Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ion detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

The hidden ion population of the magnetosphere

The presence of a cold ion population in the magnetosphere which is normally hidden from particle detector observation by the positive charging of the spacecraft is reported. Ion and electron data were obtained from particle detectors on the ATS 6 and SCATHA satellites designed to measure the 1-eV to 80-keV plasma population. The cold, isotropic ion population, with temperature 1 eV and density 10-100/cu cm, was detected only when the spacecraft were in eclipse, when spacecraft potential had dropped from +10 V in sunlight to +4 to +5 V. The hidden ion population was found at geosynchronous altitude only during geomagnetically quiet times and when there has been an absence of geomagnetic activity for several hours, and appears to coexist with the plasma sheet. More consistent measurements of the cold ion population at midnight or at other local times would require the biasing of the ion detector with respect to the spacecraft, or the controlling of spacecraft potential.

Olsen, R. C.↗

Noctilucent cloud sampling by a multi-experiment payload.

Two multi-experiment payloads were launched into noctilucent cloud displays above Kiruna, Sweden, on the nights of July 31 and Aug. 1, 1971. The payloads were part of the continuing Pandora II cosmic dust collection series and included: (1) Pandora 2 dust collection with in-flight shadowing photoelectric polarimeters to measure scattered light at 4100 and 5400 A, a plasma detector and an ion probe, and piezoelectric microphones. These payloads attempted to investigate noctilucent clouds by four simultaneous and independent techniques. The photometric data indicate that the first payload passed through a cloud, while the second payload did not. These results are confirmed by the particle collection experiment which indicates a higher collection on the first payload. Analysis of the chemical composition of the collected particles indicates an unusual amount of high atomic number elements.

Hallgren, D. S.↗

The pick-up of cometary protons by the solar wind

The HERS detector of the Ion Mass Spectrometer on the Giotto spacecraft measured the 3 dimensional distribution of picked-up cometary protons over a distance of 6 million km upstream of the bow shock. The protons are elastically scattered out of their original cycloidal trajectories such that they are nonuniformly distributed over a spherical shell in velocity space. The shell thickness increases as the bow shock is approached. Inside the shock, the cometary protons are difficult to distinguish from the heated solar wind protons.

Neugebauer, M.↗

The pick-up of cometary protons by the solar wind

The HERS detector of the Ion Mass Spectrometer on the Giotto spacecraft measured the 3-dimensional distribution of picked-up cometary protons over a distance of about 8 million km upstream of the bow shock of comet P/Hally. The protons were observed to be elastically scattered out of their original cycloidal trajectories such that they were nonuniformly distributed over a spherical shell in velocity space. The shell radius (relative to its expected radius) and thickness increased as the bow shock was approached. Down-stream of the shock, the cometary protons could not be distinguished from the heated solar wind protons.

Neugebauer, M.↗

A silicone column for GC analysis of polar and nonpolar chemicals

The investigation of the Saturnian System is being proposed jointly by NASA and the European Space Agency (ESA). The mission is scheduled for a launch in 1996. The mission provides an opportunity for close observation and exploration of Saturn's atmosphere, the complex Saturnian System of satellites and rings, Titan (Saturn's planet-sized moon), and Saturn's magnetosphere. The mission gives special attention to Titan which is blanketed by a thick, opaque atmosphere. An atmospheric probe will be deposited into the Titan Atmosphere for in situ measurement during a slow, three hour descent to the surface. The results from this analysis may provide the information which is important to the research of chemical evolution, and the origin of life. An analytical system was developed as a part of the Titan Aerosol Gas Experiment (TAGEX), a proposed experiment for the Cassini Mission. This system will use two highly sensitive detectors, the Metastable Ionization Detector (MID) and the Ion Mobility Spectrometer (IMS). Unfortunately, when commercial columns are utilized with these highly sensitive detectors, volatile components continuously bleed from the column and interfere with the detector. In addition, light columns must be able to separate polar and nonpolar organic chemicals within 10-15 minutes under isothermal conditions for the Titan Mission. Therefore, a highly crosslinked silicone polymeric packed column was developed which is able to efficiently separate amines, alcohols, and hydrocarbons with retention times less that 15 minutes at 100 C isothermal condition.

