Image management research

Two types of research issues are involved in image management systems with space station applications: image processing research and image perception research. The image processing issues are the traditional ones of digitizing, coding, compressing, storing, analyzing, and displaying, but with a new emphasis on the constraints imposed by the human perceiver. Two image coding algorithms have been developed that may increase the efficiency of image management systems (IMS). Image perception research involves a study of the theoretical and practical aspects of visual perception of electronically displayed images. Issues include how rapidly a user can search through a library of images, how to make this search more efficient, and how to present images in terms of resolution and split screens. Other issues include optimal interface to an IMS and how to code images in a way that is optimal for the human perceiver. A test-bed within which such issues can be addressed has been designed.

Watson, Andrew B.↗

Class of near-perfect coded apertures

Coded aperture imaging of gamma ray sources has long promised an improvement in the sensitivity of various detector systems. The promise has remained largely unfulfilled, however, for either one of two reasons. First, the encoding/decoding method produces artifacts, which even in the absence of quantum noise, restrict the quality of the reconstructed image. This is true of most correlation-type methods. Second, if the decoding procedure is of the deconvolution variety, small terms in the transfer function of the aperture can lead to excessive noise in the reconstructed image. It is proposed to circumvent both of these problems by use of a uniformly redundant array (URA) as the coded aperture in conjunction with a special correlation decoding method.

Cannon, T. M.↗

Chasing ghosts: characterization of artifact generation in coded aperture decoding due to experimental implementation

Coded aperture imaging is a form of lensless aperture imaging that projects multiple overlapping images of the source onto the detector, enhancing signal strength, which is advantageous for low-flux sources or high-resolution imaging. This technique requires decoding of the detector signal to reconstruct the original source, which involves convolving the detector data with the aperture pattern. When the signal is from a centered point source, the reconstructed source image is known as the point spread function (PSF). A clean PSF without artifacts is a Dirac delta function [Appl. Opt. 20, 1858 (1981)]. This paper examines the robustness of the decoding process against variations in experimental tolerances by analyzing artifact growth in the reconstructed PSF. We illustrate the effects of incorrect magnification, rotation, and detector size and find that aperture–detector rotational misalignment about the imaging axis is the most sensitive parameter, with significant artifact generation occurring with angular offsets of less than one degree. We discuss compensation methods for imperfect aperture placement, finding that small detector sizes produce uncompensatable artifact generation, and compare theoretical predictions with experimental PSF measurements of a rank , 6.8 mm thick (less than one mean free path) coded aperture with a 3.5 mm cell size, conducted at the MegaJOuLe Neutron Imaging Radiography dense plasma focus [IEEE Trans. Plasma Sci. 49, 3299 (2021)] using a 2.45 MeV neutron source. Based on our findings, we recommend using magnified coded apertures in the under-sampled regime, which allows for the inclusion of fiducial markers to characterize aperture–detector rotational offsets and the addition of mechanical coupling, where possible, to constrain rotational and magnification offsets.

Selwood, M. P. [Lawrence Livermore National Labora↗

The binary weight distribution of the extended (2 sup m, 2 sup m-4) code of Reed-Solomon code over GF(2 sup m) with generator polynomial (x-alpha sup 2) (x-alpha sup 3)

Consider an (n,k) linear code with symbols from GF(2 sup m). If each code symbol is represented by a binary m-tuple using a certain basis for GF(2 sup m), a binary (nm,km) linear code called a binary image of the original code is obtained. A lower bound is presented on the minimum weight enumerator for a binary image of the extended (2 sup m, 2 sup m -4) code of Reed-Solomon code over GF(2 sup m) with generator polynomical (x - alpha)(x- alpha squared)(x - alpha cubed) and its dual code, where alpha is a primitive element in GF(2 sup m).

Lin, Shu↗

A thick Anger camera for gamma-ray astronomy

The NaI(Tl) Anger camera is a natural candidate for a position sensitive detector in imaging of astrophysical gamma-ray sources. Here laboratory measurements are presented of the response of a relatively thick (5.1 cm) NaI(Tl) Anger camera designed for coded aperture imaging in the 50 keV to 2 MeV energy range. A position resolution of 10.5 mm FWHM at 122 keV and 6.3 mm FWHM at 662 keV. The energy resolution was 7 percent FWHM at 662 keV. The ability of the detector to resolve the depth of the gamma-ray interaction and the use of this depth resolution to reduce back-incident and internal background is discussed.

