At least 163 records · Page 9

A Short-Lived Isotope Counting System (SLICS) to measure reaction cross sections producing light, beta-decaying nuclei on OMEGA

A new activation detector optimized for short-lived isotopes was designed, installed, and tested on OMEGA. The Short-Lived Isotope Counting System (SLICS) can be positioned as close as 35 cm from the OMEGA target chamber center in a ten-inch-manipulator. Stable target samples can be mounted on the front end of the detector assembly to undergo triton-, deuteron-, or neutron-induced reactions that produce short-lived reaction products that beta decay. The emitted betas are detected in a phoswich configuration to eliminate the gamma background. The detector is optimized for isotopes with half-lives from 150 ms to 20 s, filling a gap in OMEGA’s current activation detectors for isotopes with half-lives >5 min. In a pilot study, SLICS achieved an efficiency of 24.5% ± 2.0% for counting 8Li, with a total of 505.8 ± 4.4 qualifying events. Using the existing triton laser-ion acceleration platform on OMEGA, this detector can be used to measure rarely studied tritium-induced reactions on light nuclei with an estimated uncertainty of 12%. As a result, the design of the detector and its performance during a first experiment employing deuterium as a surrogate will be discussed.

Beta spectrometry↗

Intelligent Experiments Through Real-time AI: Fast Data Processing and Autonomous Detector Control for sPHENIX and Future EIC Detectors (Final Report)

The overall vision of this project was to integrate real-time artificial intelligence (AI) directly into the data acquisition and detector-control systems of nuclear physics experiments, including both fast online event selection and an autonomous detector-control feedback loop. The work carried out under the award focused on the fast online event-selection half of that vision: the efficient recording of low-momentum heavy-flavor (HF) hadron decays in proton-proton collisions at the sPHENIX experiment at the Relativistic Heavy Ion Collider (RHIC)—an observable that requires fast tracking and topological trigger selection not previously demonstrated at RHIC, and that is essential for QCD studies at future facilities such as the Electron-Ion Collider (EIC). The autonomous detector-control (GPU-based feedback) component named in the project title remained a design concept and was not implemented under this award. The Massachusetts Institute of Technology (MIT) group led the offline simulation and data processing needed to train the machine-learning (ML) models, the translation of trained models to Field-Programmable Gate Array (FPGA) firmware using the hls4ml framework, and the physics validation of heavy-flavor reconstruction. Over the award period, the team developed and hardware-tested the principal components of an AI-based heavy-flavor trigger on simulated and recorded sPHENIX tracker data: a software Bipartite Graph Attention Network (BiGAT) trigger model reaching > 95% signal efficiency at 99% background rejection; an FPGA-native hit clusterizer matching the offline clustering; smaller networks synthesized to FPGA within the required sub-10 µs latency; and an assembled decoder–clusterizer–inference firmware chain exercised on the FELIX readout board. A complete, fully integrated hardware demonstrator was not finished within the award period. This report documents the project goals, the MIT group’s contributions, the technical accomplishments, and the outlook toward applications at the future EIC ePIC detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast spark-detection system for GEM detectors

The sPHENIX experiment is currently under commissioning at the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Lab (BNL). The Time Projection Chamber (TPC) serves as a tracking detector for the experiment. The sPHENIX TPC uses a stack of four Gas Electron Multipliers (GEMs) as a gain stage in a reduced ion back-flow configuration. To mitigate the damaging effects of sparks in the GEMs, an online spark monitoring system was created. Once the system detects a spark in a GEM stack, the voltages across the GEMs in that stack can be lowered to prevent further sparking without affecting the gain and efficiency of the other modules. Spark signals are coupled out of the GEM stack by a pick-off capacitor attached to the bottom of the bottom GEM. Custom PCBs convert the oscillatory spark signal into a mono-polar pulse that is then digitized. The software then saves the waveform in a server and uses experimentally derived thresholds to determine how to react. As a result, the system has so far proven to be effective at improving the stability of the TPC and preventing damaging events while collecting cosmic ray data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-Dimensional Projected-Momentum Covariance Mapping for Coulomb Explosion Imaging

