Search NASA⌕ Search

SEARCH · Search NASA

Results for “Indoor simulators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The impact of simplified window and exhaust fan assumptions on indoor air quality in multifamily buildings

In residential buildings, the indoor air quality can be significantly affected by ventilation measures initiated by occupants, including the operation of windows and in-unit exhaust fans in kitchens and bathrooms. Many simulations simplify these factors by disregarding window opening behaviors and using fixed schedules for exhaust fan operation across all residential units. To estimate the impact of these simplifications in the U.S. context, this study used coupled CONTAM and EnergyPlus models to simulate airflow and contaminant transport in multifamily buildings. The coupled models parametrically varied climate zone, building airtightness, and mechanical ventilation system types. The study conducted a sensitivity analysis on two key occupant behaviors: (1) operating kitchen and bathroom exhausts on different schedules in individual dwelling units, and (2) scheduling open windows on ground and top floors. The simplified assumptions (i.e. uniform in-unit exhaust fan operation and window operation) had a minimal impact on inter-unit air flow and contaminant transport simulations across a broad range of building air leakage and mechanical ventilation system types. These findings suggest that for buildings with tight construction it is reasonable for most modelling and simulation efforts to ignore the effects of non-uniform exhaust fan operation and window opening.

Occupant behavior↗

Vibration Penalty Estimates for Indoor Annoyance Caused by Sonic Boom

Commercial supersonic flight is currently forbidden over land because sonic booms have historically caused unacceptable annoyance levels in overflown communities. NASA is providing data and expertise to noise regulators as they consider relaxing the ban for future quiet supersonic aircraft. One key objective is a predictive model for indoor annoyance based on factors such as noise and indoor vibration levels. The current study quantified the increment in indoor sonic boom annoyance when sonic booms can be felt directly through structural vibrations in addition to being heard. A shaker mounted below each chair in the sonic boom simulator emulated vibrations transmitting through the structure to that chair. The vibration amplitudes were determined from numeric models of a large range of residential structures excited by the same sonic boom waveforms used in the experiment. The analysis yielded vibration penalties, which are the increments in sound level needed to increase annoyance as much as the vibration does. For sonic booms at acoustic levels from 75 to 84 dB Perceived Level, vibration signals with lower amplitudes (+1 sigma) yielded penalties from 0 to 5 dB, and vibration signals with higher amplitudes (+3 sigma) yielded penalties from 6 to 10 dB.

Rathsam, Jonathan↗

High-performance windows improve thermal survivability of occupants during cold snaps

Exposure to low indoor air temperature is a major contributor to temperature-related mortality during extreme cold events, especially when power outages disrupt operation of space heating systems. This study explores the impact of high-performance windows on the thermal resilience of residential buildings during extreme cold weather and grid power outages, as well as their long-term benefits through energy efficiency and reduced risk of property damage. Building performance simulations were conducted for reference residential buildings in three construction vintages and two major U.S. cities located in cold climate zones, considering two types of extreme cold events: short and severe, and long and milder. Our research found that even houses compliant with current energy codes struggle to maintain safe indoor temperatures for more than a few hours during power outages, necessitating rapid evacuations. High-performance windows can extend the thermal survivability time by up to 3.8 days within a 7-day cold snap and significantly reduce risk of bursting frozen water pipes, depending on the building’s insulation and infiltration level, cold event severity, and occupant vulnerability. This extended thermal safety time is crucial in scenarios where reduced mobility complicates emergency responses in senior housing. In addition to boosting thermal resilience, upgrading older homes with high-performance windows can reduce heating energy consumption by over 18% and cooling energy by 15%. Our findings highlight the need to incorporate thermal resilience assessments into new designs or major retrofits, including the use of typical and extreme weather scenarios and advanced technologies like high-performance windows.

