Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image Comparison”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Analysis of single-mode Richtmyer–Meshkov instability using high-order incompressible vorticity-streamfunction and shock-capturing simulations

In this study, two- and three-dimensional simulation results obtained using a new high-order incompressible, variable-density vorticity–streamfunction (VS) method and data from previous ninth-order weighted essentially nonoscillatory (WENO) shock-capturing simulations are used to investigate the nonlinear dynamics of single-mode Richtmyer–Meshkov instability using a model of a Mach 1.3 air(acetone)/SF6 shock tube experiment. A comparison of the density fields from both simulations with the experimental images demonstrates very good agreement in the large-scale structure with both methods but differences in the small-scale structure. The WENO method captures the small-scale disordered structure observed in the experiment, while the VS method partially captures such structure and yields a strong rotating core. The perturbation amplitude growth from the simulations generally agrees well with the experiment. The simulation bubble and spike amplitudes agree well at early times. At later times, the WENO bubble amplitude is smaller than the VS amplitude and vice versa for the spike amplitude. The predictions of nonlinear single-mode instability growth models are shown to agree with the simulation amplitudes at early-to-intermediate times but underpredict the amplitudes at later times in the nonlinear regime. Visualizations of the mass fraction and enstrophy isosurfaces, velocity and vorticity fields, and baroclinic vorticity production and vortex stretching terms from the three-dimensional simulations indicate that, with the exception of the small-scale structure within the rollups, the VS and WENO results are in good agreement.

42 ENGINEERING↗

A Framework for International Collaboration on ITER Using Large-Scale Data Transfer to Enable Near-Real-Time Analysis

The global nature of the ITER project along with its projected ~ petabyte per day data generation presents a unique challenge, but also an opportunity for the fusion community to rethink, optimize, and enhance our scientific discovery process. Recognizing this, collaborative research with computational scientists was undertaken over the past several years to create a framework for large-scale data movement across wide-area networks (WANs), to enable global near-real time analysis of fusion data. This would broaden the available computational resources for analysis/simulation, and increase the number of researchers actively participating in experiments. An official demonstration of this framework for fast, large data transfer and real-time analysis was carried out between the KSTAR tokamak in Daejeon, Korea and PPPL in Princeton, USA. Streaming large data transfer, with near real-time movie creation and analysis of the KSTAR Electron Cyclotron Emission imaging (ECEI) data, was performed using the I/O framework ADIOS, and comparisons made at PPPL with simulation results from the XGC1 code. These demonstrations were made possible utilizing an optimized network configuration at PPPL, which achieved over 8.8 Gbps (88% utilization) in throughput tests from NFRI to PPPL. This demonstration showed the feasibility for large-scale data analysis of KSTAR data, and provides a nascent framework to enable use of globally distributed computational and personnel resources in pursuit of scientific knowledge from the ITER experiment.

43 PARTICLE ACCELERATORS↗

Performance of a coarsely pixelated LAPPD photosensor for the SoLID gas Cherenkov detectors

The SoLID spectrometer's gas Cherenkov counters require photosensors that operate in a high luminosity and high background environment. The reference design features arrays of 9 or 16 tiled multi-anode photomultipliers (MaPMTs), distributed across 32 sectors, to serve the light-gas and heavy-gas Cherenkov counters, respectively. To assess the viability of a pixelated INCOM Large Area Picosecond Photodetector (LAPPD TM ) as an alternative photosensor to replace MaPMT arrays in either detector, we evaluated its performance under realistic SoLID running conditions in Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). The results of this test confirmed that the coarse-pixelated (2.5 × 2.5 cm 2 pixel size) LAPPD is capable of handling the total projected signal and background rates of the three pillar SoLID experiments. The tested photosensor detected Cherenkov signals with the capability of separating single-electron events from pair production events while rejecting background. Although the design was not aimed at ring-imaging Cherenkov detectors, Cherenkov disk images were captured in two different gas radiators. Through a direct comparison with a GEANT4 simulation, we confirmed the experimental performance of the LAPPD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identifying Periodic Variable Stars and Eclipsing Binary Systems with Long-term Las Cumbres Observatory Photometric Monitoring of ZTF J0139+5245

