Micromechanisms of thermomechanical fatigue: A comparison with isothermal fatigue

Thermomechanical Fatigue (TMF) experiments were conducted on Mar-M 200, B-1900, and PWA-1480 (single crystals) over temperature ranges representative of gas turbine airfoil environments. The results were examined from both a phenomenological basis and a micromechanical basis. Depending on constituents present in the superalloy system, certain micromechanisms dominated the crack initiation process and significantly influenced the TMF lives as well as sensitivity of the material to the type TMF cycle imposed. For instance, high temperature cracking around grain boundary carbides in Mar-M 200 resulted in short in-phase TMF lives compared to either out-of-phase or isothermal lives. In single crystal PWA-1480, the type of coating applied was seen to be the controlling factor in determining sensitivity to the type of TMF cycle imposed. Micromechanisms of deformation were observed over the temperature range of interest to the TMF cycles, and provided some insight as to the differences between TMF damage mechanisms and isothermal damage mechanisms. Finally, the applicability of various life prediction models to TMF results was reviewed. Current life prediction models based on isothermal data must be modified before being generally applied to TMF.

Bill, R. C.↗

Isothermal solidification in a binary alloy melt

A space shuttle experiment employing the General Purpose (Rocket) Furnace (GPF) in its isothermal mode of operation is manifested on MSL-3, circa 1989. The central aim of this experiment is to investigate the effect of reduced gravity levels on the segregation behavior in a slowly, and isothermally, cooled sample of a binary Pb-15 wt percent Sn alloy. This experiment would thus be able to simulate, in a small laboratory sample, about 20 mm dia 60 mm high and weighing about 150 grams, some aspects of the segregation phenomena occurring in large industrial ingots. Ground-based experiments conducted in the single-cavity simulator of the GPF, located at Marshall Space Flight Center (MSFC), in support of the microgravity experiment are described in detail. The results of the MSFC experiments are compared with other related experiments conducted at Case Western Reserve University (CWRU), wherein the isothermal constraints were relaxed.

Laxmanan, V.↗

Propagating and nonpropagating compression waves in an isothermal atmosphere with uniform horizontal magnetic field

Full analytical solutions to the wave equations for steady vertical compression waves in an isothermal hydrostatic atmosphere with a uniform horizontal magnetic field are presented. It is shown that, in the steady state approach, the behavior of upward waves and downward waves is very different. It is shown that the finding of Thomas (1983), indicating that the cutoff frequency for vertically propagating magnetoacoustic waves in an isothermal atmosphere with a horizontal magnetic field is the same for isothermal atmosphere with no magnetic field, is true only for the downward waves.

Musielak, Z. E.↗

Thermal barrier coating life and isothermal oxidation of low-pressure plasma-sprayed bond coat alloys

The paper investigates the isothermal oxidation kinetics of Ni-35Cr-6Al-0.95Y, Ni-18Cr-12Al-0.3Y, and Ni-16Cr-6Al-0.3Y low-pressure plasma-sprayed bond coat alloys and examines the effect of these alloys on the thermal barrier coating (TBC) cyclic life. TBC life was examined by cycling substrates coated with the different bond coats and a ZrO2-7 wt pct Y2O3 TBC in an air-rich burner rig flame between 1150 C and room temperature. The oxidation kinetics of the three bond coat alloys was examined by isothermal oxidation of monolithic NJiCrAlY coupons at 1083 C. The Ni-35Cr-6Al-0.95Y alloy exhibits comparatively high isothermal oxidation weight gains and provides the longest TBC life, whereas the Ni-16Cr-6Al-0.3Y alloy had the lowest weight gains and provided the shortest TBC life. The results show that, although bond coat oxidation is known to have a strong detrimental effect on TBC life, it is not the only bond coat factor that determines TBC life.

Brindley, W. J.↗

Statistical Design in Isothermal Aging of Polyimide Resins

Recent developments in research on polyimides for high temperature applications have led to the synthesis of many new polymers. Among the criteria that determines their thermal oxidative stability, isothermal aging is one of the most important. Isothermal aging studies require that many experimental factors are controlled to provide accurate results. In this article we describe a statistical plan that compares the isothermal stability of several polyimide resins, while minimizing the variations inherent in high-temperature aging studies.

