Search NASA⌕ Search

SEARCH · Search NASA

Results for “Insertion device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Study of electron current extraction from a radio frequency plasma cathode designed as a neutralizer for ion source applications

Plasma cathodes are insert free devices that are developed to be employed as electron sources in electric propulsion and ion source applications as practical alternatives to more commonly used hollow cathodes. Inductively coupled plasma cathodes, or Radio Frequency (RF) plasma cathodes, are introduced in recent years. Because of its compact geometry, and simple and efficient plasma generation, RF plasma source is considered to be suitable for plasma cathode applications. In this study, numerous RF plasma cathodes have been designed and manufactured. Experimental measurements have been conducted to study the effects of geometric and operational parameters. Experimental results of this study show that the plasma generation and electron extraction characteristics of the RF plasma cathode device strongly depend on the geometric parameters such as chamber diameter, chamber length, orifice diameter, orifice length, as well as the operational parameters such as RF power and gas mass flow rate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Emittance and lifetime measurement with damping wigglers

National Synchrotron Light Source II (NSLS-II) is a new third-generation storage ring light source at Brookhaven National Laboratory. The storage ring design calls for small horizontal emittance (<1 nm-rad) and diffraction-limited vertical emittance at 12 keV (8 pm-rad). Achieving low value of the beam size will enable novel user experiments with nm-range spatial and meV-energy resolution. The high-brightness NSLS-II lattice has been realized by implementing 30-cell double bend achromatic cells producing the horizontal emittance of 2 nm rad and then halving it further by using several Damping Wigglers (DWs). This paper is focused on characterization of the DW effects in the storage ring performance, namely, on reduction of the beam emittance, and corresponding changes in the energy spread and beam lifetime. The relevant beam parameters have been measured by the X-ray pinhole camera, beam position monitors, beam filling pattern monitor, and current transformers. In this paper, we compare the measured results of the beam performance with analytic estimates for the complement of the 3 DWs installed at the NSLS-II.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnet system optimization for segmented adaptive-gap in-vacuum undulator

Segmented Adaptive Gap in-vacuum Undulator (SAGU), in which different segments have different gaps and periods, promises a considerable spectral performance gain over a conventional undulator with uniform gap and period. According to calculations, this gain can be comparable to the gain achievable with a superior undulator technology (e.g. a room-temperature in-vacuum hybrid SAGU would perform as a cryo-cooled hybrid in-vacuum undulator with uniform gap and period). However, for reaching the high spectral performance, SAGU magnetic design has to include compensation of kicks experienced by the electron beam at segment junctions because of different deflection parameter values in the segments. Here we show that such compensation to large extent can be accomplished by using a passive correction, however, simple correction coils are nevertheless required as well to reach perfect compensation over a whole SAGU tuning range. Magnetic optimizations performed with Radia code, and the resulting undulator radiation spectra calculated using SRW code, demonstrating a possibility of nearly perfect correction, are presented.

47 OTHER INSTRUMENTATION↗

Initial performances of first undulator-based hard x-ray beamlines of NSLS-II compared to simulations

Commissioning of the first X-ray beamlines of NSLS-II included detailed measurements of spectral and spatial distributions of the radiation at different locations of the beamlines, from front-ends to sample positions. Additionally, comparison of some of these measurement results with high-accuracy calculations of synchrotron (undulator) emission and wavefront propagation through X-ray transport optics, performed using SRW code, is presented.

47 OTHER INSTRUMENTATION↗

Perspectives on the generation of electron beams from plasma-based accelerators and their near and long term applications

This article first gives the authors' perspectives on how the field of plasma-based acceleration (PBA) developed and how the current experiments, theory, and simulations are motivated by long term applications of PBA to a future linear collider and an x-ray free electron laser. Here, we then focus on some early applications that will likely emerge from PBA research such as electron beam radiotherapy, directional but incoherent x-ray beams for science and technology, near single cycle continuously tunable infrared pulses for spectroscopy, and non-perturbative quantum electrodynamics enabled by PBA electron beams. In our opinion, these near term applications could be developed within the next decade with a concerted effort by the community.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Principles and applications of x-ray light sources driven by laser wakefield acceleration

