Search NASA⌕ Search

SEARCH · Search NASA

Results for “Immobilization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Microfluidic Devices for Studying Biomolecular Interactions

Microfluidic devices for monitoring biomolecular interactions have been invented. These devices are basically highly miniaturized liquid-chromatography columns. They are intended to be prototypes of miniature analytical devices of the laboratory on a chip type that could be fabricated rapidly and inexpensively and that, because of their small sizes, would yield analytical results from very small amounts of expensive analytes (typically, proteins). Other advantages to be gained by this scaling down of liquid-chromatography columns may include increases in resolution and speed, decreases in the consumption of reagents, and the possibility of performing multiple simultaneous and highly integrated analyses by use of multiple devices of this type, each possibly containing multiple parallel analytical microchannels. The principle of operation is the same as that of a macroscopic liquid-chromatography column: The column is a channel packed with particles, upon which are immobilized molecules of the protein of interest (or one of the proteins of interest if there are more than one). Starting at a known time, a solution or suspension containing molecules of the protein or other substance of interest is pumped into the channel at its inlet. The liquid emerging from the outlet of the channel is monitored to detect the molecules of the dissolved or suspended substance(s). The time that it takes these molecules to flow from the inlet to the outlet is a measure of the degree of interaction between the immobilized and the dissolved or suspended molecules. Depending on the precise natures of the molecules, this measure can be used for diverse purposes: examples include screening for solution conditions that favor crystallization of proteins, screening for interactions between drugs and proteins, and determining the functions of biomolecules.

Wilson, Wilbur W.↗

Label-Free Detection of Cardiac Troponin-I Using Carbon Nanofiber Based Nanoelectrode Arrays

A sensor platform based on vertically aligned carbon nanofibers (CNFs) has been developed. Their inherent nanometer scale, high conductivity, wide potential window, good biocompatibility and well-defined surface chemistry make them ideal candidates as biosensor electrodes. A carbon nanofiber (CNF) multiplexed array has been fabricated with 9 sensing pads, each containing 40,000 carbon nanofibers as nanoelectrodes. Here, we report the use of vertically aligned CNF nanoelectrodes for the detection of cardiac Troponin-I for the early diagnosis of myocardial infarction. Antibody, antitroponin, probe immobilization and subsequent binding to human cardiac troponin-I were characterized using electrochemical impedance spectroscopy and cyclic voltammetry techniques. Each step of the modification process resulted in changes in electrical capacitance or resistance to charge transfer due to the changes at the electrode surface upon antibody immobilization and binding to the specific antigen. This sensor demonstrates high sensitivity, down to 0.2 ng/mL, and good selectivity making this platform a good candidate for early stage diagnosis of myocardial infarction.

cardiac output↗

X-Ray Computed Tomography of Apollo Drive Tube 73001 as Part of the Apollo Next Generation Sample Analysis Program