We introduce projected-momentum covariance mapping, an extension of recoil-frame covariance mapping for 2D ion imaging studies. By considering the two-dimensional projection of the ion momenta as recorded by the detector, one opens the door to a complex suite of analysis tools adapted from three-dimensional momentum imaging studies. This includes the use of different frames of reference to unravel the dynamics of fragmentation and the application of fragment momentum constraints to isolate specific fragmentation channels. The technique is demonstrated on data from a two-dimensional ion imaging study of the Coulomb explosion of the cis and trans isomers of 1,2-dichloroethene, following strong-field ionization by an intense near-infrared femtosecond laser pulse. Classical simulations are used to guide the interpretation of projected-momentum covariance maps. The results offer a detailed insight into the distinct Coulomb explosion dynamics for this pair of isomers and lay the groundwork for future time-resolved studies of photoisomerization dynamics in this molecular system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Performance of the AstroPix Prototype Module for the Barrel Imaging Calorimeter at the ePIC Detector and in Space-Based Payloads

AstroPix is a high-voltage CMOS (HV-CMOS) monolithic active pixel sensor originally developed to enable precision gamma-ray imaging and spectroscopy in the medium-energy regime (~100 keV–100 MeV) based on the groundwork laid by ATLASpix and MuPix. It features a 500 μm pixel pitch, in-pixel amplification and digitization, and low power consumption (~3-4 mW/cm2), making it scalable for large-area, multilayer telescope detector planes. The detectors have a designed dynamic range of 25 keV to 700 keV. With these features, AstroPix meets the requirements of future space-based high-energy telescopes and the imaging layers of the Barrel Imaging Calorimeter (BIC) in the Electron-Proton/Ion Collider (ePIC) detector at the future Electron-Ion Collider (EIC). For the space-based payload, AstroPix is being integrated into sounding rocket and balloon payloads to demonstrate the technical readiness of the devices. For BIC, AstroPix-based imaging layers interleaved within the lead/scintillating-fiber (Pb/SciFi) sampling calorimeter provide granular shower imaging, enabling key performance features such as electron/pion or gamma/neutral pion separation. As part of the ongoing detector R&D efforts, we have been testing various AstroPix_v3 configurations: the single chip, a quad-chip assembly, a three-layer stack of quad chips, and a 9-chip module that represents the smallest prototype unit of the BIC imaging layer. This presentation will highlight recent performance test results from these AstroPix detector configurations.

Kim, Bobae (ORCID:0000000295396815)↗

A SiPM-based optical readout system for the EIC dual-radiator RICH

Silicon photomultipliers (SiPM) are candidates selected as the potential photodetector technology for the dual-radiator Ring-Imaging Cherenkov (dRICH) detector at the future Electron-Ion Collider (EIC). SiPM are cheap devices, highly efficient and insensitive to the high magnetic field at the expected location of the sensors in the experiment. Here, on the other hand, SiPM are not radiation tolerant. Despite the integrated radiation level is expected to be moderate it should be tested whether single photon-counting capabilities and the increase in dark count rate can be kept under control to maintain the optimal dRICH detector performance across the years. The current status of the research for the EIC dRICH application and the first results on studies performed on a sample of commercial and prototype SiPM sensors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Trigger Detection for the sPHENIX Experiment via Bipartite Graph Networks with Set Transformer

Trigger (interesting events) detection is crucial to high-energy and nuclear physics experiments because it improves data acquisition efficiency. It also plays a vital role in facilitating the downstream offline data analysis process. The sPHENIX detector, located at the Relativistic Heavy Ion Collider in Brookhaven National Laboratory, is one of the largest nuclear physics experiments on a world scale and is optimized to detect physics processes involving charm and beauty quarks. Furthermore, these particles are produced in collisions involving two proton beams, two gold nuclei beams, or a combination of the two and give critical insights into the formation of the early universe. This paper presents a model architecture for trigger detection with geometric information from two fast silicon detectors. Transverse momentum is introduced as an intermediate feature from physics heuristics. We also prove its importance through our training experiments. Each event consists of tracks and can be viewed as a graph. A bipartite graph neural network is integrated with the attention mechanism to design a binary classification model. Compared with the state-of-the-art algorithm for trigger detection, our model is parsimonious and increases the accuracy and the AUC score by more than 15%.

