Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrument”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Design of a first-of-A-kind instrumented advanced test reactor irradiation Capsule experiment for In situ thermal conductivity measurements of metallic fuel

Metallic fuel undergoes dramatic microstructural changes early in life due to fission gas swelling until ~2–3 at% burnup which affects the conductivity of the material, however the evolution of metallic fuel thermal conductivity during this early phase burnup has never been successfully measured in situ. The Irradiated Material Properties Accelerated Characterization Test (IMPACT) experiment will be the first in a series of experiments to irradiate advanced nuclear metallic fuel specimens with novel embedded thermal conductivity probes in ATR. In the current work the IMPACT experiment final design and supporting analysis is reported in detail. Results are evaluated for various reactor operational conditions to meet the functional requirements of the experiment. Finally, the first iteration of this IMPACT experiment will provide data regarding thermal properties evolution in uranium-zirconium (U10Zr) fuel, but this experiment vehicle is envisioned for future advanced fuels and structural materials irradiations in ATR.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data Reproducibility of Spin-Echo Small-Angle Neutron Scattering Instruments

Spin-echo small-angle neutron scattering (SESANS) is a unique method to measure structures of materials in real space with length scales from ∼ 30 μm to ∼20 µm. As shown in Figure 1, the accessible length scale of SESANS is given by its ability to encode the momentum transfer into the Larmor phase, namely Φ = $\vec{𝛿}$ ⋅ $\vec{𝑄}$, where $\vec{𝑄}$ is the momentum transfer and $\vec{𝛿}$ is the encoding vector of the setup and its projection along Q (δQ) is called spin-echo length (SEL). The spin echo length, which is synonymous with the spatial correlation distance probed, is defined as the following 𝛿𝑄 ∝ 𝜆 2 𝐵𝐿cot𝜃 where 𝜆 is neutron wavelength, B is magnetic field, L is length of the parallelogram magnetic field region, and 𝜃 is the angle between the inclined magnetic field boundary and the beam direction, as shown in Figure 1. The result of the SESANS experiment is a Hankel transformation of the SANS scattering function I(Q), which yields the correlation function of the sample in real space.

47 OTHER INSTRUMENTATION↗

Desmearing small-angle scattering data by central moment expansions of instrument resolution

This study introduces an enhanced numerical technique tailored specifically for refining 1D small-angle scattering (SAS) intensity profiles affected by smearing. Our primary objective is to address the resolution blurring commonly encountered in SAS data, particularly in systems with clearly defined correlation peaks whose spread aligns with the width of the resolution function at corresponding Q positions. Unlike previous approaches that expanded the SAS intensity using central moment expansion, the new method focuses on expanding the resolution function itself, thus eliminating artificial oscillations observed in smeared spectra due to limitations inherent in our earlier algorithm. This method is straightforward to implement, computationally efficient and consistently performs well in numerical benchmarking. To illustrate its effectiveness, we present a case study of a lamellar phase characterized by distinct peaks in its small-angle neutron scattering intensities.

central moment expansions↗

Sixteen multiple-amplifier sensing charge-coupled devices and characterization techniques targeting the next generation of astronomical instruments

We present a candidate sensor for future spectroscopic applications, such as a Stage-5 Spectroscopic Survey Experiment or the Habitable Worlds Observatory. This type of charge-coupled device (CCD) sensor features multiple in-line amplifiers at its output stage allowing multiple measurements of the same charge packet, either in each amplifier or in the different amplifiers. Recently, the operation of an eight-amplifier sensor has been experimentally demonstrated, and we present the operation of a 16-amplifier sensor. This new sensor enables a noise level of ∼1 erms− with a single sample per amplifier. In addition, it is shown that sub-electron noise can be achieved using multiple samples per amplifier. In addition to demonstrating the performance of the 16-amplifier sensor, we aim to create a framework for future analysis and performance optimization of this type of detectors. New models and techniques are presented to characterize specific parameters, which are absent in conventional CCDs and Skipper CCDs: charge transfer between amplifiers and independent and common noise in the amplifiers and their processing.

