Search NASA⌕ Search

SEARCH · Search NASA

Results for “JEFFERSON LAB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Recent Results from Jefferson Lab RSS Spin Physics Program

The spin physics program in Jefferson Lab's Hall C concentrates on high precision and high resolution studies of the nucleon spin structure that can be extracted from inclusive polarized scattering experiments. The Resonances Spin Structure - RSS experiment has measured nucleon spin structure functions in the resonances region at an intermediate four-momentum transfer Q{sup 2}{approx_equal}1.3 GeV{sup 2}. The polarized target in Hall C could be polarized longitudinally and transversely, allowing extraction of both spin-dependent structure functions g{sub 1} and g{sub 2}. Results on proton and deuteron spin asymmetries A{sub 1} and A{sub 2}, and spin structure functions g{sub 1} and g{sub 2}, are presented here.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance and Commissioning of the BigBite Timing Hodoscope for Nucleon Form Factor Measurements at Jefferson Lab

The BigBite Timing Hodoscope detector is the primary subject of this thesis. The Super BigBite Spectrometer is a Jefferson Lab Hall A Collaboration project that has and will continue to measure nucleon electromagnetic form factors. This spectrometer includes the Timing Hodoscope which provides high resolution particle timing data for scattered electrons in the electron arm of BigBite. The Timing Hodoscope utilizes 90, 25 × 25 × 600 mm3 scintillator bars stacked on top of each other to form a single detector plane, and these bars are connected to 180 photo-multiplier tubes via light guides. Particles collide with the scintillating material creating a shower of optical photons and these particle events in the bars are collected to generate signals that are readout by the data acquisition (DAQ) electronics. NINO ASIC amplifier-discriminator cards output signals from the photo-multiplier tubes into analogue and logic signals, which are sent to analogue-to-digital (ADC) and time-to-digital (TDC) converter data acquisition readout modules. This data is then used for analysis of the detector. The focus of this thesis is the construction, commissioning, calibration, and performance of the BigBite Timing Hodoscope before and during the first of five nucleon electromagnetic form factor experiments at Jefferson Lab Hall A. Before the neutron magnetic form factor, G n M, experiment, cosmic ray data was collected during commissioning to confirm proper operation of the Timing Hodoscope electronics by observing the ADC and TDC data. Commissioning studies for charge normalization, gain matching, and other ADC and TDC detector data variables were performed before moving the detector into Hall A. Following installation in Hall A, several calibration studies were implemented to fine-tune the detector in preparation for use in the experiment. The calibration studies included analysis of timing cuts, TDC alignment, the time-walk effect, time difference offsets, and scintillator velocity corrections. Once the Timing Hodoscope was well-calibrated, data-taking during the experiment commenced and the beam-on-target data was used to characterize the Timing Hodoscope performance during the G n M experiment run-time. The performance analysis included studies observing energy deposit, cluster size, rates, accidentals, pile-up, tracking efficiency, position resolution, and time resolution. After application of physics cuts to ensure a data set comprised of particle tracks corresponding to elastic electrons, which is the main data of interest for measurement of G n M, the Timing Hodoscope is shown on average across all kinematic settings to have a >98% tracking efficiency, a position resolution of 4-6 cm in the non-dispersive plane and 1.5-2 cm in the dispersive plane, and a time resolution of 500-750 ps. These performance results are compared to a GEANT4 based performance simulation of the BigBite Timing Hodoscope for reference, showing to what degree the measured performance values match those taken from the simulation.

Marinaro, Ralph↗

Performance of the Pair Spectrometer in Hall D at Jefferson Lab

This article describes the performance of the pair spectrometer installed in experimental Hall D at Jefferson Lab and its successfully operation in multiple experiments with the GlueX detector. The primary purpose of the pair spectrometer is the precise determination of the flux of beam photons incident on the GlueX target, a critical input for physics analyses such as absolute cross-section measurements. The photon energy spectrum is determined by reconstructing electron–positron pairs produced in a thin converter inserted into the photon beam. The spectrometer is integrated into the GlueX trigger system, whose electronics enable continuous real-time monitoring of the photon flux and the recording of e+e- pair candidates for offline analysis. In addition, the pair spectrometer provides a versatile test facility for evaluating calorimeter prototypes using leptons with well-defined energies produced via electromagnetic pair production.

