At least 163 records · Page 9

Noise from Supersonic Coaxial Jets: Inverted Velocity Profile - Part 3

The instability wave noise generation model is used to study the instability waves in the two shear layers of an inverted velocity profile, supersonic, coaxial jet and the noise radiated from the dominant wave. The inverted velocity profile jet has a high speed outer stream surrounding a low speed inner stream and the outer shear layer is always larger than the inner shear layer. The jet mean flows are calculated numerically. The operating conditions are chosen to exemplify the effect of the coaxial jet outer shear layer initial spreading rates. Calculations are made for the stability characteristics in the coaxial jet shear layers and the noise radiated from the instability waves for different operating conditions with the same total thrust, mass flow and exit area as a single reference jet. Results for inverted velocity profile jets indicate that relative maximum instability wave amplitudes and far field peak noise levels can be reduced from that of the reference jet by having higher spreading rates for the outer shear layer, low velocity ratios, and outer streams hotter than the inner stream.

Dahl, Milo D.↗

Suspended Patch Antenna Array With Electromagnetically Coupled Inverted Microstrip Feed

The paper demonstrates a four-element suspended patch antenna array, with a parasitic patch layer and an electromagnetically coupled inverted microstrip feed, for linear polarization at K-Band frequencies. This antenna has the following advantages over conventional microstrip antennas: First, the inverted microstrip has lower attenuation than conventional microstrip; hence, conductor loss associated with the antenna corporate feed is lower resulting in higher gain and efficiency. Second, conventional proximity coupled patch antennas require a substrate for the feed and a superstrate for the patch. However, the inverted microstrip fed patch antenna makes use of a single substrate, and hence, is lightweight and low cost. Third, electromagnetic coupling results in wider bandwidth. Details regarding the design and fabrication will be presented as well as measured results including return loss, radiation patterns and cross-polarization levels.

Simons, Rainee N.↗

Minimizing Gravity Sag of a Large Mirror with an Inverted Hindle-Mount

A method of minimizing the optical distortion from gravity sag on a suspended large autocollimating flat mirror has been devised. This method consists of an inverted nine-point Hindle-Mount. A conventional Hindle-mount is located underneath a sky-viewing mirror and is primarily under compression loads from the weight of the mirror. It is not suitable for the situation where the mirror is viewing the ground, since a mirror would tend to fall out of the mount when in an inverted position. The inverted Hindle-Mount design consists of bonded joints on the backside of the mirror that allow the mirror to be held or suspended above an object to be viewed. This ability is useful in optical setups such as a calibration test where a flat mirror is located above a telescope so that the telescope may view a known optic.

Robinson, David W.↗

Motor/Generator and Inverter Characterization for Flywheel System Applications

The Advanced Electrical Systems Development Branch at NASA Glenn Research Center (GRC) has been involved in the research and development of high speed flywheels systems for satellite energy storage and attitude applications. These flywheels will serve as replacement for chemical nickel hydrogen, nickel cadmium batteries and gyroscopic wheels. The advantages of using flywheel systems for energy storage on satellites are high energy density, high power density, long life, deep depth of discharge, and broad operating temperature ranges. A flywheel system for space applications consist of a number of flywheel modules, the motor/generator and magnetic bearing, and an electronics package. The motor/generator electronics package includes a pulse-width modulated inverter that drives the flywheel permanent magnet motor/generator located at one end of the shaft. This summer, I worked under the direct supervision of my mentor, Walter Santiago, and the goal for this summer was to characterize motor generator and inverter attributes in order to increase their viability as a more efficient energy storage source for space applications. To achieve this goal, magnetic field measurements around the motor/generator permanent magnet and the impedance of the motor/generator three phase windings were characterized, and a recreation of the inverter pulse width modulated control system was constructed. The Flywheel modules for space use are designed to maximize energy density and minimize loss, and attaining these values will aid in locating and reducing losses within the flywheel system as a whole, making flywheel technology more attractive for use as energy storage in future space applications.

Tamarcus, Jeffries L.↗

FET commutated current-FED inverter

A shunt switch comprised of a field-effect transistor (Q.sub.1) is employed to commutate a current-fed inverter (10) using thyristors (SCR1, SCR2) or bijunction transistors (Q.sub.2, Q.sub.3) in a full bridge (1, 2, 3, 4) or half bridge (5, 6) and transformer (T.sub.1) configuration. In the case of thyristors, a tapped inverter (12) is employed to couple the inverter to a dc source to back bias the thyristors during commutation. Alternatively, a commutation power supply (20) may be employed for that purpse. Diodes (D.sub.1, D.sub.2) in series with some voltage dropping element (resistor R.sub.12 or resistors R.sub.1, R.sub.2 or Zener diodes D.sub.4, D.sub.5) are connected in parallel with the thyristors in the half bridge and transformer configuration to assure sharing the back bias voltage. A clamp circuit comprised of a winding (18) negatively coupled to the inductor and a diode (D.sub.3) return stored energy from the inductor to the power supply for efficient operation with buck or boost mode.

