Search NASA⌕ Search

SEARCH · Search NASA

Results for “Ions Separations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Greatly Increasing Trapped Ion Populations for Mobility Separations Using Traveling Waves in Structures for Lossless Ion Manipulations

The initial use of traveling waves (TW) for ion mobility (IM) separations using a structures for lossless ion manipulations (SLIM) employed an ion funnel trap (IFT) to accumulate ions from a continuous electrospray ionization source, and limited to injected ion populations of ~106 charges due to the onset of space charge effects in the trapping region. Additional limitations arise due to the loss of resolution for the injection of ions over longer periods (e.g. in extended pulses). In this work a new SLIM ‘flat funnel’ (FF) module has been developed and demonstrated to enable the accumulation of much larger ion populations and their injection for IM separations. Ion current measurements indicate a capacity of ~3.2×108 charges for the extended trapping volume, over an order of magnitude greater than the IFT. The orthogonal ion injection into a funnel shaped separation region can greatly reduce space charge effects during the initial IM separation stage, and the gradually reduced width of the path allows the ion packet to be increasingly compressed in the lateral dimension as the separation progresses, allowing e.g. efficient transmission through conductance limits or compatibility with subsequent ion manipulations. This work examined the TW, RF, and DC confining field SLIM parameters involved in ion accumulation, injection, transmission and separation in the FF IM module using both direct ion current and MS measurements. Wide m/z range ion transmission is demonstrated, along with significant increases in signal to noise (S/N) ratios due to the larger ion populations injected. Additionally, we observed a reduction in the chemical background, which was attributed to more efficient desolvation of solvent related clusters over the extended ion accumulation periods. The TW SLIM FF IM module is anticipated to be especially effective as a front end for long path SLIM IM separation modules.

Environmental Molecular Sciences Laboratory↗

Ion-exchange chromatography separation applied to mineral recycle in closed systems

As part of the controlled ecological life support system (CELSS) program, a study is being made of mineral separation on ion-exchange columns. The purpose of the mineral separation step is to allow minerals to be recycled from the oxidized waste products of plants, man, and animals for hydroponic food production. In the CELSS application, relatively large quantities of minerals in a broad concentration range must be recovered by the desired system, rather than the trace quantities and very low concentrations treated in analytical applications of ion-exchange chromatography. Experiments have been carried out to assess the parameters pertinent to the scale-up of ion-exchange chromatography and to determine feasibility. Preliminary conclusions are that the column scale-up is in a reasonable size range for the CELSS application. The recycling of a suitable eluent, however, remains a major challenge to the suitability of using ion exchange chromatography in closed systems.

Ballou, E.↗

Performance Enhancements in Differential Ion Mobility Spectrometry-Mass Spectrometry (DMS-MS) by Using a Modified CaptiveSpray Source

Differential ion mobility spectrometry (DMS) spatially separates ions in the gas phase using the mobility differences of the ions under applied low and high electric fields. The use of DMS as an ion filter (or ion selector) prior to mass spectrometry analysis has been compromised by the limited ion transmission efficiency. This paper reports enhancement of the DMS-MS sensitivity and signal stability using a modified CaptiveSpray™ source. In terms of the ion sampling and transmission efficiency, the modified CaptiveSpray source swept ~ 89% of the ions generated by the tapered capillary through the DMS device (compared to ~ 10% with a conventional microspray source). The signal fluctuation improved from 11.7% (relative standard deviation, RSD) with microspray DMS-MS to 3.6% using CaptiveSpray-DMS-MS. Coupling of LC to DMS-MS via the modified CaptiveSpray source was simple and robust. Using DMS as a noise-filtering device, LC-DMS-MS performed better than conventional LC-MS for analyzing a BSA digest standard. Although LC-DMS-MS had a lower sequence coverage (55%), a higher Mascot score (283) was obtained compared to those of LC-MS (sequence coverage 65%; Mascot score 192) under the same elution conditions. The improvement in the confidence of the search result was attributed to the preferential elimination of noise ions. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Beyond Local Solvation Structure: Nanometric Aggregates in Battery Electrolytes and their Effect on Electrolyte Properties

