duration of hundred hours after polarization. To evaluate the effect of mechanical defects on Vabs, cracks in the dielectric were introduced either mechanically or by thermal shock. The maximum absorption voltage, time to roll-off, and the rate of voltage decrease are shown to depend on the crack-related leakage currents and insulation resistance in the parts. A simple model that is based on the Dow equivalent circuit for capacitors with absorption has been developed to assess the insulation resistance of capacitors. Standard measurements of the insulation resistance, contrary to the measurements based on Vabs, are not sensitive to the presence of mechanical defects and fail to reveal capacitors with cracks. Index Terms: Ceramic capacitor, insulation resistance, dielectric absorption, cracking.

cracking↗

Advanced Cryogenic Insulation Systems

New materials in recent decades have enabled advances in thermal insulation systems for storage and transfer of cryogens. To preserve the cold and achieve efficient cryogenic systems, a combination of materials, testing, and engineering is required. The total heat leak into any cryogenic assembly is comprised of three main parts: 1) heat leak through the insulation, 2) heat leak through the support structures, and 3) heat leak attributed to piping penetrations and feedthroughs (and their negative effects on the insulation). This "cold triangle" approach provides a basis for evaluating performance benefits of new materials and analyzing the cost effectiveness in overall system design. Provided are thermophysical data for aerogels, aerogel composites, novel multilayered composites, and glass bubbles for standard test conditions of 293 K and 78 K under conditions from high vacuum to ambient pressure. Examples of cryogenic storage tanks show the relative importance of both insulation and structural materials for achieving designs of highest energy efficiency.

Multilayer Insulation↗

Summary of Testing Results for the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER)

Testing was completed on the Structural Heat Intercept, Insulation, and Vibration Evaluation Rig (SHIIVER) between August 2019 and January 2020. SHIIVER was designed to be a test bed for the scaling of cryogenic fluid management technologies as applied to large upper stages and long duration in-space stages. The baseline SHIIVER design consists of uninsulated structural skirts attached to a propellant tank insulated with polyurethane Spray-On Foam Insulation (SOFI). The initial testing of the SHIIVER hardware was with liquid hydrogen and sought to demonstrate the use of boil-off vapor to intercept heat on a structural skirt, multilayer insulation (MLI) on the tank domes, and the radio frequency mass gauge (RFMG). Testing was completed in four stages: a baseline thermal vacuum test prior to installation of the MLI on the tank domes, a thermal vacuum test after the MLI installation, a reverberant acoustic test, and a subsequent thermal vacuum test to verify that no damage occurred during the reverberant acoustic testing. Each thermal vacuum test with chamber wall at ambient temperature and vacuum level in the 10-6 torr range was conducted continuously between approximately 90% full and 25% full. Test results showed that the vapor cooling reduced the heat load to the tank by approximately 10%, but the boil-off by less than 3% at 50% full, with and without MLI installed on the domes. The MLI installed on the domes reduced the heat load to the tank by approximately 40% at all fill levels, but the boil-off by approximately 25% at 90% full and 45% below 65% full. The RFMG performed well over all fill ranges, and several RF tank modes were used to gauge the mass of fluid in the tank. SHIIVER was then exposed to an acoustic environment of 147 dB OASPL (overall sound pressure level) in a reverberant chamber. The acoustic environment envelopes the upper stage internal acoustic level of several different modern launch vehicles. No structural or thermal performance changes were observed after exposure to the acoustic environment. Final thermal vacuum testing after the acoustic testing showed no degradation to the MLI due to the acoustic environment as measured via system heat loads

SHIIVER↗

Modernization of Insulative Reusable Thermal Protection Systems (IRTPS)

Insulative thermal protection systems, such as Flexible Reusable Surface Insulation blankets and High Temperature Reusable Surface Insulation tiles, were developed for the Shuttle Orbiter to enable reuse of the vehicle for low-earth orbit missions. Since reusability is essential to many new industry launch and space vehicles, Shuttle-derived thermal protection materials (TPMs) are being sought for their flight proven performance. Alumina Enhanced Thermal Barrier (AETB) is the state-of-the-art tile material that was developed in the 90’s. AETB along with associated coatings, reaction cured glass (RCG) and Toughened Unipiece Fibrous Insulation (TUFI), are currently made by NASA using heritage raw materials derived from lifetime purchases. Finding viable replacements for raw materials that have changed in nature or are obsolete is important for continuation of these TPMs. In some cases, the use of modern raw materials has been shown to yield tile with reduced performance, most notably in mechanical properties. ​ In this work, the production of AETB will be discussed to better understand the process-structure-property relationships and for allowing use of these modern alternatives. A small-scale tile casting system was developed for rapid and efficient exploration of the manufacturing variables such raw material selection and pre-processing, casting process parameters, and billet firing protocols. An optical transmission defect characterization technique was implemented to correlate process variables to structure. Comparisons between TUFI/RCG coated AETB derived from heritage and modern raw materials will be shown including AHF arc jet test results completed under a collaboration with Stratolaunch.

thermal protection materials↗

Alternator insulation evaluation tests

Tests were conducted to predict the remaining electrical insulation life of a 60 KW homopolar inductor alternator following completion of NASA turbo-alternator endurance tests for SNAP-8 space electrical power systems application. The insulation quality was established for two alternators following completion of these tests. A step-temperature aging test procedure was developed for insulation life prediction and applied to one of the two alternators. Armature winding insulation life of over 80,000 hours for an average winding temperature of 248 degrees C was predicted using the developed procedure.

