At least 163 records · Page 9

Atomic beam system for laboratory simulation of upper atmosphere oxygen atom impact on STS surfaces

An atomic beam apparatus capable of producing a collimated beam of O atoms or other atmospheric species at the STS impact velocity of 8 km/s is described. A conventional ion beam charge transfer neutralization approach was adopted to produce the projectile beam. The prime considerations favoring this approach are: the ability to vary the velocity of the impacting species at will over a wide range on either side of the optimum required value of 8 km/s; and sample irradiation can be made with species other than O-atoms, such as O2, N, or N2.

Mahadevan, P.↗

Laboratory test methods for evaluating the fire response of aerospace materials

The test methods which were developed or evaluated were intended to serve as means of comparing materials on the basis of specific responses under specific sets of test conditions, using apparatus, facilities, and personnel that would be within the capabilities of perhaps the majority of laboratories. Priority was given to test methods which showed promise of addressing the pre-ignition state of a potential fire. These test methods were intended to indicate which materials may present more hazard than others under specific test conditions. These test methods are discussed and arranged according to the stage of a fire to which they are most relevant. Some observations of material performance which resulted from this work are also discussed.

Hilado, C. J.↗

Apparatus and methodology for fire gas characterization by means of animal exposure

While there is a great deal of information available from small-scale laboratory experiments and for relatively simple mixtures of gases, considerable uncertainty exists regarding appropriate bioassay techniques for the complex mixture of gases generated in full-scale fires. Apparatus and methodology have been developed based on current state of the art for determining the effects of fire gases in the critical first 10 minutes of a full-scale fire on laboratory animals. This information is presented for its potential value and use while further improvements are being made.

Marcussen, W. H.↗

Evaluation of the smoke density chamber as an apparatus for fire toxicity screening tests

The smoke density chamber is perhaps the most widely used apparatus for smoke measurements. Because of its availability, it has been proposed as an apparatus for evaluating fire toxicity. The standard apparatus and procedure were not found suitable for toxicity screening tests using laboratory animals, because not enough materials of interest produced animal mortality or even incapacitation under standard test conditions. With modifications, the chamber offers greater promise as a screening tool, but other tests specifically designed to measure relative toxicity may be more cost-effective. Where one-dimensional heat flux is a requirement, the chamber is the most suitable apparatus available. It should be improved in regard to visibility of animals and ease of cleaning.

Hilado, C. J.↗

X-Y alphanumeric character generator for oscilloscopes

A method and apparatus is disclosed by which any general purpose external trigger laboratory oscilloscope can be utilized to display alphanumeric characters. Each character to be displayed is composed of a plurality of segments appearing at various segment positions in various segment rows to define a conventional matrix. In between character segments to be displayed, or when no display is desired, the trace is effectively blanked by a vertical clamping voltage so as to position the oscilloscope trace in an off-screen position. The clamping technique of the invention, i.e., biasing the oscilloscope trace to an off-screen position when no character segment is to be displayed; it eliminates the necessity of providing Z-axis modulation to effect blanking.

Lokerson, D. C.↗

A simple laboratory method for determining ignitability of materials

A simple laboratory method for determining ignitability of materials is described. The apparatus consists of a Mellen high-flux heater capable of producing up to 13 W/sq cm heat flux, a Medtherm water-cooled radiometer for measuring heat flux, a mounting frame to hold all components in proper position, and specimen holders of the type used for the NBS smoke test. Time to ignition at different heat flux levels is recorded. Test results are presented for a variety of materials.

Hilado, C. J.↗

Apparatus Circulates Sterilizing Gas

Apparatus circulates sterilizing gas containing ethylene oxide and chlorofluorocarbon through laboratory or medical equipment. Confines sterilizing gas, circulating it only through parts to be treated. Consists of two units. One delivers ethylene oxide/chlorofluorocarbon gas mixture and removes gas after treatment. Other warms, humidifies, and circulates gas through equipment to be treated. Process provides reliable sterilization with negligible residual toxicity from ethylene oxide. Particularly suitable for sterilization of interiors of bioreactors, heart/lung machines, dialyzers, or other equipment including complicated tubing.