Krelling, Amanda F↗

DISCOVR: Development of Integrated Screening, Cultivar Optimization, and Verification Research

The DISCOVR consortium has developed and is applying an integrated platform and workflow for standardized, deep characterization of highly productive and resilient microalgae strains. New strains are screened using three consecutive tiers in a conceptual down-selection funnel to arrive at the most promising strains. At tier I, strains are screened on gradient incubators to determine their temperature and salinity tolerance range, and to evaluate their resistance to infectious agents (e.g., chytrids). At tier II, the strains’ winter and summer season biomass productivities are quantified in Laboratory Environmental Algae Pond Simulator (LEAPS) photobioreactors, and biomass composition is determined under N-replete and N-deplete conditions. At tier III, the best winter and summer season strains are evaluated in indoor crash ponds to determine their resilience to induced infections, and strains are tested in outdoor raceway ponds to confirm high biomass productivity and culture stability. The top strains are then evaluated in seasonal SOT outdoor pond culture trials at AzCATI, the dedicated Department of Energy SOT (State of Technology) testbed. Additional research is carried out on evaluating growth promoting molecules, reducing the impact of oxygen inhibition, optimizing pond operational conditions, measuring compositional shift dynamics, developing integrated pest management strategies, analysing culture health using 96 well-plate tools, implementing spectroradiometric monitoring and using machine learning to predict culture crashes.

Huesemann, Michael H↗

Indoor test for thermal performance evaluation on life sciences engineering (air) solar collector

The test procedure used and the results obtained from an evaluation test program conducted to obtain thermal performance data on a life sciences double-glazed air solar collector under simulated conditions is discussed. These tests were made using the Marshall Space Flight Center's solar simulator. A time constant test and incident angle modifier test were also conducted to determine the transient effect and the incident angle effect on the collector. These results and the results of the collector load test are also discussed.

Source record↗

Indoor test for thermal performance evaluation of seven Elcam fin-tube solar collector configurations

The test procedure used and the results obtained from an evaluation test program conducted to obtain thermal performance data on seven Elcam fin-tube solar collector configurations under simulated conditions are described. These tests were made using the Marshall Space Flight Center solar facilities. The Elcam fin-tube (liquid) solar collectors each consist of an absorber plate 5.9 inches wide by 83 inches long and a type M copper tube of 0.569 inch nominal inside diameter. No cover plate was used with any of the specimens. The uniqueness of each of the seven configurations is described, and tests were performed on each separate configuration.

Source record↗

Assessing the Energy Resilience of Office Buildings: Development and Testing of a Simplified Metric for Real Estate Stakeholders

Increasing concern over higher frequency extreme weather events is driving a push towards a more resilient built environment. In recent years there has been growing interest in understanding how to evaluate, measure, and improve building energy resilience, i.e., the ability of a building to provide energy-related services in the event of a local or regional power outage. In addition to human health and safety, many stakeholders are keenly interested in the ability of a building to allow continuity of operations and minimize business disruption. Office buildings are subject to significant economic losses when building operations are disrupted due to a power outage. We propose “occupant hours lost” (OHL) as a means to measure the business productivity lost as the result of a power outage in office buildings. OHL is determined based on indoor conditions in each space for each hour during a power outage, and then aggregated spatially and temporally to determine the whole building OHL. We used quasi-Monte Carlo parametric energy simulations to demonstrate how the OHL metric varies due to different building characteristics across different climate zones and seasons. The simulation dataset was then used to develop simple regression models for assessing the impact of ten key building characteristics on OHL. The most impactful were window-to-wall ratio and window characteristics. The regression models show promise as a simple means to assess and screen for resilience using basic building characteristics, especially for non-critical facilities where it may not be viable to conduct detailed engineering analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A zone-level occupancy counting system for commercial office spaces using low-resolution time-of-flight sensors

Understanding the locations of occupants in a commercial built environment is critical for realizing energy savings by delivering lighting, heating, and cooling only where it is needed. In this paper, we present an indoor occupancy counting system using a sparse array of inexpensive, low-resolution, and privacy-preserving time-of-flight sensors. We develop and validate an algorithm for zonal occupancy counting that can deal with multiple people walking underneath the sensors in arbitrary directions, and evaluate the system both in realistic simulations of office spaces and in a real-world installation. Finally, we found that our system has an error rate of around 0.4%, resulting in highly accurate person localization and zone counting using only a few sensors per space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modeling, Monitoring and Fault Diagnosis of Spacecraft Air Contaminants

Control of air contaminants is a crucial factor in the safety considerations of crewed space flight. Indoor air quality needs to be closely monitored during long range missions such as a Mars mission, and also on large complex space structures such as the International Space Station. This work mainly pertains to the detection and simulation of air contaminants in the space station, though much of the work is easily extended to buildings, and issues of ventilation systems. Here we propose a method with which to track the presence of contaminants using an accurate physical model, and also develop a robust procedure that would raise alarms when certain tolerance levels are exceeded. A part of this research concerns the modeling of air flow inside a spacecraft, and the consequent dispersal pattern of contaminants. Our objective is to also monitor the contaminants on-line, so we develop a state estimation procedure that makes use of the measurements from a sensor system and determines an optimal estimate of the contamination in the system as a function of time and space. The real-time optimal estimates in turn are used to detect faults in the system and also offer diagnoses as to their sources. This work is concerned with the monitoring of air contaminants aboard future generation spacecraft and seeks to satisfy NASA's requirements as outlined in their Strategic Plan document (Technology Development Requirements, 1996).