Shen, T. C.↗

Experimenter's data package for the descending layers rocket

In response to a proposal from Science Applications International Corporation (SAIC), NASA Headquarters has approved a sounding rocket mission designed to study the physics of intermediate layers in the Earth's ionosphere at middle latitudes. The experiment will be carried out by a team of scientists and engineers from the NASA Wallops Flight Facility, SAIC, the NASA Goddard Space Flight Center, and the Millstone Hill radar observatory. The mission will involve the launch of an instrumented sounding rocket from the Wallops Island rocket range in the summer of 1994, with the objective of penetrating a descending ionized layer in the E-region between altitudes of 115 and 140 km. Instrumentation aboard the rocket will measure the ion and neutral composition of the layer, its plasma density, driving wind and electric field forces, the thermal ion distribution function, and electron temperature. Depending on payload weight constraints and subject to availability, a particle detector to measure energetic ion and/or electron fluxes near the layer may also be included. This document was prepared as a reference for the NASA payload development and experiment teams, for distribution at the Project Initiation Conference (PIC). The design specifications discussed herein are therefore of a preliminary nature; the intent is to promote open discussions between experimenters and NASA engineers that will lead to a final design capable of achieving the experiment objectives.

Earle, Greg↗

Aqueous nitrite ion determination by selective reduction and gas phase nitric oxide chemiluminescence

An improved method of flow injection analysis for aqueous nitrite ion exploits the sensitivity and selectivity of the nitric oxide (NO) chemilluminescence detector. Trace analysis of nitrite ion in a small sample (5-160 microL) is accomplished by conversion of nitrite ion to NO by aqueous iodide in acid. The resulting NO is transported to the gas phase through a semipermeable membrane and subsequently detected by monitoring the photoemission of the reaction between NO and ozone (O3). Chemiluminescence detection is selective for measurement of NO, and, since the detection occurs in the gas-phase, neither sample coloration nor turbidity interfere. The detection limit for a 100-microL sample is 0.04 ppb of nitrite ion. The precision at the 10 ppb level is 2% relative standard deviation, and 60-180 samples can be analyzed per hour. Samples of human saliva and food extracts were analyzed; the results from a standard colorimetric measurement are compared with those from the new chemiluminescence method in order to further validate the latter method. A high degree of selectivity is obtained due to the three discriminating steps in the process: (1) the nitrite ion to NO conversion conditions are virtually specific for nitrite ion, (2) only volatile products of the conversion will be swept to the gas phase (avoiding turbidity or color in spectrophotometric methods), and (3) the NO chemiluminescence detector selectively detects the emission from the NO + O3 reaction. The method is free of interferences, offers detection limits of low parts per billion of nitrite ion, and allows the analysis of up to 180 microL-sized samples per hour, with little sample preparation and no chromatographic separation. Much smaller samples can be analyzed by this method than in previously reported batch analysis methods, which typically require 5 mL or more of sample and often need chromatographic separations as well.

NASA Discipline Environmental Health↗

A model of the ion wake of Mars

Observations from the Phobos spacecraft suggest that, for the most part, the Martian magnetotail is induced instead of intrinsic. Test particle techniques are used to determine how the associated ion wake might appear to detectors behind Mars if it is produced primarily by planetary ions picked up by the solar wind in the dayside exosphere. The results suggest that low energy pickup ions populate the inner wake, while a more energetic component is present in the outer magnetosheath and adjacent solar wind.

Luhmann, J. G.↗

The hidden ion population - Revisited

In an investigation conducted by Olsen (1982) on the basis of particle data taken with an electrostatic analyzer, it was found that a cold plasma population with a density between 10 and 100 per cu cm appeared suddenly when the satellite was eclipsed, but was hidden in sunlight. The present paper has the objective to show further measurements of ordinarily 'hidden' ion populations, in order to resolve some of the questions raised in connection with the Scatha satellite data reported by Olsen. It is found that the retarding ion mass spectrometer (RIMS) detector is capable of measuring the core of the plasma distribution in sunlight and eclipse, though the task is more easily done in eclipse. There are, however, limitations concerning the ability of the detector to measure all the plasma, all the time. It is, therefore, pointed out that continuous effective measurements of the 'hidden' ion population of the magnetosphere still awaits satellites with effective means of potential control.

