Radiation 101: Effects on Hardware and Robotic Systems

We present basic information on different types of radiation effects, including total ionizing dose, displacement damage, and single-event effects. The content is designed to educate space weather professionals, space operations professionals, and other science and engineering stakeholders.

radiation effects↗

Radiation 101: Effects on Hardware and Robotic Systems

We present basic information on different types of radiation effects, including total ionizing dose, displacement damage, and single-event effects. The content is designed to educate space weather professionals, space operations professionals, and other science and engineering stakeholders.

non-ionizing energy loss (NIEL)↗

Investigating Biological Responses to Deep Space Radiation for Missions Beyond Low Earth Orbit (LEO) using Yeast

To enable long-term spaceflight missions and establish habitation on the Moon and Mars, we require a comprehensive understanding of the effects of chronic deep space radiation exposure on humans. BioSentinel is NASA’s first biological CubeSat to venture beyond Low Earth Orbit (LEO). It utilizes Saccharomyces cerevisiae (budding yeast) as a model organism to study biological responses to deep space radiation. Yeast share significant genetic homology with humans, including basic cellular metabolism and DNA repair mechanisms. In addition, unlike human cell cultures, yeast can survive the duration and constraints of a deep space mission. BioSentinel measures biological responses using an optical system and alamarBlue oxidation-reduction (redox) dye. Two strains of yeast are studied - a wild-type and a rad51 mutant strain that is deficient in DNA repair. Changes in metabolism and growth are monitored throughout the nominal 6-month mission. Preliminary tests indicate a significant change in the alamarBlue response to low-dose ionizing radiation (IR). Additionally, rad51 cells have shown an IR dose-dependent decrease in glucose uptake and accumulation of oxidized NADH (NAD+). These biomolecules are involved in reactions responsible for basic cell processes, including growth and development, signaling, and respiration. The current study expanded upon previous data by exposing yeast to deep space-relevant radiation. Glucose and NADH/NAD+ assays were conducted on yeast subjected to varying dosages of high-energy Fe-56 and simulated galactic cosmic rays (GCRs). The resulting data was analyzed using Excel and GraphPad Prism. A particular focus was to identify biomolecules resulting from aerobic respiration, which requires the presence of oxygen, or anaerobic processes. As long-term spaceflight missions draw near, it is increasingly important to characterize biological processes affected by the conditions of deep space. Studying biomolecular damage caused by deep space radiation may enable the development of engineering controls or biomedical therapeutics that mitigate health complications for future astronauts.

Kyra Keenan↗

Radiation-Dependent Limit for the Viability of Bacterial Spores in Halite Fluid Inclusions and on Mars

When claims for the long-term survival of viable organisms are made, either within terrestrial minerals or on Mars, considerations should be made of the limitations imposed by the naturally occurring radiation dose to which they have been exposed. We investigated the effect of ionizing radiation on different bacterial spores by measuring the inactivation constants for B. subtilis and s. marismortui spores in solution as well as for dry spores of B. subtilis and B. thuringiensis. S. marismortui is a halophilic spore that is genetically similar to the recently discovered 2-9-3 bacterium from a halite fluid inclusion, claimed to be 250 million years old, B. thuringiensis is a soil bacterium that is genetically similar to the human pathogens B. anthracis and B. cereus. To relate the inactivation constant to some realistic environments, we calculated the radiation regimen in a halite fluid inclusion and in the Martian subsurface over time. Our conclusion is that the ionizing dose of radiation in those environments limits the survival of viable bacterial spores over long periods. In the absence of an active repair mechanism in the dormant state, the long-term survival of spores is limited to less than 109 million years in halite fluid inclusions, to 100 to 160 million years in the Martian subsurface below 3 m, and to less than 600,000 years in the upper-most meter of Mars.

Kminek, Gerhard↗

Total Dose Effects on Single Event Transients in Digital CMOS and Linear Bipolar Circuits

This presentation discusses the effects of ionizing radiation on single event transients (SETs) in circuits. The exposure of integrated circuits to ionizing radiation changes electrical parameters. The total ionizing dose effect is observed in both complementary metal-oxide-semiconductor (CMOS) and bipolar circuits. In bipolar circuits, transistors exhibit grain degradation, while in CMOS circuits, transistors exhibit threshold voltage shifts. Changes in electrical parameters can cause changes in single event upset(SEU)/SET rates. Depending on the effect, the rates may increase or decrease. Therefore, measures taken for SEU/SET mitigation might work at the beginning of a mission but not at the end following TID exposure. The effect of TID on SET rates should be considered if SETs cannot be tolerated.