Cook, W. R.↗

Dust Morphology of Comet Hale-Bopp (C/1995 01). II. Introduction of a Working Model

A Monte Carlo image simulation code for dust features in comets is applied to comet Hale-Bopp in order to model the object's persistent porcupine-like appearance on high-resolution images taken between May 11 and November 2, 1996. In this scenario, the dust-emission profile is dominated by several brief flare-ups, or puffs in the production of dust from one of the sources.

comet↗

Recent results of gamma-ray imaging observations of the Galactic center and Crab/A0535 + 26 regions

Imaging observations at hard X-ray and gamma-ray energies of the Galactic center and Crab/A0535 + 26 regions are presented. The measurements were made in a series of high altitude balloon flights of a coded aperture gamma-ray telescope developed by Caltech. The first coded aperture images of the Galactic center region above 35 keV reveal a strong gamma-ray source located 0.7 + or - 0.1 deg away from the Galactic nucleus, consistent with the known X-ray source 1E1740.7 - 2942. In addition, a second source consistent in position with GX354 + 0 has been observed. Flux estimates and upper limits from two other known sources are also discussed. Coded aperture observations of the Crab and A0535 + 26 are presented, demonstrating the ability of coded aperture instruments to observe multiple time variable sources simultaneously.

Cook, W. R.↗

A programmable image compression system

A programmable image compression system which has the necessary flexibility to address diverse imaging needs is described. It can compress and expand single frame video images (monochrome or color) as well as documents and graphics (black and white or color) for archival or transmission applications. Through software control, the compression mode can be set for lossless or controlled quality coding; the image size and bit depth can be varied; and the image source and destination devices can be readily changed. Despite the large combination of image data types, image sources, and algorithms, the system provides a simple consistent interface to the programmer. This system (OPTIPAC) is based on the TITMS320C25 digital signal processing (DSP) chip and has been implemented as a co-processor board for an IBM PC-AT compatible computer. The underlying philosophy can readily be applied to different hardware platforms. By using multiple DSP chips or incorporating algorithm specific chips, the compression and expansion times can be significantly reduced to meet performance requirements.

Farrelle, Paul M.↗

International standards activities in image data compression

Integrated Services Digital Network (ISDN); coding for color TV, video conferencing, video conferencing/telephone, and still color images; ISO color image coding standard; and ISO still picture standard are briefly discussed. This presentation is represented by viewgraphs only.

Haskell, Barry↗

Electrical Impedance Tomography Technology: 2013 Center Innovation Fund Final Report

Electrical impedance tomography is a medical noninvasive imaging technology which has advantages over other medical imaging technologies for medically safe long term real time internal imaging monitoring applications in human patients. The technology is much more compact, portable, low power and potentially more low cost compared to other medical image technologies, making it very well suited for medical aerospace and spaceflight applications. EIT technology’s main drawback has been low image resolution, and consequently improving EIT resolution is the primary research goal, as well as increasing imaging speed for real time animation imaging. In a relatively short time the BERL group has brought together design plans, technical resources and has built and tested hardware with the purpose of improving EIT imaging technology. EIT prototype system development plans and system designs have been made to target needed EIT technical improvement in electronic and computer hardware as well as EIT software technology. New hardware design and fabrication resources and technologies have been brought together through resourceful use of existing equipment and software at BERL, and a significant advance has been made in custom electronic hardware prototyping capabilities in collaboration with EFAL, for mutual benefit for both NASA KSC laboratories. BERL has gained significant EIT software capability and tested EIT imaging algorithm code through collaboration with an internationally recognized EIT software development and research forum. A new custom workstation has been developed, built and tested using internal resources, equipment and expertise, that includes a new state-of-the-art massively parallel technology that is commercially available. Custom prototype hardware has been designed and tested, a high priority electronic design, key to improving electronic performance and image quality, has been researched and tested in four designs, with a summary of test results of the selected design illustrated here. The selected design performance exceeds the developed EIT design hardware specifications.

Michael R Lapointe↗

A spatially adaptive spectral re-ordering technique for lossless coding of hyper-spectral images

In this paper, we propose a new approach, applicable to lossless compression of hyper-spectral images, that alleviates some limitations of linear prediction as applied to this problem. According to this approach, an adaptive re-ordering of the spectral components of each pixel is performed prior to prediction and encoding. This re-ordering adaptively exploits, on a pixel-by pixel basis, the presence of inter-band correlations for prediction. Furthermore, the proposed approach takes advantage of spatial correlations, and does not introduce any coding overhead to transmit the order of the spectral bands. This is accomplished by using the assumption that two spatially adjacent pixels are expected to have similar spectral relationships. We thus have a simple technique to exploit spectral and spatial correlations in hyper-spectral data sets, leading to compression performance improvements as compared to our previously reported techniques for lossless compression. We also look at some simple error modeling techniques for further exploiting any structure that remains in the prediction residuals prior to entropy coding.

