Inlet total pressure loss due to acoustic wall treatment

The effect of diffuser wall acoustic treatment on inlet total pressure loss was experimentally determined. Data were obtained by testing an inlet model with 10 different acoustically treated diffusers differing only in the design of the Helmholtz resonator acoustic treatment. Tests were conducted in a wind tunnel at forward velocities to 41 meters per second for inlet throat Mach numbers of .5 to .8 and angles of attack as high as 50 degrees. Results indicate a pressure loss penalty due to acoustic treatment that increases linearly with the porosity of the acoustic facing sheet. For a surface porosity of 14 percent the total pressure loss was 21 percent greater than that for an untreated inlet.

Miller, B. A.↗

Aerodynamic Shape Optimization of the STARC-ABL Concept for Minimal Inlet Distortion

The NASA single-aisle turboelectric aircraft with an aft boundary layer propulsor (STARC-ABL) concept utilizes a novel electrically driven aft fan that ingests the fuselage boundary-layer for increased propulsive efficiency. In this paper we examine how aerodynamic shaping of the fuselage diffuser and nacelle inlet can reduce the flow distortion at the aft fan. Adjoint-based aerodynamic shape optimization with the ARP1420 distortion metric objective is used to automatically determine the optimal shapes for minimal fan-face distortion. Single and multipoint optimizations are carried out for simplified body-duct and wing-body-duct configurations. These two configurations highlight the importance of including the wing downwash effects when designing the propulsor. The optimizations showed the body-duct configuration can obtain cruise distortion values of approximately 1% while the wing-body-duct configuration can obtain distortion values of just over 2%.

Kenway, Gaetan K. W.↗

Supersonic throughflow fans for high-speed aircraft

Increased need for more efficient long-range supersonic flight has revived interest in the supersonic throughflow fan as a possible component for advanced high-speed propulsion systems. A fan that can operate with supersonic inlet axial Mach numbers would reduce the inlet losses incurred in diffusing the flow from supersonic Mach numbers to a subsonic one at the fan face. In addition, the size and weight of an all-supersonic inlet will be substantially lower than those of a conventional inlet. However, the data base for components of this type is practically nonexistent. Therefore, in order to furnish the required information for assessing the potential for this type of fan, the NASA Lewis Research Center has begun a program to design, analyze, build, and test a fan stage that is capable of operating with supersonic axial velocities from inlet to exit. The objectives are to demonstrate the feasibility and potential of supersonic throughflow fans, to gain a fundamental understanding of the flow physics associated with such systems, and to develop an experimental data base for design and analysis code validation. A brief overview of past supersonic throughflow fan activities are provided; the technology needs discussed; the design of a supersonic throughflow fan stage, a facility inlet, and a downstream diffuser described; and the results from the analysis codes used in executing the design are presented. Also presented is an engine concept intended to permit establishing supersonic throughflow within the fan on the runway and maintaining the supersonic throughflow condition within the fan throughout the flight envelope.

Ball, Calvin L.↗

Poppet valve control of throat stability bypass to increase stable airflow range of a Mach 2.5. inlet with 60 percent internal contraction

The throat of a Mach 2.5 inlet with a coldpipe termination was fitted with a stability-bypass system. System variations included several stability bypass entrance configurations. Poppet valves controlled the bypass airflow. The inlet stable airflow range achieved with each configuration was determined for both steady state conditions and internal pulse transients. Results are compared with those obtained without a stability bypass system. Transient results were also obtained for the inlet with a choke point at the diffuser exit and for the inlet with large and small stability bypass plenum volumes. Poppet valves at the stability bypass exit provided the inlet with a stable airflow range of 20 percent or greater at all static and transient conditions.

Mitchell, G. A.↗

Inlet total pressure loss due to acoustic wall treatment

Experimental determination of the effect of diffuser wall acoustic treatment on inlet total pressure loss. Data were obtained by testing an inlet model with 10 different acoustically treated diffusers differing only in the design of the Helmholtz resonator acoustic treatment. Tests were conducted in a wind tunnel at forward velocities to 41 meters per second for inlet throat Mach numbers of .5 to .8 and angles of attack as high as 50 degrees. Results indicate a pressure loss penalty due to acoustic treatment that increases linearly with the porosity of the acoustic facing sheet. For a surface porosity of 14% the total pressure loss was 21% greater than that for an untreated inlet. The penalty resulting from treatment increased for average throat Mach numbers above approximately .7 where local regions of sonic or supersonic surface flow were encountered. Pressure loss over the treatment was not affected by the presence of noise.