Sutter, James K.↗

Initial Design and Experimental Results of a Novel Near-Isothermal Compressor for Heat Pump Applications

In efforts to increase the efficiency of residential and commercial air conditioners and heat pumps, it is found that the compressor has the highest electrical energy usage of the system. Therefore, it is appropriate to try to increase the efficiency of this component to reduce its energy usage. Another challenge with heat pump design is that some compressor types have drawbacks that make modulation difficult. To answer these challenges, we are developing an isothermal liquid compressor. The compressor uses propylene glycol to compress carbon dioxide. In the compression chamber the propylene glycol can enter either from the bottom to create a liquid piston for compression or it can enter through a spray nozzle at the top of the chamber. In the latter case, heat transfer from the gas to be compressed to the liquid droplets is high. This allows near isothermal operation of the compressor, which increases the efficiency by 17% to 30%, compared to adiabatic compression. In addition, the isothermal liquid compressor enables very efficient and simple part load modulation.Experimental results demonstrating the operation of the liquid compressor are presented. Initial data demonstrated a temperature rise of 7 K at pressure ratios of almost 4. For comparison at the same initial pressure, temperature, and pressure ratio, adiabatic compression would result in a temperature increase of approximately 70 K. Plotting data on a P-h diagram demonstrates that the compression started at superheated state and ended in supercritical state. Testing was later performed with repeated compressions in the superheated region of the P-h diagram at liquid flow rates of 2 x 10-3 m3/min and 2 x 10-3 m3/min to understand the limitations of the prototype for use with an actual heat pump system. This work demonstrated a novel cycle on a T-s diagram. Results from this work will be used to develop a second-generation prototype where more rapid cycling is possible.

Kowalski, Steve↗

Isothermal Martensitic and Pressure-Induced Delta to Alpha-Prime Phase Transformations in a Pu-Ga Alloy

A well-homogenized Pu-2 at.% Ga alloy can be retained in the metastable face-centered cubic {delta} phase at room temperature. Ultimately, this metastable {delta} phase will decompose via a eutectoid transformation to the thermodynamically stable monoclinic {alpha} phase and the intermetallic compound Pu{sub 3}Ga over a period of approximately 10,000 years [1]. In addition, these low solute-containing {delta}-phase Pu alloys are metastable with respect to an isothermal martensitic phase transformation to the {alpha}{prime} phase during low temperature excursions [2, 3] and are also metastable with respect to a {delta} {yields} {alpha}{prime} phase transformation with increases in pressure [3-5]. The low temperature {delta} {yields} {alpha}{prime} isothermal martensitic phase transformation in the Pu-2 at.% Ga alloy only goes to {approx}25% completion with the resultant {approx}20 {micro}m long by 2 {micro}m wide lath-shaped {alpha}{prime} particles dispersed within the {delta} matrix. In recently reported studies, Faure et al. [4] have observed a {delta} {yields} {gamma} {yields} {alpha}{prime} pressure-induced phase transformation sequence during a diamond anvil cell investigation and, based on x-ray diffraction and density and compressibility experiments, Harbur [5] has concluded that both {alpha}{prime} and an amorphous phase are present in samples that were pressurized and recovered. In this work, a large volume moissanite anvil cell is constructed to permit the pressurization and recovery of specimens of a size suitable for TEM and electron diffraction studies. The cell, shown in Fig. 1, has an overall diameter of 101.6 mm, a moissanite anvil diameter of 9.00 mm, a culet size of 3 mm, and a spring steel gasket 0.5 mm thick with a hole diameter of 2.5 mm. A 2.3 mm diameter by 100 {micro}m thick sample of {delta}-phase Pu-2 at.% Ga is compressed at a rate of approximately 0.05 GPa/minute to {approx}1 GPa to induce the phase transformation to {alpha}{prime}. Optical microscopy of the recovered specimen reveals a very fine microstructure that appears to be single phase, although the resolution of this technique is insufficient to differentiate between single and multiple phases if the grain size is below approximately 1 {micro}m. X-ray diffraction, using a laboratory Cu K{sub {alpha}} source with wavelength of 1.542{angstrom}, shows the monoclinic reflections from the {alpha}{prime} phase, strong peaks from the aluminum specimen holder, and weak peaks from the face-centered cubic {delta} phase as shown in Fig. 2. The recovered specimen is prepared for TEM and electron diffraction studies as described in Moore et al. [6]. TEM reveals small regions of {delta} phase with a very high dislocation density interspersed between the 10-100's nm {alpha}{prime} grains as shown in Fig. 3. Electron diffraction, shown in the insert in Fig. 3, clearly reveals the presence of the {delta} phase. This microstructure is in contrast to the {alpha}{prime} particles that form as a result of the low-temperature isothermal martensite in which the {alpha}{prime} particles are lath-shaped and significantly larger as shown in the optical micrograph in Fig. 4 of a sample cooled to -120 C and held for 10 hours. In these preliminary results, there is no evidence of either an amorphous phase, as suggested by Harbur [5], or the presence of a {gamma} phase. We expected to observe an amorphous phase based on the similarity of this experiment to that of Harbur [5]. It is possible that the {gamma} phase, as reported by Faure et al. [4], does form as an intermediate, but it is not retained to ambient pressure.

