Search NASA⌕ Search

SEARCH · Search NASA

Results for “Industrial Loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

DRDMannTurb: A Python package for scalable, data-driven synthetic turbulence

Synthetic turbulence models (STMs) are used in wind engineering to generate realistic flow fields and are employed as inputs to industrial wind simulations. Examples include prescribing inlet conditions in large eddy simulations that model loads on wind turbines and tall buildings. We are interested in STMs capable of generating fluctuations based on prescribed second-moment statistics since such models can simulate environmental conditions that closely resemble on-site observations. To this end, the widely used Mann model (see Mann, 1994, 1998) is the inspiration for DRDMannTurb. The Mann model is described by three physical parameters: a magnitude parameter influencing the global variance of the wind field and corresponding to the Kolmogorov constant multiplied by the rate of viscous dissipation of the turbulent kinetic energy to the two-thirds, αϵ 2/3 , a turbulence length scale parameter L, and a nondimensional parameter Γ related to the lifetime of the eddies. A number of studies, as well as international standards (e.g., those by the International Electrotechnical Commission (IEC)), include recommended values for these three parameters with the goal of standardizing wind simulations according to observed energy spectra. Yet, having only three parameters, the Mann model faces limitations in accurately representing the diversity of observable spectra. This Python package enables users to extend the Mann model and more accurately fit field measurements through flexible neural network models of the eddy lifetime function. Following Keith et al. (2021), we refer to this class of models as Deep Rapid Distortion (DRD) models. DRDMannTurb also includes a general module implementing an efficient method for synthetic turbulence generation based on a domain decomposition technique. This technique is also described in Keith et al. (2021).

17 WIND ENERGY↗

Heave-Plate Hydrodynamic Coefficients for Floating Offshore Wind Turbines - A Compilation of Data: Preprint

The National Renewable Energy Laboratory's OpenFAST software is utilized by academics and industry professionals alike to simulate offshore wind turbines. The software's modeling of hydrodynamic loads on heave plates attached to these structures relies on user specified hydrodynamic coefficients. To guide the proper selection of these coefficients and potentially develop a new functionality within OpenFAST that automatically prescribes and/or adjust the heave-plate hydrodynamic coefficients, this paper reviews past literature to examine the dependence of the added mass, damping, and drag coefficients on various relevant non-dimensional parameters, including the Keulegan-Carpenter number, the frequency parameter, and the plate thickness ratio. Existing data in the literature show strong dependence of the hydrodynamic coefficients on the Keulegan-Carpenter number. Consistent trends are observed across a range of different plate geometry, plate porosity, and flow conditions. Secondary dependence of the coefficients on the frequency parameter and plate thickness ratio is also present.

added mass↗

Roadrunner

SAND2026-17073O Roadrunner software provides a comprehensive platform for simulating the mechanical behavior of crystalline materials under various loading conditions, allowing users to investigate the effects of dislocation slip hardening and damage evolution. Developed as a fork of the Multiphysics Object Oriented Simulation Environment (MOOSE) software from Idaho National Laboratory, Roadrunner is optimized for high-performance computing and can simulate large-scale problems, enabling researchers to explore complex scenarios. Its applications include material design and optimization in aerospace and automotive industries, investigation of failure mechanisms in structural materials, and development of predictive models for crystalline materials under various loading conditions. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Lim, Hojun [Sandia National Lab. (SNL-CA), Livermo↗

Measuring Impact: Evaluating Thermal Zoning Simplification on Energy Efficiency Measures Analysis