Ramirez, W. Fred↗

Enhancing EnergyPlus capabilities to model dynamic building envelopes using python plugin

Nearly half of the energy consumption in the United States is related to buildings, resulting in an urgent need to develop innovative technologies to improve building energy efficiency. Dynamic building envelopes, comprising switchable insulation and thermal energy storage materials, have been proposed recently as a promising solution to reduce buildings' heating and cooling loads by thermally coupling the indoor environment with the ambient environment when beneficial while decoupling them when outdoor conditions are not favorable. Although various related technologies are still underway, the whole-building energy modeling tools, like EnergyPlus, do not have the capability to simulate the transient and dynamic nature of dynamic envelope materials and components to accurately predict their impact on building energy use. The objective of this study is to formulate a method in EnergyPlus simulation engine to model multilayer envelopes, comprising dynamic building materials with variable thermophysical properties, and discuss the changes made to the program using a Python plugin. Furthermore, the thermal performance of the dynamic envelopes using the proposed method is compared and verified with the results from a well-established commercial code, COMSOL Multiphysics. A parametric assessment is also conducted to evaluate the energy efficiency benefits of dynamic envelopes in a single-family residential building, demonstrating total annual energy savings up to 11.6 %, when a dynamic envelope operates alone, and up to 18.2 % when it is combined with a thin layer of phase change material as a thermal storage medium. Finally, a United States wide energy efficiency assessment is presented to showcase the geographical spread of the energy savings. The method designed and implemented in this study provides the researchers with the ability to implement their dynamic insulation methods in EnergyPlus and evaluate the whole building energy impact.

25 ENERGY STORAGE↗

Thermal Resilience of Residential Building with Thermally Anisotropic Building Envelope Connected to Geothermal Sources

Heat waves and cold snaps have become more frequent and more intense because of climate change. A heat wave and a cold snap are a period of excessively hot and cold weather, respectively, that poses severe risks to building occupants’ health, especially for vulnerable people. They increase electrical energy consumption and put high stress on the grid which leads to potential power outages. Therefore, it is critical to assess and actively improve the thermal resilience of buildings to cope with heat waves, cold snaps, and power outages. The thermally anisotropic building envelope (TABE) is a novel active building envelope that can save energy while maintaining thermal comfort in buildings by redirecting heat and coolness from building envelopes to hydronic loops. When connecting to a ground thermal loop (GL), TABE can utilize the relatively stable temperature of the ground to protect the indoor environment during heat waves and cold snaps. This study assesses the thermal resilience of residential buildings that installed TABE and used ground thermal energy to supply the hydronic loops, abbreviated as ground thermal loop or TABE+GL. The simulation and analysis are conducted for the US Department of Energy prototype single-family detached residential building in the hot climate of Miami, Florida and Tucson, Arizona, and the cold climate of Denver, Colorado, and Rochester, Minnesota. Heat waves and cold snaps were obtained from the historical weather data of 1998-2020 for the studied regions. Three thermal resilience metrics, including the standard effective temperature (SET) degree-hours, the Heat Index, and the Hours of Safety (HOS) were used to quantify the effect of TABE+GL. The results showed that buildings installed TABE+GL could significantly reduce the average SET degree-hours above 30°C, increase HOS, and greatly improve thermal resilience.

