Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Soft X-ray tomography reveals variations in B. subtilis biofilm structure upon tasA deletion

Bacterial biofilms are complex cell communities within a self-produced extracellular matrix, crucial in various fields but challenging to analyze in 3D. We developed a "biofilm-in-capillary" growth method compatible with full-rotation soft X-ray tomography, enabling high-resolution 3D imaging of bacterial cells and their matrix during biofilm formation. This approach offers 50 nm isotropic spatial resolution, rapid imaging, and quantitative native analysis of biofilm structure. Using Bacillus subtilis biofilms, we detected coherent alignment and chaining of wild-type cells towards the oxygen-rich capillary tip. In contrast, the ΔtasA genetic knock-out showed a loss of cellular orientation and changes in the extracellular matrix. Adding TasA protein to the ΔtasA strain restored matrix density and led to cell assembly compaction, but without the chaining observed in wild-type biofilms. This scalable and transferable approach opens new avenues for examining biofilm structure and function across various species, including mixed biofilms, and response to genetic and environmental factors.

59 BASIC BIOLOGICAL SCIENCES↗

Illuminating the Night: A Survey of Super-Resolution Methods for Nighttime Light Images

Nighttime Light (NTL) images provide critical insights into urbanization, disaster response, and energy consumption. The VIIRS Day/Night Band (DNB) sensor offers high-quality NTL imagery with daily revisit rates, but the available spatial resolution hinders fine-grained accurate analysis. Super-resolution techniques aim to increase the resolution of NTL images, enabling more detailed assessments of infrastructure, light pollution, economic activity, and power outages. However, existing state-of-the-art super-resolution methods designed for natural images struggle with the unique characteristics of NTL data. This work provides a comprehensive review of super-resolution methods across multiple image modalities, evaluates their effectiveness on VIIRS DNB data, and proposes a multi-modal super-resolution approach tailored to NTL imagery. The proposed approach integrates VIIRS DNB data with road networks and land use information to improve reconstruction accuracy and spatial detail. Code is available for this project at https://code.ornl.gov/viirs-sr/sr-demos.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Illuminating the Night: A Survey of Super-Resolution Methods for Nighttime Light Images

Nighttime Light (NTL) images provide critical insights into urbanization, disaster response, and energy consumption. The VIIRS Day/Night Band (DNB) sensor offers high-quality NTL imagery with daily revisit rates, but the available spatial resolution hinders fine-grained accurate analysis. Super-resolution techniques aim to increase the resolution of NTL images, enabling more detailed assessments of infrastructure, light pollution, economic activity, and power outages. However, existing state-of-the-art super-resolution methods designed for natural images struggle with the unique characteristics of NTL data. This work provides a comprehensive review of super-resolution methods across multiple image modalities, evaluates their effectiveness on VI-IRS DNB data, and proposes a multi-modal super-resolution approach tailored to NTL imagery. The proposed approach integrates VIIRS DNB data with road networks and land use information to improve reconstruction accuracy and spatial detail. Code is available for this project athttps://code.ornl.gov/viirs-sr/sr-demos.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Interior soft x-ray tomography with sparse global sampling

To investigate the feasibility of interior imaging reconstruction in soft X-ray tomography for higher-resolution cellular imaging, including whole-cell imaging, we develop an alignment and reconstruction algorithm that combines a small number of sparse whole-cell images with a high-resolution local interior scan. Based on numerical simulations, we demonstrate that combined reconstructions mitigate the depth-of-field limitation in high-resolution scans, enable radiation dose optimization, and yield quantitative X-ray absorption values with sparse sampling. We further validate our numerical approach using experimental data from two different cell types and show that the combined reconstruction reliably provides high spatial resolution within an interior region of interest of a whole cell. The resulting sparse reconstruction framework offers robust, faithful visualization of cellular organelles in soft X-ray tomography. This mesoscale imaging strategy allows one to ‘scout’ and zoom into selected subcellular volumes of interest, enabling increased spatial resolution without sacrificing larger-volume imaging and providing information on the relative positions of all organelles within a cell.

3D imaging↗

Global Multimodal Dataset for Nighttime Light Super-Resolution

The dataset is a collection of spatially and temporally registered high-resolution and low-resolution nighttime light (NTL) images, high-resolution land-use binary masks, and high-resolution road density images from around the world. The NTL images are sourced from the NASA Black Marble product VNP46A2 and the LuoJia1-01 satellite. The land-use binary masks are derived from Google's and the World Resources Institute's DynamicWorld dataset, and the road density images are sourced from OpenStreetMap.