Rippel, Wally E.↗

Analysis of the Measurement and Modeling of a Digital Inverter Based on a Ferroelectric Transistor

The use of ferroelectric materials for digital memory devices is widely researched and implemented, but ferroelectric devices also possess unique characteristics that make them have interesting and useful properties in digital circuits. Because ferroelectric transistors possess the properties of hysteresis and nonlinearity, a digital inverter containing a FeFET has very different characteristics than one with a traditional FET. This paper characterizes the properties of the measurement and modeling of a FeFET based digital inverter. The circuit was set up using discrete FeFETs. The purpose of this circuit was not to produce a practical integrated circuit that could be inserted directly into existing digital circuits, but to explore the properties and characteristics of such a device and to look at possible future uses. Input and output characteristics are presented, as well as timing measurements. Comparisons are made between the ferroelectric device and the properties of a standard digital inverter. Potential benefits and possible uses of such a device are presented.

MacLeod, Todd C.↗

Switching Characteristics of Ferroelectric Transistor Inverters

This paper presents the switching characteristics of an inverter circuit using a ferroelectric field effect transistor, FeFET. The propagation delay time characteristics, phl and plh are presented along with the output voltage rise and fall times, rise and fall. The propagation delay is the time-delay between the V50% transitions of the input and output voltages. The rise and fall times are the times required for the output voltages to transition between the voltage levels V10% and V90%. Comparisons are made between the MOSFET inverter and the ferroelectric transistor inverter.

Laws, Crystal↗

Static Characteristics of the Ferroelectric Transistor Inverter

The inverter is one of the most fundamental building blocks of digital logic, and it can be used as the foundation for understanding more complex logic gates and circuits. This paper presents the characteristics of an inverter circuit using a ferroelectric field-effect transistor. The voltage transfer characteristics are analyzed with respect to varying parameters such as supply voltage, input voltage, and load resistance. The effects of the ferroelectric layer between the gate and semiconductor are examined, and comparisons are made between the inverters using ferroelectric transistors and those using traditional MOSFETs.

Mitchell, Cody↗

Failure Mode and Effects Analysis (FMEA) for Photovoltaic Inverter

Photovoltaic (PV) inverters are critical yet vulnerable components in modern energy systems, often acting as reliability bottlenecks that increase the levelized cost of energy (LCOE). To address this, this paper presents a comprehensive Failure Mode and Effects Analysis (FMEA) tailored for PV inverters. Leveraging field data and literature, we identify failure-prone components, such as capacitors,, and relays, and prioritize their risks based on quantitative Risk Priority Numbers (RPNs). The analysis reveals that surge-induced MOV short circuits, capacitor degradation, and environmental cooling fan failures dominate the risk profile. These findings provide a targeted framework for reliability improvement, guiding future efforts in predictive diagnostics, design optimization, and accelerated life testing strategies.

14 SOLAR ENERGY↗

A Twin Circuit Theory-Based Framework for Oscillation Event Analysis in Inverter-Dominated Power Systems With Case Study for Kaua‘i System

Here, this paper proposes a real-world oscillation event analysis framework for power systems that include inverter-based resources together with synchronous generators. Specifically, the proposed framework combines both measurement-and model-based techniques to readily identify potential oscillation sources, replay the oscillation event with numerical simulation, unveil the underlying oscillation mechanism, and suggest mitigation methods for a wide range of oscillation events. To strengthen the theoretical foundation of our analysis framework, this paper proposes a twin circuit theory that provides theoretical support for one key utilized but not well-proven measurement-based oscillation source identification method-Dissipating Energy Flow. Our twin circuit theory also shows that adopting well-tuned grid-forming inverters can be a potential mitigation method for oscillation events. Finally, the effectiveness of our proposed oscillation event analysis framework is demonstrated by addressing a real-world 18-20 Hz oscillation event in Kaua‘i's power system on November 21, 2021.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Generic and Multifunctional Electromagnetic Transient Model for Grid-Following Inverters

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, ate- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

14 SOLAR ENERGY↗

An Innovative Energy Management System for Microgrids with Multiple Grid-Forming Inverters: Preprint

As more and more grid-forming (GFM) inverter-based resources replace traditional fossil-fueled synchronous generators as the GFM sources in microgrids, the existing microgrid energy management systems (EMSs) need to be updated to control and coordinate multiple GFM inverters that consider system control objectives under different microgrid connection states. For each state, we formulate an optimization problem and apply a real-time feedback-based control algorithm; all together, the control algorithms seamlessly connect the states into a generic EMS. We showcase the EMS on a real-world simulation of a microgrid under the different states to demonstrate its operational effectiveness.