Miller, B. A.↗

Force and Pressure Recovery Characteristics at Supersonic Speeds of a Conical Spike Inlet with a Bypass Discharging from the Top or Bottom of the Diffuser in an Axial Direction

Force and pressure-recovery characteristics of a nacelle-type conical-spike inlet with a fixed-area bypass located in the top or bottom of the diffuser are presented for flight Mach numbers of 1.6, 1.8, and 2.0 for angles of attack from 0 degrees to 9 degrees. Top or bottom location of the bypass did not have significant effects on diffuser pressure-recovery, bypass mass-flow ratio, or drag coefficient over the range of angles of attack, flight Mach numbers, and stable engine mass-flow ratios investigated. A larger stable subcritical operating range was obtained with the bypass on the bottom at angles of attack from 3 degrees to 9 degrees at a flight Mach number of 2.0. At a flight Mach number of 2.0, the discharge of 14 percent of the critical mass flow of the inlet by means of a bypass increased the drag only one-fifth of the additive drag that would result for equivalent spillage behind an inlet normal shock without significant reductions in diffuser pressure recovery.

DIFFUSERS, SUBSONIC↗

Effects of small-scale, high intensity inlet turbulence on flow in a two-dimensional diffuser

The flow through a 2D experimental diffuser with channel width 2.60 cm and divergence angle (2 theta) 9 or 20 deg is investigated experimentally for inlet Reynolds number 78,300 and velocity 43.9 m/s, with and without vertical rods to generate inlet turbulence in excess of the limits defined by Hoffmann (1981) and Hoffmann and Gonzales (1983). Measurements are obtained using a thermal wall-flow-direction probe and a single hot-wire velocity probe, and the results are presented graphically. Significant increases in the pressure-recovery coefficient of the diffuser (10 percent at 9 deg and 22 percent at 20 deg) are attributed to the action of turbulence to reduce distortion and delay separation, thus creating an altered flow condition with symmetrical velocity profiles.

Hoffmann, J. A.↗

Experimental evaluation of methods for improving diffuser-exit total-pressure profiles for a side-inlet model at Mach number 1.91

Distortion effects of the following model additions or changes were studied: (1) constant-area mixing lengths at the end of the subsonic diffuser, (2) screens with systematic variations in mesh and flow-area blockage, (3) bleeds slots on the inlet cowl, and (4) a simulated compressor hub. Data at a diffuser-exit Mach number of 0.36 are compared with data of a similar study at Mach 0.20. At the higher Mach number, the same length of constant-area mixing was less effective in reducing total-pressure distortions, while the use of screens was more effective.

Klann, John L↗

Cold air performance of a tip turbine designed to drive a lift fan. 2: Partial admission

Partial admission performance was obtained for a 0.4 linear scale version of the LF460 lift fan turbine over a range of speed from 40 to 140 percent of design equivalent speed and a range of scroll inlet total to diffuser exit static pressure ratio from 2.2 to 5.0. The investigation was conducted in two parts, with each part using a different side of the turbine scroll to simulate loss of a gas generator. Each side had an arc of admission of 180. Results are presented in terms of specific work, torque, mass flow, and efficiency.

Haas, J. E.↗

Cold-air performance of a tip turbine designed to drive a lift fan

Performance was obtained over a range of speeds and pressure ratios for a 0.4 linear scale version of the LF460 lift fan turbine with the rotor radial tip clearance reduced to about 2.5 percent of the rotor blade height. These tests covered a range of speeds from 60 to 140 percent of design equivalent speed and a range of scroll inlet total to diffuser exit static pressure ratios from 2.6 to 4.2. Results are presented in terms of equivalent mass flow, equivalent torque, equivalent specific work, and efficiency.

Haas, J. E.↗

A summary of V/STOL inlet analysis methods

Recent extensions and applications of the methods are emphasized. They include the specification of the Kutta condition for a slotted inlet, the calculation of suction and tangential blowing for boundary layer control, and the analysis of auxiliary inlet geometries at angles of attack. A comparison is made with experiment for the slotted inlet. An optimum diffuser velocity distribution was developed.

Hwang, D. P.↗

Notes on the Prediction of Shock-induced Boundary-layer Separation

The present status of available information relative to the prediction of shock-induced boundary-layer separation is discussed. Experimental results showing the effects of Reynolds number and Mach number on the separation of both laminar and turbulent boundary layer are given and compared with available methods for predicting separation. The flow phenomena associated with separation caused by forward-facing steps, wedges, and incident shock waves are discussed. Applications of the flat-plate data to problems of separation on spoilers, diffusers, and scoop inlets are indicated for turbulent boundary layers.