Shen, Zhenglai↗

Assessing thermal resilience of an assisted living facility during heat waves and cold snaps with power outages

Extreme hot and cold weather events are becoming more frequent, intense, and longer due to climate change. When these events occur coincidentally with power outages, the resulting extreme indoor temperatures pose a severe health hazard for occupants. This study conducted a holistic modeling and analysis of an assisted living facility, where senior residents live, to assess its thermal resilience performance under a six-day heat wave in 2015 and a three-day cold snap in 2021 with power outages. Impacts of 13 energy efficiency measures on thermal resilience and backup power capacity of the facility were evaluated. Three thermal resilience metrics: the SET (standard effective temperature) degree-hours, the Heat Index, and the Hours of Safety, were used and calculated from the EnergyPlus simulation models. Furthermore, major findings are: (1) the facility would suffer from extreme temperatures during the cold and hot events without a power supply, not meeting the passive survivability requirements; (2) most passive envelope measures improve thermal resilience for both hot and cold events, but making the building envelope airtight results in conflicting performance between the hot and cold events; (3) natural ventilation is an effective measure to mitigate summer indoor overheating; and (4) the energy efficiency package can reduce backup power capacity by 19% for the three-day cold snap. It is recommended that building technologies and design strategies be evaluated to consider co-benefits of energy use, thermal resilience, and backup power needs through building energy codes or policies for existing and new buildings, which are transitioning for decarbonization and climate resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Open-cycle thermochemical energy storage for building space heating: Practical system configurations and effective energy density

Salt-hydrate thermochemical materials (TCM) are promising candidates for energy storage systems for building space heating due to their high theoretical energy density and the need for low regeneration temperature. However, water vapor is required to drive the hydration process of the TCM reactor, which poses a challenge during winter when water vapor is typically scarce. Using indoor air directly lowers the building's humidity to an unconformable level in practice, while the cold outdoor air contains limited moisture. Here we consider different integration strategies for open-cycle TCM reactors in buildings and develop a model to simulate their thermal performance across diverse buildings and climates, specifically for building space heating. The potential energy densities and the levelized cost of storage of the TCM reactor are evaluated in practical scenarios to demonstrate the load-shifting potential of TCM systems for heating applications. We use a strontium chloride (SrCl 2 )-based composite as the baseline and explore the impact of various reactor and material changes to the energy density and levelized cost of storage.

25 ENERGY STORAGE↗

Assessing the use of portable air cleaners for reducing exposure to airborne diseases in a conference room with thermal stratification

The COVID-19 pandemic has highlighted the need for strategies that mitigate the risk of aerosol disease transmission in indoor environments with different ventilation strategies. It is necessary for building operators to be able to estimate and compare the relative impacts of different mitigation strategies to determine suitable strategies for a particular situation. Using a validated CFD model, this study simulates the dispersion of exhaled contaminants in a thermally stratified conference room with overhead heating. The impacts of portable air-cleaners (PACs) on the room airflow and contaminant distribution were evaluated for different PAC locations and flow rates, as well as for different room setups (socially distanced or fully occupied). To obtain a holistic view of a strategy's impacts under different release scenarios, we simultaneously model the steady-state distribution of aerosolized virus contaminants from eight distinct sources in 18 cases for a total of 144 release scenarios. The simulations show that the location of the source, the PAC settings, and the room set-up can impact the average exposure and PAC effectiveness. For this studied case, the PACs reduced the room average exposure by 31%-66% relative to the baseline case. Some occupant locations were shown to have a higher-than-average exposure, particularly those seated near the airflow outlet, and occupants closest to sources tended to see the highest exposure from said source. We found that these PACs were effective at reducing the stratification caused by overhead heating, and also identified at least one sub-optimal location for placing a PAC in this space.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Impact of Mass Wood Walls on Building Energy Use, Peak Demand, and Thermal Comfort

Thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours. Cross-Laminated Timber (CLT) and other mass wood products provide thermal mass to the building envelope in a lighter and more environmentally friendly form than concrete. However, the influence of CLTs on heating and cooling energy, peak energy demand, and the indoor climate is not well-known. This project was formed to find the energy efficiency benefits of mass timber structures. The objectives were to (1) test the thermal performance of insulated mass wall structures in controlled laboratory conditions, (2) validate simulation models to expand performance to natural climatic conditions, (3) isolate the impact of the thermal properties of wood (thermal mass, thermal conductivity, moisture storage) on heating and cooling energy use and peak energy demand, and to optimize the performance. Currently, the designs used for CLT buildings have focused on structural and fire issues, and they do not consider the thermal mass benefits. Therefore, the thermal performance is not necessarily optimized.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The interactive indoor-outdoor building energy modeling for enhancing the predictions of urban microclimates and building energy demands