Building Energy Modeling (BEM) is a versatile tool for designing, retrofitting, ensuring code compliance, obtaining certifications, qualifying for incentives, and enabling real-time building control. However, capturing all the details of building geometry for thermal zoning can be time-consuming, costly, and sometimes computationally challenging. As a result, modelers have been applying zoning simplification based on factors such as space functions and internal loads, as well as relying on their experience and judgment while adhering to zoning rules outlined in industry standards. Despite the prevalence of this common practice, a notable gap exists in the literature regarding studies quantifying the influence of simplified thermal zoning on the evaluation of Energy Efficiency Measures (EEMs). Recognizing this gap, this paper seeks to contribute to the field by enhancing the understanding of how the simplification of thermal zoning influences the evaluation of EEMs against a baseline design. The study utilized a medium office prototype model with a detailed floor plan featuring over 20 zones per floor covering diverse functional spaces with varying internal loads and occupancy schedules. A standard thermal zoning strategy outlined in ASHRAE Standard 90.1 Appendix G was employed as the simplified zoning method. This strategy condenses the zoning into a core zone and four perimeter zones per floor. It was compared with the detailed zoning approach, which involves one zone per space. Common Energy EEMs, such as enhanced envelope, high-efficiency appliances and equipment, and HVAC controls, were individually implemented and evaluated. The results indicate that the performance comparison between the two zoning methods varies depending on the type of measures considered. Basic measures, such as adding wall insulation, demonstrate similar energy impacts, while advanced HVAC control measures, such as static pressure reset, exhibit a more substantial difference that cannot be overlooked.

Xie, Jiarong↗

Moving beyond the Aerosol Climatology of WRF-Solar: A Case Study over the North China Plain

Numerical weather prediction (NWP), when accessible, is a crucial input to short-term solar power forecasting. WRF-Solar, the first NWP model specifically designed for solar energy applications, has shown promising predictive capability. Nevertheless, few attempts have been made to investigate its performance under high aerosol loading, which attenuates incoming radiation significantly. The North China Plain is a polluted region due to industrialization, which constitutes a proper testbed for such investigation. Here, in this paper, aerosol direct radiative effect (DRE) on three surface shortwave radiation components (i.e., global, beam, and diffuse) during five heavy pollution episodes is studied within the WRF-Solar framework. Results show that WRF-Solar overestimates instantaneous beam radiation up to 795.3 W m -2 when the aerosol DRE is not considered. Although such overestimation can be partially offset by an underestimation of the diffuse radiation of about 194.5 W m -2 , the overestimation of the global radiation still reaches 160.2 W m -2 . This undesirable bias can be reduced when WRF-Solar is powered by Copernicus Atmosphere Monitoring Service (CAMS) aerosol forecasts, which then translates to accuracy improvements in photovoltaic (PV) power forecasts. This work also compares the forecast performance of the CAMS-powered WRF-Solar with that of the European Centre for Medium-Range Weather Forecasts model. Under high aerosol loading conditions, the irradiance forecast accuracy generated by WRF-Solar increased by 53.2% and the PV power forecast accuracy increased by 6.8%.

54 ENVIRONMENTAL SCIENCES↗

A Combined Computational and Mathematical Analysis of Interconnect Fatigue Potential in Photovoltaic Modules

A finite element model of a 60-cell monocrystalline silicon glass-polymer photovoltaic module was simulated with ±1.0 kPa and ±2.4 kPa loads applied to the glass to calculate the deformation under load. Cell-to-cell displacements were used to approximate interconnect strain and stress. A mathematical fatigue cycle life relation was fitted to data for the interconnect material (copper), to generate a life prediction at each interconnect location based on the local stress means, reversal extents, and amplitudes. Interconnect stress was found to be significantly asymmetric about zero despite symmetric positive and negative module loads due to laminate thickness offsets about the neutral plane and the effects of module framing. Cycle life results indicated that interconnect fatigue failure was unlikely to occur over a 30-year lifetime of conservative wind and snow load cycles since the typical cell design feature of leaving some unconstrained length between the cell edge and first solder pad increases the effective gauge length and decreases the stress levels below the material endurance limit. Follow-up analyses found that 3.6 mm and 6.4 mm were the minimum unconstrained lengths required to survive the assumed lifetime of wind and snow cycles, respectively, confirming that typical industrial module constructions with 8–15 mm unconstrained lengths should survive conservatively. Notably, large magnitude, low-cycle snow loading was consistently the limiting factor requiring a longer unconstrained interconnect length. Finally, insights and workflows from this study inform module interconnection design limits for survival against mechanical fatigue in deployment environments.