Nighttime lights↗

Advances in Image-Domain Multi-Resolution and Super-Resolution Algorithms for Industrial X-Ray Computed Tomography: A Literature Survey and New Insights

Industrial X-ray Computed Tomography (XCT) is a nondestructive method for inspection and character ization of materials and parts. XCT captures images of a part from various angles, and these images are then used to construct Three-Dimensional (3D) representations of that part. This method enables assessing the quality of the parts, identifying defects and understanding their physical properties without damaging them.

36 MATERIALS SCIENCE↗

Evaluating Machine Learning-Based MRI Reconstruction Using Digital Image Quality Phantoms

Quantitative and objective evaluation tools are essential for assessing the performance of machine learning (ML)-based magnetic resonance imaging (MRI) reconstruction methods. However, the commonly used fidelity metrics, such as mean squared error (MSE), structural similarity (SSIM), and peak signal-to-noise ratio (PSNR), often fail to capture fundamental and clinically relevant MR image quality aspects. To address this, we propose evaluation of ML-based MRI reconstruction using digital image quality phantoms and automated evaluation methods. Our phantoms are based upon the American College of Radiology (ACR) large physical phantom but created in k-space to simulate their MR images, and they can vary in object size, signal-to-noise ratio, resolution, and image contrast. Our evaluation pipeline incorporates evaluation metrics of geometric accuracy, intensity uniformity, percentage ghosting, sharpness, signal-to-noise ratio, resolution, and low-contrast detectability. We demonstrate the utility of our proposed pipeline by assessing an example ML-based reconstruction model across various training and testing scenarios. The performance results indicate that training data acquired with a lower undersampling factor and coils of larger anatomical coverage yield a better performing model. The comprehensive and standardized pipeline introduced in this study can help to facilitate a better understanding of the performance and guide future development and advancement of ML-based reconstruction algorithms.

47 OTHER INSTRUMENTATION↗

2D Polyhedral Template Matching for Atomic Resolution Microscopy

SAND2024-13879O The 2D Polyhedral Template Matching for Atomic Resolution Microscopy is a suite of functions for analyzing atomic resolution electron microscopy images using the 2D polyhedral template matching (2D-PTM) method. This software analyzes atomic resolution microscopy data from electron microscopic imaging or scanning probe microscopies. The primary application is for identifying different crystal phases, crystal orientations, and defect structures obtained in such atomic resolution images. Written in MATLAB and starting from an atomic resolution image, the code identifies the positions of atomic intensity peaks. It then matches predefined structural templates to the local atomic environments. Outputs include the local structural identification, the template scaling factor and rotation angle, root-mean-squared deviation (RMSD), and centrosymmetry parameter.

Medlin, Douglas↗

High-resolution Giant Metrewave Radio Telescope H I 21 cm Imaging of the Host Galaxy of FRB 20250316A

We report Giant Metrewave Radio Telescope (GMRT) H I 21 cm imaging of NGC 4141, the host galaxy of FRB 20250316A at z = 0.0063. Our GMRT H I 21 cm images have spatial resolutions, at z ≈ 0.0063, of ≈0.48–8.0 kpc, and provide evidence for (i) a companion galaxy, LEDA 2582852, to the southwest, (ii) a nearby (27 kpc distant) H i cloud to the southwest, (iii) disturbances in the H I distributions of both NGC 4141 and LEDA 2582852, and (iv) high H I column densities in the southwestern outskirts of NGC 4141. A Sloan Digital Sky Survey spectrum yields a low metallicity and a high star formation rate (SFR) surface density in the southwestern disk of NGC 4141, and an Hα-based SFR estimate that is significantly higher than that at the same location from the Galaxy Evolution Explorer near-ultraviolet image, indicating a recent burst of star formation. The total SFR of NGC 4141 is also found to be higher via the Hα line than from the 1.4 GHz radio continuum. The above evidence indicates that NGC 4141 has recently (within the last ≈3 Myr) acquired metal-poor gas, via either a merger or accretion, that resulted in the southwestern starburst and that may also have triggered large-scale star-formation activity in NGC 4141, resulting in the formation of the stellar progenitor of FRB 20250316A and the other transients. Our highest-resolution (480 pc) GMRT H I 21 cm image finds no H I 21 cm emission from the location of FRB 20250316A or the nearby star-forming region, suggesting that most of the H I here has been either ionized or converted into the molecular phase. Our nondetection of continuum emission at the location of FRB 20250316A yields the 3σ upper limit νL 1.38 GHz < 4.4 × 10 34 erg s −1 on the 1.38 GHz radio luminosity of a putative persistent radio source associated with FRB 20250316A, one of the strongest constraints on the radio luminosity of such an associated persistent radio source.