We present the results of our search for variable stars using the long-term Las Cumbres Observatory (LCO) monitoring of white dwarf ZTF J0139+5245 with the two 1.0 m telescope nodes located at McDonald Observatory using the Sinistro imaging instrument. In this search, we find 38 variable sources, of which 27 are newly discovered or newly classified (71%) based on comparisons with previously published catalogs, thereby increasing the number of detections in the field of view under consideration by a factor of ≈2.5. We find that the improved photometric precision per exposure due to longer exposure time for LCO images combined with the greater time sampling of LCO photometry enables us to increase the total number of detections in this field of view. Each LCO image covers a field of view of 26' × 26' and observes a region close to the Galactic plane (b = -9.°4) abundant in stars with an average stellar density of ≈8 arcmin{sup -2}. We perform aperture photometry and Fourier analysis on over 2000 stars across 1560 LCO images spanning 537 days to find 28 candidate BY Draconis variables, three candidate eclipsing binaries of type EA, and seven candidate eclipsing binaries of type EW. In assigning preliminary classifications to our detections, we demonstrate the applicability of the Gaia color–magnitude diagram as a powerful classification tool for variable-star studies.

47 OTHER INSTRUMENTATION↗

Shock generated vorticity in spark discharges

Spark discharges induce a complex flow field consisting of a shock wave at early times (~ 1 μs), a pair of vortex rings, and a hot gas kernel. The vortex rings entrain ambient gas into the hot gas kernel and control its cooling and expansion. In this work, we investigate the shock wave's contribution in producing the vortex ring vorticity. We analyze high-speed (700 kHz) schlieren images of the shock wave for a range of electrical energies to measure the shock properties and estimate shock velocity and curvature. These measurements are combined with a model to calculate the vorticity generated. The measurements show that the highest vorticity is generated near the peak shock curvature location, and the shock curvature and strength increase with electrical energy deposited. A comparison of the vorticity estimated from the model to vorticity measurements from stereoscopic particle image velocimetry shows the results to be statistically equivalent. Furthermore, this suggests that the shock curvature and velocity contribute to the vortex rings induced by spark discharges.

42 ENGINEERING↗

First Experiments and Radiographs on the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) Dense Plasma Focus

We report a dense plasma focus (DPF) is a relatively compact coaxial plasma gun, which completes its discharge as a Z-pinch. These devices are designed to operate at a variety of scales to produce short (<100 ns) pulses of ions, X-rays, and/or neutrons. LLNL recently constructed and brought into operation a new device, the MegaJOuLe Neutron Imaging Radiography (MJOLNIR) DPF, which is designed for radiography and high-yield operations. This device has been commissioned and has achieved neutron yields of up to 3.8E11 neutrons/pulse at 2.5-MA peak current while operating at up to 1 MJ of stored energy in its original pulsed power configuration. MJOLNIR is equipped with a wide range of diagnostics, including nuclear activation detectors, neutron time-of-flight (nToF) detectors, a fast-framing camera, optical light gates, and a time-gated neutron and X-ray imager. LLNL also runs unique particle-in-cell (PIC) simulations of DPF discharges in the Chicago code and has gained significant insight into the various physical factors that influence neutron yield. MJOLNIR is one of the first DPFs whose design and continual upgrades are heavily influenced by model predictions. In this article, we describe insights from modeling, device operation, and recent results. Comparisons between modeling predictions and measurements, as well as X-ray and neutron images are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

First Sagittarius A* Event Horizon Telescope Results. I. The Shadow of the Supermassive Black Hole in the Center of the Milky Way