One of the most prominent applications of modern particle accelerators is the generation of radiation. In a synchrotron or an x-ray free electron laser (XFEL), high energy electrons oscillating in periodic magnetic structures emit bright x rays. In spite of their scientific appeal that will remain evident for many decades, one limitation of synchrotrons and XFELs is their typical mile-long size and their cost, which often limits access to the broader scientific community. Here, this tutorial reviews the principles and prospects of using plasmas produced by intense lasers as particle accelerators and x-ray light sources, as well as some of the applications they enable. A plasma is an ionized medium that can sustain electrical fields many orders of magnitude higher than that in conventional radio frequency accelerator structures and can be used to accelerate electrons. When short, intense laser pulses are focused into a gas, it produces electron plasma waves in which electrons can be trapped and accelerated to GeV energies. This process, laser-wakefield acceleration (LWFA), is analogous to a surfer being propelled by an ocean wave. Many radiation sources, from THz to gamma-rays, can be produced by these relativistic electrons. This tutorial reviews several LWFA-driven sources in the keV-MeV photon energy range: betatron radiation, inverse Compton scattering, bremsstrahlung radiation, and undulator/XFEL radiation. X rays from laser plasma accelerators have many emerging applications. They can be used in innovative and flexible x-ray imaging and x-ray absorption spectroscopy configurations, for use in biology, industry, and high-energy density science.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Implementation of compound refractive lenses for large field-of-view x-ray phase-contrast imaging during hypervelocity impact experiments

Synchrotron x-ray phase-contrast imaging (XPCI) offers time-resolved visualization of dynamic compression phenomena, but its intrinsically small field-of-view (FOV) limits the time that key features remain in frame. A novel approach to enlarge the FOV is achieved by positioning a two-dimensional parabolic compound refractive lens (CRL) upstream of the sample to deliberately defocus the white beam. Ray-tracing simulations and XPCI measurements show that this CRL configuration can expand the beam by ∼50% vertically and ∼15% horizontally based on the full width at half-maximum of the beam. Implementing the CRL, however, attenuates the photon flux and lowers signal-to-noise ratio (SNR). Task-based analysis using a calibration grid (30 μm dots) showed that both setups fail to consistently meet the Rose criterion (SNR ≥ 5) for features of this size in single-bunch imaging. Extrapolating the measured SNR Rose values suggests that the minimum consistently detectable feature lies closer to 30–40 μm for the standard XPCI setup and above 40 μm for CRL-XPCI. Despite this limitation, the CRL configuration nearly doubles the illuminated area, enabling simultaneous tracking of front and rear observations of boron carbide targets subjected to rod and sphere impacts at 1.0–2.6 km/s. Image tracking algorithms and photonic Doppler velocimetry were used to measure penetration and rear-surface velocity histories. Together, these measurements capture crack fronts, penetration, and material breakout, offering new benchmark data for validating high-strain-rate constitutive models of ceramic materials.

Ceramic materials↗

Demonstration of Machine Learning-Based Model-Independent Stabilization of Source Properties in Synchrotron Light Sources

Synchrotron light sources, arguably among the most powerful tools of modern scientific discovery, are presently undergoing a major transformation to provide orders of magnitude higher brightness and transverse coherence enabling the most demanding experiments. In these experiments, overall source stability will soon be limited by achievable levels of electron beam size stability, presently on the order of several microns, which is still 1–2 orders of magnitude larger than already demonstrated stability of source position and current. Until now source size stabilization has been achieved through corrections based on a combination of static predetermined physics models and lengthy calibration measurements, periodically repeated to counteract drift in the accelerator and instrumentation. In this paper, we now demonstrate for the first time how the application of machine learning allows for a physics- and model-independent stabilization of source size relying only on previously existing instrumentation. Such feed-forward correction based on a neural network that can be continuously online retrained achieves source size stability as low as 0.2 μm (0.4%) rms, which results in overall source stability approaching the subpercent noise floor of the most sensitive experiments.

43 PARTICLE ACCELERATORS↗

SU-E-T-133: Dosimetric Impact of Scan Orientation Relative to Target Motion During Spot Scanning Proton Therapy

Purpose: This study seeks to evaluate the dosimetric effects of intra-fraction motion during spot scanning proton beam therapy as a function of beam-scan orientation and target motion amplitude. Method: Multiple 4DCT scans were collected of a dynamic anthropomorphic phantom mimicking respiration amplitudes of 0 (static), 0.5, 1.0, and 1.5 cm. A spot-scanning treatment plan was developed on the maximum intensity projection image set, using an inverse-planning approach. Dynamic phantom motion was continuous throughout treatment plan delivery.The target nodule was designed to accommodate film and thermoluminescent dosimeters (TLD). Film and TLDs were uniquely labeled by location within the target. The phantom was localized on the treatment table using the clinically available orthogonal kV on-board imaging device. Film inserts provided data for dose uniformity; TLDs provided a 3% precision estimate of absolute dose. An inhouse script was developed to modify the delivery order of the beam spots, to orient the scanning direction parallel or perpendicular to target motion.TLD detector characterization and analysis was performed by the Imaging and Radiation Oncology Core group (IROC)-Houston. Film inserts, exhibiting a spatial resolution of 1mm, were analyzed to determine dose homogeneity within the radiation target. Results: Parallel scanning and target motions exhibited reduced target dose heterogeneity, relative to perpendicular scanning orientation. The average percent deviation in absolute dose for the motion deliveries relative to the static delivery was 4.9±1.1% for parallel scanning, and 11.7±3.5% (p<<0.05) for perpendicularly oriented scanning. Individual delivery dose deviations were not necessarily correlated to amplitude of motion for either scan orientation. Conclusions: Results demonstrate a quantifiable difference in dose heterogeneity as a function of scan orientation, more so than target amplitude. Comparison to the analyzed planar dose of a single field hint that multiple-field delivery alters intra-fraction beam-target motion synchronization and may mitigate heterogeneity, though further study is warranted.