Buchner, S.↗

SRAM-based FPGA: high dose test methods using evaluation boards

We present low-cost and effective methods and results for high levels of Total Ionizing Dose testing performed on the Xilinx Kintex UltraScale (20nm) Field-Programmable Gate Array evaluation board using 60Co and 2 MeV electron sources.

Thorbourn, Dennis↗

BioSentinel/Mars: Interplanetary Space Radiation Biosensor Experiment in Martian Transit on Mars 2020

Despite significant progress understanding biological radiation effects via terrestrial studies, no terrestrial source duplicates space’s unique radiation environment. Furthermore, no biological experiments have been conducted beyond low Earth orbit since Apollo. Understanding space’s fundamental biological effects requires overcoming these limitations. The BioSentinel 4U payload, under development for flight aboard Exploration Mission-1, measures biological responses to deep space radiation. Traveling to more than 1AU from Earth, BioSentinel/EM-1 will record DNA double-strand breaks (DSBs) repaired using a pathway common to humans and BioSentinel’s bioengineered yeast model organism, responding to as few as one biologically repaired DSB. The BioSentinel/Mars 4U instrument (6-8kg; 5-8W; 0.2-1MB/week) would include eighteen 16-well biosensor fluidic cards, activated biweekly during Mars 2020’s cruise phase, to provide a dose-dependent rate of DSB/repair. The instrument, which includes solid-state sensors for total ionizing dose and linear-energy-transfer spectra, addresses MEPAG SKG-B3 by simultaneously measuring both spectra and biological effects of space radiation. Biological measurements are rendered reliable by independent replicate experiments. The spatio-temporal uniformity of interplanetary galactic cosmic radiation makes BioSentinel/EM1 and BioSentinel/Mars approximate replicates, except for any major differences in solar particle events. Results will be compared to Earth and ISS controls to characterize the radiation/reduced-gravity parameter space by its biological impact.

BioSentinel↗

Total Dose Effects on Error Rates in Linear Bipolar Systems

The shapes of single event transients in linear bipolar circuits are distorted by exposure to total ionizing dose radiation. Some transients become broader and others become narrower. Such distortions may affect SET system error rates in a radiation environment. If the transients are broadened by TID, the error rate could increase during the course of a mission, a possibility that has implications for hardness assurance.

Buchner, Stephen↗

Total Dose Effects on Single Event Transients in Linear Bipolar Systems

Single Event Transients (SETs) originating in linear bipolar integrated circuits are known to undermine the reliability of electronic systems operating in the radiation environment of space. Ionizing particle radiation produces a variety of SETs in linear bipolar circuits. The extent to which these SETs threaten system reliability depends on both their shapes (amplitude and width) and their threshold energies. In general, SETs with large amplitudes and widths are the most likely to propagate from a bipolar circuit's output through a subsystem. The danger these SET pose is that, if they become latched in a follow-on circuit, they could cause an erroneous system response. Long-term exposure of linear bipolar circuits to particle radiation produces total ionizing dose (TID) and/or displacement damage dose (DDD) effects that are characterized by a gradual degradation in some of the circuit's electrical parameters. For example, an operational amplifier's gain-bandwidth product is reduced by exposure to ionizing radiation, and it is this reduction that contributes to the distortion of the SET shapes. In this paper, we compare SETs produced in a pristine LM124 operational amplifier with those produced in one exposed to ionizing radiation for three different operating configurations - voltage follower (VF), inverter with gain (IWG), and non-inverter with gain (NIWG). Each configuration produces a unique set of transient shapes that change following exposure to ionizing radiation. An important finding is that the changes depend on operating configuration; some SETs decrease in amplitude, some remain relatively unchanged, some become narrower and some become broader.