Somov, Alexander [Jefferson Lab]↗

Nuclear Physics Research at Jefferson Lab

The Florida International University (FIU) experimental nuclear physics group consists of four to five faculty, four to eight graduate students, at times one postdoctoral scholar, and several undergraduate students. Our research is mainly conducted at Jefferson Lab's Continuous Electron Accelerator Beam Facility. We are studying the electroprodcution of strangeness and also the interaction of strange baryons, hyperons, with nuclear matter; the effects of two-photon exchange on nuclear form factor measurements; the short range correlations in nuclei; and the production of exotic mesons. Over the entire period of this project, members of the group have been leading the data acquisition and analysis efforts as co-spokespersons of 12 Jefferson Lab experiments, as well as contributed to the efforts of the broader JLab user community. This has resulted in the publication of over 300 papers in peer reviewed journals and conference proceedings. Twelve students received their Ph.D. and four their M.S. based on analysis of data collected during this project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of the SRF Driver ERL for the Jefferson Lab UV FEL

We describe the design of the SRF Energy-Recovering Linac (ERL) providing the CW electron drive beam at the Jefferson Lab UV FEL. Based on the same 135 MeV linear accelerator as and sharing portions of the recirculator with the Jefferson Lab 10 kW IR Upgrade FEL, the UV driver ERL uses a novel bypass geometry to provide transverse phase space control, bunch length compression, and nonlinear aberration compensation (including correction of RF curvature effects) without the use of magnetic chicanes or harmonic RF. Stringent phase space requirements at the wiggler, low beam energy, high beam current, and use of a pre-existing facility and legacy hardware subject the design to numerous constraints. These are imposed not only by the need for both transverse and longitudinal phase space management, but also by the potential impact of collective phenomena (space charge, wakefields, beam break-up (BBU), and coherent synchrotron radiation (CSR)), and by interactions between the FEL and the accelerator RF system. This report addresses these issues and presents the accelerator design solution that is now in operation.

43 PARTICLE ACCELERATORS↗

Latest results from FROST at Jefferson Lab

The spectrum of broad and overlapping nucleon excitations can be greatly clarified by use of a polarized photon beam incident on a polarized target in meson photoproduction experiments. At Jefferson Lab, a program of such measurements has made use of the Jefferson Lab FROzen Spin Target (FROST). An overview of preliminary results are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characteristics and fabrication of a 499 MHz superconducting deflecting cavity for the Jefferson Lab 12 geV Upgrade

A 499 MHz parallel bar superconducting deflecting cavity has been designed and optimized for a possible implementation at the Jefferson Lab. Previously the mechanical analysis, mainly stress, was performed. Since then pressure sensitivity was studied further and the cavity parts were fabricated. The prototype cavity is not completed due to the renovation at Jefferson Lab which resulted in the temporary shutdown of the electron beam welding facility. This paper will present the analysis results and facts encountered during fabrication. The unique geometry of the cavity and its required mechanical strength present interesting manufacturing challenges.

43 PARTICLE ACCELERATORS↗

New CTEQ-Jefferson Lab (CJ) analysis of parton distributions

We present preliminary results of a new global QCD analysis of PDFs from the CTEQ-Jefferson Lab Collaboration (dubbed "CJ15"), which includes several new data sets and recent theoretical developments. In particular, we study the constraints from new D0 data on *W* boson asymmetries on the *d/u* PDF ratio at large *x*, and, indirectly, on the models of nuclear corrections in the deuteron. The analysis also considers for the first time the impact of Jefferson Lab data on the free neutron/deuteron structure function ratio at large *x*, and reanalyzes the light antiquark asymmetry in the proton from Drell-Yan data using more flexible parametrizations and nuclear corrections to deuterium cross sections. The results provide a new set of baseline PDFs which can be used to more reliably calibrate the effect of future data from the LHC.

Keppel, Cynthia↗

New CTEQ-Jefferson Lab (CJ15) Analysis of Parton Distributions

We present the results of a new global QCD analysis of PDFs from the CTEQ-Jefferson Lab collaboration (dubbed "CJ15"), which includes several new data sets and recent theoretical developments. In particular, we study the constraints from new D0 data on W boson asymmetries on the d/u PDF ratio at large x, and, indirectly, on the models of nuclear corrections in the deuteron. The analysis also considers for the first time the impact of Jefferson Lab data on the free neutron/deuteron structure function ratio at large x, and reanalyzes the light antiquark asymmetry in the proton from Drell-Yan data using more flexible parametrizations and nuclear corrections to deuterium cross sections. The results provide a new set of baseline PDFs which can be used to more reliably calibrate the effects of future data from the LHC.