60 APPLIED LIFE SCIENCES↗

SU-F-T-328: Real-Time in Vivo Dosimetry of Prostate SBRT Boost Treatments Using MOSkin Detectors

Purpose: To provide in vivo measurements of dose to the anterior rectal wall during prostate SBRT boost treatments using MOSFET detectors. Methods: Dual MOSkin detectors were attached to a Rectafix rectal sparing device and inserted into patients during SBRT boost treatments. Patients received two boost fractions, each of 9.5–10 Gy and delivered using 2 VMAT arcs. Measurements were acquired for 12 patients. MOSFET voltages were read out at 1 Hz during delivery and converted to dose. MV images were acquired at known frequency during treatment so that the position of the gantry at each point in time was known. The cumulative dose at the MOSFET location was extracted from the treatment planning system at in 5.2° increments (FF beams) or at 5 points during each delivered arc (FFF beams). The MOSFET dose and planning system dose throughout the entirety of each arc were then compared using root mean square error normalised to the final planned dose for each arc. Results: The average difference between MOSFET measured and planning system doses determined over the entire course of treatment was 9.7% with a standard deviation of 3.6%. MOSFETs measured below the planned dose in 66% of arcs measured. Uncertainty in the position of the MOSFET detector and verification point are major sources of discrepancy, as the detector is placed in a high dose gradient region during treatment. Conclusion: MOSkin detectors were able to provide real time in vivo measurements of anterior rectal wall dose during prostate SBRT boost treatments. This method could be used to verify Rectafix positioning and treatment delivery. Further developments could enable this method to be used during high dose treatments to monitor dose to the rectal wall to ensure it remains at safe levels. Funding has been provided by the University of Newcastle. Kimberley Legge is the recipient of an Australian Postgraduate Award.

60 APPLIED LIFE SCIENCES↗

Sweat collection capsule

Capsule, with filter paper insert, is used to collect sweat for rate monitoring, chromatographic analysis, or active sweat gland location within specified area. Construction of capsule allows change of inserts while device remains strapped in place.

Delaplaine, R. W.↗

Voltage controller/current limiter for ac

Circuit protects ac power systems for overload failures, limits power surge and short-circuit currents to 150 percent of steady state level, regulates ac output voltage, and soft starts loads. Limiter generates dc error signal in response to line fluctuations and dumps power when overload is reached. Device is inserted between ac source and load.

Wu, T. T.↗

Dynamical Decoupling for Measuring and Suppressing Crosstalk

Dynamical decoupling (DD) is a noise-mitigating strategy in which sequences of pulses are applied to single qubits to average out their interaction with the environment. DD has been extensively studied and demonstrated for suppressing single-qubit decoherence and can be tailored for different noise spectrum. We report another important adaptation of DD where crosstalk between qubits are suppressed. We demonstrate the efficiency of this procedure on quantum circuits on superconducting transmon-based quantum devices. We designed a family of syncopated DD sequences that effectively suppress ZZ coupling between qubit pairs, which is the dominating crosstalk form on the device. We insert DD to a quantum circuit whenever single qubits are idle (often during two-qubits gates on other qubits). While standard periodic DD suppress crosstalk between these qubits and their neighbors, the syncopated DD further decouples crosstalk between these qubits. We further designed short sequences that maximize the application of DD without adding time to the quantum circuit execution. Such DD sequences yield significant improvement of the performance of the algorithm on the hardware. The performance is further boosted by combining DD with another mitigation strategy, randomized compilation. Our work demonstrated that syncopated DD is effective and practical way to suppress crosstalk in quantum circuits and serves as a great probe to characterize the crosstalk and inform hardware design.