Introduction: Starting in 2019, the Apollo Next Generation Sample Analysis (ANGSA) Program has enabled consortium studies of specially curated Apollo samples that were previously unstudied (or under studied). This program was intended as a participating scientist program for these Apollo samples, as well as a preparation for upcoming lunar sample return missions (e.g., Artemis). The work began with studies of unsealed core tube 73002 [1,2] that is the upper ~35 cm of an Apollo 17 double drive tube (~70 cm total depth) collected on the landslide deposit near Lara Crater at Station 3 in the Taurus Littrow Valley. More recently the program extended to the study of a variety of frozen Apollo 17 samples [3], as well as the gas extraction [4] and dissection [5] of 73001, the lower half of the station 3 double drive tube. Sample 73001 was sealed under vacuum on the Moon in a Core Sample Vacuum Container (CSVC). In this abstract we will examine the role of X-ray Computed Tomography (XCT) during the preliminary examination process for sealed core 73001, including: (1) engineering scans to aid in understanding the gas extraction process, (2) whole-core scanning prior to opening to inform extrusion and dissection work, and (3) individual particle scanning to characterize rock fragment lithologies for follow on studies. Methodology: Sample 73001 is a 33 cm long, 4 cm diameter regolith sample collected inside a lunar drive tube (~1 mm aluminum walls). That drive tube was sealed inside a 0.5 mm thick stainless steel (SS) CSVC. XCT scans for engineering purposes were done on the Nikon XTH 320 system at Johnson Space Center using the 225 kV multi-metal reflection source at 215 kV, 179 A, and a 38.49 m voxel size. Individual >4 mm particles separated from the core during processing (then triply sealed in Teflon bags) were also scanned at JSC using the 180 kV source at 90 kV, 33 A, and a 2.98 – 10.65 m voxel size. Whole-core scans were done at the University of Texas High-Resolution X-ray Computed Tomography Facility (UTCT) on the 225 kV reflection source on the North Star Imaging cabinet XCT system. These scans included: (1) a series of 9 overlapping super-resolution scans each covering a ~4 cm length of the tube at 190 kV, 180 µA, and a 12.9 µm voxel size and (2) a lower resolution continuous helical scan of the entire core at 190 kV, 180 µA, and a 51.8 µm voxel size. Progress and Results: Before piercing and extracting the gas from sample 73001, an XCT scan of the bottom portion of the CSVC was used to confirm the location of the Teflon cap on the inner drive tube and whether there was an “air” gap between the Teflon cap and the CSVC. This was to ensure the Teflon cap (which immobilized the soil inside the drive tube) was not accidentally pierced during gas extraction. Similarly, after piercing, the bottom and top portions of the CSVC were scanned in order to capture engineering knowledge about the results of the piercing process, as well as the metal knife edge vacuum seal (SS into an In-Ag alloy). Both scans will provide constraints on future work of this type, both for the design of tools used on the lunar surface during Artemis, as well as how we open future samples of this type. An unexpected finding from these engineering scans was that the device in the drive tube that immobilizes the regolith (the keeper) was not seated in the tube properly. This meant that (1) the drive tube could not be removed from the CSVC for the trip to UTCT, and (2) the procedure for opening and extruding the drive tube had to be modified. Had either of these things not been known prior to opening the CSVC, it could have led to an inability to XCT scan the whole core at high resolution and/or potential disruption of the core stratigraphy during extrusion. At UTCT, the entire length of the core was scanned at high resolution (12.9 microns per voxel). This scan serves multiple purposes: (1) A lower resolution (and uncorrected) version of these scans stitched together was used to help inform the processors of potential pitfalls during extrusion and dissection (voids, angular fragments at the edges of the sample, etc.); and (2) the full resolution corrected data will serve as the permanent in situ record of the stratigraphy of the sample and will enable future researchers to perform a variety of analyses. All 121 >4 mm particles separated during dissection pass 1 of sample 73001 have been individually scanned. These scans clearly show the lithology of each particle while keeping the particles in pristine condition (they are individually triply bagged in Teflon within our N2 purged processing cabinets). Because of the dust adhering to particle exteriors, it would otherwise be impossible to determine lithologies in a non-contaminating way. Thus far the types of lithologies seen in sample 73001 (e.g., regolith breccias, impact-melt breccias, agglutinates, and bas-alts) are similar to those previously identified in sample 73002 [2]. By the time of the meeting, all particles from all 3 dissection passes will have been scanned and statistics on the different lithologies in 73001 compiled. References: [1] Shearer et al. (2020) 51st LPSC, abstract 1181. [2] Zeigler et al. (2020) 51st LPSC, abstract 3023. [3] Kent et al. (2022) This Volume. [4] McDonald et al. (2022) European Lunar Symposium. [5] Gross et al (2022) This volume.

Moon↗

Influence of performance on gene expression in skeletal muscle: effects of forced inactivity

Joint immobilization and hindlimb suspension are used to examine muscle protein expression and mRNA quantities in rats. A decrease in protein synthesis was not associated with alteration in alpha-actin mRNA, cytochrome c mRNA, or beta-myosin heavy chain mRNA early in treatment. Percentage declines after seven days are compared with early treatment quantities to determine acute and chronic response to muscular atrophy.

Non-NASA Center↗

Cell-cycle research with synchronous cultures: an evaluation

The baby-machine system, which produces new-born Escherichia coli cells from cultures immobilized on a membrane, was developed many years ago in an attempt to attain optimal synchrony with minimal disturbance of steady-state growth. In the present article, we put forward a model to describe the behaviour of cells produced by this method, and provide quantitative evaluation of the parameters involved, at each of four different growth rates. Considering the high level of selection achievable with this technique and the natural dispersion in interdivision times, we believe that the output of the baby machine is probably close to optimal in terms of both quality and persistence of synchrony. We show that considerable information on events in the cell cycle can be obtained from populations with age distributions very much broader than those achieved with the baby machine and differing only modestly from steady state. The data presented here, together with the long and fruitful history of findings employing the baby-machine technique, suggest that minimisation of stress on cells is the single most important factor for successful cell-cycle analysis.