We present the first Event Horizon Telescope (EHT) observations of Sagittarius A* (Sgr A*), the Galactic center source associated with a supermassive black hole. These observations were conducted in 2017 using a global interferometric array of eight telescopes operating at a wavelength of λ = 1.3 mm. The EHT data resolve a compact emission region with intrahour variability. A variety of imaging and modeling analyses all support an image that is dominated by a bright, thick ring with a diameter of 51.8 ± 2.3 μas (68% credible interval). The ring has modest azimuthal brightness asymmetry and a comparatively dim interior. Using a large suite of numerical simulations, we demonstrate that the EHT images of Sgr A* are consistent with the expected appearance of a Kerr black hole with mass ∼4 × 10$^{6}$ M $_{⊙}$, which is inferred to exist at this location based on previous infrared observations of individual stellar orbits, as well as maser proper-motion studies. Our model comparisons disfavor scenarios where the black hole is viewed at high inclination (i > 50°), as well as nonspinning black holes and those with retrograde accretion disks. Our results provide direct evidence for the presence of a supermassive black hole at the center of the Milky Way, and for the first time we connect the predictions from dynamical measurements of stellar orbits on scales of 10$^{3}$–10$^{5}$ gravitational radii to event-horizon-scale images and variability. Furthermore, a comparison with the EHT results for the supermassive black hole M87* shows consistency with the predictions of general relativity spanning over three orders of magnitude in central mass.

79 ASTRONOMY AND ASTROPHYSICS↗

Ultra-Fast Electron Microscopic Imaging of Single Molecules With a Direct Electron Detection Camera and Noise Reduction

Time-resolved imaging of molecules and materials made of light elements is an emerging field of transmission electron microscopy (TEM), and the recent development of direct electron detection cameras, capable of taking as many as 1,600 fps, has potentially broadened the scope of the time-resolved TEM imaging in chemistry and nanotechnology. However, such a high frame rate reduces electron dose per frame, lowers the signal-to-noise ratio (SNR), and renders the molecular images practically invisible. Here, we examined image noise reduction to take the best advantage of fast cameras and concluded that the Chambolle total variation denoising algorithm is the method of choice, as illustrated for imaging of a molecule in the 1D hollow space of a carbon nanotube with ~1 ms time resolution. Through the systematic comparison of the performance of multiple denoising algorithms, we found that the Chambolle algorithm improves the SNR by more than an order of magnitude when applied to TEM images taken at a low electron dose as required for imaging at around 1,000 fps. Open-source code and a standalone application to apply Chambolle denoising to TEM images and video frames are available for download.

47 OTHER INSTRUMENTATION↗

Laser-driven ultrafast transmission electron microscopy

Recent advances in lasers and electron optics technology have allowed transmission electron microscopes to achieve high spatial and temporal resolution, making them capable of tracking atoms, charges and spin motions down to the attosecond and nanometre scales. This Primer discusses the most common and practical experimental implementation of time-resolved transmission electron microscopy and the stroboscopic mode for evaluating ultrafast reversible dynamics. An in-depth discussion of photo-induced near-field electron microscopy, a technique unique to laser-assisted electron microscopy, is also provided, covering its prospective applications in the study of coherent phenomena in quantum materials. The experimental strategies and limitations in investigating the structural dynamics of materials and nanostructures by imaging, diffraction and spectroscopy are also described in detail, with a direct comparison with more conventional and established techniques. Here, we provide key information for new researchers who intend to use ultrafast transmission electron microscopy to address new challenges in specific materials science, condensed matter and nanophotonics.

Transmission electron microscopy↗

Observation of electron orbital signatures of single atoms within metal-phthalocyanines using atomic force microscopy

Resolving the electronic structure of a single atom within a molecule is of fundamental importance for understanding and predicting chemical and physical properties of functional molecules such as molecular catalysts. However, the observation of the orbital signature of an individual atom is challenging. We report here the direct identification of two adjacent transition-metal atoms, Fe and Co, within phthalocyanine molecules using high-resolution noncontact atomic force microscopy (HR-AFM). HR-AFM imaging reveals that the Co atom is brighter and presents four distinct lobes on the horizontal plane whereas the Fe atom displays a “square” morphology. Pico-force spectroscopy measurements show a larger repulsion force of about 5 pN on the tip exerted by Co in comparison to Fe. Our combined experimental and theoretical results demonstrate that both the distinguishable features in AFM images and the variation in the measured forces arise from Co’s higher electron orbital occupation above the molecular plane. The ability to directly observe orbital signatures using HR-AFM should provide a promising approach to characterizing the electronic structure of an individual atom in a molecular species and to understand mechanisms of certain chemical reactions.

