Search NASA⌕ Search

SEARCH · Search NASA

Results for “Isotopes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Proton-hole states in the N=30 neutron-rich {sup 49}K isotope.

Excited states in the N=30 neutron-rich isotope {sup 49}K have been studied using multinucleon transfer reactions with thin targets and the PRISMA-CLARA spectrometer combined with thick-target {gamma}-coincidence data from Gammasphere. The d{sub 3/2} proton-hole state is located 92 keV above the s{sub 1/2} ground state, and the proton-particle f{sub 7/2} state is suggested at 2104 keV. Three other levels are established as involving the coupling to 2{sup +} of two neutrons above the N=28 shell. The measured or estimated lifetimes served to reinforce the interpretation of the observed level structure, which is found to be in satisfactory agreement with shell-model calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Carbonate clumped isotope analysis (Δ 47 ) of 21 carbonate standards determined via gas‐source isotope‐ratio mass spectrometry on four instrumental configurations using carbonate‐based standardization and multiyear data sets

Rationale Clumped isotope geochemistry examines the pairing or clumping of heavy isotopes in molecules and provides information about the thermodynamic and kinetic controls on their formation. The first clumped isotope measurements of carbonate minerals were first published 15 years ago, and since then, interlaboratory offsets have been observed, and laboratory and community practices for measurement, data analysis, and instrumentation have evolved. Here we briefly review historical and recent developments for measurements, share Tripati Lab practices for four different instrument configurations, test a recently published proposal for carbonate‐based standardization on multiple instruments using multi‐year data sets, and report values for 21 different carbonate standards that allow for recalculations of previously published data sets. Methods We examine data from 4628 standard measurements on Thermo MAT 253 and Nu Perspective IS mass spectrometers, using a common acid bath (90°C) and small‐sample (70°C) individual reaction vessels. Each configuration was investigated by treating some standards as anchors (working standards) and the remainder as unknowns (consistency standards). Results We show that different acid digestion systems and mass spectrometer models yield indistinguishable results when instrument drift is well characterized. For linearity correction, mixed gas‐and‐carbonate standardization or carbonate‐only standardization yields similar results. No difference is observed in the use of three or eight working standards for the construction of transfer functions. Conclusions We show that all configurations yield similar results if instrument drift is robustly characterized and validate a recent proposal for carbonate‐based standardization using large multiyear data sets. Δ 47 values are reported for 21 carbonate standards on both the absolute reference frame (ARF; also refered to as the Carbon Dioxide Equilibrated Scale or CDES) and the new InterCarb‐Carbon Dioxide Equilibrium Scale (I‐CDES) reference frame, facilitating intercomparison of data from a diversity of labs and instrument configurations and restandardization of a broad range of sample sets between 2006, when the first carbonate measurements were published, and the present.

58 GEOSCIENCES↗

Deuterium isotope effects in polymerization of benzene under pressure

The enormous versatility in the properties of carbon materials depends on the content of the sp 2 and sp 3 covalent bonds. Under compression, if intermolecular distances cross a critical threshold, then unsaturated hydrocarbons gradually transform to saturated carbon polymers. However, the mechanism of polymerization, even for benzene, the simplest aromatic hydrocarbon, is still not understood. We used high-pressure synchrotron X-ray, neutron diffraction, and micro-Raman spectroscopy together with density functional calculations to investigate the isotope effects in benzene isotopologues C 6 H 6 and C 6 D 6 up to 46.0 GPa. Raman spectra of polymeric products recovered from comparable pressures show the progression of polymerization exhibiting a pronounced kinetic isotope effect. Kinetically retarded reactions in C 6 D 6 shed light on the mechanism of polymerization of benzene. Lastly, we find that C 6 D 6 -derived products recovered from P < 35 GPa actively react with moisture, forming polymers with higher sp 3 hydrogen contents. Significant isotopic shift (≥7 GPa) in persistence of Bragg reflections of C 6 D 6 is observed.

36 MATERIALS SCIENCE↗

Quantification and purification of isotopic contamination at the ReAccelerator of the Facility for Rare Isotope Beams

At the ReAccelerator within the Facility for Rare Isotope Beams, a combination of an interchangeable aluminum foil and a silicon detector was developed to quantify isobaric contamination in rare isotope beams. The device is simple to operate and is now used routinely. In this article, we describe the system and show an application of the device to determine the level of contamination of an Si-32 rare isotope beam by stable S-32. In addition, we describe how the new diagnostic device helped confirm an enhancement of the beam purity prior to beam delivery to experiments.