Electrolytes are an essential component of all electrochemical storage and conversion devices, such as batteries. In the history of battery development, the complex nature of electrolytes has often been a bottleneck. Fundamental knowledge of electrolyte systems encompasses elucidation of structure-property relationships of the solution species. Recently, nanometric aggregates have been observed in several classes of electrolytes, including super-concentrated, redox-flow, multivalent, polymer, and ionic liquid-based electrolytes. Compared with the well-studied local solvation structures such as contact ion pairs and solvent-separated ions, these aggregates impose unique effects on the ion distribution and transport both within bulk electrolytes and at electrode/electrolyte interfaces. This Perspective highlights the discovery of the aggregates in various battery electrolytes and their impact on electrolyte properties. We also present an outlook for future studies of this emerging field of nanometric aggregates and the need for the development of new experimental and computational tools to study their properties.

Yu, Zhou↗

PageRank as a Collective Variable to Study Complex Chemical Transformations and Their Energy Landscapes

A reduced set of reaction coordinates are often employed in chemistry to describe the collective change between reactants and products within the context of rare event theories and in the exploration of energy landscapes. While incredibly powerful, use of these collective variables becomes increasingly challenging as the systems under study become more complex. Recent advancement of new descriptions of collective molecular coordinates have included PageRank (PR) analysis of the network of interactions about molecules and atoms within a system. Herein, PR is developed as a continuous variable that not only captures chemical transformations but can also be employed as a collective variable for a process that could span a highly dimensional energy surface. The derivatives of PR with respect to atomic coordinates are presented, and subsequently combined with forces during a chemical transformation within biased molecular dynamics sampling simulations to create the potential of mean force (PMF). This technique is demonstrated for two reactions: 1) the transformation of tetrahedral [Al(OH)4]-(aq) to octahedral [Al(OH)4(H2O)2]-(aq), and 2) the formation of contact ion pairs (CIPs) and solvent separated ion pairs (SSIPs) of Na+ and OH- in bulk water. Comparison of the behavior of the PR collective variable in both examples reveals that the ability of the PR to resolve local versus extended configurational attributes is tuned by the size of the network employed. This is a unique feature of PageRank that enables control over the resolution of the PMF that is produced.

chemistry, theories, PageRank↗

Plasma physics effects on thermonuclear burn rate in the presence of hydrodynamic mix

Hydrodynamic mix can significantly degrade thermonuclear burn rate in an inertial confinement fusion (ICF) target. Successful mitigation requires a detailed understanding of the physical mechanisms by which mix affects burn. Here we summarize the roles of three distinct plasma physics effects on burn rate. The first is the well-known effect of enhanced thermal energy loss from the hot spot and the mitigating role of self-generated or externally-applied magnetic field. The second is the fuel ion separation via inter-species ion diffusion driven by the powerful thermodynamic forces exacerbated by mix during the implosion process. The third is the fusion reactivity modification by fast ion transport in a mix-dominated ICF target, where hot plasma is intermingled with cold fuel.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Variable-Energy Ion Beams For Modification Of Surfaces

Beam of low-energy negative oxygen ions used to grow layer of silicon dioxide on silicon. Beam unique both in purity, contains no molecular oxygen or other charged species, and in low energy, which is insufficient to damage silicon by physically displacing atoms. Low-energy growth accomplished with help of ion-beam apparatus. Directs electrons into crosswise stream of gas, generating stream of negative ions. Pair of charged plates separates ions from accompanying electrons and diverts ion beam to target - silicon substrate. Diameter of beam at target 0.5 to 0.75 cm. Promises useful device to study oxidation of semiconductors and, in certain applications, to replace conventional oxidation processes.