36 MATERIALS SCIENCE↗

Probabilistic Inference of Low-Surface-Brightness Galaxy Morphological Parameters Using Simulation-Based Inference

Low-surface-brightness galaxies (LSBGs) are diffuse, often dark-matter-dominated systems whose faintness makes their structural parameters difficult to measure reliably in wide-field imaging surveys. Robust parameter inference, including uncertainty quantification, is important for population studies and for comparisons with models of galaxy formation, as future surveys are expected to produce increasingly large samples of diffuse galaxies. In practice, LSBG profile modeling is sensitive to sky- background errors, masking choices, contaminating background sources, and the computational cost of obtaining posterior-level uncertainties for large samples. Motivated by these questions, we develop a simulation-based inference (SBI) framework for estimating posterior distributions of LSBG morphological parameters from simulated galaxy images. Using PyImfit, we generate DES-like single-Sersic profile LSBG images with known position angle, ellipticity, Sersic index, effective surface brightness, and effective radius. We then train a normalizing-flow-based neural posterior estimator using the sbi package to infer these parameters from the simulated images. For isolated simulated galaxies, the SBI posterior recovers the true input parameters, produces posterior predictive residuals consistent with the assumed noise model, and shows good empirical calibration in a DES-motivated test regime. We also compare SBI with PyImfit-based MCMC inference and find broadly comparable posterior constraints, while SBI enables substantially faster posterior sampling after training. Finally, we test robustness to compact background contaminants. A model trained only on isolated galaxies produces undercovered posteriors on contaminated images, whereas training on simulations with variable contaminant positions and fluxes improves calibration across contaminated test sets. These results demonstrate the promise of SBI for scalable, uncertainty-aware LSBG morphology inference, while emphasizing that posterior reliability strongly depends on whether training simulations include relevant observational complications.

Batbayar, Bilguun [U. Chicago (main)]↗

A prototype scintillator real‐time beam monitor for ultra‐high dose rate radiotherapy

Background: FLASH Radiotherapy (RT) is an emergent cancer RT modality where an entire therapeutic dose is delivered at more than 1000 times higher dose rate than conventional RT. For clinical trials to be conducted safely, a precise and fast beam monitor that can generate out-of-tolerance beam interrupts is required. This paper describes the overall concept and provides results from a prototype ultra-fast, scintillator-based beam monitor for both proton and electron beam FLASH applications. Purpose: A FLASH Beam Scintillator Monitor (FBSM) is being developed that employs a novel proprietary scintillator material. The FBSM has capabilities that conventional RT detector technologies are unable to simultaneously provide: (1) large area coverage; (2) a low mass profile; (3) a linear response over a broad dynamic range; (4) radiation hardness; (5) real-time analysis to provide an IEC-compliant fast beam-interrupt signal based on true two-dimensional beam imaging, radiation dosimetry and excellent spatial resolution. Methods: The FBSM uses a proprietary low mass, less than 0.5 mm water equivalent, non-hygroscopic, radiation tolerant scintillator material (designated HM: hybrid material) that is viewed by high frame rate CMOS cameras. Folded optics using mirrors enable a thin monitor profile of ∼10 cm. A field programmable gate array (FPGA) data acquisition system generates real-time analysis on a time scale appropriate to the FLASH RT beam modality: 100–1000 Hz for pulsed electrons and 10–20 kHz for quasi-continuous scanning proton pencil beams. An ion beam monitor served as the initial development platform for this work and was tested in low energy heavy-ion beams ( 86 Kr +26 and protons). A prototype FBSM was fabricated and then tested in various radiation beams that included FLASH level dose per pulse electron beams, and a hospital RT clinic with electron beams. Results: Results presented in this report include image quality, response linearity, radiation hardness, spatial resolution, and real-time data processing. Furthermore, the HM scintillator was found to be highly radiation damage resistant. It exhibited a small 0.025%/kGy signal decrease from a 216 kGy cumulative dose resulting from continuous exposure for 15 min at a FLASH compatible dose rate of 237 Gy/s. Measurements of the signal amplitude versus beam fluence demonstrate linear response of the FBSM at FLASH compatible dose rates of >40 Gy/s. Comparison with commercial Gafchromic film indicates that the FBSM produces a high resolution 2D beam image and can reproduce a nearly identical beam profile, including primary beam tails. The spatial resolution was measured at 35–40 µm. Tests of the firmware beta version show successful operation at 20 000 Hz frame rate or 50 µs/frame, where the real-time analysis of the beam parameters is achieved in less than 1 µs. Conclusions: The FBSM is designed to provide real-time beam profile monitoring over a large active area without significantly degrading the beam quality. A prototype device has been staged in particle beams at currents of single particles up to FLASH level dose rates, using both continuous ion beams and pulsed electron beams. Using a novel scintillator, beam profiling has been demonstrated for currents extending from single particles to 10 nA currents. Radiation damage is minimal and even under FLASH conditions would require ≥50 kGy of accumulated exposure in a single spot to result in a 1% decrease in signal output. Beam imaging is comparable to radiochromic films, and provides immediate images without hours of processing. Real-time data processing, taking less than 50 µs (combined data transfer and analysis times), has been implemented in firmware for 20 kHz frame rates for continuous proton beams.