97 MATHEMATICS AND COMPUTING↗

Artificial Intelligence for imaging Cherenkov detectors at the EIC

Abstract Imaging Cherenkov detectors form the backbone of particle identification (PID) at the future Electron Ion Collider (EIC). Currently all the designs for the first EIC detector proposal use a dual Ring Imaging CHerenkov (dRICH) detector in the hadron endcap, a Detector for Internally Reflected Cherenkov (DIRC) light in the barrel, and a modular RICH (mRICH) in the electron endcap. These detectors involve optical processes with many photons that need to be tracked through complex surfaces at the simulation level, while for reconstruction they rely on pattern recognition of ring images. This proceeding summarizes ongoing efforts and possible applications of AI for imaging Cherenkov detectors at EIC. In particular we will provide the example of the dRICH for the AI-assisted design and of the DIRC for simulation and particle identification from complex patterns and discuss possible advantages of using AI.

Instruments & Instrumentation↗

Picosecond Timing Resolution Measurements of Low Gain Avalanche Detectors with a 120 GeV Proton Beam for the TOPSiDE Detector Concept

This paper presents results that take a critical step toward proving 10 ps timing resolution’s feasibility for particle identification in the TOPSiDE detector concept for the Electron-Ion Collider. Measurements of LGADs with a thickness of 35 μm and 50 μm are evaluated with a 120 GeV proton beam. The performance of the gain and timing response is assessed, including the dependence on the reverse bias voltage and operating temperature. The best timing resolution of UFSDs in a test beam to date is achieved using three combined planes of 35 μm thick LGADs at -30°C with a precision of 14.3 ± 1.5 ps.

Particle tracking detectors↗

Beam particle identification and tagging of incompletely stripped heavy beams with HEIST

A challenge preventing successful inverse kinematics measurements with heavy nuclei that are not fully stripped is identifying and tagging the beam particles. For this purpose, the HEavy ISotope Tagger (HEIST) has been developed. HEIST utilizes two micro-channel plate timing detectors to measure the time-of-flight, a multi-sampling ion chamber to measure energy loss, and a high-purity germanium detector to identify isomer decays and calibrate the isotope identification system. HEIST has successfully identified 198 Pb and other nearby nuclei at energies of about 75 MeV/A. In the experiment discussed, a typical cut containing 89% of all 198 Pb 80+ in the beam had a purity of 86%. We examine the issues of charge state contamination. Here, the observed charge state populations of these ions are presented and, using an adjusted beam energy, are well described by the charge state model GLOBAL.

47 OTHER INSTRUMENTATION↗

Shapes, softness, and nonyrast collectivity in 186 W

Nonyrast, excited states in neutron-rich 186 W were populated via inelastic-scattering reactions using beams of 136 Xe nuclei accelerated to 725 and 800 MeV. Levels populated in the reactions were investigated via particle-γ coincidence techniques using the Gammasphere array of high-purity germanium detectors and the compact heavy-ion counter, CHICO2. The K π = 2 + (γ ), K π = 0 + and K π = 2 – (octupole) rotational side bands were extended to spins 14h¯, 12h¯, and 13h¯, respectively. A staggering pattern observed in the energies of levels in the K π = 2 + band was found to be consistent with a potential that gets softer to vibration in the γ degree of freedom with increasing spin. Furthermore, the odd-even staggering of states in the K π = 2 – band was found to exhibit a phase opposite to that seen in the γ band; an effect most probably associated with Coriolis coupling to other, unobserved octupole vibrational bands in 186 W.