16 multiple-amplifer sensing CCD (MAS-CCD)↗

AmeriFlux Measurement Component Instrument Handbook

An AMC system was installed at the Atmospheric Radiation Measurement (ARM) Climate Research Facility’s North Slope Alaska (NSA) Barrow site, also known as NSA C1 at the ARM Data Archive, in August 2012. A second AMC system was installed at the third ARM Mobile Facility deployment at Oliktok Point, also known as NSA M1. This in situ system consists of 12 combination soil temperature and volumetric water content (VWC) reflectometers and one set of upwelling and downwelling PAR sensors, all deployed within the fetch of the Eddy Correlation Flux Measurement System. Soil temperature and VWC sensors placed at two depths (10 and 30 cm below the vegetation layer) at six locations (or microsites) allow soil property inhomogeneity to be monitored across a landscape. The soil VWC and temperature sensors used at NSA C1 are the Campbell Scientific CS650L and the sensors at NSA M1 use the Campbell Scientific CS655. The two sensors are nearly identical in function, and vendor specifications are based on the CS650 unless otherwise stated.

47 OTHER INSTRUMENTATION↗

Ultrafine Condensation Particle Counter Instrument Handbook

The Model 3776 Ultrafine Condensation Particle Counter (UCPC; pictured in Appendix A) is designed for researchers interested in airborne particles smaller than 20 nm. With sensitivity to particles down to 2.5 nm in diameter, this UCPC is ideally suited for atmospheric and climate research, particle formation and growth studies, combustion and engine exhaust research, and nanotechnology research.

47 OTHER INSTRUMENTATION↗

Stereo Cameras for Clouds (STEREOCAM) Instrument Handbook

The three pairs of stereo camera setups aim to provide synchronized and stereo calibrated time series of images that can be used for 3D cloud mask reconstruction. Each camera pair is positioned at approximately 120 degrees from the other pair, with a 17o-19o pitch angle from the ground, and at 5-6 km distance from the U.S. Department of Energy (DOE) Central Facility at the Atmospheric Radiation Measurement (ARM) Climate Research Facility Southern Great Plains (SGP) observatory to cover the region from northeast, northwest, and southern views. Images from both cameras of the same stereo setup can be paired together to obtain 3D reconstruction by triangulation. 3D reconstructions from the ring of three stereo pairs can be combined together to generate a 3D mask from surrounding views. This handbook delivers all stereo reconstruction parameters of the cameras necessary to make 3D reconstructions from the stereo camera images.

47 OTHER INSTRUMENTATION↗

Tethered Balloon System (TBS) Instrument Handbook

The Tethered Balloon System (TBS) is an unmanned aerial system composed of a helium-filled balloon, tether, winch, and sensors. Individual components of the system may change with each flight based on the desired measurements, atmospheric conditions, and flight strategy. The TBS operates within the U.S. Department of Energy (DOE)’s R-2204 Restricted Airspace, which encompasses a two-nautical-mile radius centered on Oliktok Point, Alaska that is segmented by altitude into R-2204 Low (0-1,499’ MSL or 0-457 m MSL) and R-2204 High (1,500-6,999’ MSL or 457-2133 m MSL). The TBS may operate outside of R-2204 if allowed to do so under a Certificate of Authorization from the Federal Aviation Administration.

42 ENGINEERING↗

FY26 Mid-Year Report Self-Diagnostic Capabilities for Neutron Instruments

This year we will transfer the latest version of INCC6 with last year’s self-diagnostic features to the IAEA. In FY25 we completed the development of three automated self diagnostic features into INNC6. The completion of these features marked the final stable version of INCC 6.0 ready for release to the IAEA and other users. In the first half of the Fiscal Year 2026 we have worked with LANL’s Feynman Center and Export Control office to attain a license for exporting INCC6 to the IAEA. We have successfully attained the export license for INCC6, and contacts at the IAEA have been granted permission to receive INCC6. We are in the final stage of writing the version 6 user manual. Once this is complete, we will deliver INCC6 to the IAEA for testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating the potential of short-term instrument deployment to improve distributed wind resource assessment

