Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION MICROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The atomic nature of polymer-metal interactions in adhesion, friction and wear

Adhesion experiments with polytetra-fluoroethylene (PTFE) and polyimide contacting tungsten indicate that the polymers bond chemically to the clean metal surface. Polymer chain fragments which transfer to the surface of tungsten in field ion microscopy adhesion studies are highly oriented. Auger emission spectroscopy of PTFE transfer films to various metal surfaces indicates that the PTFE is bonded to the metal surface via the carbon atom. With PTFE in sliding contact with different orientations of aluminum, metal orientation is found to influence surfaces in sliding. The lowest friction and least amount of surface damage is detected on the highest atomic density (111) plane. The friction process itself can initiate polymer film formation from simple organic molecules.

Buckley, D. H.↗

The atomic nature of polymer-metal interactions in adhesion, friction and wear

The adhesion, friction, and wear behavior of the solid polymers PTFE and polyimide in contact with various metals were studied using field ion microscopy, Auger emission spectroscopy, and scanning electron microscopy. Results indicate that the polymers will transfer to a clean tungsten surface on simple tough contact, forming a chemical bond. With PTFE, it is hypothesized that the bonding is of the carbon to the metal surface, while with the polyimide, both oxygen and carbon bonding to the tungsten surface are possible. In sliding contact, the friction process itself can initiate polymer film formation. The formation of such films has been suggested as a form of extreme pressure lubrication.

Buckley, D. H.↗

Wear and interfacial transport of material

Bonding across the interface for two solids in contact and the subsequent transfer of material from one surface to another is a direct result of the interfacial bonds being stronger than the cohesive bonds in either of the two solids. Surface tools such as LEED, Auger emission spectroscopy, field ion microscopy, and the atom probe are used to examine adhesive contacts and to determine the direction, nature, quantity of material transfer and properties of the solids which effect transfer and wear. The electronic nature, cohesive binding energies, surface structure, lattice disregistry and distribution of species in surface layers are all found to effect adhesion and transfer or transport for clean surfaces in solid state contact. The influence of adsorbed and reacted surface films from fractions of a monolayer to multilayer reactive films are considered. It is shown that even fractions of a monolayer of surface active species such as oxygen and sulfur can markedly inhibit adhesion and transport.

Buckley, D. H.↗

The metal to metal interface and its effect on adhesion and friction

The paper considers the interface between two bulk metals and the effect of this interface on adhesive bonding, resistance to tangential displacements, friction and the interfacial transport from one surface to another. Using Auger emission spectroscopy, field ion microscopy, and low energy electron diffraction techniques, the influence of surface orientation, lattice registry, crystal lattice structure and defects, metal surface chemistry and alloying on the characteristics of the interface was studied for noble, platinum, transition, and Group 4B metals. With dissimilar metals in contact, epitaxial transfer of the cohesively weaker to the cohesively stronger metal has been observed. Surface chemical activity of the noble and platinum metals is shown to affect interfacial behavior as does a valence bonding in the transition metals, and the degree of metallic nature in the Group 4B elements. Alloying elements, e.g., Si and Fe, can alter interfacial behavior by segregation to the surface of metals or by altering bulk properties such as crystal transformation kinetics.

Buckley, D. H.↗

In situ transmission electron microscopy with dual ion beam irradiation and implantation

To study the helium effects and their interactions with displacement damage in irradiated materials, an in situ dual-ion beam irradiation capability with transmission electron microscopy was recently established at the IVEM-Tandem Facility at Argonne National Laboratory. Pure nickel was irradiated in situ individually with 1 MeV Kr ions for displacement damage study, 16 keV He ions for helium implantation, and simultaneously with 1 MeV Kr ions and 16 keV He ions at the rate of 1 at.% He/dpa to study the interaction of helium and displacement damage at 500 degrees C. Helium bubbles were formed and segregated within dislocation loops during the He implantation experiment and no bubbles were observed outside the loops. The loop size increased with increasing helium concentration. In contrast, helium bubbles were formed uniformly in the matrix when nickel was irradiated simultaneously with 1 MeV Kr ions and 16 keV He ions. Overall, it is suggested that the uniformly-distributed defect clusters formed under 1 MeV Kr ion irradiation serve as trapping sites of helium atoms resulting in homogeneous nucleation of helium bubbles under the dualion beam irradiation in nickel.