There is a lack of an urban building energy modeling framework that considers the influence of surrounding buildings and local urban climate on building thermal performance. This can lead to inaccurate results since the thermal performance of individual buildings is heavily influenced by their surrounding built and climatic environment. This study establishes an interactive indoor-outdoor building energy modeling method to enhance the predictions of urban microclimates and building energy demands by coupling an urban physics model with a physics-based building energy model. Validation of the interactive coupling scheme uses field measurement datasets. Parametric simulation and analysis are conducted to understand the influence of the roof-to-canyon width ratio, canyon orientation, and ground vegetation fraction on canyon temperature, building energy consumption, and energy demand. Furthermore, the impacts of building energy model complexity (e.g., detailed vs. simplified building models) and coupling approaches on canyon temperature and building energy profiles are demonstrated using two case study buildings. In comparison with the one-way coupling approach, cooling energy consumption predicted with the dynamic two-way coupling approach varies by 3.5% and 0.5% for the detailed medium office building model and high-rise building model, respectively, and peak cooling demand varies by 8.4% and 7.0% for the detailed medium office building model and high-rise building model, respectively. Here this study also suggests that adopting a complex two-way coupling approach with environmental data exchange at various elevations is necessary for modeling tall buildings at the urban scale.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An encoder–decoder LSTM-based EMPC framework applied to a building HVAC system

Numerous studies have demonstrated the benefit of economic model predictive control (EMPC) applied to building heating, ventilation, and air conditioning (HVAC) systems. However, the construction and training of predictive models for building HVAC systems are widely recognized as a key technological barrier preventing large-scale adoption of EMPC for buildings. In this work, an encoder–decoder long short-term memory-based EMPC framework is developed. The key advantage of the approach is that a model may be automatically generated from a list of inputs and outputs. From the definition of inputs and outputs, the constructed model may be trained and automatically embedded into the EMPC framework for real-time estimation and control. The overall end-to-end EMPC framework from model training to on-line estimation and control are described. To this end, the encoder–decoder model provides a natural framework for state estimation (encoder), which is required to provide an initial condition for the predictive model of EMPC (decoder). Closed-loop simulations using EnergyPlus are performed to demonstrate the approach. The simulated closed-loop system consists of a building zone from a multi-zone building, which is served by an air handling unit-variable air volume HVAC system. For the HVAC example considered, the trained encoder–decoder model can predict the indoor air temperature and HVAC sensible cooling rate of a building zone over a two-day horizon with high accuracy. Overall, we find that considering a time-of-use electric rate structure, the EMPC, which manipulates the zone temperature setpoint, can reduce the HVAC power consumption cost relative to keeping the zone temperature setpoint at its maximum value (i.e., minimum energy approach).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measured indoor PM2.5, black carbon, and oxidative potential before and after replacing gas with induction cooking in asthmatic households

Cooking is a major source of fine particulate matter (PM) in homes and evidence to date is inconclusive about the impact of cooking fuel on measures of residential PM exposure. The Cooking Energy and Ventilation Impacts on Children's Asthma (CEVICA) study measured cooking frequency, range hood use, indoor air quality (IAQ) and respiratory health indicators of children with asthma living in homes with gas stoves in California's San Joaquin Valley. Intensive measurements occurred over three 2-week intensive periods: at baseline and at the end of two consecutive 3-month study phases. Participants were randomly assigned to have their gas stoves replaced with electric induction at the start of Phase 1 or Phase 2. As part of the IAQ assessment, we collected particulate matter on Teflon filters using ultrasonic personal air samplers (UPAS). The filters were analyzed to quantify time-integrated PM 2.5 mass concentration, black carbon (BC) oxidative potential (OP). OP was measured using the SLF-OH assay, an acellular chemical assay that quantifies production of OH radicals in simulated lung fluid (SLF). Across all comparisons, PM 2.5 mass tended to be higher during gas cooking than induction electric cooking, although only one transition (Baseline to Phase 1) was statistically discernible at p<0.05. BC and mass-normalized OP showed no measurable differences across stove types or across phases. These preliminary findings suggest that stove fuel alone may not be the dominant determinant of indoor PM 2.5 concentrations in this sample, as previous studies have reported that indoor PM 2.5 during cooking can also be influenced by factors such as cooking practices, food and oil type, kitchen ventilation, and outdoor infiltration.

Lin, Zhuoying↗