Chutjian, Ara↗

Plasma mass separation

Here, this tutorial describes mechanisms for separating ions in a plasma device with respect to their atomic or molecular mass for practical applications. The focus here is not on separating isotopes of a single atomic species but rather on systems with a much lower mass resolution and a higher throughput. These separation mechanisms include ion gyro-orbit separation, drift-orbit separation, vacuum arc centrifugation, steady-state rotating plasmas, and several other geometries. Generic physics issues are discussed such as the ion charge state, neutrals and molecules, collisions, radiation loss, and electric fields and fluctuations. Generic technology issues are also discussed such as plasma sources and ion heating, and suggestions are made for future research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flow of a plasma of multielectron elements along a magnetic field

An analysis is made of a flow of Ar plasma imitating plasma flows in ion separation systems such as systems for processing spent nuclear fuel or ion cyclotron resonance isotope separation systems. It is found that the electron temperature is equalized along the flow by electron heat conduction. When the electron temperature is not too low (T{sub e} {>=} E{sub ion}/10, where E{sub ion} is the ionization energy), multicharged ions are intensely produced along the entire flow. It is shown that this process is accompanied by the flow acceleration. Difficulties in describing a supersonic flow by hydrodynamic equations are pointed out.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accumulation of Large Ion Populations with High Ion Densities and Effects Due to Space Charge in Traveling Wave-Based Structures for Lossless Ion Manipulations (SLIM) IMS-MS

The accumulation of very large ion populations in traveling wave (TW)-based Structures for Lossless ion Manipulations (SLIM) has been studied to better understand aspects of ‘in-SLIM’ ion accumulation, and particularly its use in conjunction with ion mobility spectrometry (IMS). A linear SLIM ion path was implemented that had a ‘gate’ for blocking and accumulating ions for arbitrary time periods. Removing the gate potential caused ions to exit and the spatial distributions of accumulated ions were examined. The ion populations for a set of peptides were observed to increase with increased accumulation times until space change effects became significant, after which the peptide precursor ion populations decreased due to growing space charge-related ion activation, reactions, and losses. Ions closest to the gate were preferentially activated, and increasingly so with added storage times, TW amplitude, and the size of the total ion population. For analytical applications, we found that relatively weak TWs in the accumulation/storage region should be utilized to prevent or minimize ion losses and/or ion heating effects that can also lead to fragmentation. Our results further indicate that an accumulation region close to the SLIM entrance is advantageous for both speeding accumulation, minimizing ion heating, and avoiding ion population profiles that result in IMS peak tailing. Importantly, space charge-driven separations were observed for large populations of accumulated species and attributed to the opposing effects of space charge and the TW. In these separations, ion species form distributions or peaks, sometimes moving against the TW, and ordered in the SLIM based on their mobilities. Such separations may offer utility for ion pre-fractionation of ions and increasing the dynamic range measurements, increasing the resolving power of IMS separations by decreasing peak widths for accumulated ion populations, and other purposes benefitting from separations of extremely large ion populations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pendular Proteins in Gases and New Avenues for Characterization of Macromolecules by Ion Mobility Spectrometry

Polar molecules align in electric fields when the dipole energy (proportional to field intensity E × dipole moment p) exceeds the thermal rotational energy. Small molecules have low p and align only at inordinately high E or upon extreme cooling. Many biomacromolecules and ions are strong permanent dipoles and may align at E achievable in gases and room temperature. The collision cross sections of aligned ions with gas molecules generally differ from orientationally averaged quantities, affecting ion mobilities measured in ion mobility spectrometry (IMS). Field asymmetric waveform IMS (FAIMS) separates ions by the difference between mobilities at high and low E and hence can resolve and identify macroion conformers based on the mobility difference between pendular and free rotor states. An exceptional sensitivity of that difference to the ion geometry and charge distribution holds the potential for a powerful new method for separation and characterization of macromolecular species. Theory predicts that the pendular alignment of ions in gases at any E requires a minimum p depending on the ion mobility, gas pressure, and temperature. At ambient conditions used in current FAIMS systems, the p for realistic ions must exceed ~300 - 400 Debye. The dipole moments of proteins statistically increase with increasing mass, and such values are typical above ~30 kDa. FAIMS analyses of protein ions and complexes of ~30 - 130 kDa show an order-of-magnitude expansion of separation space compared to smaller proteins and other ions, consistent with expectations for the dipole-aligned regime.