Melnitchouk, W.↗

Nucleon and Nuclear Structure Studies in Electroproduction with the CLAS Detector at Jefferson Lab

A diverse program for studying the structure of nucleons and nuclei is underway using the CEBAF Large Acceptance Spectrometer (CLAS) at Jefferson Lab. A wealth of data has been obtained in inclusive, semi-inclusive, and exclusive electroproduction reactions using a variety of unpolarized and polarized beams and targets. The results include studies of excited nucleon states, measurements of nucleon, proton and neutron Form Factors (FFs), Parton Distribution Functions (PDFs), Transverse Momentum Distributions (TMDs), and Generalized Parton Distributions (GPDs), as well as Short Range Correlations (SRCs) in nuclei and Color Transparency phenomena. Jefferson Lab's electron accelerator, CEBAF, doubled its energy to 12~GeV and the upgrade of the experimental equipment is near completion in the experimental halls. The upgraded CLAS detector, CLAS12, enables execution of a broader physics program, with the main focus on uncovering the TMDs and GPDs using semi-inclusive and exclusive reactions in a new kinematic domain. In this talk, an overview of the CLAS electroproduction measurements with 6~GeV CEBAF and prospects of nucleon and nuclear structure studies with the 12~GeV machine and the CLAS12 detector will be discussed.

Stepanyan, Stepan↗

Large area, high spatial resolution tracker for new generation of high luminosity experiments in Hall A at Jefferson Lab

In 2014 the CEBAF electron accelerator at Jefferson Lab (JLab) will deliver a longitudinally polarized (up to 85%), high intensity (up to 100 μA) beam with maximum energy of 12 GeV, twice the present value. To exploit the new opportunities that the energy upgrade will offer, a new spectrometer (Super BigBite - SBS) is under development, featuring very forward angle, large acceptance and ability to operate in high luminosity environment. The tracking system of SBS will consist of large area (40×150 cm2 and 50×200 cm2), high spatial resolution (better than 100 μm) chambers based on the GEM technology and 2 small (10×20 cm) Silicon Strip Detector planes. The design of the GEM chambers and its sub-components such as the readout electronics is resented here.

43 PARTICLE ACCELERATORS↗

Final Assembly and Factory Testing of the Jefferson Lab SHMS Spectrometer Quadrupole and Dipole Superconducting Magnets

Jefferson Lab is constructing an 11 Gev/c electron spectrometer called the Super High Momentum Spectrometer (SHMS) as part of the 12 GeV JLAB upgrade for experimental Hall C. Three of the five superconducting(SC) SHMS magnets are under construction at SigmaPhi in Vannes France as a result of an international competition for design and fabrication. The three magnets Q2 and Q3 60 cm bore quadrupoles and the 60 cm warm bore dipole are complete or near complete and have many design features in common. All three magnets share a common superconductor, collaring system, cryostat design, cold to warm support, cryogenic interface, burnout resistant current leads, DC power supply, quench protection, instrumentation and controls. The three magnets are collared, installed in cryostats and welded up and in various stages of final testing. The Q2 quadrupole is due to ship from France to America in August arriving during this ASC conference and has passed all final hipot, leak and pressure tests. The dipole is in leak and pressure testing as of July 2016 while the Q3 quadrupole requires some outer vacuum vessel assembly. Delivery of the Q3 and Dipole magnets will follow the Q2 at about 1 month intervals. Lastly, factory testing have included hipot and electrical tests, magnetic tests at low field, mechanical alignments to center the coils, leak tests and ASME Code required pressure tests. Upon installation in Hall C at JLAB cold testing will commence.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transversely Polarized Solid Target for Hall B at Jefferson Lab

The physics program for Hall B at Jefferson Lab includes multiple, high-impact experiments scattering electrons from transversely polarized protons. These experiments will measure, for example, the Transverse Momentum Distributions and the Generalized Parton Distribution for protons, using, respectively, semi-inclusive deep inelastic scattering and deeply virtual Compton scattering. In this talk I will discuss the technical challenges to implementing a polarized solid-state target in the Hall B experimental environment, examine potential solutions, and describe the current status of the target design.