36 MATERIALS SCIENCE↗

BENCHMARK EVALUATION OF THE INITIAL ISOTHERMAL PHYSICS MEASUREMENTS AT THE FAST FLUX TEST FACILITY

The benchmark evaluation of the initial isothermal physics tests performed at the Fast Flux Test Facility, in support of Fuel Cycle Research and Development and Generation-IV activities at the Idaho National Laboratory, has been completed. The evaluation was performed using MCNP5 with ENDF/B-VII.0 nuclear data libraries and according to guidelines provided for inclusion in the International Reactor Physics Experiment Evaluation Project Handbook. Results provided include evaluation of the initial fully-loaded core critical, two neutron spectra measurements near the axial core center, 32 reactivity effects measurements (21 control rod worths, two control rod bank worths, six differential control rod worths, two shutdown margins, and one excess reactivity), isothermal temperature coefficient, and low-energy electron and gamma spectra measurements at the core center. All measurements were performed at 400 ºF. There was good agreement between the calculated and benchmark values for the fully-loaded core critical eigenvalue, reactivity effects measurements, and isothermal temperature coefficient. General agreement between benchmark experiment measurements and calculated spectra for neutrons and low-energy gammas at the core midplane exists, but calculations of the neutron spectra below the core and the low-energy gamma spectra at core midplane did not agree well. Homogenization of core components may have had a significant impact upon computational assessment of these effects. Future work includes development of a fully-heterogeneous model for comprehensive evaluation. The reactor physics measurement data can be used in nuclear data adjustment and validation of computational methods for advanced fuel cycle and nuclear reactor systems using Liquid Metal Fast Reactor technology.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reversible Phase Transitions Enable Cyclic Isothermal CO 2 Capture in Redox‐Activated Perovskite‐Structured Sorbents

Sorption‐enhanced steam reforming and gasification using CO 2 sorbents enable the production of H 2 ‐rich syngas from carbonaceous feedstocks but are limited by significant temperature swings and sintering‐induced activity loss. Perovskite‐structured oxides are presented herein as sintering‐resistant, redox‐activated isothermal CO 2 sorbents capable of overcoming these challenges by releasing lattice oxygen to partially oxidize the carbonaceous feedstock while capturing CO 2 , shifting equilibrium toward H 2 production. Building on this, the structural and thermodynamic impact of Fe doping on the CO 2 sorption properties of SrMn 1‐ x Fe x O 3‐ δ is investigated for sorption‐enhanced reforming. Experimental results demonstrate that these sorbents enable isothermal production of high‐quality, H 2 ‐enriched syngas from carbonaceous feedstocks. Laboratory and synchrotron‐based powder X‐ray diffraction analyses, coupled with density functional theory calculations, reveal the structural dynamics and energy landscape of the SrMn 1‐ x Fe x O 3‐ δ perovskite system under reaction conditions, elucidating the solid‐state reaction pathway and the effect of Fe doping on the extent of carbonation.

CO2 capture↗

Flexible-to-semiflexible chain crossover on the pressure-area isotherm of a lipid bilayer

We find theoretically that competition between {approx}K{sub f}q{sup 4} and {approx}Qq{sup 2} terms in the Fourier-transformed conformational energy of a single-lipid chain, in combination with interchain entropic repulsion in the hydrophobic part of the lipid (bi)layer, may cause a crossover on the bilayer pressure-area isotherm P(A){approx}(A-A{sub 0}){sup -{alpha}}. The crossover manifests itself in the transition from {alpha} = 5/3 to {alpha} = 3. Our microscopic model represents a single-lipid molecule as a worm-like chain with a finite irreducible cross-section area A{sub 0}, a flexural rigidity K{sub f}, and a stretching modulus Q in a parabolic potential with the self-consistent curvature B(A) formed by entropic interactions between hydrocarbon chains in the lipid layer. The crossover area A* obeys the relation Q/{radical}K{sub f}B(A*) {approx} 2. We predict a peculiar possibility of deducing the effective elastic moduli K{sub f} and Q of an individual hydrocarbon chain from the analysis of the isotherm with such a crossover. Also calculated is the crossover-related behavior of the area compressibility modulus K{sub A}, the equilibrium area per lipid A{sub t}, and the chain order parameter S({theta})

