At least 163 records · Page 9

SRNL report for the tank waste disposition integrated flowsheet: Corrosion testing

A series of cyclic potentiodynamic polarization (CPP) tests were performed in support of the Tank Waste Disposition Integrated Flowsheet (TWDIF). The focus of the testing was to assess the effectiveness of the SRNL model for predicting the amount of nitrite inhibitor needed to prevent pitting induced by increasing halide concentrations. The testing conditions were selected to simulate the dilute process stream that is proposed to be returned to tank farms from treating the off-gas from the low activity waste melter in the Waste Treatment and Immobilization Plant.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pressure-Based Inversion and Data Assimilation System (PIDAS) for CO 2 Leakage Detection (Final Report)

This project aims to develop a Pressure-based Inversion and Data Assimilation System (PIDAS) for detecting CO 2 leakage from storage formations. Carbon capture, utilization, and sequestration (CCUS) has the potential to enable deep reductions in global carbon emissions if high storage efficiency can be achieved. A major hurdle to industrial-scale implementation of geological carbon sequestration (GCS) projects is the potential migration of fluids (either brine or injected CO 2 ) from the storage formations and the resulting legal and financial liabilities. The capability to accurately identify leakage pathways by which stored CO 2 could leak, has leaked, or is leaking from the targeted storage zone is thus of paramount importance to site licensees and regulators. Although many MVA techniques have been devised, pressure-based monitoring technology remains the most sensitive and reliable technique for early detection. Pressure-based monitoring has consistently received the highest score in terms of benefit/cost ratio and it provides the greatest potential for leakage detection with broad areal coverage. Under this project we have (a) demonstrated the utility of the proposed well testing technique for leakage detection through integrated theoretical and numerical analysis, laboratory experiments, and field tests; (b) developed effective data analysis and inversion algorithms for identifying leakage pathways by fusing data generated during well testing; (c) provided a designing tool for maximizing the utility of the developed PIDAS tool for early leakage detection.

02 PETROLEUM↗

Data-Driven Preemptive Voltage Monitoring and Control Using Probabilistic Voltage Sensitivities: Preprint

Increased penetration of distributed variable re-newable generation may cause random voltage fluctuations and violations at multiple nodes. Traditional methods of voltage control typically involve reactionary responses of capacitor banks, tap changers, and recently even smart inverters. But due to the lack of foresight in voltage violations, these controls are ineffective to completely mitigate the issue. Therefore, new methods of predicting voltage violations subject to random power injection changes in the distribution network is needed, which can be used to guide optimal and dynamic methods of voltage control. This work lays the foundation for such preemptive voltage monitoring and control by proposing an analytical and sensor data-driven voltage sensitivity analysis method. Driven by stochastic data and forecasts, the method can be used to develop probabilistic voltage sensitivities and consequently to predict system nodes with high likelihood of voltage limit violations. The effectiveness of this method is tested on IEEE 69 node distribution system integrated with distributed solar. The results demonstrate the proposed method's ability to successfully predict nodes with high probability of voltage violations for a specific time series simulation. The results also demonstrate the ability to guide timely power injection control actions to mitigate future voltage violations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

COMPARING MID-INFRARED GLOBULAR CLUSTER COLORS WITH POPULATION SYNTHESIS MODELS

Several population synthesis models now predict integrated colors of simple stellar populations in the mid-infrared bands. To date, the models have not been extensively tested in this wavelength range. In a comparison of the predictions of several recent population synthesis models, the integrated colors are found to cover approximately the same range but to disagree in detail, for example, on the effects of metallicity. To test against observational data, globular clusters (GCs) are used as the closest objects to idealized groups of stars with a single age and single metallicity. Using recent mass estimates, we have compiled a sample of massive, old GCs in M31 which contain enough stars to guard against the stochastic effects of small-number statistics, and measured their integrated colors in the Spitzer/IRAC bands. Comparison of the cluster photometry in the IRAC bands with the model predictions shows that the models reproduce the cluster colors reasonably well, except for a small (not statistically significant) offset in [4.5] - [5.8]. In this color, models without circumstellar dust emission predict bluer values than are observed. Model predictions of colors formed from the V band and the IRAC 3.6 and 4.5 {mu}m bands are redder than the observed data at high metallicities and we discuss several possible explanations. In agreement with model predictions, V - [3.6] and V - [4.5] colors are found to have metallicity sensitivity similar to or slightly better than V - K{sub s}.