36 MATERIALS SCIENCE↗

Comparison of SOFC Cathode Microstructure Quantified using X-ray Nanotomography and Focused Ioni Beam-scanning Electron Microscopy

X-ray nanotomography and focused ion beam scanning electron microscopy (FIB-SEM) have been applied to investigate the complex 3D microstructure of solid oxide fuel cell (SOFC) electrodes at spatial resolutions of 45 nm and below. The application of near edge differential absorption for x-ray nanotomography and energy selected backscatter detection for FIB-SEM enable elemental mapping within the microstructure. Using these methods, non-destructive 3D x-ray imaging and FIB-SEM serial sectioning have been applied to compare three-dimensional elemental mapping of the LSM, YSZ, and pore phases in the SOFC cathode microstructure. The microstructural characterization of an SOFC cathode is reported based on these measurements. The results presented demonstrate the viability of x-ray nanotomography as a quantitative characterization technique and provide key insights into the SOFC cathode microstructure.

30 DIRECT ENERGY CONVERSION↗

Heavy ion radiation effects studies with ion photon emission microscopy.

The development of a new radiation effects microscopy (REM) technique is crucial as emerging semiconductor technologies demonstrate smaller feature sizes and thicker back end of line (BEOL) layers. To penetrate these materials and still deposit sufficient energy into the device to induce single event effects, high energy heavy ions are required. Ion photon emission microscopy (IPEM) is a technique that utilizes coincident photons, which are emitted from the location of each ion impact to map out regions of radiation sensitivity in integrated circuits and devices, circumventing the obstacle of focusing high-energy heavy ions. Several versions of the IPEM have been developed and implemented at Sandia National Laboratories (SNL). One such instrument has been utilized on the microbeam line of the 6 MV tandem accelerator at SNL. Another IPEM was designed for ex-vacu use at the 88 cyclotron at Lawrence Berkeley National Laboratory (LBNL). Extensive engineering is involved in the development of these IPEM systems, including resolving issues with electronics, event timing, optics, phosphor selection, and mechanics. The various versions of the IPEM and the obstacles, as well as benefits associated with each will be presented. In addition, the current stage of IPEM development as a user instrument will be discussed in the context of recent results.

43 PARTICLE ACCELERATORS↗

Comparison of the Chromium Distribution in New Super Koropon Primer to 30 Year Old Super Koropon Using Focused Ion Beam/Scanning Electron Microscopy

Super Koropon primer (MB0125-055) plays a significant role in the corrosion protection of areas throughout the Orbiter. Because the Shuttle Program relies so heavily upon the performance of the Koropon primer, it is necessary to fully understand all aspects of the behavior of the coating. One area where little understanding of the Koropon primer still exists is the level of risk associated with age related degradation. Recently, efforts were undertaken to better understand the age life of the Koropon primer and to gain some insight into the aging process of this coating. In that study, an aluminum access panel from the Orbiter Enterprise was used to investigate the performance of the old Koropon film. A control panel was also used to study the performance of new Koropon coating. Preliminary investigations into the performance of aged Super Koropon primer indicated a significant decrease in corrosion protection. This investigation serves as an example of how Focused Ion Beam/Scanning Microscopy can be used to characterize the changes that occur as coatings age.