Buchner, Stephen↗

Shields-1, A SmallSat Radiation Shielding Technology Demonstration

The NASA Langley Research Center Shields CubeSat initiative is to develop a configurable platform that would allow lower cost access to Space for materials durability experiments, and to foster a pathway for both emerging and commercial-off-the-shelf (COTS) radiation shielding technologies to gain spaceflight heritage in a relevant environment. The Shields-1 will be Langleys' first CubeSat platform to carry out this mission. Radiation shielding tests on Shields-1 are planned for the expected severe radiation environment in a geotransfer orbit (GTO), where advertised commercial rideshare opportunities and CubeSat missions exist, such as Exploration Mission 1 (EM-1). To meet this objective, atomic number (Z) graded radiation shields (Zshields) have been developed. The Z-shield properties have been estimated, using the Space Environment Information System (SPENVIS) radiation shielding computational modeling, to have ~30% increased shielding effectiveness of electrons, at half the thickness of a corresponding single layer of aluminum. The Shields-1 research payload will be made with the Z-graded radiation shields of varying thicknesses to create dose-depth curves to be compared with baseline materials. Additionally, Shields-1 demonstrates an engineered Z-grade radiation shielding vault protecting the systems' electronic boards. The radiation shielding materials' performances will be characterized using total ionizing dose sensors. Completion of these experiments is expected to raise the technology readiness levels (TRLs) of the tested atomic number (Z) graded materials. The most significant contribution of the Z-shields for the SmallSat community will be that it enables cost effective shielding for small satellite systems, with significant volume constraints, while increasing the operational lifetime of ionizing radiation sensitive components. These results are anticipated to increase the development of CubeSat hardware design for increased mission lifetimes, and enable out of low earth orbit (LEO) missions by using these tested material concepts as shielding for sensitive components and new spaceflight hardware

Thomsen, D. Laurence, III↗

Total-dose radiation effects data for semiconductor devices, volume 3

Volume 3 of this three-volume set provides a detailed analysis of the data in Volumes 1 and 2, most of which was generated for the Galileo Orbiter Program in support of NASA space programs. Volume 1 includes total ionizing dose radiation test data on diodes, bipolar transistors, field effect transistors, and miscellaneous discrete solid-state devices. Volume 2 includes similar data on integrated circuits and a few large-scale integrated circuits. The data of Volumes 1 and 2 are combined in graphic format in Volume 3 to provide a comparison of radiation sensitivities of devices of a given type and different manufacturer, a comparison of multiple tests for a single data code, a comparison of multiple tests for a single lot, and a comparison of radiation sensitivities vs time (date codes). All data were generated using a steady-state 2.5-MeV electron source (Dynamitron) or a Cobalt-60 gamma ray source. The data that compose Volume 3 represent 26 different device types, 224 tests, and a total of 1040 devices. A comparison of the effects of steady-state electrons and Cobat-60 gamma rays is also presented.

Price, W. E.↗

Comparison of the degradation effects of heavy ion, electron, and cobalt-60 irradiation in an advanced bipolar process

Experimental measurements are reported of the degradation effects of high-energy particles (heavy Br ions and electrons) and Co-60 gamma-rays on the current gain of minimum-geometry bipolar transistors made from an advanced process. The data clearly illustrate the total-ionizing-dose vs particle-fluence behavior of this bipolar transistor produced by an advanced process. In particular, bulk damage from Co-60 gamma rays in bipolar transistors (base transport factor degradation) and surface damage in bipolar transistors from ionizing radiation (emitter-efficiency degradation) have been observed. The true equivalence between various types of radiation for this process technology has been determined on the basis of damage from the log K1 intercepts.