Olsen, R. C.↗

In Situ Geochemical Analysis and Age Dating of Rocks Using Laser Ablation-Miniature Mass Spectrometer

A miniaturized instrument for performing chemical and isotopic analysis of rocks has been developed. The rock sample is ablated by a laser and the neutral species produced are analyzed using the JPL-invented miniature mass spectrometer. The direct sampling of neutral ablated material and the simultaneous measurement of all the elemental and isotopic species are the novelties of this method. In this laser ablation-miniature mass spectrometer (LA-MMS) method, the ablated neutral atoms are led into the electron impact ionization source of the MMS, where they are ionized by a 70-eV electron beam. This results in a secondary ion pulse typically 10-100 microsecond wide, compared to the original 5-10-nanosecond laser pulse duration. Ions of different masses are then spatially dispersed along the focal plane of the magnetic sector of the miniature mass spectrometer and measured in parallel by a modified CCD (charge-coupled device) array detector capable of detecting ions directly. Compared to conventional scanning techniques, simultaneous measurement of the ion pulse along the focal plane effectively offers a 100% duty cycle over a wide mass range. LAMMS offers a more quantitative assessment of elemental composition than techniques that detect laser-ionized species produced directly in the ablation process because the latter can be strongly influenced by matrix effects that vary with the structure and geometry of the surface, the laser beam, and the ionization energies of the elements. The measurement of high-precision isotopic ratios and elemental composition of different rock minerals by LAMMS method has been demonstrated. The LA-MMS can be applied for the absolute age determination of rocks. There is no such instrument available presently in a miniaturized version that can be used for NASA space missions. Work is in progress in the laboratory for geochronology of rocks using LA-MMS that is based on K-Ar radiogenic dating technique.

Sinha, Mahadeva P.↗

Global Geospace Science (GGS)/POLAR Thermal Ion Dynamics Experiments (TIDE) Co-Investigator Program: Mission Operations and Data Analysis (MO/DA)

We have pursued several investigations using the Polar/TIDE data set. The first was a comparison of TIDE high-altitude observations with similar ion flux signatures in the Los Alamos National Laboratory (LANL) magnetospheric plasma analyzer (MPA) data. There are several geosynchronously orbiting satellites with LANL MPA instruments onboard. When the satellite is immersed in fresh plasma sheet electrons, the spacecraft voltage drops to several hundred volts negative, and cold ions are accelerated in to the detector. In the LANL MPA spectrograms, the accelerated cold ions appear as a bright, narrow line, following the voltage of the spacecraft. This "ion line" is seen regularly on the nightside, but has not received much attention. The Polar TIDE observations indicated a ubiquitous "lobal wind" in the near-- magnetotail, a field-aligned stream of approx. 100 eV ions flowing out of both polar ionospheres. The interesting result of this research is that the MPA ion line is also peaked in the field-aligned direction, even though the potential well should be uniform in all directions. It is believed that this is evidence that the lobal winds not only populate the high-latitude lobes, but fill the lobes all the way in to the near-Earth plasma sheet (the location of geosynchronous orbit). This activity developed into a full-scale survey of the lobal wind observations in the TIDE database. The universality of these observations with respect to local time and solar wind conditions implies that the ionospheric outflow is supplying the near-Earth plasma sheet at all times, regardless of magnetic activity. We have conducted a statistical study of the characteristics of the lobal wind in these two data sets FIDE and LANL MPA), finding much similarity between them. Using these characteristics as input conditions to our inner magnetosphere ion transport model, we have conducted simulations of the flow of these particles inside of geosynchronous orbit to show the impact these particles will have on the near-Earth space environment. As the study has progressed, these results have been presented several times to the TIDE team during teleconferences. It is planned to present this survey at the GEM 2004 Summer Workshop, and hopefully at additional conferences in the near future. We are presently writing a paper on the lobal wind occurrence statistics, which should be submitted in April or May to the Journal of Geophysical Research for publication. An undergraduate student at the University of Alabama in Huntsville, Will Maddox, working at NASA MSFC with Dr. Paul Craven, is presently creating a database of the values TIDE moments for the lobal wind (under Dr. Liemohn's guidance), and this will be the focus of a follow-on paper.

Nagy, Andrew↗

Potential for Measurement of Trace Volatile Organic Compounds in Closed Environments Using Gas Chromatograph/Differential Mobility Spectrometer