Distributed wind projects, which are connected at the distribution level of an electricity system or in off-grid applications to serve specific or local energy needs, often rely solely on wind resource models to establish wind speed and energy generation expectations. Historically, anemometer loan programs have provided an affordable avenue for more accurate onsite wind resource assessment, and the lowering cost of lidar systems has shown similar advantages for more recent assessments. While a full 12 months of onsite wind measurement is the standard for correcting model-based long-term wind speed estimates for utility-scale wind farms, the time and capital investment involved in gathering onsite measurements must be reconciled with the energy needs and funding opportunities that drive expedient deployment of distributed wind projects. Much literature exists to quantify the performance of correcting long-term wind speed estimates with 1 or more years of observational data, but few studies explore the impacts of correcting with months-long observational periods. This study aims to answer the question of how short you can go in terms of the observational time period needed to make impactful improvements to model-based long-term wind speed estimates. Three algorithms, multivariable linear regression, adaptive regression splines, and regression trees, are evaluated for their skill at correcting long-term wind resource estimates from the European Centre for Medium-Range Weather Forecasts Reanalysis version 5 (ERA5) using months-long periods of observational data from 66 locations across the US. On average, correction with even 1 month of observations provides significant improvement over the baseline ERA5 wind speed estimates and produces median bias magnitudes and relative errors within 0.22 m s −1 and 4 percentage points of the median bias magnitudes and relative errors achieved using the standard 12 months of data for correction. However, in cases when the shortest observational periods (1 to 2 months) used for correction are not well correlated with the overlapping ERA5 reference, the resultant long-term wind speed errors are worse than those produced using ERA5 without correction. Summer months, which are characterized by weaker relative wind speeds and standard deviations for most of the evaluation sites, tend to produce the worst results for long-term correction using months-long observations. The three tested algorithms perform similarly for long-term wind speed bias; however, regression trees perform notably worse than multivariable linear regression and adaptive regression splines in terms of correlation when using 6 months or less of observational data for correction. Translating the analysis to wind energy, median relative errors in the capacity factor are on average within 10 % using 1 month of training. If the observation period used for correction is not well correlated with the reference data, however, misrepresentation of the observed capacity factor can be substantial. The risk associated with poor correlation between the observed and reference datasets decreases with increasing training period length. In the worst-correlation scenarios, the median capacity factor relative errors from using 1, 3, and 6 months are within 47 %, 26 %, and 16 %, respectively.

17 WIND ENERGY↗

Results of South-East Flux Trap Dosimetry Measurements for the Advanced Test Reactor Critical Facility in support of Advanced Sensors and Instrumentation Development

Reactor dosimetry measurements are commonly used to validate simulation and modeling in nuclear reactor tests. Numerous standard dosimeter materials exist which are commonly utilized with sensitivities to different energy ranges of neutrons. At the Advanced Test Reactor (ATR), cobalt alloy and pure nickel wires are installed every cycle to monitor thermal- and fast-neutron fluence rates. However, there is growing interest in exploring less commonly used materials which are either more sensitive to different parts of the neutron energy spectrum or which can incorporate multiple activation paths in a single material. Epithermal and fast-neutron energies beyond the typical 1-MeV threshold are of particular interest. Two ATR-C Flux Runs took place during 2024; each flux run included supplemental dosimetry packages in the South-East Flux Trap (SEFT) Filler. The focus of the dosimetry package for flux run 23-4 was to test two novel dosimetry methods that can provide simultaneous thermal and threshold (fast) sensitivity in a single dosimeter wire. A selection of 3% Au in Cu alloyed wires were available that provided sensitivity to fast and thermal neutrons through 5 different reactions. Likewise, Fe offers multiple interaction pathways with sensitivity to both thermal and fast neutrons. The main question to be answered by these irradiations was if sufficient radioactivation would take place in the ATR-C SEFT during a nominal 20-minute irradiation at typical power levels (near 600Wth) to observe the threshold reactions that have smaller activation cross-sections than the thermal reactions without being saturated by interfering interactions and Compton continuum during the High-Purity Germanium (HPGe) measurements. The results from comparing the measurement results to anticipated activity levels provide confidence in our ability to activate both traditional and novel dosimetry materials in ATR-C, however not all the measured values matched with the predicted activities. This leaves further room for investigation both on the experimental and computational approaches for future irradiation experiments.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Experimental validation of a Kalman observer using linearized OpenFAST and a fully instrumented 1:70 model

Abstract To enable real‐time monitoring and control strategies for floating offshore wind turbines, accurate information about the state of the system is needed. This paper details the application of a Kalman filter to the UMaine VolturnUS‐S floating wind platform to provide accurate state estimates in real time using minimal system measurements. The midfidelity nonlinear simulation tool OpenFAST was used to generate the underlying linear state‐space model for the Kalman filter. This linear model and its limitations are demonstrated through comparison with experimental data collected on a 1:70 froude‐scaled model of the floating platform and tower. Using a selection of five measurements from the real system, a Kalman filter was developed to provide estimates for the remaining system states and measurements. These estimates were then validated against the experimental values collected from testing of the scale model. Validation of the Kalman filter produced accurate estimates of surge, heave, and tower base bending moment, measurements of which were not available to the Kalman filter. Performance of the Kalman filter was tested and validated over a range of sea conditions from rated wind speed to storm events and demonstrated robustness in the Kalman filter to maintain accuracy across all operating conditions despite significant error in the underlying linear model for extreme conditions.

17 WIND ENERGY↗