Zoutendyk, John A.↗

A Deterministic Electron, Photon, Proton and Heavy Ion Radiation Transport Suite for the Study of the Jovian System

A deterministic suite of radiation transport codes, developed at NASA Langley Research Center (LaRC), which describe the transport of electrons, photons, protons, and heavy ions in condensed media is used to simulate exposures from spectral distributions typical of electrons, protons and carbon-oxygen-sulfur (C-O-S) trapped heavy ions in the Jovian radiation environment. The particle transport suite consists of a coupled electron and photon deterministic transport algorithm (CEPTRN) and a coupled light particle and heavy ion deterministic transport algorithm (HZETRN). The primary purpose for the development of the transport suite is to provide a means for the spacecraft design community to rapidly perform numerous repetitive calculations essential for electron, proton and heavy ion radiation exposure assessments in complex space structures. In this paper, the radiation environment of the Galilean satellite Europa is used as a representative boundary condition to show the capabilities of the transport suite. While the transport suite can directly access the output electron spectra of the Jovian environment as generated by the Jet Propulsion Laboratory (JPL) Galileo Interim Radiation Electron (GIRE) model of 2003; for the sake of relevance to the upcoming Europa Jupiter System Mission (EJSM), the 105 days at Europa mission fluence energy spectra provided by JPL is used to produce the corresponding dose-depth curve in silicon behind an aluminum shield of 100 mils ( 0.7 g/sq cm). The transport suite can also accept ray-traced thickness files from a computer-aided design (CAD) package and calculate the total ionizing dose (TID) at a specific target point. In that regard, using a low-fidelity CAD model of the Galileo probe, the transport suite was verified by comparing with Monte Carlo (MC) simulations for orbits JOI--J35 of the Galileo extended mission (1996-2001). For the upcoming EJSM mission with a potential launch date of 2020, the transport suite is used to compute the traditional aluminum-silicon dose-depth calculation as a standard shield-target combination output, as well as the shielding response of high charge (Z) shields such as tantalum (Ta). Finally, a shield optimization algorithm is used to guide the instrument designer with the choice of graded-Z shield analysis.

Norman, Ryan B.↗

Investigation of HZETRN 2010 as a Tool for Single Event Effect Qualification of Avionics Systems

NASA's future missions are focused on deep space for human exploration that do not provide a simple emergency return to Earth. In addition, the deep space environment contains a constant background Galactic Cosmic Ray (GCR) radiation exposure, as well as periodic Solar Particle Events (SPEs) that can produce intense amounts of radiation in a short amount of time. Given these conditions, it is important that the avionics systems for deep space human missions are not susceptible to Single Event Effects (SEE) that can occur from radiation interactions with electronic components. The typical process to minimizing SEE effects is through using heritage hardware and extensive testing programs that are very costly. Previous work by Koontz, et al. [1] utilized an analysis-based method for investigating electronic component susceptibility. In their paper, FLUKA, a Monte Carlo transport code, was used to calculate SEE and single event upset (SEU) rates. This code was then validated against in-flight data. In addition, CREME-96, a deterministic code, was also compared with FLUKA and in-flight data. However, FLUKA has a long run-time (on the order of days), and CREME-96 has not been updated in several years. This paper will investigate the use of HZETRN 2010, a deterministic transport code developed at NASA Langley Research Center, as another tool that can be used to analyze SEE and SEU rates. The benefits to using HZETRN over FLUKA and CREME-96 are that it has a very fast run time (on the order of minutes) and has been shown to be of similar accuracy as other deterministic and Monte Carlo codes when considering dose [2, 3, 4]. The 2010 version of HZETRN has updated its treatment of secondary neutrons and thus has improved its accuracy over previous versions. In this paper, the Linear Energy Transfer (LET) spectra are of interest rather than the total ionizing dose. Therefore, the LET spectra output from HZETRN 2010 will be compared with the FLUKA and in-flight data to validate HZETRN 2010 as a computational tool for SEE qualification by analysis. Furthermore, extrapolation of these data to interplanetary environments at 1 AU will be investigated to determine whether HZETRN 2010 can be used successfully and confidently for deep space mission analyses.

Rojdev, Kristina↗

Radiation Specifications for Fission Power Conversion Component Materials

NASA has been supporting design studies and technology development that could provide power to an outpost on the moon, Mars, or an asteroid. One power-generation system that is independent of sunlight or power-storage limitations is a fission-based power plant. There is a wealth of terrestrial system heritage that can be transferred to the design and fabrication of a fission power system for space missions, but there are certain design aspects that require qualification. The radiation tolerance of the power conversion system requires scrutiny because the compact nature of a space power plant restricts the dose reduction methodologies compared to those used in terrestrial systems. An integrated research program has been conducted to establish the radiation tolerance of power conversion system-component materials. The radiation limit specifications proposed for a Fission Power System power convertor is 10 Mrad ionizing dose and 5 x 10(exp 14) neutron per square centimeter fluence for a convertor operating at 150 C. Specific component materials and their radiation tolerances are discussed. This assessment is for the power convertor hardware; electronic components are not covered here.