79 ASTRONOMY AND ASTROPHYSICS↗

Fracture toughness and corrosion resistance of semisolid AlSi5 alloy

The aim of this work was to investigate fracture toughness and corrosion resistance of semisolid AlSi5 castings, compared to samples obtained from conventional casting operations. In order to have a semisolid microstructure, the melt alloy was treated by means of ultrasound during solidification and then poured into permanent moulds. Mechanical properties of semisolid and conventional castings were compared by means of ultimate tensile strength (R{sub m}), yield stress (Rp{sub 02}) and hardness (HV) measurements. Fracture mechanics tests were carried out on Single Edge Notched Bend (SENB) specimens, machined from castings, and pre-cracked by fatigue. These tests were performed to determine the effect of the microstructure on the J-Integral resistance (J-R) behavior and to deeply understand the ductile fracture behaviour of semisolid parts. The J-Integral versus spaced crack extension (J-{Delta}a) curves showed an improved resistance of the semisolid microstructure, due to the higher ductility. Finally, the corrosion behaviour of semisolid samples was compared to that of castings coming from solidification of fully liquid alloy by means of electrochemical potentiodynamic polarization tests. It was observed that the globular microstructure offers better quality, in terms of higher mechanical properties, as a consequence of a more uniform distribution of the solute.

36 MATERIALS SCIENCE↗

Breakaway oxidation of ZIRLO and optimized ZIRLO cladding per 10CFR50.46c criteria

The United States Nuclear Regulatory Commission (NRC) in 10CFR50.46c proposed changes to the loss of coolant accident (LOCA) criteria for LWR licensees including a new requirement to test cladding materials for breakaway oxidation. Cladding materials must be shown to resist breakaway oxidation long enough for the LOCA transient to be terminated. The onset of breakaway oxidation is characterized by a rapidly increasing rate of oxidation and the absorption of hydrogen resulting in a loss of cladding integrity. The proposed rule changes effectively require some manner of periodic and on-going testing to monitor the population of cladding for breakaway resistance. More than 200 lots of production cladding material have been tested in accordance with the draft regulatory guidelines. Testing has been conducted in a steam environment at the critical temperature for breakaway oxidation for durations that exceed the analytical endurance limit required to comply with the breakaway oxidation test criteria. The alloys that have been tested include both ZIRLO cladding and Optimized ZIRLO cladding. Breakaway oxidation testing consisted of three basic steps: preparation of test specimens, high temperature steam oxidation and post-test specimen evaluation. The results show there is a high probability that all ZIRLO and Optimized ZIRLO lots will pass production certification testing. Variations in response to breakaway oxidation testing were observed only in testing that ran well beyond the maximum LOCA duration of 2000 seconds. No indications of early breakaway oxidation were observed in the testing of production material that has been completed thus far. This provides confidence that a sampling approach to breakaway oxidation testing and monitoring remains a sound approach.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Underground test coordination at the waste isolation pilot plant - 15229