Lomness, Janice K.↗

Heavy Ion Radiation Effects Studies With Ion Photon Emission Microscopy

The development of a new radiation effects microscopy (REM) technique is crucial as emerging semiconductor technologies demonstrate smaller feature sizes and thicker back end of line (BEOL) layers. To penetrate these materials and still deposit sufficient energy into the device to induce single event effects, high energy heavy ions are required. Ion photon emission microscopy (IPEM) is a technique that utilizes coincident photons, which are emitted from the location of each ion impact to map out regions of radiation sensitivity in integrated circuits and devices, circumventing the obstacle of focusing high-energy heavy ions. Several versions of the IPEM have been developed and implemented at Sandia National Laboratories (SNL). One such instrument has been utilized on the microbeam line of the 6 MV tandem accelerator at SNL. Another IPEM was designed for ex-vacu use at the 88'' cyclotron at Lawrence Berkeley National Laboratory (LBNL). Extensive engineering is involved in the development of these IPEM systems, including resolving issues with electronics, event timing, optics, phosphor selection, and mechanics. The various versions of the IPEM and the obstacles, as well as benefits associated with each will be presented. In addition, the current stage of IPEM development as a user instrument will be discussed in the context of recent results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication of sharp tungsten-coated tip for atomic force microscopy by ion-beam sputter deposition

Tungsten (W) is significantly suitable as a tip material for atomic force microscopy (AFM) because its high mechanical stiffness enables the stable detection of tip-sample interaction forces. We have developed W sputter-coating equipment to compensate the drawbacks of conventional Si cantilever tips used in AFM measurements. By employing an ion gun commonly used for sputter cleaning of a cantilever tip, the equipment is capable of depositing conductive W films in the preparation chamber of a general ultrahigh vacuum (UHV)-AFM system without the need for an additional chamber or transfer system. This enables W coating of a cantilever tip immediately after sputter cleaning of the tip apex and just before the use in AFM observations. The W film consists of grain structures, which prevent tip dulling and provide sharpness (<3 nm in radius of curvature at the apex) comparable to that of the original Si tip apex. We demonstrate that in non-contact (NC)-AFM measurement, a W-coated Si tip can clearly resolve the atomic structures of a Ge(001) surface without any artifacts, indicating that, as a force sensor, the fabricated W-coated Si tip is superior to a bare Si tip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scanning Kelvin Probe Microscopy Reveals That Ion Motion Varies with Dimensionality in 2D Halide Perovskites

We study ion migration in 2D lead halide perovskites of varying dimensionality using scanning Kelvin probe microscopy (SKPM). We perform potentiometry on micrometer-scale lateral junctions in the absence of injected charge, and we compare how ion motion varies between prototypical two-dimensional n-butylammonium lead iodide perovskites (BA 2 PbI 4 , n = 1), and methylammonium-incorporated quasi-2D perovskites (BA 2 MA 3 Pb 4 I 13 , ~ < n > = 4) under the effects of illumination and temperature. We attribute the observed slow dynamics to relaxation of the bias-induced ionic charge distributions at different temperatures, and we extract the activation energies associated with the ionic motion in each case. Lastly, we propose an explanation for these phenomena by hypothesizing that ion motion in purely-2D BA 2 PbI 4 perovskite films is dominated by paired halide and halide vacancy, whereas for quasi-2D BA 2 MA 3 Pb 4 I 13 perovskites, the ion motion is a combination of both halide and methylammonium (vacancy) migration. These data show that dimensionality in these systems plays a critical role in ion dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemical Imaging Analysis of Environmental Particles Using the Focused Ion Beam/Scanning Electron Microscopy Technique. Microanalysis Insights into Atmospheric Chemistry of Fly Ash

Airborne fly ash from coal combustion may represent a source of bioavailable iron (Fe) in the open ocean. However, few studies have been made focusing on Fe speciation and distribution in coal fly ash. In this study, chemical imaging of fly ash has been performed using a dual-beam FIB/SEM (focused ion beam/scanning electron microscope) system for a better understanding of how simulated atmospheric processing modify the morphology, chemical compositions and element distributions of individual particles. A novel approach has been applied for cross-sectioning of fly ash specimen with a FIB in order to explore element distribution within the interior of individual particles. Our results indicate that simulated atmospheric processing causes disintegration of aluminosilicate glass, a dominant material in fly ash particles. Aluminosilicate-phase Fe in the inner core of fly ash particles is more easily mobilized compared with oxide-phase Fe present as surface aggregates on fly ash spheres. Fe release behavior depends strongly on Fe speciation in aerosol particles. The approach for preparation of cross-sectioned specimen described here opens new opportunities for particle microanalysis, particular with respect to inorganic refractive materials like fly ash and mineral dust.