59 BASIC BIOLOGICAL SCIENCES↗

Tandem Mass-Selective Cryogenic Digital Ion Traps for Enhanced Cluster Formation

We present the implementation of tandem mass-selective cryogenic ion traps, designed to enhance the range of ion processing capabilities that can be performed prior to spectroscopic interrogation. We show that both the formation of ion clusters and mass filtering steps can be combined in a single cryogenic linear quadrupole ion trap driven by RF square waves. Mass filtering and mass isolation can be achieved by manipulation of the RF frequency and duty cycle. Very importantly, this scheme circumvents the need for high-amplitude RF voltages that can be incompatible with typical cryogenic ion processing conditions. In addition, proper adjustment of the stability boundaries during the clustering process allows for the preferential formation of a specific cluster size rather than a broad distribution of sizes. Lastly, we show that a specific cluster size can be formed, mass-selected, and then transferred to another ion trap for a second completely separate ion processing step. Furthermore, the instrumentation and modular design developed here expand the scope of ionic species and clusters that can be accessed by processing electrosprayed ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ab initio molecular dynamics simulation of proton hopping in a model polymer membrane

We report the results of ab initio molecular dynamics simulations of a model NafionTM polymer membrane initially equilibrated using classical molecular dynamics simulations. We studied three hydration levels (λ) of 3, 9, and 15 H2O/SO3- corresponding to dry, hydrated and saturated fuel cell membrane, respectively. The barrier for proton transfer from the SO3-–H3O+ contact ion pair to a solvent-separated ion pair decreased from 2.3 kcal/mol for λ = 3 to 0.8 kcal/mol for λ = 15. The barrier for proton transfer between two water molecules was in the range from 0.7 to 0.8 kcal/mol for the λ values studied. The number of proton shuttling events between a pair of water molecules is an order of magnitude more than the number of proton hops across three distinct water molecules. The proton diffusion coefficient at λ = 15 is about 0.9x10-5 cm2/s, which is in good agreement with experiment and our previous quantum hopping molecular dynamics simulations.

ab initio molecular dynamics↗

Separation of rare earth elements using ion exchange

Separation of rare earth chlorides in solution using ion exchange. To access the model referenced in the report, please visit https://www.netl.doe.gov/energy-analysis/details?id=2024BE7A-2073-41EE-AFBF-9C2D22D819B3

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Comparative Ab Initio Study of the Primary Hydration and Proton Dissociation of Various Imide and Sulfonic Acid Ionomers

We compare the role of neighboring group substitutions on proton dissociation of hydrated acidic moieties suitable for proton exchange membranes through electronic structure calculations. Three pairs of ionomers containing similar electron withdrawing groups within the pair were chosen for the study: two fully fluorinated sulfonyl imides (CF3SO2NHSO2CF3 and CF3CF2SO2NHSO2CF3), two partially fluorinated sulfonyl imides (CH3SO2NHSO2CF3 and C6H5SO2NHSO2CF2CF3), and two aromatic sulfonic acid based material s (CH3C6H4SO3H and CH3 OC6 - H3OCH3C6H4SO3H). Fully optimized counterpoise (CP) corrected geometries were obtained for each ionomer fragment with the inclusion of water molecules at the B3LYP/6-311G** level of density functional theory. Spontaneous proton dissociation was observed upon addition of three water molecules in each system, and the transition to a solvent-separated ion pair occurred when four water molecules were introduced. No considerable quantitative or qualitative differences in proton dissociation, hydrogen bond networks formed, or water binding energies were found between systems containing similar electron withdrawing groups. Each of the sulfonyl imide ionomers exhibited qualitatively similar results regarding proton dissociation and separation. The fully fluorinated sulfonyl imides, however, showed a greater propensity to exist in dissociated and ion-pair separated states at low degrees of hydration than the partially fluorinated sulfonyl imides. This effect is due to the additional electron withdrawing groups providing charge stabilization as the dissociated proton migrates away from the imide anion.