Underground test coordination is a critical component of safe and efficient conduct of testing operations in a working underground research laboratory (URL). This is particularly important when planning and implementing large, multi-organizational field-scale test programs, when the URL is co-located with an operating repository, or when the host facility, such as the Waste Isolation Pilot Plant (WIPP), is recovering from off-normal events. As such, the Department of Energy Carlsbad Field Office developed an Integrated Project Team (IPT) charter in late 2013 establishing the WIPP underground Test Coordination Office (TCO). The IPT was established to ensure that underground science activities are coordinated, implemented, and managed in an integrated, consistent, efficient, cost-effective, safe, and environmentally compliant manner that maintains quality assurance standards. This is done while ensuring testing operations do not interfere with the WIPP's primary mission, the disposal of transuranic (TRU) waste, and at present, the recovery of WIPP operations. This paper reports the current status of the WIPP underground science and testing programs within the framework of the WIPP stabilization and recovery activities and describes the role of the TCO for current activities as well as for the long-term success of an underground research laboratory. As a result of the underground fire and radiological incident of early February 2014, during this recent period of WIPP recovery, the TCO is ensuring the requirements of the scientific programs are met and that work activities are planned and implemented in compliance with enhanced work control processes and corrective actions imposed at WIPP. This paper addresses the impacts of the accidents at WIPP on the many science experiments that were in process when the events occurred. It presents the plans for their recovery in concert with WIPP's recovery plans, and summarizes the impacts of new underground processes and procedures that will be imposed on the science work as a result. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrated soft snake robot for gamma spectroscopy of radiologically contaminated ducting

Anticipated growth in the number and complexity of nuclear facilities entering the decommissioning phase of their lifespan requires innovative methods of mitigating radiological and safety hazards for workers. Advancements in robotics provide opportunities for remote characterization of radiologically contaminated ducts and pipes, reducing worker exposure. However, the nuclear decommissioning industry has shown a hesitancy in adopting new technology due to concerns regarding capital costs and a lack of demonstration data in representative environments. This work aims to leverage novel soft robotics to develop and demonstrate a sensor-integrated characterization tool for contaminated ducting systems. Two gamma spectrometers – one scintillation-based and one solid-state – were selected and integrated into a pneumatically-actuated snake-like soft robot using stretchable electronic cabling. The robot was then demonstrated at the Idaho National Laboratory’s Critical Infrastructure Test Range Complex. The robot maneuvered through a pseudo-constrained corridor containing several sealed sources and the integrated spectrometers collected spectra at various points along the path of travel. Both spectrometers successfully collected spectra with identifiable, isotope-specific peaks. To evaluate the effect of contamination buildup on the collected spectra, the robot with the integrated scintillation detector was tested using a liquid radioactive source. The resulting spectra showed little detection interference from the liquid contamination; however, a short-lived isotope was used which may not be representative of longer-lived contamination.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Integral Experiment Request 230 CED-2 Summary Report

A method is described to test the effect of increased moderation on the 7uPCX critical arrays using the existing assembly hardware. The proposed experiments will allow the exploration of the assembly fuel-to-water ratio out to, and possibly beyond, optimum moderation in the assembly. A significant result reported below is that the total uncertainty in the benchmark k eff in some of these experiments is reduced by about a factor of two compared to the uncertainties obtained in the fully-reflected experiments done to date.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

HYDRODYNAMIC TESTING OF ZIRCALOY TO STEEL HUB COUPLINGS FOR USE IN ADVANCED TEST REACTOR I-LOOP TUBE

The ATR I-positions' isolation from the flux trap region provides an opportunity for a test facility that could create conditions representative of commercial light water reactors. Such a facility requires piping couplings and joints that withstand extreme thermal and pressure cycling. Also, transitioning from steel to zircaloy piping inside the reactor vessel allows the neutronic properties of zircaloy to be leveraged while using cost-effective stainless steel outside of the core. Grayloc-style hub couplings will act as transition points between stainless steel piping and zircaloy piping inside the reactor vessel. These couplings have not been sufficiently tested for leakage where there is a transition between materials. This transition is a concern because the thermal expansion coefficients of the materials differ. Seal integrity between the two components may be greatly affected by thermal expansion at the connection. Thus, the effect of thermal cycling must be assessed. Thermal and pressure cycling and hydrodynamic testing will be conducted to verify seal integrity of the steel to zircaloy hub coupling when subjected to ATR conditions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Tomographic Analysis of SRF Cavities as Asymmetric Plasma Reactors