Environmental Molecular Sciences Laboratory↗

A study of microstructural evolution of Fe-18Cr-8Ni, Fe-17Cr-12Ni, and Fe-20Cr-25Ni stainless steels after mechanical alloying and annealing

In this study, high-energy mechanical alloying technique was used to produce nanocrystalline stainless steels of three different compositions from elemental powders. The microstructural evolution (grain growth and phase transformation) as a function of alloy compositions and annealing temperatures were investigated by room and high temperature x-ray diffraction experiments, transmission electron microscopy and focused ion beam microscopy. The results revealed that stainless steels with low nickel content (i.e., Fe-18Cr-8Ni) underwent a deformation-induced martensitic transformation during room temperature mechanical alloying. Deformation-induced martensitic transformation with increasing nickel content (i.e., Fe-17Cr-12Ni and Fe-20Cr-25Ni) would not be possible by room temperature milling but was created by high strain rate cryogenic processing, the degree to which was compositional dependent. Post process annealing induced the reverse transformation from martensite-to-austenite the ratio of which was found to be a factor of alloy composition and annealing temperature. The real time in-situ x-ray studies showed that the martensite-to-austenite reverse transformation was completed at around 600 °C and 800 °C for Fe-18Cr-8Ni and Fe-20Cr-25Ni steels, respectively. Microscopy studies revealed a significant enhancement in the resistance to grain growth for Fe-17Cr-12Ni steel over other compositions at elevated temperatures as high as 1200 °C. As such, cryogenic processing following by reverse martensitic transformation of high Ni containing alloys provides a pathway for developing higher heat resistant stainless steel alloys.

36 MATERIALS SCIENCE↗

Probing the hydrolytic degradation of UF 4 in humid air

This manuscript describes the chemical transformations that occur during hydrolysis of uranium tetrafluoride (UF 4 ) due to its storage in humid air (85% and 50% relative humidity) at ambient temperatures. This hydrolysis was previously reported to proceed slowly or not at all (depending on the percent relative humidity); however, previous reports relied primarily on X-ray diffraction methods to probe uranium speciation. Here, we employ a battery of physiochemical probing techniques to explore potential hydrolysis, including Raman spectroscopy, powder X-ray diffraction, 19 F nuclear magnetic resonance spectroscopy, scanning electron microscopy, and focused ion beam microscopy with energy-dispersive X-ray spectroscopy. Of these, only Raman spectroscopy proved to be particularly useful at observing chemical changes to UF 4 . It was found that anhydrous UF 4 slightly oxidizes over the course of thirteen days to Schoepite-like uranium complexes and possibly UO 3 . In contrast, UF 4 exposed to 50% relative humidity slightly decomposes into UO 2 F 2 , Schoepite-like uranium complexes, and possibly a high order uranium oxide that eluded chemical assignment (U x O y ). Despite the rich chemical speciation observed in our Raman spectroscopy measurements, X-ray diffraction and 19 F NMR measurements on the same material showed no changes. Microscopy measurements suggest that the observed reactions between UF 4 and water occur primarily on the surface of UF 4 particulates via a method that is visually similar to surface corrosion of metals. Therefore, we postulate that NMR spectroscopy and X-ray diffraction, which are well-suited for bulk analysis, are less suited than Raman spectroscopy to observe the surface-based reactions that occur to UF 4 when exposed to humid air. Considering the importance of UF 4 in the production of nuclear fuel and weapons, the results presented herein are widely applicable to numerous nuclear science fields where uranium detection and speciation in humid environments is of value, including nuclear nonproliferation and nuclear forensics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