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Engineered, Spatially Varying Isothermal Holds: Enabling Combinatorial Studies of Temperature Effects, as Applied to Metastable Titanium Alloy β-21S

A novel method to systematically vary temperature and thus study the resulting microstructure of a material is presented. This new method has the potential to be used in a combinatorial fashion, allowing the rapid study of thermal holds on microstructures to be conducted. This is demonstrated on a beta titanium alloy, where the thermal history has a strong effect on microstructure. It is informed by simulation and executed using the resistive heating capabilities of a Gleeble 3800 thermomechanical simulator. Spatially varying isothermal holds of 4 h were affected, where the temperature range of the multiple isothermal holds varied by ~175 °C.

36 MATERIALS SCIENCE↗

Prediction of water vapour sorption isotherms and microstructure of hardened Portland cement pastes

Water vapour sorption isotherms of cementitious materials reflect the multi-scale physical microstructure through its interaction with moisture. Our ability to understand and predict adsorption and desorption behaviour is essential in the application of modern performance-based approaches to durability analysis, along with many other areas of hygro-mechanical and hygro-chemo-mechanical behaviour. In this paper, a new physically based model for predicting water vapour sorption isotherms of arbitrary hardened Portland cement pastes is presented. Established thermodynamic principles, applied to a microstructure model that develops with hydration, provide a rational basis for predictions. Closed-form differentiable equations, along with a rational consideration of hysteresis and scanning phenomena, makes the model suitable for use in numerical moisture simulations. The microstructure model is reconciled with recently published {sup 1}H NMR and mercury intrusion porosimetry results.

36 MATERIALS SCIENCE↗

Modelling of transport processes in concrete exposed to elevated temperatures – An alternative formulation for sorption isotherms

There is a significant need to understand, analyse and assess moisture transport in cementitious materials exposed to elevated temperatures in order to confidently predict the behaviour and ultimately the development of damage in safety critical applications such as nuclear reactor vessels, structures exposed to fire and well bore grouts. In view of this need a rigorous and robust formulation to describe water retention curves (sorption isotherms) as a function of temperature based on the evolution of physical parameters is presented. The model formulation is successfully validated against independent sets of experimental data up to temperatures of 80 °C. It is then further validated under isothermal drying conditions and then high temperature conditions through the numerical reproduction of laboratory experiments following implementation in a fully coupled hygro-thermo-mechanical finite element model. The new formulation is found to work well under a variety of conditions in a variety of cementitious material types.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

C–S–H gel densification: The impact of the nanoscale on self-desiccation and sorption isotherms

The relationship between humidity and water content in a hydrating cement paste is largely controlled by the nanostructure of the C–S–H gel. Current hydration models do not describe this nanostructure, thus sorption isotherms and self-desiccation are given as constitutive inputs instead of being predicted from microstructural evolution. To address this limitation, this work combines a C–S–H gel description from nanoscale simulations with evolving capillary pore size distributions from a simple hydration model. Results show that a progressive densification of the C–S–H gel must be considered in order to explain the self-desiccation of low-alkali pastes. The impact of C–S–H densification on the evolution of microstructure and sorption isotherms is then discussed, including the effect of water-to-cement ratio, cement powder fineness, and curing temperature. Overall, this work identifies an area where nanoscale simulations can integrate larger-scale models of cement hydration and poromechanics.

36 MATERIALS SCIENCE↗

Demonstrating non-isothermal vacuum membrane air dehumidification for efficient next-generation air conditioning

Vacuum membrane air dehumidification has gained significant interest in recent years as a highly efficient means of air dehumidification. Prior theoretical modeling work by the authors introduced the Active Membrane Energy Exchanger (AMX) concept, which combines active heat exchange and vacuum membrane dehumidification into one non-isothermal system, and found that it could outperform other air conditioning technologies under many conditions. However, no experimental literature exists on combining active heat exchangers and vacuum membrane dehumidification. Here, the goal of the present study is to evaluate the dehumidification (mass transfer) performance of the AMX concept relative to isothermal membrane dehumidification through three main methodologies: (1) membrane material-level characterization, (2) experimental prototype development and testing, and (3) computational fluid dynamics (CFD) simulations. The dense membranes used in this work showed up to a 40% increase in water vapor permeance at cooler temperatures, and the prototype system showed up to a 6% increase in humidity removal when the air was simultaneously cooled. Furthermore, the membrane module-integrated heat exchange tubes provided additional mixing and turbulence, leading to a 4–8% increase in humidity removal. The upper limit coefficient of performance was equal to approximately 2.2, necessitating advanced system designs to improve efficiency. This study is the first to highlight that combining the cooling and vacuum dehumidification processes can improve dehumidification performance.