Kaur, Balpreet [Pune University (India)] (ORCID:00↗

High-Speed and High-Quality Field Welding Repair Based on Advanced Non-Destructive Evaluation and Numerical Modeling

Creep strength-enhanced ferritic (CSEF) steels such as Grade 91 (9Cr-1Mo-V) and Grade 92 (Fe-9Cr-2W-0.5Mo) steels are widely used in the fossil-fuel-fired and nuclear power plants. The weld integrity of these steels is crucial for power plants' safe and reliable operations. Due to harsh service conditions, the steel weld can become susceptible to environmental degradation. Field welding repair is used to restore the degraded weld’s performance where a controlled temper-bead welding technique is commonly used to temper the freshly formed martensite during welding. However, knowledge of weld repairability is limited and experimental trial and error optimization to achieve desired microstructure and joint properties is expensive and time-consuming. Many existing computational models, e.g., finite element models, are limited to solving heat conduction equation and ignoring convective heat transfer due to molten metal flow. These models can result in over-prediction of peak temperatures of weld pool and heat-affected zone (HAZ), which in turn can affect the accuracy of tempering prediction. Moreover, these finite element models require an input of the deposit profiles in advance and thus limits the usability of these models. Here, a molten pool-based, multi-pass multi-layer model has been developed based on computational fluid dynamics (CFD) approach with the Volume of Fluid (VOF) method. The model calculates the bead formation, thereby eliminating the need for pre-determined bead profiles required by finite element models. For computational efficiency, a coordinate system attached to the moving heat source is utilized. A subroutine is developed to convert the temperature profiles in the reference frame stationary to the heat source to that stationary to the workpiece. The converted thermal cycles are then imported into a microstructure model to compute the tempering kinetics and resultant hardness using a Johnson-Mehl-Avrami-Kolmogorov (JMAK), and modified Grange-Baughman parameter. The modeling approach is first developed and validated on single- and multi-pass deposition of stainless steel filler metal onto a SA-533 high strength steel substrate. The models are then applied to a multi-pass V-groove repair weld of Grade 91 steel plate as well as directed energy deposition of Grade 92 steel. Non-destructive characterization of microstructures was performed on Grade 91 and 92 steel welds. Two welding processes, cold metal transfer (CMT) and flux-cored arc welding (FCAW), were investigated for the Grade 91 steel weld samples. For the Grade 92 weld samples, three different heat inputs (low, medium, and high) of gas tungsten arc welding (GTAW) were utilized to replicate traditional field welding processes. The non-destructive evaluation (NDE) method used for this research was immersion ultrasonic testing (UT) using a micro-resolution ultrasonic imaging methodology specifically designed to operate in the through-transmission configuration operating at 20 MHz of frequency. The system used a focused ultrasonic beam spot size diameter between 250-300 μm, and a 6 μm laser vibrometer spot size for detection, to produce highly defined images with longitudinal and mode-converted shear waves. From the micro-resolution ultrasonic C-scan images, three microstructural regions, i.e., weld metal (WM), HAZ, and base metal (BM), were clearly identifiable. Various levels of ultrasonic amplitudes distributed over the three regions were correlated with electron beam backscattered diffraction (EBSD) images using grain size, grain boundaries, and dislocation densities. The results showed that areas with relatively higher ultrasonic amplitude levels were associated with smaller grains and higher dislocation densities, while areas with lower amplitude levels were associated with larger grains and lower dislocation densities. In addition, ultrasonic velocity data obtained across the three different weld microstructural regions of Grade 91 test samples were correlated with optical metallographic images and hardness measurements. The results showed distinctive decreases in ultrasonic velocity and hardness over the HAZ region, where weld failures often occur during service.