Lange, Roy H.↗

Microfabrication of a High-Throughput Nanochannel Delivery/Filtration System

A microfabrication process is proposed to produce a nanopore membrane for continuous passive drug release to maintain constant drug concentrations in the patient s blood throughout the delivery period. Based on silicon microfabrication technology, the dimensions of the nanochannel area, as well as microchannel area, can be precisely controlled, thus providing a steady, constant drug release rate within an extended time period. The multilayered nanochannel structures extend the limit of release rate range of a single-layer nanochannel system, and allow a wide range of pre-defined porosity to achieve any arbitrary drug release rate using any preferred nanochannel size. This membrane system could also be applied to molecular filtration or isolation. In this case, the nanochannel length can be reduced to the nanofabrication limit, i.e., 10s of nm. The nanochannel delivery system membrane is composed of a sandwich of a thin top layer, the horizontal nanochannels, and a thicker bottom wafer. The thin top layer houses an array of microchannels that offers the inlet port for diffusing molecules. It also works as a lid for the nanochannels by providing the channels a top surface. The nanochannels are fabricated by a sacrificial layer technique that obtains smooth surfaces and precisely controlled dimensions. The structure of this nanopore membrane is optimized to yield high mechanical strength and high throughput.

Ferrari, Mauro↗

Viscous analyses for flow through subsonic and supersonic intakes

A parabolized Navier-Stokes code was used to analyze a number of diffusers typical of a modern inlet design. The effect of curvature of the diffuser centerline and transitioning cross sections was evaluated to determine the primary cause of the flow distortion in the duct. Results are presented for S-shaped intakes with circular and transitioning cross sections. Special emphasis is placed on verification of the analysis to accurately predict distorted flow fields resulting from pressure-driven secondary flows. The effect of vortex generators on reducing the distortion of intakes is presented. Comparisons of the experimental and analytical total pressure contours at the exit of the intake exhibit good agreement. In the case of supersonic inlets, computations of the inlet flow field reveal that large secondary flow regions may be generated just inside of the intake. These strong flows may lead to separated flow regions and cause pronounced distortions upstream of the compressor.

Povinelli, Louis A.↗

Viscous analyses for flow through subsonic and supersonic intakes

A parabolized Navier-Stokes code was used to analyze a number of diffusers typical of a modern inlet design. The effect of curvature of the diffuser centerline and transitioning cross sections was evaluated to determine the primary cause of the flow distortion in the duct. Results are presented for S-shaped intakes with circular and transitioning cross sections. Special emphasis is placed on verification of the analysis to accurately predict distorted flow fields resulting from pressure-driven secondary flows. The effect of vortex generators on reducing the distortion of intakes is presented. Comparisons of the experimental and analytical total pressure contours at the exit of the intake exhibit good agreement. In the case of supersonic inlets, computations of the inlet flow field reveal that large secondary flow regions may be generated just inside of the intake. These strong flows may lead to separated flow regions and cause pronounced distortions upstream of the compressor.

Povinelli, Louis A.↗

Low-speed performance of an axisymmetric, mixed-compression, supersonic inlet with auxiliary inlets

A test program was conducted to determine the aerodynamic performance and acoustic characteristics associated with the low-speed operation of a supersonic, axisymmetric, mixed-compression inlet with auxiliary inlets. Blow-in-auxiliary doors were installed on the NASA Ames P inlet. One door per quadrant was located on the cowl in the subsonic diffuser selection of the inlet. Auxiliary inlets with areas of 20 and 40 percent of the inlet capture area were tested statically and at free-stream Mach numbers of 0.1 and 0.2. The effects of boundary layer bleed inflow were investigated. A JT8D fan simulator driven by compressed air was used to pump inlet flow and to provide a characteristic noise signature. Baseline data were obtained at static free-stream conditions with the sharp P-inlet cowl lip replaced by a blunt lip. Auxiliary inlets increased overall total pressure recovery of the order of 10 percent.

Trefny, C. J.↗

Effect of design changes on aerodynamic and acoustic performance of translating-centerbody sonic inlets

An experimental investigation was conducted to determine the effect of design changes on the aerodynamic and acoustic performance of translating centerbody sonic inlets. Scale model inlets were tested in the Lewis Research Center's V/STOL wind tunnel. The effects of centerbody position, entry lip contraction ratio, diffuser length, and diffuser area ratio on inlet total pressure recovery, distortion, and noise suppression were investigated at static conditions and at forward velocity and angle of attack. With the centerbody in the takeoff position (retracted), good aerodynamic and acoustic performance was attained at static conditions and at forward velocity. At 0 deg incidence angle with a sound pressure level reduction of 20 dB, the total pressure recovery was 0.986. Pressure recovery at 50 deg was 0.981. With the centerbody in the approach position (extended), diffuser flow separation occurred at an incidence angle of approximately 20 deg. However, good performance was attained at lower angles. With the centerbody in the takeoff position the ability of the inlet to tolerate high incidence angles was improved by increasing the lip contraction ratio. However, at static conditions with the centerbody in the approach position, an optimum lip contraction ratio appears to exist, with both thinner and thicker lips yielding reduced performance.