The tomographic reconstruction of local plasma parameters for nonequilibrium plasma sources is a developing approach, which has a great potential in understanding the fundamental processes and phenomena during plasma processing of SRF cavity walls. Any type of SRF cavity presents a plasma rector with limited or distorted symmetry and possible presence of high gradients. Development of the tomographic method for SRF plasma analysis consists of several steps. First, we define the method based on the inversion of the Abel integral equation for a hollow spherical reactor. Second step is application of the method for the actual elliptical cavity shape. Third step consists of study of the effects of various shapes of the driven electrode. Final step consists of testing the observed line-integrated optical emission data. We will show the typical results in each step and the final result will be presented in the form of correlation between local plasma parameter distributions and local etching characteristics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pilot-Scale Silicone Process for Low-Cost Carbon Dioxide Capture. Final Scientific/Technical Report

GE Global Research has developed, over the last 8 years, a platform of cost effective CO 2 capture technologies based on a non-aqueous aminosilicone solvent (GAP-1m). As demonstrated in a previous funded DOE project (DE-FE0007502), the GAP-1m solvent has increased CO 2 working capacity, lower volatility and corrosivity than the benchmark aqueous amine technology. The current report describes the cooperative program between GE Global Research (GE GRC), and the National Carbon Capture Center (NCCC) to design, construct, and operate a pilot-scale process using GAP-1m solvent to demonstrate its performance at 0.5 MWe. (i) Performance of the GAP-1m solvent was demonstrated in a 0.5 MWe pilot with real flue gas for over 900 hrs. of operation using two alternative desorption designs: a Continuous Stirred Tank Reactor (CSTR), and a Steam Stripper Column (SSC). The CSTR is a one-stage separation unit with reduced space requirements, and capital cost. The alternative is a multi-stage separation column, with improved desorption efficiency. Testing the two desorber options allowed us to identify the most cost effective, and space efficient desorber solution. (ii) CSTR Campaign: The CSTR desorber unit was designed, fabricated and integrated with the pilot solvent test unit (PSTU), replacing the PSTU Steam Stripper Column at NCCC. Solvent management and waste water special procedures were implemented to accommodate operation of the non-aqueous solvent in the PSTU. Performance of the GAP-1m solvent with the CSTR was demonstrated for over 500 hrs. while varying temperature of the desorption (230 – 265 oF), solvent circulation rate (GAP-1m : CO 2 (molar) = 1.5 – 4), and flue gas flow rates (0.2 – 0.5 MWe). Solvent carry-over in the CO 2 product was minimized by maintaining water content below 5 wt.%, and desorption pressure at 7 psig. CO 2 capture efficiency achieved was 95% at 0.25 MWe (GAP-1m : CO 2 = 4 (molar), 230 oF desorption), and 65% at 0.5 MWe (GAP-1m : CO 2 (molar) = 1.5, 248 oF). Solvent loss was dominated by thermal degradation of the rich solvent. (iii) Steam Stripper Column Campaign: Higher expected cost of the solvent vs. aqueous amines makes solvent management a top priority to maintain the low cost for the process. During the testing of the GAP-1m solvent with the CSTR, thermal degradation of the rich solvent was found to be the main mechanism in solvent loss. Small amounts of water in the working solution were found to be an effective way to enable steam stripping, thereby lowering desorption temperature, and hence reducing thermal degradation. Steam stripping also increased working capacity by 30% due to a more efficient desorption. The concept was first tested in a glass stripping column (lab scale, GE GRC), optimized in a continuous bench scale system (2 kWe, GE GRC), and demonstrated in a 0.5 MWe PSTU at NCCC. No special system modifications were required to the PSTU to accommodate the testing of the non-aqueous GAP-1 solvent with the regenerator column. SSC was found to be more robust towards solvent entrainment (H 2 O < 35 wt.%). 90 – 95% CO 2 capture efficiency was achieved under stoichiometric conditions at 0.5 MWe (235 oF desorption, 2 psig and 19 wt. % H 2 O). Both CO 2 capture efficiency and specific duty reached optimum conditions at 18 wt.% H 2 O. Low amine degradation (< 0.05 wt.%/day) was recorded over 350 hrs. of operation. Controlled water addition to GAP-1m solvent decreased the desorption temperature, thermal degradation, and improved the CO 2 working capacity due to more efficient absorption and desorption processes. Under these conditions, the GAP-1m solvent exhibited a 25% increased working capacity, and 10% reduction in specific steam duty vs. MEA, at 10 oF lower desorption temperature. (iv) Techno-economic Analysis: The pilot-scale PSTU engineering data were used to update the capture system process models, and the techno-economic analysis was performed for a 550 MW coal fired power plant. The 1st year CO 2 removal cost for the aminosilicone-based carbon-capture process was evaluated at $48/ton CO 2 using the steam stripper column. This is a 20% reduction compared to MEA, primarily due to lower overall capital cost. CO 2 cost using the CSTR desorber is dominated by the economics of the solvent make-up. The steam stripper desorber is the preferred unit operation due to a more efficient desorption, and reduced solvent make-up rate. Further reduction in CO 2 capture cost is expected by lowering the manufacturing cost of the solvent, implementing flowsheet optimization and/or implementing the next generation aminosilicone solvent with improved stability and increased CO 2 working capacity.