150 ≤ A ≤ 189↗

β decay of neutron-rich 76 Cu and the structure of 76 Zn

In this work, the β decay of 76 Cu to the levels of 76 Zn was studied at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Lab (ORNL). A purified 76 Cu beam was developed and data were recorded for the decay of the A=76 decay chain using four high-purity germanium (HPGe) clover detectors at the Low-energy Radioactive Ion Beam Spectroscopy Station (LeRIBSS). In this measurement, data on γ-ray emission following β decay, including βγ and γγ coincidences, were collected and γγ spectra were analyzed to identify the statistically significant coincidences. From this analysis, we propose a level scheme for 76 Zn which contains a total of 59 energy levels up to 6.0 MeV containing 105 γ rays. We have identified an additional 53 γ rays associated with this decay which could not be place in the decay scheme due to insufficient coincidence information or no energy match to identified levels. No γ rays from states in 75 Zn fed in the delayed-neutron branch were observed even though other γ rays in the A=75 decay chain were observed. Spin and parity assignments are proposed for some levels based on comparison to systematics and shell model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effectiveness of denoising diffusion probabilistic models for fast and high-fidelity whole-event simulation in high-energy heavy-ion experiments

Artificial intelligence (AI) generative models, such as generative adversarial networks (GANs), variational autoencoders, and normalizing flows, have been widely used and studied as efficient alternatives for traditional scientific simulations. However, they have several drawbacks, including training instability and inability to cover the entire data distribution, especially for regions where data are rare. This is particularly challenging for whole-event, full-detector simulations in high-energy heavy-ion experiments, such as sPHENIX at the Relativistic Heavy Ion Collider and Large Hadron Collider experiments, where thousands of particles are produced per event and interact with the detector. This work investigates the effectiveness of denoising diffusion probabilistic models (DDPMs) as an AI-based generative surrogate model for the sPHENIX experiment that includes the heavy-ion event generation and response of the entire calorimeter stack. DDPM performance in sPHENIX simulation data is compared with a popular rival, GANs. Results show that both DDPMs and GANs can reproduce the data distribution where the examples are abundant (low-to-medium calorimeter energies). Nonetheless, DDPMs significantly outperform GANs, especially in high-energy regions where data are rare. Additionally, DDPMs exhibit superior stability compared to GANs. The results are consistent between both central and peripheral centrality heavy-ion collision events. Moreover, DDPMs offer a substantial speedup of approximately a factor of 100 compared to the traditional Geant4 simulation method.

42 ENGINEERING↗

First direct measurement of the 13 $\mathrm{N(α, ρ)}$ 16 $\mathrm{O}$ reaction relevant for core-collapse supernovae nucleosynthesis

We report that understanding the explosion mechanism of a core-collapse supernova (CCSN) is important to accurately model CCSN scenarios for different progenitor stars using model-observation comparisons. The uncertainties of various nuclear reaction rates relevant for CCSN scenarios strongly affect the accuracy of these stellar models. Out of these reactions, the 13 N(α, p) 16 O reaction has been found to affect various stages of a CCSN at varying temperatures. This work presents the first direct measurement of the 13 N(α, p) 16 O reaction performed using a 34.6 MeV beam of radioactive 13 N ions and the active-target detector MUSIC (MUlti-Sampling Ionization Chamber) at Argonne National Laboratory. The resulting total 13 N(α, p) 16 O reaction cross sections from this measurement in the center-of-mass energy range of 3.26 - 6.02 MeV are presented and compared with calculations using the Hauser-Feshbach formalism. Uncertainties in the reaction rate have been dramatically reduced at CCSN temperatures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Studies of Quark Transport and Hadronization in Nuclei