14 SOLAR ENERGY↗

Tidal Turbine Benchmarking Project: Stage I - Steady Flow Blind Predictions: Preprint

This paper presents the first blind prediction stage of the Tidal Turbine Benchmarking Project being conducted and funded by the UK's EPSRC and Supergen ORE Hub. In this first stage, only steady flow conditions, at low and elevated turbulence (3.1%) levels, were considered. Prior to the blind prediction stage, a large laboratory scale experiment was conducted in which a highly instrumented 1.6m diameter tidal rotor was towed through a large towing tank in well-defined flow conditions with and without an upstream turbulence grid. Details of the test campaign and rotor design were released as part of this community blind prediction exercise. Participants were invited to use a range of engineering modelling approaches to simulate the performance and loads of the turbine. 26 submissions were received from 12 groups from across academia and industry using solution techniques ranging from blade resolved computational fluid dynamics through actuator line, boundary integral element methods, vortex methods to engineering Blade Element Momentum methods. The comparisons between experiments and blind predictions were extremely positive helping to provide validation and uncertainty estimates for the models, but also validating the experimental tests themselves. The exercise demonstrated that the experimental turbine data provides a robust data set against which researchers and design engineers can test their models and implementations to ensure robustness in their processes, helping to reduce uncertainty and provide increased confidence in engineering processes. Furthermore, the data set provides the basis by which modellers can evaluate and refine approaches.

benchmarking↗

FY25 Electric Grid Security Annual Report

Sandia’s Electric Grid Security program advances a national vision of energy dominance and accessibility, while applying our national security -emphasis on ensuring of a secure, resilient, and affordable electric system for all users. Our achievements reflect a strategic approach combining technology development; modeling, simulation, and data analytics; and partnered demonstrations and outreach to further the adoption of advanced grid and storage technologies. Our FY25 efforts leverage the strengths of our partnerships—spanning Sandia’s core science and technology competencies as well as external technology leaders—to develop the solutions today which enable the grid of tomorrow. Key accomplishments in this report that support our strategy span our technical program areas and include: • New open-source analytical tools for systems -level planning and optimization, including significant advances to the QuESt analytical environment; • Further advancement of artificial intelligence and machine learning to enhanced grid operations and planning as we rise to the challenge of new large loads; • Development of solid-state power conversion technologies and a new medium-voltage research lab; • New technologies to assess wildfire vulnerabilities and mitigate potential impacts; • Advanced applications of new cybersecurity technologies with industry partners; • Contributions to understanding the impacts of electromagnetic pulses and geomagnetic disturbances on grid components; and • Digital twin development for hybrid microgrids with multiple generators, storage, and loads. This report indicates key areas of research and engagement and summarizes the impact of Sandia’s contributions through notable accomplishments, journal publications, patents, and technical conferences and presentations. It is provided with the hope that readers discover ways we can further team to create our modern grid and apply the outcomes of our efforts. The bulk of work described herein is funded by several offices within the U.S. Department of Energy (USDOE), including the Office of Electricity (OE); Cybersecurity, Energy Security, and Emergency Response (CESER); former offices such as the Office of Energy Efficiency and Renewable Energy (EERE), the Grid Deployment Office (GDO), the Office of Clean Energy Demonstrations (OCED), and other key programs at USDOE. As we continue to state in these annual reports, the contributors to our successes are too numerous to name here, though our team wishes to express our deep gratitude to the numerous program and project sponsors at the US Department of Energy, who often function equally as technical collaborators; our many partners in industry, academia, utilities, and other national labs; and fellow researchers and business partners at Sandia whose leadership and creativity have enabled the accomplishments described herein.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Building Load Control to Facilitate High Penetration of Solar Photovoltaic Generation (Final Technical Report)