2D beam imaging↗

CHESS 2025: Spectrometer orthorectified at-sensor radiance from NEON AOP imaging spectroscopy surveys

This dataset provides Level 1 (L1) orthorectified at-sensor radiance derived from measurements collected by the Imaging Spectrometer-1 (NIS-1) onboard the NEON (National Ecological Observatory Network) Airborne Observation Platform (AOP) for the 2025 Colorado Headwaters Ecological Spectroscopy Study (CHESS). NIS-1 captures light reflected from the Earth’s surface in 426 discrete wavelength bands as raw digital numbers (DNs; Level 0). These data are then calibrated to physical units (uW/cm²·sr·nm) following the processing steps described in the NEON Imaging Spectrometer Level 1B Calibrated Radiance Algorithm Theoretical Basis Document (ATBD; Gallery 2022). The data delivered here are the primary inputs for the surface reflectance product in “Custom surface reflectance, shade masks, and equivalent water thickness maps for the Colorado Headwaters Ecological Spectroscopy Study” (Carroll et al. 2026). For intertemporal comparison, the radiance data here are most directly relatable to the v2 radiance data in “NEON AOP Imaging Spectroscopy Survey of Upper East River Colorado Watersheds: Raw-Space Radiance and Observational Variable Dataset” (Goulden et al. 2018), to which the same processing methodology was applied. Together, the radiance and reflectance data enable users to exploit the unique reflection signatures of different surface objects for land cover classification, foliar trait mapping, plant vigor assessment, water content estimation, trace-element identification, and other scientific applications. The data were acquired over three study domains in the Upper Gunnison river basin: the upper East River watershed (CRBU); Almont Triangle and Taylor Canyon (ALMO); and Upper Taylor River watershed (UPTA) between 2025-06-13 and 2025-07-15. Within each domain, data are delivered by flightline as orthorectified and calibrated hyperspectral rasters in Hierarchical Data Format version 5 (HDF5) format, with radiance values provided in uW/cm²·sr·nm on a fixed, uniform Universal Transverse Mercator (UTM) grid at 1 meter spatial resolution. The radiance rasters include all 426 NIS-1 spectral bands, along with associated quality-assurance (QA) and diagnostic and ancillary layers needed for atmospheric correction workflows. Orthorectified radiance is produced from pushbroom spectrometer observations by applying NEON’s radiometric calibration (including bad pixel masking, dark subtract, dark pedestal shift correction, electronic panel ghost correction, grating ghost correction, deblur correction and flat-fielding) and spectral calibration (using spectral response function band centers and full-width at half-maximum intensity), followed by geolocation and regridding to the fixed grid. CHESS Project Description: The Colorado Headwaters Ecological Spectroscopy Study (CHESS) comprised a multi-week airborne remote sensing and field observation campaign in the Upper Gunnison Basin, Colorado, conducted in June and July of 2025. Airborne remote sensing was conducted by the National Ecological Observatory Network Airborne Observation Platform (NEON AOP), concurrent with a field campaign run by the Rocky Mountain Biological Laboratory (RMBL), the Lawrence Berkeley National Laboratory (LBNL) and SLAC National Accelerator Laboratory Watershed Function Science Focus Area (SFA), and NASA-JPL (Jet Propulsion Laboratory) Earth Surface Mineral Dust Source Investigation (EMIT) program. Between June 10 and July 18, 2025, the NEON AOP flight team collected high-resolution aerial imaging spectroscopy and Light Detection and Ranging (LiDAR) data over three domains: the Upper East River (CRBU), Almont Triangle (ALMO), and the Upper Taylor Basin (UPTA). In coordination with the flights, a field campaign acquired ground-truth observations, including observations of vegetation composition, foliar traits, forest demography, and subsurface properties in 18 core sampling areas within the domains. Additional surface water observations were taken at over 380 point locations. All CHESS campaign datasets can be found within the CHESS ESS-DIVE data portal: https://data.ess-dive.lbl.gov/portals/chess. Funding Acknowledgement: Field and remote-sensing data acquisition was performed under a grant from the National Aeronautics and Space Administration (80NSSC24K1005). This work was also supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