0.5 MW Pilot↗

Final Report Integrated DM1200 Melter Testing Using AZ-102 and C-106/AY-102 HLW Simulants: HLW Simulant Verification

The principal objectives of the DM1200 melter tests were to determine the effects of feed rheology, feed solid content, and bubbler configuration on glass production rate and off-gas system performance while processing the HLW AZ-101 and C-106/AY-102 feed compositions; characterize melter off-gas emissions; characterize the performance of the prototypical off-gas system components, as well as their integrated performance; characterize the feed, glass product, and off-gas effluents; and perform pre- and post test inspections of system components. The specific objectives (including test success criteria) of this testing, along with how each objective was met, are outlined in a table.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Plug-in Electric Vehicle Charging Response Characterization for Grid Integration: Implications for Smart Charge Management

The rapid expansion of plug-in electric vehicles (PEVs) has created a unique challenge for electrical grids due to their significant power demand. At the same time, PEVs also create a unique opportunity to ease their own burden on the power grid, as they create a growing fleet of distributed energy resources capable of providing grid services such as demand response, frequency regulation, and renewable balancing. For aggregators and grid operators to effectively integrate PEVs into grid management, it is essential to first understand and characterize how they would respond in such situations. This study examines 25 models of PEVs across 25 makes, spanning model years from 2013 to 2025, to characterize their responses to the basic controls used in vehicle-grid integration (VGI): stopping, starting, and modulating the charge rate. Each vehicle was tested in a controlled laboratory setting to evaluate its performance in response to varying the maximum allowable current via the SAE J1772 control pilot signal, as well as its response to wake-up commands outlined in SAE J1772. Results show measurable differences across vehicle makes in the accuracy, latency, and precision with which PEVs respond to changes in ampacity, as well as varying sleep and wake-up behavior. The test results show that all vehicles respond to changes in ampacity, though with varying accuracy, precision, latency, and resolution. Wake-up behavior also differs across makes and models. These findings indicate that effective grid integration strategies must account for these differences. The results provide a foundation for understanding current vehicle behavior and advancing smart-charging methods while also highlighting the need for further testing, broader standardization, and manufacturer collaboration to ensure the successful integration of PEVs into the electrical grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Transverse Space Charge effects in IOTA with pyORBIT