Memon, Nasir D.↗

Automation of PCXMC and ImPACT for NASA Astronaut Medical Imaging Dose and Risk Tracking

To automate astronaut organ and effective dose calculations from occupational X-ray and computed tomography (CT) examinations incorporating PCXMC and ImPACT tools and to estimate the associated lifetime cancer risk per the National Council on Radiation Protection & Measurements (NCRP) using MATLAB(R). Methods: NASA follows guidance from the NCRP on its operational radiation safety program for astronauts. NCRP Report 142 recommends that astronauts be informed of the cancer risks from reported exposures to ionizing radiation from medical imaging. MATLAB(R) code was written to retrieve exam parameters for medical imaging procedures from a NASA database, calculate associated dose and risk, and return results to the database, using the Microsoft .NET Framework. This code interfaces with the PCXMC executable and emulates the ImPACT Excel spreadsheet to calculate organ doses from X-rays and CTs, respectively, eliminating the need to utilize the PCXMC graphical user interface (except for a few special cases) and the ImPACT spreadsheet. Results: Using MATLAB(R) code to interface with PCXMC and replicate ImPACT dose calculation allowed for rapid evaluation of multiple medical imaging exams. The user inputs the exam parameter data into the database and runs the code. Based on the imaging modality and input parameters, the organ doses are calculated. Output files are created for record, and organ doses, effective dose, and cancer risks associated with each exam are written to the database. Annual and post-flight exposure reports, which are used by the flight surgeon to brief the astronaut, are generated from the database. Conclusions: Automating PCXMC and ImPACT for evaluation of NASA astronaut medical imaging radiation procedures allowed for a traceable and rapid method for tracking projected cancer risks associated with over 12,000 exposures. This code will be used to evaluate future medical radiation exposures, and can easily be modified to accommodate changes to the risk calculation procedure.

Bahadori, Amir↗

Decision Making Under Uncertainty Human Subjects Data - Fire Evacuation Task

This dataset contains de-identified data from human subjects experiments, along with the images and code that were used to run the experiments (as a crowdsourced online study). In this study, participants were shown the probability of a house being in the burn zone of a wildfire. They were asked if they would stay in the house or evacuate in that scenario. The probability information was presented in different ways, including text and maps. The studies tested the impact of different visual cues on the participants' patterns of decisions.

Matzen, Laura E. [Sandia National Laboratories (SN↗

2D Polyhedral Template Matching for Atomic Resolution Microscopy

SAND2024-13879O The 2D Polyhedral Template Matching for Atomic Resolution Microscopy is a suite of functions for analyzing atomic resolution electron microscopy images using the 2D polyhedral template matching (2D-PTM) method. This software analyzes atomic resolution microscopy data from electron microscopic imaging or scanning probe microscopies. The primary application is for identifying different crystal phases, crystal orientations, and defect structures obtained in such atomic resolution images. Written in MATLAB and starting from an atomic resolution image, the code identifies the positions of atomic intensity peaks. It then matches predefined structural templates to the local atomic environments. Outputs include the local structural identification, the template scaling factor and rotation angle, root-mean-squared deviation (RMSD), and centrosymmetry parameter.

Medlin, Douglas↗

Optical system facilitates inspection of printed circuit boards

Optical comparator method determines the quality and registration of surface features of double-sided printed circuit boards. Color-coded superimposed images of both sides of a printed circuit board are presented to view, clearly showing details and registration of the circuitry.

Cridlin, M.↗

Image processing of angiograms: A pilot study

The technology transfer application this report describes is the result of a pilot study of image-processing methods applied to the image enhancement, coding, and analysis of arteriograms. Angiography is a subspecialty of radiology that employs the introduction of media with high X-ray absorption into arteries in order to study vessel pathology as well as to infer disease of the organs supplied by the vessel in question.

Larsen, L. E.↗

M-DAS: System for multispectral data analysis

M-DAS is a ground data processing system designed for analysis of multispectral data. M-DAS operates on multispectral data from LANDSAT, S-192, M2S and other sources in CCT form. Interactive training by operator-investigators using a variable cursor on a color display was used to derive optimum processing coefficients and data on cluster separability. An advanced multivariate normal-maximum likelihood processing algorithm was used to produce output in various formats: color-coded film images, geometrically corrected map overlays, moving displays of scene sections, coverage tabulations and categorized CCTs. The analysis procedure for M-DAS involves three phases: (1) screening and training, (2) analysis of training data to compute performance predictions and processing coefficients, and (3) processing of multichannel input data into categorized results. Typical M-DAS applications involve iteration between each of these phases. A series of photographs of the M-DAS display are used to illustrate M-DAS operation.

Johnson, R. H.↗

A coded aperture gamma ray telescope

A gamma ray telescope is being developed to operate in the energy range 100 keV to 5 MeV, utilizing coded aperture imaging. The design incorporates a mask pattern based on a Uniformly Redundant Array (URA), which has been shown to have ideal imaging characteristics. A mask-anti-mask procedure is used to eliminate the effects of any possible systematic variations in detector background rates. The detector array is composed of 35 elements of the high-Z material Bismuth Germanate (BGO). Results of laboratory testing of the imaging properties will be presented. A southern hemisphere balloon flight is planned for 1982 with the goal of observing the 0.511 MeV radiation from the Galactic Center. Computer calculations show that a point source of this radiation can be located to within + or - 1 deg.

Mcconnell, M. L.↗