2018 NEON and 2025 CHESS Campaigns↗

Comparison of atomized mass and crater volume in laser ablation

The extent and dynamics of laser ablation are typically studied using crater imaging or by invoking the relationship between atomic emission and the mass removed. The former is a static view of a dynamic process and requires the accumulation of multiple shots in one location. The latter is complex and not absolute without calibration of the optical system with a standard of spectral radiance. We measure the mass of the atomized plume by laser atomic-absorption spectroscopy at 2 µs without external mass calibration; mass uncertainty in laser-ablation atomic absorption spectroscopy (LA-AAS) results from uncertainties in line area fitting, tabulated oscillator strengths, and partition functions as well as a <10% underrepresentation of the mass due to treating the plasma as a single thermodynamic equilibrium. The LA-AAS-measured mass pertains to the atoms in the probed charge states and does not include condensed or molecular species. The ablation efficiency at 300 mbar of helium varies significantly between the two focusing conditions used. A comparison of crater-derived masses and LA-AAS masses suggests that more defocused ablation may result in significant redeposition of material in the crater, distorting the conclusions from drilling studies and crater imaging. More focused ablation conditions result in crater-derived masses that exceed those measured with LA-AAS and suggest melt expulsion or phase explosion.

Merten, Jonathan [Arkansas State University, Jones↗

Quantification of silicon carbide grain structure in TRISO fuel by BSE image analysis

The grain structure of the silicon carbide (SiC) layer in tristructural-isotropic (TRISO) fuels has commonly been qualified in fuel specifications based on a qualitative comparison to visual standards to ensure undesirable microstructure are not produced. This approach is inherently dependent on subjective judgement and provides limited data for analysis or comparison. An alternative method to rapidly quantify (i.e., provide a numeric measure of) the grain structure of the SiC layer in TRISO fuels has been developed. This method relies on the identification of silicon carbide grain boundaries based on brightness variation in backscattered electron (BSE) images through the application of automated image processing algorithms. The speed with which the requisite BSE imaging and analysis may be completed enables the practical use of this method on an industrial scale as a part of qualifying TRISO fuel to meet a given specification on silicon carbide grain structure, which is an important parameter for TRISO fuel performance. The method is benchmarked by comparison to prior Electron-Backscattered Diffraction (EBSD) results for TRISO particles from the Advanced Gas Reactor (AGR) program.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hygrothermal Aging and Thermomechanical Characterization of As-Manufactured Tidal Turbine Blade Composites