In this project, we conducted the first measurement of di‑hadron azimuthal correlations in deep inelastic scattering (DIS) off nuclei using the CLAS detector at Jefferson Lab. Using 5 GeV electron‑beam data collected on deuterium, carbon, iron, and lead targets, we extracted di‑pion correlation functions over a broad kinematic range. The results show a monotonic broadening of the correlation peak with increasing nuclear mass, along with pronounced dependencies on the pions’ kinematics. Separately, we implemented an algorithm based on the Kalman filter that achieved the first complete alignment of the CLAS12 central tracking system. In parallel, we developed simulations, algorithms, and performance studies that informed the conceptual designs of the forward hadronic calorimeter Insert and the Zero Degree Calorimeter, both of which are now included in the ePIC detector baseline for the forthcoming Electron Ion Collider.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Thin-Entrance Window Process for Soft X-Ray Sensors

New free electron lasers, such as SLAC’s LCLS-II, will provide unique scientific imaging opportunities. In order to fully utilize these facilities, we need to develop detectors with shallow entrance windows that will enable detection of soft x-rays from 250 eV to 1.5 KeV. Achieving adequately shallow entrance windows is challenging because the high temperature anneal needed to activate the dopant also drives the dopant profile deeper, growing the region that is insensitive to soft x-rays. A new microwave annealing technology provides an efficient way to achieve shallow entrance windows in fully depleted high-resistivity silicon sensors. The microwave anneal technique can activate dopants at low substrate temperature, with minimal dopant diffusion, and can be used to fabricate both n-type and p-type entrance windows. SRP and SIMS measurements were used to verify dopant activation with negligible dopant diffusion. We then applied the microwave anneal process to a planar sensor wafer, using the new process to create the backside diode contact. Electrical test of the resulting sensors shows good reverse bias characteristics. The sensors have been bump-bonded to a read-out ASIC and used successfully to measure an Fe-55 x-ray spectrum. Process and device simulations were performed to characterize the quantum efficiency of the entrance window for soft x-rays. This technique is useful for other sensor applications requiring a shallow entrance window, including detectors for UV photons, low energy ions and low energy electrons.

47 OTHER INSTRUMENTATION↗

Tagged Short-Range Correlations for Medium to Heavy Ions at an Electron Ion Collider

Understanding short-range correlations between pairs of nucleons in the nucleus is an important nuclear physics topic that can address longstanding mysteries in nuclear physics such as the behavior of dense nuclear systems and the modification of parton distributions. As a collider and with a large acceptance detector, the Jefferson Lab version of the Electron Ion Collider has unique capabilities that are complementary to previous short-range correlation studies, most notably the ability to more fully reconstruct the final state. Optimization of the collider’s detector to maximally exploit these capabilities called for important extensions of existing simulation tools. For this one year laboratory directed research and development project, we upgraded the benchmark electron-nucleon event generator for lepto-production simulation code Benchmark eA Generator for LEptoproduction (BeAGLE) to be able to handle tagged medium-to-heavy nucleons. This included updating the code to correctly handle Fermi motion of nucleons in the nucleus as well as the large momentum caused by short-range correlations. In addition, we also investigated the possibility of improved kinematic reconstruction methods for electron nucleon collisions and looked at pair-spectator tagging of short-range correlations with the Jefferson Lab electron ion collider design. The project progressed very much as planned.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Halo removal experiments with hollow electron lens in the BNL Relativistic Heavy Ion Collider

A hollow electron beam has been proposed as an active control tool to remove the beam halo from high-energy, high-current hadron or ion machines (such as the High-Luminosity Large Hadron Collider). To study the halo removal rate and assess the effect on the ion beam core, one of the two electron lenses in the Relativistic Heavy Ion Collider was changed from a Gaussian beam profile to a hollow profile. We describe the design and verification of the hollow electron beam parameters as well as the methods to minimize the hollow beam profile distortions, which can result in an ion beam emittance increase. The hollow beam alignment with the ion beam by using a backscattered electron detector has been demonstrated. Furthermore, experiments were carried out to explore the efficiency of the halo removal by scanning the current and inner radius of the hollow electron beam, which is pulsed either every turn or every nth turn. The effects of the hollow electron beam on the ion beam emittance and luminosity were also assessed experimentally by scanning the inner radius of the electron beam.