Penn, W. B.↗

Status of reusable surface insulation thermal protection system technology programs

The development of three low-density rigidized insulation materials for the shuttle TPS application is reported. These materials consist of one high purity silica system and two systems based on mullite, an aluminum silicate. Both systems consist of fibers joined together with appropriate binders to obtain a rigidized insulation composite. Both material systems require the application of a glassy coating to provide a wear resistant, high emittance surface and to prevent the absorption of water by the fiber matrix. The technology program has addressed the development of water impervious coatings, methods of assembling the materials in design concepts while minimizing the thermal stress in the insulation, achieving compatibility between the RSI material and the structural system, and test evaluations to demonstrate the feasibility of the surface insulation concept.

Greenshields, D. H.↗

Development of advanced materials composites for use as insulations for LH2 tanks

A study of internal insulation materials and fabrication processes for space shuttle LH2 tanks is reported. Emphasis was placed on an insulation system capable of reentry and multiple reuse in the Shuttle environment. Results are given on the optimization and manufacturing process scale-up of a 3D fiberreinforced foam insulation, BX-251-3D, derived from the Saturn S-4B internal insulation. It is shown that BX-251-3D can be satisfactorily installed in large-scale tanks under conditions that will permit a significant cost saving over the existing S-4B technology.

Lemons, C. R.↗

Development of techniques and instrumentation for the nondestructive evaluation of multi-layer insulation

The development of techniques and instrumentation suitable for the nondestructive evaluation of purged multilayer insulation prior to and after a shuttle orbiter flight is discussed. These techniques are desirable because of the possibility that corrosion, compression, or tearing of the insulation will degrade the performance of the insulation during subsequent flights. A second objective was the application of the developed technology to the evaluation of other insulation types. Three nondestructive evaluation techniques, electromagnetic, thermal, and acoustic were selected for evaluation. The results of evaluation of each technique are described.

Source record↗

Development of advanced material composites for use as internal insulation for LH2 tanks (gas layer concept)

A program is described that was conducted to develop an internal insulation system for potential application to the liquid hydrogen tanks of a reusable booster, where the tanks would be subjected to repeated high temperatures. The design of the internal insulation is based on a unique gas layer concept, in which capillary or surface tension effects are used to maintain a stable gas layer, within a cellular core structure, between the tank wall and the contained liquid hydrogen. Specific objectives were to select materials for insulation systems that would be compatible with wall temperatures of 350 F and 650 F during reentry into the earth's atmosphere, and to fabricate and test insulation systems under conditions simulating the operating environment. A materials test program was conducted to evaluate the properties of candidate materials at elevated temperatures and at the temperature of liquid hydrogen, and to determine the compatibility of the materials with a hydrogen atmosphere at the appropriate elevated temperature. The materials that were finally selected included Kapton polyimide films, silicone adhesives, fiber glass batting, and in the case of the 350 F system, Teflon film.

Gille, J. P.↗

Development of an external ceramic insulation for the space shuttle orbiter. Part 2: Optimization

The basic insulation improvement study concentrated upon evaluating variables which could result in significant near-term gains in mechanical behavior and insulation effectiveness of the baseline system. The approaches undertaken included: evaluation of small diameter fibers, optimization of binder: slurry characteristics, evaluation of techniques for controlling fiber orientation, optimization of firing cycle, and the evaluation of methods for improving insulation efficiency. A detailed discussion of these basic insulation improvement studies is presented.

Tanzilli, R. A.↗

New insulation attachment method eliminates compatibility bondline stresses

Auger-shaped single-point fastener attaches rigid surface insulation tiles to orbiter shuttle spacecraft. Method can be used to bond wide variety of materials, including insulation, elastomers, and fibrous materials. Since insulation is attached at only one point, insulation and structure are free to form without inducing bond separation.

Schneider, W. C.↗

Insulation of nonlinear and random vibrations in the mining industry

The insulation of nonlinear and random vibrations is considered for some ore preparing and sorting implements: rotary crushers, resonance screens, hammer mills, etc. The appearance of subharmonic vibrations is analyzed, and the conditions for their appearance are determined. A method is given for calculating the insulation of these vibrations by means of elastic elements made of rubber. The insulation of the random vibrations produced by Symons crushers is calculated by determining the transmissability and deformation of the insulation system for a narrow band random response.

Zeveleanu, C.↗

High reliability sheathed, beryllia insulated, tungsten-rhenium alloy thermocouple assemblies; their fabrication and EMF stability

Tantalum sheathed, BeO insulated, W-3% Re/W-25% Re thermocouple assemblies were fabricated and their emf drift determined during 2059 hours of exposure at 2073 K in a gaseous helium environment. The sheathed thermocouple assemblies were constructed from aged thermoelements, specially heat-treated BeO insulators, and specially cleaned and etched tantalum sheaths. Their thermal emf drifts ranged from the equivalent of only -0.3 to -0.8 K drift per 1000 hours of exposure at 2073 K. No evidence of any gross chemical attack or degradation of the component materials was found. The emf drift and material behavior of some unsheathed, BeO insulated, W-3% Re/W-25% Re thermocouples at 2250 and 2400 K were also determined. Unsheathed thermocouples tested in an argon environment at 2250 K for 1100 hours and at 2400 K for 307 hours exhibited changes in thermal emf that typically ranged from the equivalent of a few degrees K to as much as +11 K. Post-test examinations of these thermocouples revealed some undesirable material degradation and interaction which included erosion of the BeO insulators and contamination of the thermoelements by tantalum from the tantalum blackbody enclosure in which the thermocouples were contained.

Burns, G. W.↗