The role and mitigation of space charge effects are important aspects of the beam physics research to be performed at the Integrable Optics Test Accelerator (IOTA) at Fermilab. The impact of nonlinear integrability (partial and complete) on space charge driven incoherent and coherent resonances will be a new feature of this accelerator and has the potential to influence the design of future low energy proton synchrotrons. In this report we model transverse space charge effects using the PIC code pyORBIT. First we benchmark the single particle tracking results against MADX with checks on symplecticity, tune footprints, and dynamic aperture in a partially integrable lattice realized with a special octupole string insert. Our space charge calculations begin with an examination of the 4D symplecticity. Short term tracking is done first with the initial bare lattice and then with a matching of the rms values with space charge. Next, we explore slow initialization of charge as a technique to establish steady state and reduce emittance growth and beam loss following injection into a mismatched lattice. We establish values of space charge simulation parameters so as to ensure numerical convergence. Finally, we compare the simulated space charge induced tune shifts and footprints against theory.

43 PARTICLE ACCELERATORS↗

Thermal modulation of nonlinear ultrasonic waves for nondestructive evaluation of elastic materials

Temperature variation is often considered an undesirable factor in ultrasonic testing, as wave velocity is highly sensitive to thermal fluctuations. However, completely eliminating the temperature effect is difficult, particularly in tests requiring precise velocity measurements. Recently, a method called Thermal Modulation of Nonlinear Ultrasonics (TMNL) has been developed. Instead of eliminating the thermal effect, the TMNL method leverages the temperature variation as a driving force to stimulate the nonlinear response of the medium and modulate the ultrasonic waves propagating in it. These modulated waves can then be used to evaluate the nonlinear behaviours of the test medium. This paper presents a focused review of the TMNL technique, including its theoretical foundations, particularly the conceptual challenges in integrating thermal effects into classical acoustoelastic theory, and recent applications in non-destructive evaluation (NDE). Three case studies are presented to demonstrate TMNL’s application in detecting microcracking in concrete, assessing ageing in polymer materials, and enabling temperature compensation in acoustoelastic tests. In conclusion, the review also summarises related studies, including photothermal crack modulation, and discusses current limitations and future directions of TMNL in elastic media.

NDE↗

Model validation using CFD-grade experimental database for NGNP Reactor Cavity Cooling Systems with water and air

This project has been focused on the experimental and numerical investigations of the water-cooled and air-cooled Reactor Cavity Cooling System (RCCS) designs. At this aim, we have leveraged an existing experimental facility at the University of Wisconsin-Madison (UW), and we have designed and built a separate effect test facility at the University of Michigan. The experimental facility at UW has underwent several upgrades, including the installation of advanced instrumentation (i.e. wire-mesh sensors) built at the University of Michigan. These provides highresolution time-resolved measurements of the void-fraction distribution in the risers of the water-cooled RCCS facility. A phenomenological model has been developed to assess the water cooled RCCS system stability and determine the root cause behind the oscillatory behavior that occurs under normal two-phase operation. Testing under various perturbations to the water-cooled RCCS facility have resulted in changes in the stability of the integral system. In particular, the effects on stability of inlet orifices, water tank volume have and system pressure been investigated. MELCOR was used as a predictive tool when performing inlet orificing tests and was able to capture the Density Wave Oscillations (DWOs) that occurred upon reaching saturation in the risers. The experimental and numerical results have then been used to provide RCCS design recommendations. The experimental facility built at the University of Michigan was aimed at the investigation of mixing in the upper plenum of the air-cooled RCCS design. The facility has been equipped with state-of-theart high-resolution instrumentation to achieve so-called CFD grade experiments, that can be used for the validation of Computational Fluid Dynanmics (CFD) models, both RANS (Reynold-Averaged) and LES (Large Eddy Simulations). The effect of risers penetration in the upper plenum has been investigated as well.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