Bowman, Cheryl L.↗

Shields-1 Energetic Proton Dose Comparison from Solar Minimum and Active Periods

Shields-1 has been operating in polar low earth orbit since December 2018 as part of the CubeSat Launch Initiative (CSLI) Educational Launch of Nanosatellites (ELaNa)XIX Mission. Shields-1 has 8 Teledyne µdosimeters behind shielding. These shielded µdosimeters have high minimum proton energy thresholds. The Shields-1 electronics enclosure µdosimeter has a minimum proton threshold energy of 151 MeV. The annualized total ionizing dose (TID) in the electronics enclosure was 75.6 +/- 3.2 RAD from July-August 2019, which was a solar minimum period. In contrast, the annualized TID was 61.0 +/- 2.5 RAD in July 2023, a solar active month. The TID change can be attributed to both the reduction in radiation at the South Atlantic Anomaly (SAA) and the decrease in galactic cosmic radiation during increasing solar activity. The measured GCR dose over the poles was reduced during the July 2023 solar active period in comparison with the July 2019 solar minimum period, using the most sensitive µdosimeter channel for the measurement. Shields-1 has demonstrated the capability of measuring the changes in high energy protons in polar low earth orbit during changes in solar activity, which contributes to the understanding of Earth in the heliosphere.

Shields-1 Dosimetry Space Sciences↗

Neuro-behavioral Consequences of Low Dose Radiation Social Isolation and Sex Differences in the Longevity MCAT Mouse Model

The physiological responses to spaceflight elicit wide-ranging consequences and resemble aspects of aging on Earth. Previous studies have shown that oxidative damage via reactive oxygen species (ROS), contributes to aging-related pathologies. Our study uses 1-year old C57BL/6NJ male and female mice (astronaut-relevant age) that underwent exposure to 0.5 gray of gamma radiation together with social isolation and were euthanized 12 weeks after. We used the longevity MCAT mouse model in which human catalase is overexpressed in the mitochondria, for ROS quenching. We aimed to determine whether in older mice quenching ROS, will mitigate the neuro-behavioral consequences of low dose ionizing radiation and/or social isolation and whether the outcomes will differ in males and females. We have performed five mission relevant behavioral tests which focused on performance, memory, physical stance, and stress. We have detected both sex and radiation effects; the older females look physically better are faster and perform better almost in all behavioral tests compared to their male counterparts. On the other hand, they are more sensitive to low dose radiation in many cases, in some cases this effect was indeed mitigated in the MCAT mice, pointing out to the importance of ROS in response to radiation stress and social isolation. We have measured plasma (7- and 90-days post radiation), cytokines, corticosterone and hippocampal cytokine and microglial activation at the end of the experiment. We saw significant changes in the plasma markers due to radiation, sex, and genotype in both short and long post radiation period and detected long term sex and radiation effects in the brain. Our focus is now on applying advanced statistical modeling to corelate the behavioral tests with our recent molecular findings to look for specific biomarkers that could predict behavioral deficits.

radiation↗

Effects of neutron irradiation on the characteristics of a buried channel CCD at 80 degrees Kelvin and 295 degrees Kelvin

Buried channel CCD shift registers were irradiated with 15 MeV neutrons. The irradiations were performed at 80 K and 295 K on operating devices with normal clocks and bias voltages applied. Dark current increased from the pre-irradiation value of 7 nA/sq cm to 1,600 nA/sq cm at 1 x 10 to the 13th power n/sq cm. The input gate threshold shift observed at 80K was minus 0.9 volts per 10 to the 13th power n/sq cm, a factor of 4 less than that predicted from a first order calculation of the equivalent ionization dose of neutrons in the oxide. Transfer efficiency measurements yielded a bulk electron trap creation rate for neutron irradiation of 14.0 cm to the minus 1 power at 295 K with a trap emission time constant of 25 microseconds.

Saks, N. S.↗