Instruments & Instrumentation↗

Ne ISOTOPES IN INDIVIDUAL PRESOLAR GRAPHITE GRAINS FROM THE MURCHISON METEORITE TOGETHER WITH He, C, O, Mg-Al ISOTOPIC ANALYSES AS TRACERS OF THEIR ORIGINS

Ne isotopes measured in individual presolar graphite grains, solid samples of extinct stars preserved in primitive meteorites, provide information on the type of stellar sources of the grains and on nucleosynthetic mixing and ion-trapping processes which were operating. We present Ne and He isotope analyses of single presolar graphite grains from the KFB1 density fraction extracted from the carbonaceous chondrite Murchison. In addition, we measured isotopes of C, O, and Mg-Al with the NanoSIMS ion microprobe to better constrain the origin of the grains. Eleven out of 51 presolar graphite grains contain nucleosynthetic {sup 22}Ne above our detection limit. This fraction of {sup 22}Ne-rich grains is similar to the one reported by Nichols et al. although we have a lower {sup 22}Ne detection limit. We detected rare He-shell {sup 20}Ne in one {sup 22}Ne-rich grain and obtained the {sup 20}Ne/{sup 22}Ne ratio (0.03 {+-} 0.02) of the He-shell of an Asymptotic Giant Branch (AGB) star with 1.5-2 M {sub sun} and subsolar metallicity. We also detected {sup 4}He in this grain, while in the other grains, which originally acquired He, He-loss seems to be significant. We found unequivocal evidence for radiogenic {sup 22}Ne (Ne-R) in another graphite grain, which likely condensed in a core-collapse supernova and which incorporated live radioactive {sup 22}Na (t {sub 1/2} = 2.6 yr). For the other grains, a clear assignment to a stellar source is more difficult to make. Putative stellar sources are supernovae, AGB stars, born-again AGB stars, J-type carbon stars, and CO novae.

79 ASTRONOMY AND ASTROPHYSICS↗

Isotope shifts in francium isotopes 206-213 Fr and 221 Fr

We present the isotope shifts of the 7 s 1/2 to 7 p 1/2 transition for francium isotopes ²⁰⁶⁻²¹³Fr with reference to ²²¹Fr collected from two experimental periods. The shifts are measured on a sample of atoms prepared within a magneto-optical trap by a fast sweep of radio-frequency sidebands applied to a carrier laser. King plot analysis, which includes literature values for 7 s 1/2 to 7 p 3/2 isotope shifts, provides a field shift constant ratio of 1.0520(10) and a difference between the specific mass shift constants of 170(100) GHz amu between the D₁ and D₂ transitions, of sufficient precision to differentiate between ab initio calculations.

Collister, R.↗

Acceleration of uranium beam to record power of 10.4 kW and observation of new isotopes at Facility for Rare Isotope Beams

The Facility for Rare Isotope Beams (FRIB) is a major nuclear physics facility for research with fast, stopped, and reaccelerated beams that was successfully commissioned in May 2022. A key capability of FRIB is the production of an acceleration of the uranium beam, but this capability requires the facility to work at the design limits of the lowest charge-to-mass ratio and the highest power density on the beam intercepting devices. This paper presents techniques for overcoming the significant challenges in accelerating the uranium beam, culminating in the demonstration of 10.4 kW on target, and the discovery of three new isotopes. The high-power uranium beam enabled us to produce and identify G 88 a , A 93 s , and S 96 e , within the first 24 h of operation. The successful uranium operation at FRIB sets a new record for accelerated uranium beam power above 10 kW and opens a new avenue of research with rare isotopes. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Striking isotope effect on the metallization phase lines of liquid hydrogen and deuterium

Liquid atomic metallic hydrogen is the simplest, lightest, and most abundant of all liquid metals. The importance of nucleon motions or ion dynamics can be studied by comparing the metallization phase lines of the dissociative insulator-metal transitions of hydrogen and deuterium. We use static compression to study the optical properties of dense liquid metallic deuterium in the pressure region of 1.2–1.7 Mbars and measured temperatures up to ~3000 K. At the same pressure (density) for the two isotopes, the phase lines of this transition reveal a prominent isotopic shift of ~700 K. Furthermore, our paper shows the importance of quantum nuclear effects in the metallization transition and conduction properties in dense hydrogen isotopes at conditions of giant planetary interiors and provides an invaluable benchmark for ab initio calculations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Real-time standoff detection of nitrogen isotopes in ammonia plumes using a swept external cavity quantum cascade laser

A swept-wavelength external cavity quantum cascade laser is used to measure time-resolved 15NH3 and 14NH3 concentrations and isotope ratios in a turbulent plume source located at 10 m standoff distance. Measurements show excellent agreement with expected values of isotope ratios for samples with natural and enriched 15N abundance. Detection sensitivity of 150 ppb*m is demonstrated for a 50 ms measurement interval, improving to 10 ppb*m with 10 s averaging, with isotopic precision as good as 0.8%.

Phillips, Mark C.↗

A non-mass-dependent oxygen isotope effect in the production of ozone from molecular oxygen - The role of molecular symmetry in isotope chemistry

It was previously reported that the reaction products from the synthesis of ozone in an electric discharge through molecular oxygen display a nonmass-dependent (NoMaDic) oxygen isotope effect. In this paper, a detailed characterization of the isotope effect, including the effect of molecular oxygen pressure, and the presence of a chemically inert third body (helium), is reported. The NoMaDic effect is due to an isotopically selective stabilization of the O3 formation reaction intermediate, possibly resulting from the ability of the different isotopomers to exhibit different molecular symmetries.