Cross, John H.↗

Concepts related to the origin of the genetic apparatus.

Since the genetic apparatus is composed of nucleic acid and protein, the origin of the apparatus involves the origin of polyaminoacids and of polynucleotides, separately or together. Laboratory models for the origins of the separate macromolecular types are considered. The origin of their joint synthesis, believed to have been necessary at a later stage, is also discussed. Proteins and nucleic acids appear to have definite relationships with each other in three major contemporary biological systems, including chromatin, ribosomes, and the protein synthesizing system using nucleic acid templates. Stages considered in connection with the flow of information in the early evolution of the apparatus are environment, protoprotein, protein, RNA, and DNA.

Lacey, J. C., Jr.↗

Laboratory verification respiratory measurements. IMBLMS phase B.4, appendix C, section 13

The B-4 IMBLMS preliminary design of the respiratory measurement element includes certain techniques and apparatus which are quite different from those included in the B-3 version previously delivered to NASA-MSC. A working model was constructed in the laboratory to prove the feasibility of certain key features. The most critical of these is the capability of switching sample gases into the mass spectrometer from two different sources during a single breath cycle. Results proved the feasibility of all of the concepts which were tested, and certain refinements and improvements were included, as well.

Source record↗

Acceleration Environment of the International Space Station

Measurement of the microgravity acceleration environment on the International Space Station has been accomplished by two accelerometer systems since 2001. The Microgravity Acceleration Measurement System records the quasi-steady microgravity environment, including the influences of aerodynamic drag, vehicle rotation, and venting effects. Measurement of the vibratory/transient regime, comprised of vehicle, crew, and equipment disturbances, has been accomplished by the Space Acceleration Measurement System-II. Until the arrival of the Columbus Orbital Facility and the Japanese Experiment Module, the location of these sensors, and therefore, the measurement of the microgravity acceleration environment, has been limited to within the United States Laboratory. Japanese Aerospace Exploration Agency has developed a vibratory acceleration measurement system called the Microgravity Measurement Apparatus which will be deployed within the Japanese Experiment Module to make distributed measurements of the Japanese Experiment Module's vibratory acceleration environment. Two Space Acceleration Measurement System sensors from the United States Laboratory will be re-deployed to support vibratory acceleration data measurement within the Columbus Orbital Facility. The additional measurement opportunities resulting from the arrival of these new laboratories allows Principal Investigators with facilities located in these International Space Station research laboratories to obtain microgravity acceleration data in support of their sensitive experiments. The Principal Investigator Microgravity Services project, at NASA Glenn Research Center, in Cleveland, Ohio, has supported acceleration measurement systems and the microgravity scientific community through the processing, characterization, distribution, and archival of the microgravity acceleration data obtained from the International Space Station acceleration measurement systems. This paper summarizes the PIMS capabilities available to the International Space Station scientific community, introduces plans for extending microgravity analysis results to the newly arrived scientific laboratories, and provides summary information for known microgravity environment disturbers.

McPherson, Kevin↗

The Future Polarized Target Program at Jefferson Lab

Polarized targets have played a crucial role in Jefferson Lab's exploration of nuclear structure over the past four decades. The three original experimental halls have seen 19 separate installations of polarized solid or gas targets for use in the particle physics scattering experiments, and this trend will continue in the next decade. Five polarized target systems are in preparation for use at JLab in the coming years. Hall B will see the use of two solid polarized targets, one longitudinally polarized to the beam, the other transversely, as well as a novel 3He gas polarized target. In Hall C, new experiments will augment the tensor polarization in dynamically polarized solids. Plans are under development to bring a polarized solid target to Jefferson Lab's photon beam hall, Hall D, for the first time. To support these efforts, the JLab polarized target group is building a test laboratory to develop dynamic nuclear polarization techniques, as well as an apparatus to irradiate target material using electrons from JLab's injector test facility. In this talk, we will explore the development progress and plans for each of these efforts.