energy management system↗

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis: Preprint

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline- based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive- sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

grid following inverter↗

A Generic and Multi-Functional Electromagnetic Transient Model for Grid-Following Inverter: Preprint

This article presents a generic and multi-functional electromagnetic transient (EMT) dynamic model of grid following (GFL) inverter-based resource (IBR) using the PSCAD TM software platform. The features of the developed model includes the flexibility in selecting various types and combinations of DC sources covering PV modules, battery modules, ideal DC source module, as well as flexibility in selecting either switched or averaged model of inverter. This model also covers exhaustive lists of controller logic covering open-loop/closed-loop PQ dispatch control, DC voltage and AC terminal voltage control along with the conventional current control designed in dq-domain, aB- domain and positive-negative sequence domain. Moreover, this model is equipped with the flexibility in selecting various types of current limiting schemes that includes saturation-based as well as latching-based current limiter, anti-windup protection. Moreover, the EMT model is agnostic to the MVA rating and is suitable for interfacing transmission systems by being complaint with the IEEE Std. 2800. The generality in the power circuits and the multi-functional options in operation and control of the developed EMT model makes it suitable for both academia and industry to study various power system aspects not limited to but such as fault behavior of GFL IBR and impacts on protection system, transient stability of a system interfaced with large number of GFL IBRs etc.

grid following inverter↗

Why PV Inverter Failures May Lead to AC Power Quality Issues

Case study examines a common PV inverter failure that can drive uncommon issues in the field - namely, damage to the AC protection equipment from DC fault currents for short periods during transformer-less inverter power electronic failures.

14 SOLAR ENERGY↗

Controller Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System with Multiple Grid-Forming Inverters

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). The CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

A Faster-Than-Real-Time Framework for Reliability-Oriented Simulation of PV Inverters

Physics-of-Failure (PoF) based reliability assessment for photovoltaic (PV) inverters requires long-duration electrical and electrothermal stress histories, yet generating such stress histories with high-fidelity switching models over year long mission profiles is computationally prohibitive. Conventional methods either sacrifice modeling fidelity for speed or require runtimes that are impractical for design iteration and uncertainty studies. To address this bottleneck, this paper presents a High-Performance Computing (HPC) based simulation frame work for faster-than-real-time reliability-oriented simulation. The proposed framework integrates the Average-to-Switching (A2S) method with parallel computing techniques to accelerate switching-level waveform reconstruction. We further introduce optimization strategies, including cluster merging and sensitivity based mission profile screening, to reduce the computational burden. Evaluated using real-world mission profile inputs and a MATLAB/Simulink switching-model reference, the framework reduces the simulation time for a one-year mission from an intractable multi-year duration to approximately 7.3 minutes while maintaining low waveform error. This acceleration provides a practical reliability-oriented simulation engine that can be coupled with component-specific aging models for subsequent PV inverter PoF assessment.

High-performance Computing↗

Impedance Scan of Inverter-Based Resources and Diesel Generator for Stability Analysis

Impedance-based methods are widely used for power system stability analysis with inverter-based resources (IBRs), e.g., assessing dynamic interactions between the power grid and an IBR, control interactions between multiple IBRs, and the sub-synchronous oscillation and damping phenomenon. Since it is difficult to get a numerical model 100% matching with the hardware IBR, using the hardware inverter directly to obtain its output impedance has become a prominent approach nowadays. Therefore, this article presents the impedance scan using hardware IBRs, and also a hardware diesel generator as it still stays with the grid before the grid completely goes to renewable. The devices under test (DuTs) for the impedance scan includes two 3-..phi.., 480 V, 60 Hz commercial grid-forming IBRs (one of 250 kVA and another of 125 kVA rating) in series with ..delta..-Y transformers, one 3-..phi.., 480 V, 60 Hz commercial grid-following IBR (of 125 kVA rating), and a 3-..phi.., 480 V, 60 Hz commercial diesel generator (of 187.5 kVA rating). Using voltage signals perturbed with sub-, inter-, and higher harmonic components, and measuring the current response, the positive-sequence impedances are computed via an offline-based post-analysis. Moreover, best-fit transfer functions are estimated that closely resemble the measured data points of the positive-sequence impedances. Based on the observations from various outcomes of the hardware experiments, this article also provides some fundamental insights on the equivalent positive-sequence impedance of a combination of multiple hardware components by comparing the estimated and the empirically computed impedances. A comparative insight on the damping capability of the DuTs using the positive-sequence impedances of the hardware is also discussed.

current measurement↗