Solar photovoltaic (PV) resources are the most common form of distributed generation in residential and commercial customer premises within electric distribution networks. A higher penetration of PV generation in distribution circuits will impose challenges on maintaining service voltages within the range of industry standards, power quality, and power flow. Buildings consume 74% of the electricity produced in the United States, and a significant portion of the building load is dispatchable, making them responsive to electrical grid needs. Oak Ridge National Laboratory—in collaboration with Southern Company; the University of Tennessee, Knoxville; and the Georgia Institute of Technology—is examining the PV integration issues in distribution-level electrical grids and developing integrated demand-side control and communication systems to enable responsive loads. The proposed responsive loads mechanism performs renewable generation following to increase the penetration of solar PV within each feeder. The specific objectives of this project are to (1) examine distribution-level PV integration scenarios to understand requirements, (2) undertake an end-to-end simulation-based design of a distributed control strategy of loads geographically near the PV generation asset to minimize the effect on the distribution feeder, (3) deploy and demonstrate the control technology developed in partnership with utilities, and (4) perform a scalability analysis at the utility scale. This 3-year integrated project aims to develop, demonstrate, and validate demand-side control technology to enable increased the penetration of renewables while mitigating challenges that arise due to their intermittency. Activities in Budget Period (BP) 1 focused on a literature review and the formal design of a control system for integrating local distribution with generation and loads. The team used modeling and simulation to evaluate the impact of varying buildings loads, variable PV generation, and power flow dynamics on the distribution circuit. The dynamic models developed in BP 1 were used in BP 2 to develop a model-based control design and a test bed. The test bed has enabled the simulation-based testing and comparison of different control designs and formulations applied to different configurations of the distribution grid, PVs, and building loads. The control approaches developed in BP 2 were implemented in BP 3 in the form of hardware deployed at the Central Baptist Church (CBC) in Knoxville, Tennessee, for testing and evaluation. The outcome of this project was the development and demonstration of open-source, low-cost, low-touch sensing and control retrofits to distributed PV generation and building loads that, in a coordinated fashion, provide the load-shaping response needed to integrate high levels of renewable penetration. This research addresses the target metrics by dynamically controlling a load with solar generation variability to minimize the extent of two-way power flow, enhance reliability, facilitate high PV penetration (>100% of peak load in a line segment), and generate scalable software and hardware solutions adaptable to any penetration levels. The research and development activities are focused and designed to be impactful within the relevant 2020 targets time frame.An accurate open-source integration simulation framework for end-to-end control design was developed and deployed at the CBC facility for testing and evaluation. This final report provides a detailed review of the technical results achieved during this 3-year integrated project. A novel spectral analysis of PV data is demonstrated to derive the requirements of the control design. A detailed simulation-based analysis of PV integration at increasing penetration levels is presented using 1 year of PV data to demonstrate the impact on the distribution circuits. Two different control strategies were developed and demonstrated via simulation to track variable PV generation with adaptive load dispatch. The report concludes with a summary of accomplishments and recommendations for a path forward.

14 SOLAR ENERGY↗

Dynamic Modeling, Parameter Estimation, and Data Reconciliation of a Supercritical Pulverized Coal-Fired Boiler

A high-fidelity, spatially distributed dynamic model of a supercritical pulverized coal-fired boiler was developed for calculating transient thermal profiles of the boiler tubes, which are often not measured or unmeasurable in industrial settings due to the harsh operating conditions. In this work, rigorous models of the subcritical and supercritical steam properties, which can be highly nonlinear, were used to capture the transition between two-phase and one-phase flow, respectively, as supercritical boilers frequently transition through the critical point during load-following operation. The transient boiler model was also used for data reconciliation and parameter estimation for the purpose of model validation against industrial data. An approach was developed to reduce the size of large-scale reconciliation problem by focusing on the implementation of bias terms for the reconciled variables, which can be estimated in place of the reconciled variables themselves. In addition, a functional approximation of the reconciliation problem was defined so that it can be more simply optimized. Combining this functional approximation optimization with reformulation of the reconciliation problem considering measurement biases can significantly improve the tractability of many such large-scale problems. The validated boiler model was then used to study transient responses under load-following operation with specific attention on the calculation of unmeasurable variables.