This study investigates the hygrothermal aging behavior and thermomechanical properties of as-manufactured glass fiber-reinforced epoxy and thermoplastic composite tidal turbine blades. The blades were previously deployed in a marine environment and subsequently analyzed through a comprehensive suite of material characterization techniques, including hygrothermal aging, dynamic mechanical analysis (DMA), tensile testing and X-ray computed tomography (XCT). Hygrothermal aging experiments revealed that while thermoplastic composites exhibited lower overall water absorption (0.78% vs. 0.47%), they had significantly higher diffusion coefficients than epoxy (2.1 vs. 12.1 × 10 −13 m 2 s −1 ), suggesting faster saturation in operational environments. DMA results demonstrated that water ingress caused plasticization in epoxy matrices, reducing the glass transition temperature and increasing damping (112 °C to 104 °C), while thermoplastic composites showed more stable thermal behavior (87 °C glass transition temperature). Tensile testing revealed substantial reductions in ultimate strength (>40%) for both materials after prolonged water exposure, with minimal change in elastic modulus, highlighting the role of matrix degradation over fiber reinforcement. XCT image analysis showed that both composites were manufactured with high quality: no large voids or cracks were present, and the degree of misalignment was low. These findings inform future marine renewable energy composite designs by emphasizing the critical influence of moisture on long-term structural integrity and the need for optimized material systems in harsh marine environments. This work provides a rare real-world comparison of epoxy and recyclable thermoplastic tidal turbine blades, showing how laboratory aging tests and advanced imaging reveal the influence of material and manufacturing choices on long-term marine durability.

16 TIDAL AND WAVE POWER↗

3D hybrid fluid-particle jet simulations and the importance of synchrotron radiative losses

Context. Relativistic jets in active galactic nuclei are known for their exceptional energy output, and imaging the synthetic synchrotron emission of numerical jet simulations is essential for a comparison with observed jet polarization emission. Aims. Through the use of 3D hybrid fluid-particle jet simulations (with the PLUTO code), we overcome some of the commonly made assumptions in relativistic magnetohydrodynamic (RMHD) simulations by using non-thermal particle attributes to account for the resulting synchrotron radiation. Polarized radiative transfer and ray-tracing (via the RADMC-3D code) highlight the differences in total intensity maps when (i) the jet is simulated purely with the RMHD approach, (ii) a jet tracer is considered in the RMHD approach, and (iii) a hybrid fluid-particle approach is used. The resulting emission maps were compared to the example of the radio galaxy Centaurus A. Methods. We applied the Lagrangian particle module implemented in the latest version of the PLUTO code. This new module contains a state-of-the-art algorithm for modeling diffusive shock acceleration and for accounting for radiative losses in RMHD jet simulations. The module implements the physical postulates missing in RMHD jet simulations by accounting for a cooled ambient medium and strengthening the central jet emission. Results. We find a distinction between the innermost structure of the jet and the back-flowing material by mimicking the radio emission of the Seyfert II radio galaxy Centaurus A when considering an edge-brightened jet with an underlying purely toroidal magnetic field. We demonstrate the necessity of synchrotron cooling as well as the improvements gained when directly accounting for non-thermal synchrotron radiation via non-thermal particles.

79 ASTRONOMY AND ASTROPHYSICS↗

Striatal dopamine synthesis and cognitive flexibility differ between hormonal contraceptive users and nonusers

In rodents and nonhuman primates, sex hormones are powerful modulators of dopamine (DA) neurotransmission. Yet less is known about hormonal regulation of the DA system in the human brain. Using positron emission tomography (PET), we address this gap by comparing hormonal contraceptive users and nonusers across multiple aspects of DA function: DA synthesis capacity via the PET radioligand 6-[ 18 F]fluoro-m-tyrosine ([ 18 F]FMT), baseline D2/3 receptor binding potential using [ 11 C]raclopride, and DA release using methylphenidate-paired [ 11 C]raclopride. Participants consisted of 36 healthy women (n = 15 hormonal contraceptive users; n = 21 naturally cycling/non users of hormonal contraception), and men (n = 20) as a comparison group. A behavioral index of cognitive flexibility was assessed prior to PET imaging. Hormonal contraceptive users exhibited greater DA synthesis capacity than NC participants, particularly in dorsal caudate, and greater cognitive flexibility. Furthermore, across individuals, the magnitude of striatal DA synthesis capacity was associated with cognitive flexibility. No group differences were observed in D2/3 receptor binding or DA release. Analyses by sex alone may obscure underlying differences in DA synthesis tied to women’s hormone status. Hormonal contraception (in the form of pill, shot, implant, ring, or intrauterine device) is used by ~400 million women worldwide, yet few studies have examined whether chronic hormonal manipulations impact basic properties of the DA system. Findings from this study begin to address this critical gap in women’s health.

59 BASIC BIOLOGICAL SCIENCES↗