36 MATERIALS SCIENCE↗

LITE-SM: A Light Sheet Illuminator Compatible with Super Resolution and Single Molecule Imaging

The LITE-SM (hereinafter referred to as the Tilt-SM) is a light sheet illumination system purpose-built for single molecule (SM) imaging. SM imaging is a fluorescence imaging technique where individual molecules can be tracked in living cells/tissues in real time allowing for unprecedented insights into the intracellular dynamics of these molecules. The innovative all-mirror optical design greatly reduces/eliminates the aberrations that plague lens-based designs. This iteration of the Tilt-SM has significantly better optical performance then its predecessor with over 10x increase in optical power at the sample, allowing for the use of much smaller and more cost-effective lasers then the original Phase 1 system. Excellent STORM imaging as well as SM tracking has been achieved, satisfying the key objectives of this study.

59 BASIC BIOLOGICAL SCIENCES↗

28nm front end ASIC and 12” LGADs for 3D integration

The 3DIntSenS Collaboration—a joint effort between SLAC, Fermilab, and LLNL—is developing enabling technologies for next-generation radiation imaging detectors that combine ultra-fine spatial resolution (≈10 μm) with precision timing (<20 ps), while maintaining low power <1 W/cm2 and high data throughput. The approach leverages 3D integration between advanced CMOS readout ASICs and finely pixelated LGAD sensors to achieve the performance and scalability required for large-area, high-rate applications. High-granularity, precision-timing detectors are essential for scientific advances in HEP, NP, BES, and FES, but widespread adoption is limited by the cost and complexity of 3D integration. To close this gap, the collaboration is developing LGAD sensors compatible with 12-inch commercial CMOS processes, enabling cost-effective integration with high-performance ASICs under development. We present the design and results from a 28 nm CMOS ASIC prototype, including a low-jitter front end, and in-pixel TDC demonstrating sub-10 ps timing resolution. We also report on the co-design and characterization of reticle-scale LGAD sensors with 50 μm and 100 μm pixels and introduce the next 10k-pixel ASIC designed for full 3D integration. These advances represent a critical step toward scalable, high-resolution radiation imaging systems for future scientific instrumentation.

England, Troy [Fermilab] (ORCID:0000000154405255)↗

Image Alignment and Flat-Field Correction of Film and Computed Radiography Images on the LLNL Flash Testbed

Computed radiography (CR) imaging plates and film are used in HEAF firing tanks and in the NDE group. The imaging plates allow for the creation of high-resolution digital images with flash X-ray (FXR). A typical treatment of flash X-ray radiographs is flat-field correction, where the image from an experiment is normalized by a “flat-field” or “bright-field” image. This flat-field image is taken in an identical configuration to the experimental image, but without the object or experiment in the field of view (FOV). This treatment reduces spatial effects from the FXR spot size and detector misalignment, as each pixel value in the corrected image represents a ratio of collected radiation with the object in FOV to the collected radiation without the object in FOV. One challenge in the creation of a corrected image is the misalignment of the CR plate or film pack between capturing the flat-field image and the experimental image. Fiducial structures can remedy this issue. Small (3.18mm) stainless steel ball bearings serve as good fiducial structures due to their small size and high radiographic contrast. Spheres are view-agnostic geometry, always presenting a circular cross section no matter the orientation. This process was developed for images from the flash X-ray testbed. The flash testbed was used to compare the X-ray transmission at different thicknesses of aluminum and copper step wedges. Each step wedge section is a rectangular shape, so evaluation is made much simpler if the rectangles are not rotated with respect to the image. This alignment process aligns the object and flat-field images together and leaves the rectangles of each step aligned with the image.

36 MATERIALS SCIENCE↗

Label-free nanoscopy of cell metabolism by ultrasensitive reweighted visible stimulated Raman scattering

Nanoscopic imaging of cell metabolism is hindered by the incompatibility of small metabolites with fluorescent dyes and the limited resolution of imaging mass spectrometry. We present ultrasensitive reweighted visible stimulated Raman scattering (URV-SRS), a label-free vibrational nanoscopy technique that enables multiplexed detection of metabolic nanostructures within cells. We developed an extensively chirped spectral focusing visible SRS microscope that achieves a detection limit of 4,000 molecules and introduced a self-supervised learning-based denoiser to robustly suppress non-independent SRS noise by over 7.2 dB. The instrumentation-based signal enhancement and computation-based noise suppression synergistically improved the detection sensitivity by 50 times over near-infrared SRS. Leveraging this enhanced sensitivity, we further pushed the resolution to nanoscopic levels by introducing Fourier reweighting to amplify sub-100 nm spatial frequencies previously overwhelmed by noise. Validated by Fourier ring correlation, URV-SRS achieves a lateral resolution of 86 nm in cellular imaging. Here, we applied URV-SRS to elucidate the reprogramming of metabolic nanostructures associated with virus replication in Vero E6 host cells and to compositionally delineate subcellular fatty acid synthesis in engineered Escherichia coli, demonstrating its capability towards nanoscopic spatial metabolomics.