Heidenreich, J. E., III↗

A ROBUST ABSOLUTE DETECTION EFFICIENCY CALIBRATION METHOD UTILIZING BETA/GAMMA COINCIDENCE SIGNATURES AND ISOTOPICALLY PURIFIED NEUTRON ACTIVATED RADIOXENON ISOTOPES

Efforts to calibrate the absolute efficiency of gas cell radiations detectors have utilized a number of methodologies which allow adequate calibration but are time consuming and prone to a host of difficult-to-determine uncertainties. A method that extrapolates the total source strength from the measured beta and gamma gated beta coincidence signal was developed in the 1960’s and 1970’s. It has become clear that it is possible to achieve more consistent results across a range of isotopes and a range of activities using this method. Even more compelling is the ease with which this process can be used on routine samples to determine the total activity present in the detector. Additionally, recent advances in the generation of isotopically pure radioxenon samples of Xe-131m, Xe-133, and Xe-135 have allowed these measurement techniques to achieve much better results than would have been possible before when using mixed isotopic radioxenon source. This paper will discuss the beta/gamma absolute detection efficiency technique that utilizes several of the beta-gamma decay signatures to more precisely determine the beta and gamma efficiencies. It will than compare these results with other methods using pure sources of Xe-133, Xe-131m, and Xe-135 and a Xe-133/Xe-133m mix.

Beta-gamma↗

Dual isotope notch observer for isotope identification, assay and imaging with mono-energetic gamma-ray sources

A dual isotope notch observer for isotope identification, assay and imaging with mono-energetic gamma-ray sources includes a detector arrangement consists of three detectors downstream from the object under observation. The latter detector, which operates as a beam monitor, is an integrating detector that monitors the total beam power arriving at its surface. The first detector and the middle detector each include an integrating detector surrounding a foil. The foils of these two detectors are made of the same atomic material, but each foil is a different isotope, e.g., the first foil may comprise U235 and second foil may comprise U238. The integrating detectors surrounding these pieces of foil measure the total power scattered from the foil and can be similar in composition to the final beam monitor. Non-resonant photons will, after calibration, scatter equally from both foils.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In situ monitoring of H and O stable isotopes in soil water reveals ecohydrologic dynamics in managed soil systems [Urban ecohydrologic dynamics revealed by in situ monitoring of H and O stable isotopes in soil water]

The water cycle in urban and hydrologically managed settings is subject to perturbations that are dynamic on small spatial and temporal scales; the effects of which may be especially profound in soils. We deploy a membrane inlet-based laser spectroscopy system in conjunction with soil moisture and temperature sensors to monitor soil water dynamics and H and O stable isotope ratios (δ 2 H and δ 18 O values) in a seasonally irrigated urban-landscaped garden soil over the course of 9 months between the cessation of irrigation in the autumn and the onset of irrigation through the summer. Here, we find that soil water δ 2 H and δ 18 O values predominately reflect seasonal precipitation and irrigation inputs. A comparison of total soil water by cryogenic extraction and mobile soil water measured by in situ water vapor probes reveals that initial infiltration events after long periods of soil drying (the autumn season in this case) emplace water into the soil matrix that is not easily replaced by, or mixed with, successive pulses of infiltrating soil water. Tree stem xylem water H and O stable isotope composition did not match that of available water sources. Our findings suggest that partitioning of soil water into mobile and immobile “pools” and resulting ecohydrologic separation may occur in engineered and hydrologically managed soils and not be limited to natural settings. Furthermore, the laser spectroscopy method detailed here has potential to yield insights in a variety of critical zone and vadose zone studies, potential that is heightened by the simplicity and portability of the system.

07 ISOTOPE AND RADIATION SOURCES↗

Recent advances in SRS on hydrogen isotope separation using thermal cycling absorption process

TCAP (Thermal Cycling Absorption Process) is a gas chromatograph in principle using palladium in the column packing, but it is unique in the fact that the carrier gas, hydrogen, is being isotopically separated and the system is operated in a semi-continuous manner. TCAP units are used to purify tritium. The recent TCAP advances at Savannah River Site (SRS) include compressor-free concept for heating/cooling, push and pull separation using an active inverse column, and compact column design. The new developments allow significantly higher throughput and better reliability from 1/10 of the current production system's footprint while consuming 60% less energy. Various versions are derived in the meantime for external customers to be used in fusion energy projects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of hydrogen isotope exchange methodology on adsorbents for tritium removal

The Savannah River National Laboratory has demonstrated a potential process that can be used to remove tritium from tritiated water using Pt-catalyzed molecular sieves. The process is an elemental isotope exchange process in which H{sub 2} (when flowed through the molecular sieves) will exchange with the adsorbed water, D{sub 2}O, leaving H{sub 2}O adsorbed on the molecular sieves. Various formulations of catalyzed molecular sieve material were prepared using two different techniques, Pt-implantation and Pt-ion exchange. This technology has been demonstrated for a protium (H) and deuterium (D) system, but can also be used for the removal of tritium from contaminated water (T{sub 2}O, HTO, and DTO) using D{sub 2} (or H{sub 2}). (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