42 ENGINEERING↗

Industrial Ergonomics And Safe Lifting Practices: Food Depot [Slides]

Injuries happen when we go beyond what tissues can handle. It's repeated loading and subsequent failure of soft tissue that seem to account for most low back pain. This presentation discusses some common causes of workplace injuries and ways to reduce the likelihood of them happening.

99 GENERAL AND MISCELLANEOUS↗

Integrated Optimization and Control of a Hybrid Gas Turbine/sCO 2 Power System

During phase-I, the project team led by Echogen Power Systems (EPS) had two primary objectives based on investigating the application of gas turbines with supercritical carbon dioxide (sCO 2 ) power cycles. The first objective was to improve the overall efficiency and performance of a hybrid gas turbine/sCO 2 power system through a joint optimization of the two subsystems (gas turbine and sCO 2 power cycle) using non-linear optimization techniques that simultaneously evaluate thermal performance of the combined cycle. The hybrid power system included several points of interaction, including (but not limited to) gas turbine exhaust, fuel heating, inlet chilling and turbine cooling. The second objective was to establish a baseline transient response model of the hybrid power system and a notional microgrid and begin steps to integrate the control systems of the three major elements (gas turbine, sCO 2 cycle and grid controller). The project team established a baseline performance for a combined cycle power plant using a production gas turbine and scaled sCO 2 power cycle only utilizing exhaust heat recovery. Echogen’s non-linear techno-economic optimization code was extended by adding gas turbine component models derived from a in-house developed gas turbine design code. With the two cycles coupled by the gas turbine exhaust, design parameters of both cycles were allowed to vary simultaneously to determine performance opportunity versus isolated designs. Returning to the baseline gas turbine/sCO 2 power cycle transient models: Echogen had in-house developed sCO 2 cycle transient model in GT-Suite system simulation software, and had partnered with Siemens Finspång for gas turbine transient model, and Siemens PTI group to provide micro-grid load profile as well as hybrid power cycle generated load (power and frequency) analysis. The transient model for the SGT-750 Siemens gas turbine was a “black-box” functional mock-up interface (FMI) model developed by Siemens Industrial Turbomachinery in Finspång, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8°C. The transient model for sCO 2 power cycle was developed by Echogen in GT-SUITE 1D system simulation software platform. The basic CO 2 flow circuit has single-shaft turbomachinery with net 11.5 MW electrical power output at design conditions. The power turbine has a double-ended shaft with one end connected to synchronous generator through a fixed-ratio gearbox. The other end of power turbine is connected to the compressor through a continuously variable transmission. The major components of the sCO 2 power cycle modeled include air cooled condenser/cooler, CO 2 compressor, recuperator, two waste heat exchanger coils, power turbine, continuous variable transmission, gearbox and generator. Integration of SGT-750 transient model and sCO 2 power cycle transient model was done in Matlab Simulink. In the integrated model, the gas turbine and sCO 2 power cycle interacted at two points, first one being the gas turbine exhaust gas flow rate and temperature, which were inputs to sCO 2 power cycle model. The second point was the distribution of micro-grid load demand signal between the SGT-750 generator and sCO 2 cycle generator. For a given combined-cycle load demand, the gas turbine load demand was equal to the total demand minus the sCO 2 cycle power generated. In the present study the integrated model was simulated for two cases of grid load demand: (i) for a step change, both positive-step and negative-step, in grid load demand (ii) for a micro-grid load demand curve provided by Siemens PTI group. Finally, the time series plots representing load demand versus integrated system response were presented including the sCO 2 power cycle control system performance plots. The actual generated power and frequency of both the generators, gas turbine and sCO 2 power cycle, was supplied to Siemens PTI group for dynamic grid assessment, results of which are provided in appendices.