59 BASIC BIOLOGICAL SCIENCES↗

Tracking Spatiotemporal Electric Potential in Batteries Using High-Resolution Operando X‑ray Transmission Imaging

The formation of significant concentration gradients across electrolytes in batteries affects the rate at which electrochemical reactions occur. In this work, we use high-resolution operando X-ray transmission imaging to capture spatiotemporal salt concentration profiles c(x,t) in a symmetric cell comprising a polymer electrolyte sandwiched between two lithium–indium alloy electrodes during a constant-current experiment followed by open-circuit relaxation. The decay of open-circuit potential is related to the concentration dependence of the potential across concentration cells, U. We show how operando c(x,t) data can be used to calculate the spatiotemporal electric potential “inside” the polarized electrolyte. We track the spatial- and time-dependent cell potential during the constant-current step and distinguish its two contributions: a concentration overpotential governed by U. and an ohmic contribution governed by ionic conductivity. Over most of the time window, the concentration overpotential dominates. At steady state, it is a factor of 7 larger than the ohmic contribution. Such findings indicate that efforts to design new polymer electrolytes should focus on minimizing concentration gradients.

Electrical conductivity↗

Heliostat optical error inspection with polarimetric imaging drone

On a Concentrated Solar Power (CSP) field, optical errors have significant impacts on the collection efficiency of heliostats. Fast, cost-effective, labor-efficient, and non-intrusive autonomous field inspection remains a challenge. Approaches using imaging drone, i.e., Unmanned Aerial Vehicle (UAV) system integrated with high resolution visible imaging sensors, have been developed to address these challenges; however, these approaches are often limited by insufficient imaging contrast. Here, in this study, we report a polarimetry-based method with a polarization imaging system integrated on UAV to enhance imaging contrast for in-situ detection of heliostat mirrors without interrupting field operation. We developed an optical model for skylight polarization pattern to simulate the polarization images of heliostat mirrors and obtained optimized waypoints for polarimetric imaging drone flight path to capture images with enhanced contrast. The polarimetric imaging-based method improved the success rate of edge detections in scenarios which were challenging for mirror edge detection with conventional imaging sensors. We have performed field tests to achieve significantly enhanced heliostat edge detection success rate and investigate the feasibility of integrating polarimetric imaging method with existing imaging-based heliostat inspection methods, i.e., Polarimetric Imaging Heliostat Inspection Method (PIHIM). Our preliminary field test results suggest that the PIHIM hold the promise to enable sufficient imaging contrast for real-time autonomous imaging and detection of heliostat field, thus suitable for non-interruptive fast CSP field inspection during its operation.

CSP Field↗

Fourier-based three-dimensional multistage transformer for aberration correction in multicellular specimens

High-resolution tissue imaging is often compromised by sample-induced optical aberrations that degrade resolution and contrast. Although wavefront sensor-based adaptive optics (AO) can measure these aberrations, such hardware solutions are typically complex, expensive to implement and slow when serially mapping spatially varying aberrations across large fields of view. Here we introduce AOViFT (adaptive optical vision Fourier transformer)—a machine learning-based aberration sensing framework built around a three-dimensional multistage vision transformer that operates on Fourier domain embeddings. AOViFT infers aberrations and restores diffraction-limited performance in puncta-labeled specimens with substantially reduced computational cost, training time and memory footprint compared to conventional architectures or real-space networks. We validated AOViFT on live gene-edited zebrafish embryos, demonstrating its ability to correct spatially varying aberrations using either a deformable mirror or postacquisition deconvolution. By eliminating the need for the guide star and wavefront sensing hardware and simplifying the experimental workflow, AOViFT lowers technical barriers for high-resolution volumetric microscopy across diverse biological samples.

Alshaabi, Thayer [Howard Hughes Medical Institute,↗