For nearly 3.5 years, the Volatile Organic Analyzer (VOA) has routinely analyzed the International Space Station (ISS) atmosphere for a target list of approximately 20 volatile organic compounds (VOCs). Additionally, an early prototype of the VOA collected data aboard submarines in two separate trials. Comparison of the data collected on ISS and submarines showed a surprising similarity in the atmospheres of the two environments. Furthermore, in both cases it was demonstrated that the VOA data can detect hardware issues unrelated to crew health. Finally, it was also clear in both operations that the VOA s size and resource consumption were major disadvantages that would restrict its use in the future. The VOA showed the value of measuring VOCs in closed environments, but it had to be shrunk if it was to be considered for future operations in these environments that are characterized by cramped spaces and limited resources. The Sionex Microanalyzer is a fraction of the VOA s size and this instrument seems capable of maintaining or improving upon the analytical performance of the VOA. The two design improvements that led to a smaller, less complex instrument are the Microanalyzer s use of recirculated air as the gas chromatograph s carrier gas and a micromachined detector. Although the VOA s ion mobility spectrometer and the Microanalyzer s differential mobility spectrometer (DMS) are related detector technologies, the DMS was more amenable to micromachining. This paper will present data from the initial assessment of the Microanalyzer. The instrument was challenged with mixtures that simulated the VOCs typically detected in closed-environment atmospheres.

Limero, Thomas↗

Rocket and laboratory studies in astronomy

This report covers the period from September 1, 1992 to August 31, 1993. During the reporting period we launched the Faint Object Telescope to measure absolute fluxes of two hot dwarf stars in the spectral range below 1200 A. Although all systems worked normally, a higher than anticipated pressure in the detector led to ion-feedback that masked the useable data from the source. We have identified the source of the problem and are preparing for a reflight in the Fall of 1993. Our laboratory program for the evaluation of the ultraviolet performance of charge-coupled-detector (CCD) arrays continued with the aim of including a UV-sensitive CCD in a payload to be flown in 1994, and we have begun the assembly of this payload. Work has continued on the analysis of data from previous rocket experiments and from the UVX experiment which flew on STS-61C in January 1986.

Feldman, P. D.↗

On purported observations of partially ionized galactic cosmic rays

Galactic cosmic rays are generally believed to be bare nuclei, fully stripped of all orbital electrons during passage through several g/sq cm of interstellar matter. Over the years there have been numerous reports of so-called 'below-cutoff' Fe-group cosmic rays, with momentum below the minimum required for a fully ionized particle to reach Earth's inner magnetosphere. These reports comprised just a few tens of ions, but stimulated much speculation about partially ionized Galactic cosmic rays, suggesting a nearby source of Galactic cosmic rays. In this Letter we compare these previous reports to new observations of below-cutoff Fe-group ions from passive track detectors exposed for nearly 6 years in low-Earth orbit aboard NASA's Long Duration Exposure Facility (LDEF) satellite. The LDEF fluxes are only a few percent of the previously reported fluxes. This comparison suggests that the flux of below-cutoff ions must be out of phase with the observed solar-cycle variation of other (nonsolar) cosmic-ray sources and/or must strongly increase with decreasing altitude in low-Earth orbit. Both of these features are inconsistent with the notion of partially ionized Galactic cosmic rays as the source of the observed below-cutoff ions.

Tylka, A. J.↗

First Results From the Gas Chromatograph Mass Spectrometer (GCMS) Experiment on the Cassini-Huygens Probe

The Huygens Probe of the Cassini Huygens Mission entered the atmosphere of the moon Titan on January 14,2005. The GCMS was part of the instrument complement on the Probe to measure in situ the chemical composition of the atmosphere during the probe descent and to support the Aerosol Collector Pyrolyser (ACP) experiment by serving as detector for the pyrolization products. The GCMS employed a quadrupole mass filter with a secondary electron multiplier detection system and a gas sampling system providing continuous direct atmospheric composition measurements and batch sampling through three gas chromatographic (GC) columns. The mass spectrometer employed five electron impact ion sources with available electron energies of either 70 or 25 eV. Three ion sources served as detectors for the GC columns and two were dedicated to direct atmosphere sampling and ACP gas sampling, respectively. The GCMS gas inlet was heated to prevent condensation, and served to evaporate surface constituents after impact.

Niemann, Hasso B.↗

Ion Outflow Observations

The characteristics of out-flowing ions have been investigated under various circumstances. In particular the upwelling of ions from the cleft region has been studied to attempt to look at source characteristics (e.g., temperature, altitude). High altitude (6-8 Re) data tend to show ions species that have the same velocity and are adiabatically cooled. Such ions, while representative of their source, can not provide an accurate picture. Ion observations from the TIDE detector on the Polar spacecraft show an energy (or equivalently a velocity) spectrum of ions as they undo the geomagnetic mass spectrometer effect due to convection-gravity separation of the different species. Consolidation of this type of data into a complete representation of the source spectrum can be attempted by building a set of maximum-phase-space- density-velocity pairs and attributing the total to the source.

Mellot, Mary↗