03 NATURAL GAS↗

Intelligent industrial demand response to increase grid flexibility and reliability: A review

The rapid transition toward renewable energy has introduced challenges in grid stability due to the intermittency of non-dispatchable sources like solar and wind. Industrial Demand Response (IDR) offers a promising, cost-effective solution that adjusts energy consumption patterns to align with supply, increases renewable utilization, and reduces costs. This review provides an updated analysis of IDR, sorting technologies into five categories: energy storage, scheduled energy usage, operational flexibility, on-site generation, and intelligent operations. Energy storage solutions, while requiring little flexibility, often have the longest payback periods. While slightly better, on-site generation also has longer payback periods, ranging from 5 to 20 years or more. Scheduled energy usage, operational flexibility, and intelligent operations allow significant peak reduction at lower capital costs but require greater flexibility. While 15–20 % peak reduction is within the range of all five categories, scheduled energy use and on-site energy generation are shown to have reductions of up to 70–80 % in select scenarios. Combining multiple IDR strategies from these five categories maximizes both financial and operational benefits. Synergistic approaches are shown to enhance grid stability while reducing costs. As the grid evolves, IDR will enable a more flexible, renewable-powered future that will benefit industrial facilities and the broader energy system.

Demand flexibility↗

Rational solvent molecule tuning for high-performance lithium metal battery electrolytes

Electrolyte engineering improved cycling of Li metal batteries and anode-free cells at low current densities; however, high-rate capability and tuning of ionic conduction in electrolytes are desirable yet less-studied. In this study, we design and synthesize a family of fluorinated-1,2-diethoxyethanes as electrolyte solvents. The position and amount of F atoms functionalized on 1,2-diethoxyethane were found to greatly affect electrolyte performance. Partially fluorinated, locally polar –CHF 2 is identified as the optimal group rather than fully fluorinated –CF 3 in common designs. Paired with 1.2 M lithium bis(fluorosulfonyl)imide, these developed single-salt-single-solvent electrolytes simultaneously enable high conductivity, low and stable overpotential, >99.5% Li||Cu half-cell efficiency (up to 99.9%, ±0.1% fluctuation) and fast activation (Li efficiency >99.3% within two cycles). Combined with high-voltage stability, these electrolytes achieve roughly 270 cycles in 50-μm-thin Li||high-loading-NMC811 full batteries and >140 cycles in fast-cycling Cu||microparticle-LiFePO 4 industrial pouch cells under realistic testing conditions. The correlation of Li + –solvent coordination, solvation environments and battery performance is investigated to understand structure–property relationships.

25 ENERGY STORAGE↗

Parametric Finite Element Analysis of Naturally Corroded Steel Specimens Using 3D Surface Laser Scans

Corrosion is considered a uniform thickness reduction design guideline of the maritime industry. However, additionally, the corroded and irregular morphology of the surface affects the steel's load-bearing capacity and its impact on the strength and elongation behaviour of the steel is not yet fully understood. These effects on the local behaviour of steel structures under tensile loading were investigated with tensile tests on naturally corroded steel specimens and nonlinear finite element simulations including the corroded surface morphology with a uniform surface idealation. The models also include the deformed specimen shape. The developed approach led to highly accurate parametric finite element models predicting the ultimate tensile strength and longitudinal position of fracture. The results show that all included aspects are essential for accurate simulations, while solely the maximum available surface resolution was not as decisive.

corrosion↗

Anomaly Detection, Localization and Classification using Drifting Synchrophasor Data Streams