30 DIRECT ENERGY CONVERSION↗

Near-isothermal-isobaric compressed gas energy storage

In this paper, the effectiveness of storing energy by compressing and expanding a condensable gas is evaluated. A high efficiency energy storage system, which stores energy by compressing/expanding gas (air) using a liquid (water) piston has been recently introduced and extensively studied. With the use of the liquid piston, the inefficient gas turbomachines used in conventional gas compression/expansion systems are replaced with high efficiency hydraulic machines. Utilizing heat transfer techniques and replacing the non-condensable air with a condensable gas (i.e. CO 2 , synthetic refrigerants, hydrocarbon refrigerants, etc.) have been proposed as methods to improve energy density and roundtrip efficiency of such systems, leading to near isothermal and near isobaric charge/discharge processes. In order to investigate the effectiveness of the proposed concept, a miniature lab-scale experimental setup was designed and built to investigate the compression/expansion characteristics and energy storage efficiency of a system utilizing R134a as the energy storage (primary) working fluid, and mineral refrigerant oil as the liquid piston (secondary) working fluid. Several tests are carried out to quantify energy storage efficiency and energy density. It is found that improving heat transfer rates from/into the storage fluid results in increased efficiency and energy density. A heat-transfer enhancement strategy to achieve near isothermal, isobaric expansion and compression is proposed and investigated experimentally. Some results are generalized and presented in non-dimensional form which can be applied to describe and/or design scaled-up systems. Lastly, a potential working fluid for a scaled-up system is discussed.

25 ENERGY STORAGE↗

An isothermal forming process with multi-stage variable speed for magnesium component assisted by sensitivity analysis

We have developed a multi-stage variable speed (MSV) isothermal forming process based on strain rate sensitivity (SRS) analysis, and successfully produced a large size of rib-web component of magnesium alloy from a cylindrical billet. The obtained rib-web component has been processed into parts for mechanical properties examination and the examination results met the standard of being safely used in aircrafts. The process parameters of the forming technology and microstructure change were explicitly linked by the SRS coefficient. The finite element (FE) simulation and SRS distribution were implemented to identify the relationship among process parameters, shaping characteristics, and microstructure development. The MSV speed process was employed for reducing the forming load, refining grain sizes and increasing the strength of the component. With the selected process parameters the maximum forming load was reduced to be less than 20 MN, which is 55.3% lower than that used in the same process with the initial constant speed unchanged. Fine dynamic recrystallization (DRX) were observed from all parts of the forged cover plate including the convex, ribs, and web region. It was also found that higher strain resulted in more uniform distribution of fine ß-Mg17Al12 precipitates and larger DRX volume fraction. Importantly the developed isothermal forming process with severe plastic deformation can be applied for obtaining grain refinement so improving the mechanical properties of Mg products.

Magnesium alloy, Isothermal forming, Multi-stage v↗

Simultaneous Absorption and Desorption Isotherms of Various Hydrogen and Deuterium Mixtures between 20 and 120 °C Are Used to Determine the Activity Coefficients for Palladium-Hydride Solutions

A test bed was constructed to measure the absorption and desorption isotherms for palladium hydride using H 2 , D 2 , and various H 2 /D 2 mixtures for temperatures in the range 20 °C ≤ T ≤ 120 °C. The pressure–composition–temperature isotherms were measured. The pressures obtained with mixtures between each pure isotope were monotonic, yet nonlinear. This nonlinear dependence of total pressure with feed gas protium concentration reveals the mixed isotope hydride system behaves nonideally. A thermodynamic model was adapted from the literature, which accounts for the nonideal nature of the mixed-isotope system. The measured data were used as constraints in this model in order to calculate the protium mole fractions in the hydride phase and the protium activity coefficients for palladium hydride at various temperatures and protium concentrations in the system. Knowing the protium mole fraction and activity coefficients allows for a priori calculation of the isotopologue distribution in the gas phase and the isotope distribution in the hydride phase, given a palladium temperature and equilibrium pressure.