30 DIRECT ENERGY CONVERSION↗

Quiet Plasma Source

Synthesis of plasma from separate ion and electron emitters suppresses electromagnetic interference. Source employs separate emitters for electrons and ions. Plasma source used to simulate variety of astrophysical phenomena and space-plasma effects. For example, used in studies of propagation of electromagnetic waves in plasmas. Serves as interference-free charge neutralizer.

Leung, P. L.↗

3D Printing of Highly Porous Polypropylene Separators for Lithium‐Ion Batteries Using Fused Deposition Modeling and Thermally Induced Phase Separation

Appearing as one of the key-components of lithium-ion batteries (LIBs), this work specifically focuses on the additive manufacturing (AM) of custom-shape separators, facilitated by the filament material extrusion process, also called fused deposition modeling (FDM). The development and optimization of composite thermoplastic filament feedstocks combining polypropylene and paraffin wax, followed by the 3D printing of the separator membranes is shown. A post-processing step, based on thermal induced phase separation (TIPS), is introduced to promote porosity formation through removal of the paraffin wax sacrificial phase within the 3D printed items. Separators with different polypropylene/paraffin wax ratios are developed and the impact on printability, mechanical strength, porosity, and electrochemical performances, is thoroughly discussed. X-ray micro-computed tomography is employed to assess the geometric fidelity and to detect printing defects in a complex 3D lattice structure. The performance of the 3D printed porous separators is also compared to a commercial separator. This pioneering research establishes a foundation for the creation of porous separators that can adapt to and conform into 3D printed battery architectures with novel form factors, and also creates opportunities for the use of FDM and TIPS for a wide range of applications that employ porous structures beyond the energy storage field.

3D printing↗

Mechanically and thermally robust microporous copolymer separators for lithium ion batteries

Next generation, multifunctional separators can enhance energy storage, power, and safety performance of lithium ion batteries but must be simple to fabricate and incorporate with existing roll-to-roll manufacturing. Here, this study presents a strategy to facilely prepare these separators using UV-initiated polymerization-induced phase separation (PIPS), wherein microporous polymer separators are fabricated directly from constituent monomers and ethylene carbonate (EC) porogen. This enables a wide compositional design space as co-monomers with specific chemical functionality can be readily incorporated into the PIPS precursor mixture. Herein, 1,4-butanediol diacrylate (BDDA) was copolymerized with poly(ethylene glycol) diacrylate (PEGDA) to increase the acrylate conversion in the photopolymerization and improve mechanical properties. By tuning the ratio of PEGDA and EC, separators with high porosity (41.3%) and effective ionic conductivity (2.09 mS cm –1 ) were prepared. Inclusion of PEGDA was essential to increasing the elastic modulus to > 345 MPa, which is required for cell assembly by roll-to-roll manufacturing. All separators prepared were shown to enable reversible cycling of lithium metal/LiNi 0.5 Mn 0.3 Co 0.2 O 2 half-cells for 100 cycles. Unlike conventional polyolefin separators, which were shown to melt at 160 °C and shrink by up to 29.8% at elevated temperatures, the PIPS separators possess exceptional, safety-enhancing thermomechanical properties, undergoing no phase transitions or thermal shrinkage.

25 ENERGY STORAGE↗