Keith, Christopher↗

Offline Computing for the GlueX Experiment at Jefferson Lab

The GlueX Experiment in Hall D at Jefferson Lab is scheduled to start commissioning in the Summer of 2015. The new detector will record events created with a new beamline that will deliver tagged, coherent bremsstrahlung photons with an endpoint of 11 GeV and a prominent coherent peak at 9 GeV. Reconstruction software will have to output both charged and neutral particles. To facilitate a partial wave analysis of final states, high-single particle efficiency will be required. The general approach to offline software will be presented, including resource requirements and technology choices.

Ito, Mark↗

Charged Track Reconstruction for GlueX at Jefferson Lab

The GlueX detector currently under construction at Jefferson Lab is a large acceptance device designed to facilitate the search for hybrid mesons. In order to accomplish this program, both photons and charged particles need to be reconstructed with high efficiency. Forward-going charged particles are detected in the Forward Drift Chambers while tracks exiting the target at angles greater than ?20 degrees are detected in the Central Drift Chamber. Hits in both sets of detectors are associated into track segments that are linked together to form track candidates. These candidates are fit using the Kalman Filter formalism. The track reconstruction sequence from track finding through track fitting will be described. Single-track efficiencies and resolutions will be presented. Results for simulated events containing multiple charged particles relevant for the GlueX physics program will also be presented.

Taylor, Simon↗

Recirculating Beam Breakup Study for the 12 GeV Upgrade at Jefferson Lab

Two new high gradient C100 cryomodules with a total of 16 new cavities were installed at the end of the CEBAF south linac during the 2011 summer shutdown as part of the 12-GeV upgrade project at Jefferson Lab. We surveyed the higher order modes (HOMs) of these cavities in the Jefferson Lab cryomodule test facility and CEBAF tunnel. We then studied recirculating beam breakup (BBU) in November 2011 to evaluate CEBAF low energy performance, measure transport optics, and evaluate BBU thresholds due to these HOMs. This paper discusses the experiment setup, cavity measurements, machine setup, optics measurements, and lower bounds on BBU thresholds by new cryomodules.

43 PARTICLE ACCELERATORS↗

AI Applications to Physics Experiments at Jefferson Lab

We survey how AI/ML is being deployed across Jefferson Lab's experimental and accelerator programs. In EPSCI, Hydra applies computer vision to automate real-time data-quality monitoring across all four experimental halls, replacing manual inspection of hundreds to thousands of histograms per shift. AIEC (AI Experiment Controls) uses ML to stabilize drift chamber gains and is now part of standard CEBAF production running, while AI Optimized Polarization (AIOP) targets autonomous control of polarized targets and photon beam angular alignment. In CASA, cavity fault classification models identify faulted cavities and trip types from waveform data with ~85% and ~78% agreement to labeled data, respectively, and are deployed in production; a separate effort applies LLMs and hybrid search to make the CEBAF operations logbook AI-ready. QCD-focused work includes transformer- and GAN-based generative models for particle-level event simulation, with distributed GAN training scaling studies on Polaris. Additional efforts span ML-on-FPGA for the EIC and a new Data Science Department coordinating anomaly detection, uncertainty quantification, and HPC-scalable ML lab-wide. Collectively, these projects illustrate AI's growing role in improving efficiency across JLab's nuclear physics mission.

Mei, Xinxin [Thomas Jefferson National Accelerator↗

Overview of the Jefferson Lab 12 GeV Experimental Program in Halls A,B, and C

The 11 GeV beam energy available in experimental Halls A, B, and C as part of the Jefferson Lab 12 GeV Upgrade, combined with the new equipment in those halls will provide a rich and diverse physics program. This program includes inclusive measurements used to constrain polarized and unpolarized quark distributions in nucleons, exclusive reactions to access nucleon and meson form factors and GPDs, semi-inclusive measurements aimed at constraining TMDs, as well as measurements from nuclei to provide further insight into the origins of Short Range Correlations and the EMC Effect. The experimental equipment was designed with the above program in mind and the three halls provide complementary capabilities. Magnetic focusing spectrometers in Hall C (the new SHMS and existing HMS) will provide precision separated and unseparated cross section measurements and ratios. The new large acceptance CLAS12 spectrometer in Hall B enables measurements over broad regions of phase space. In Hall A, the new SBS spectrometer, used in conjunction with the existing HRS or Big Bite spectrometers will provide access to very large Q2 and allow for measurements requiring both high luminosity and large acceptance. This talk will give an overview of the upcoming experimental program in Halls A,B, and C, in particular highlighting synergies between the hall programs, which will allow Jefferson Lab to maximize the science output its 12 GeV program.

Gaskell, David↗