Non-NASA Center↗

Progress in Development of Methods in Bone Densitometry

The effects of weightlessness and decreased activity on the astronaut's musculoskeletal system during prolonged space flight, missions are of concern to NASA. This problem was anticipated from the knowledge that human subjects lose significant quantities of calcium from the skeleton during periods of bedrest, immobilization, and water immersion. An accurate method of measurement of the changes in mineral content of the skeleton is required not only in the space program but also in the biological, medical, and dental fields for mineral metabolism studies and for studying various pathological conditions of the skeleton and teeth. This method is a difficult one requiring the coordinated efforts of physiologists, biophysicists, radiologists, and clinicians. The densitometry methods reported in this conference which have been used or are being developed include X-ray, beta excited X-rays, radioisotopes, sonic vibration, and neutron activation analysis Studies in the Gemini, Biosatellite, and Apollo flights use the X-ray bone densitometry method which requires making X-rays before and after the flights. An in-flight method of bone densitometry would be valuable, and use of radioisotope sources has been suggested. Many advances in bone densitometry have been made in the last five years, and the urgency of the requirement makes this working conference timely and valuable. In such a rapidly developing field with investigators working independently in a variety of scientific disciplines, a working conference is of great value in exchanging information and ideas, critically evaluating approaches and methods, and pointing out new research pathways.

DENSITOMETER↗

Inflatable stretcher to transport patients

Inflatable plastic bag inside strong, inflexible outer bag facilitates emergency transport of seriously burned or disabled patients. When the bag is inflated the patient is completely immobilized and cushioned from external shock. Air for breathing, temperature controls and communications may be provided by appropriate plug-in connections.

Clark, C. C.↗

Absolute focus lock for microscopes

Mechanism absolutely immobilizes microscope stage at a preset focus, preserving focus indefinitely. The lock is a second-class lever consisting of a straight body having a fulcrum with a cylindrical bearing surface at one end and a thumbscrew at the other end.

Cone, C. D., Jr.↗

Stretcher Patent

Stretcher with rigid head and neck support with capability of supporting immobilized person in vertical position for removal from vehicle hatch to exterior also useful as splint stretcher

Lothschuetz, F. X.↗

Bone demineralization

Crew members of the Gemini 4, Gemini 5, and Gemini 7 missions were compared regarding skeletal changes in three major anatomic sites with respect to changes in skeletal density during space flight. Bone-mass changes have been found for the command pilot and the pilot of each mission in the conventional os calcis section, in the combined sections covering 60 percent of the os calcis, and in hand phalanges 5-2 and 4-2. Comparison of radiographically determined losses in X-ray absorbence with X-ray absorbence losses in healthy young men subjected to bedrest immobilization for the same length of time showed that losses for the crewmembers exceeded losses for the bedrest subjects in all cases; this was an indication that restriction of body movement did not represent the only factor involved.

Mack, P. B.↗

Effect of radiometric errors on accuracy of temperature-profile measurement by spectral scanning using absorption-emission pyrometry

The spectral-scanning method may be used to determine the temperature profile of a jet- or rocket-engine exhaust stream by measurements of gas radiation and transmittance, at two or more wavelengths. A single, fixed line of sight is used, using immobile radiators outside of the gas stream, and there is no interference with the flow. At least two sets of measurements are made, each set consisting of the conventional three radiometric measurements of absorption-emission pyrometry, but each set is taken over a different spectral interval that gives different weight to the radiation from a different portion of the optical path. Thereby, discrimination is obtained with respect to location along the path. A given radiometric error causes an error in computed temperatures. The ratio between temperature error and radiometric error depends on profile shape, path length, temperature level, and strength of line absorption, and the absorption coefficient and its temperature dependency. These influence the choice of wavelengths, for any given gas. Conditions for minimum temperature error are derived. Numerical results are presented for a two-wavelength measurement on a family of profiles that may be expected in a practical case of hydrogen-oxygen combustion. Under favorable conditions, the fractional error in temperature approximates the fractional error in radiant-flux measurement.

Buchele, D. R.↗

Experimental investigation on the origin of the genetic code.

A simple model of interacting complex systems of species is tested to assess the binding behavior of monomeric nucleic acid and protein components during evolution. Nine representative amino acids are immobilized by the formation of an amide linkage on a prepared chromatographic support. Selective binding of ribonucleoside 5-phosphates in these amino acids is achieved under standardized conditions, and a site-binding model is derived to characterize the binding. It is shown that the binding behavior of the reactants during nucleic acid-protein interactions depends on the nature of the base and the amino acid. The results of the study are assessed as useful for the interpretation of more complex nucleic acid-protein systems and of their role in the evolution of the cell.

Saxinger, C.↗

Subminiature micropower digital recorder

High-density digital data, collected periodically or randomly from multiplicity of sensors, are recorded by subminiature recorder. Magnetic recording head is energized with suitable pulsatile signals to reverse polarization on magnetically-sensitive tape while tape is immobilized at recording head. Prior to next recording, set tape so new area of tape is at recording head.

Goodman, R. M.↗