Quantum Computing↗

Retinal instrument

In one embodiment, the present invention provides a method of removing scar tissue from an eye that includes inserting a device including an array of micro-rods into an eye, wherein at least one glass micro-rod of the array of glass micro-rods includes a sharp feature; contacting a scar tissue with the array of micro-rods; and removing the array of micro-rods and the scar tissue from the eye. In another embodiment, the present invention provides a medical device for engaging a tissue including and an array of glass micro-rods, wherein at least one glass micro-rod of the array of glass micro-rods includes a sharp feature opposite a base of the array of glass micro-rods that is connected to the cannula, wherein the sharp feature of the at least one micro-rod is angled from a plane that is normal to a face of the base of the array of glass micro-rods.

47 OTHER INSTRUMENTATION↗

Overlap junctions for superconducting quantum electronics and amplifiers

Due to their unique properties as lossless, nonlinear circuit elements, Josephson junctions lie at the heart of superconducting quantum information processing. Previously, we demonstrated a two-layer, submicrometer-scale overlap junction fabrication process suitable for qubits with long coherence times. Here, we extend the overlap junction fabrication process to micrometer-scale junctions. This allows us to fabricate other superconducting quantum devices. For example, we demonstrate an overlap junction-based Josephson parametric amplifier that uses only two layers. This efficient fabrication process yields frequency-tunable devices with negligible insertion loss, a gain of ∼30 dB, and quantum limited noise performance. Compared to other processes, the overlap junction allows for fabrication with minimal infrastructure, high yield, and state-of-the-art device performance.

Bal, Mustafa (ORCID:0000000307516774)↗

Principles, Techniques, and Applications of Tissue Microfluidics

The principle of tissue microfluidics and its resultant techniques has been applied to cell analysis. Building microfluidics to suit a particular tissue sample would allow the rapid, reliable, inexpensive, highly parallelized, selective extraction of chosen regions of tissue for purposes of further biochemical analysis. Furthermore, the applicability of the techniques ranges beyond the described pathology application. For example, they would also allow the posing and successful answering of new sets of questions in many areas of fundamental research. The proposed integration of microfluidic techniques and tissue slice samples is called tissue microfluidics because it molds the microfluidic architectures in accordance with each particular structure of each specific tissue sample. Thus, microfluidics can be built around the tissues, following the tissue structure, or alternatively, the microfluidics can be adapted to the specific geometry of particular tissues. By contrast, the traditional approach is that microfluidic devices are structured in accordance with engineering considerations, while the biological components in applied devices are forced to comply with these engineering presets. The proposed principles represent a paradigm shift in microfluidic technology in three important ways: Microfluidic devices are to be directly integrated with, onto, or around tissue samples, in contrast to the conventional method of off-chip sample extraction followed by sample insertion in microfluidic devices. Architectural and operational principles of microfluidic devices are to be subordinated to suit specific tissue structure and needs, in contrast to the conventional method of building devices according to fluidic function alone and without regard to tissue structure. Sample acquisition from tissue is to be performed on-chip and is to be integrated with the diagnostic measurement within the same device, in contrast to the conventional method of off-chip sample prep and subsequent insertion into a diagnostic device. A more advanced form of tissue integration with microfluidics is tissue encapsulation, wherein the sample is completely encapsulated within a microfluidic device, to allow for full surface access. The immediate applications of these approaches lie with diagnostics of tissue slices and biopsy samples e.g. for cancer but the approaches would also be very useful in comparative genomics and other areas of fundamental research involving heterogeneous tissue samples.

Wade, Lawrence A.↗

Lamb Wave Focusing Transducer for Efficient Coupling to Wavelength-Scale Structures in Thin Piezoelectric Films

This study describes the theoretical and experimental investigation of interdigitated transducers (IDTs) capable of producing focused acoustical beams in thin film piezo-electric materials. A mathematical formalism describing focused acoustical beams, Lamb beams, is presented and related to their optical counterparts in two- and three-dimensions. A novel Fourier domain transducer design methodology was developed and utilized to produce near diffraction limited focused beams with in a thin film AlN membrane. The properties of the acoustic beam formed by the transducer were studied by means of Doppler vibrometry implemented with a scanning confocal balanced homodyne interferometer. Fourier domain modal analysis confirmed that 85% of the acoustical power was delivered to the targeted focused beam which was constituted from the lowest order symmetric mode, while 2% was delivered unintentionally to the beam formed from the anti-symmetric mode, and the remaining power was isotropically scattered. The transmission properties of the acoustic beams as they interact with devices with wavelength scale features were also studied, demonstrating minimal insertion loss for devices in which a subwavelength, pinhole apertures was included.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