With ongoing automation and digitization of the electric power system, several Phasor Measurement Units(PMUs) have been deployed for monitoring and control. PMU data can have multiple anomalies, and many of the researchers in the past have concentrated on training machine/deep learning algorithms offline for anomaly detection over PMU data (i.e., not in real time). These machine/deep learning algorithms, when trained offline on a sample rather than a population of the dataset, fail to consider the dynamic behavior of the power grid in real-time, resulting in low accuracy. Considering the dynamic behavior of the power grid (e.g., change in load, generation, distributed energy resources (DERs) switching, network, controls), the definition of data anomalies varies in time and requires online training. A fundamental challenge is to enable online (i.e., real-time) training of machine/deep learning algorithms for anomaly detection over streaming PMU data. While machine/deep learning is often desirable to manage data streams, training a deep learning algorithm over streaming PMU data is nontrivial due to changes in data statistics caused by dynamic streaming data. This paper proposes PMUNET: a novel device-level deep learning-based data-driven approach for anomaly detection, localization, and classification over streaming PMU data, using online learning and multivariate data-drift detection algorithm .Two variants of PMUNET, Dynamic data Change Driven Learning (DCDL) and Continuity Driven Learning (CDL), are proposed and compared. DCDL aims to train the deep learning algorithm whenever the definition of anomaly changes due to the power grid dynamics. On the other hand, CDL continuously trains the deep learning algorithm over the PMU data-stream. The experimental results verify that DCDL outperforms CDL and other efficient anomaly detection methods over multiple events such as faults and load/ generator/capacitor/DERs variations/switching for IEEE 14 and 39 Bus test system as well as real PMU industrial data. The result verifies that DCDL variant of PMUNET improves over existing approach with a gain of 2% - 10% in terms of accuracy, false-positive rate, and false-negative rate.

adversarial deep learning↗

Plant Reload Optimization (prlo)

The PRLO framework is built on a modular and extensible architecture that tightly couples advanced evolutionary optimization algorithms with nuclear fuel depletion solvers (i.e., nuclear physics neutronics code). It supports exploring complex, high-dimensional design spaces constrained by user-specified operational, safety, and economic constraints. Objectives such as minimizing fresh fuel enrichment, flattening radial and axial power distributions, and maximizing discharge burnup are evaluated. PRLO’s equilibrium cycle optimization capability enables the identification of core configurations that maintain fuel cycle sustainability over extended planning horizons. Its integration with the RAVEN platform facilitates optimization of loading patterns or fuel shuffling schemes across multiple cycles. The interface with SIMULATE, a licensed industry-standard nodal code developed by Studsvik, ensures accurate neutronic and thermal-hydraulic feedback for reactor core design. PRLO’s automated workflow engine supports iterative design refinement, enabling utilities to streamline core design processes and meet evolving performance and regulatory targets.

Kim, Junyung [Idaho National Laboratory] (00090005↗

Simulated Adhesive Response to Aging (CRADA 453 Final Report)

The goal of this project was to develop a suite of molecular models to investigate adhesive performance as a result of the presence of different levels of moisture. These different levels of moisture are accepted in the adhesives community to represent different states of aging. First, our team modeled the adhesive’s crosslinked structure. Next, we modeled adding water to the crosslinked structure and used high performance computing resources to simulate water diffusion through the bulk adhesive and possible sites for chain scission. Finally, we modeled the response of the simulated adhesive to tensile loads at various levels of moisture content. These simulations were validated by experimental characterization by the industry partner. We found that the Young’s modulus of the adhesive decreased by about 30% when the water content increased to 3 wt.%. Our simulations also identified the likely site where the polymer chain could break. Our integration of molecular level simulations and mechanical property predictions using high performance computing with experimental studies of a hydrated epoxy system has yielded fundamental insights that will help industry advance lightweight joining technologies.

36 MATERIALS SCIENCE↗