Maxwell, James [Thomas Jefferson National Accelera↗

Ultrastructure of the root cap of Arabidopsis Thaliana L. Heynh under spaceflight conditions

Peculiarities of the ultrastructural organization of Arabidopsis root cap cells grown from the stage of two cotyledonous leaves in the Svetoblok-1 apparatus aboard the Salyut 6 research orbital station and in the laboratory are assessed. It is established that under conditions of real space flight vacuolization of the root cap cells increses considerably compared to the control variant. Changes in the topography and ulstrastructure of amyloplasts as well as lysis of cell walls are observed in the material under study. An assumption is advanced on analogous cell responses observed at the ultrastructural level to weightlessness and clinostatic conditions.

Source record↗

High-pressure ruby and diamond fluorescence - Observations at 0.21 to 0.55 terapascal

A diamond-anvil, high-pressure apparatus was used to extend the upper pressure limit of static laboratory experiments. Shifts of the R1 strong fluorescent line of ruby were observed that correspond to static pressures of 0.21 to 0.55 terapascal (2.1 to 5.5 megabars) at 25 C. Sensitive spectroscopic techniques in the pressure range 0.15 to 0.28 terapascal were used to observe ruby and diamond fluorescence separately; these two fluorescent emissions overlap strongly at high pressures. At pressures greater than approximately 0.28 terapascal, the diamond fluorescence diminished and the ruby fluorescence reappeared strongly. Pressure was determined by extrapolation of the calibrated shift of the ruby R1 line.

Xu, J. A.↗

Laboratory calibration of field reflectance panels

A method used for calibrating field reflectance panels in the visible and shortwave infrared wavelength range is described. The directional reflectance factor of painted barium sulfate (BaSO4) panels is determined. The reference for this method is the hemispherical reflectance of pressed polytetrafluoroethylene (halon) powder prepared according to National Bureau of Standards (NBS) directions. The panels and a radiometer are mounted on rotation stages to measure the reflectance factor at different incidence and view angles. The sensor can be any laboratory or field filter radiometer small enough to mount on the apparatus. The method is used to measure the reflectance factors of halon and BaSO4 panels between 0.45 and 0.85 micrometers. These reflectance factors are compared to those measured by a field apparatus. The results agree to within 0.013 in reflectance at incidence angles between 15 and 75 degrees.

Biggar, S. F.↗

Frequency-scanning particle size spectrometer

A particle size spectrometer having a fixed field of view within the forward light scattering cone at an angle .theta..sub.s between approximately 100 and 200 minutes of arc (preferably at 150 minutes), a spectral range extending approximately from 0.2 to 4.0 inverse micrometers (.mu.m.sup.-1), and a spectral resolution between about 0.1 and 0.2 .mu.m.sup.-1 (preferably toward the lower end of this range of spectral resolution), is employed to determine the distribution of particle sizes, independently of the chemical composition of the particles, from measurements of incident light, I.sub.o, at each frequency, .sigma. (=1/.lambda.), and scattered light, I(.sigma.), according to the equation: ##EQU1## where l=2.pi.sin.theta., .theta. being the fixed viewing angle .theta..sub.s at which scattered light is measured, r is particle size, .sigma. is the reciprocal of wavelength, J.sub.1 is a Bessel function of first kind and order unity, Y.sub.1 is a Bessel function of second kind and order unity. The quantity, I.sub..sigma., is the ratio of scattered light to incident light at each frequency interval. The apparatus is a passive remote sensor that can be used in laboratories, field stations, flying aircrafts and airships, and on board an orbiting satellite.

Fymat, Alain L.↗

Demonstration of a Pyrotechnic Bolt-Retractor System

A paper describes a demonstration of the X-38 bolt-retractor system (BRS) on a spacecraft-simulating apparatus, called the Large Mobility Base, in NASA's Flight Robotics Laboratory (FRL). The BRS design was proven safe by testing in NASA's Pyrotechnic Shock Facility (PSF) before being demonstrated in the FRL. The paper describes the BRS, FRL, PSF, and interface hardware. Information on the bolt-retraction time and spacecraft-simulator acceleration, and an analysis of forces, are presented. The purpose of the demonstration was to show the capability of the FRL for testing of the use of pyrotechnics to separate stages of a spacecraft. Although a formal test was not performed because of schedule and budget constraints, the data in the report show that the BRS is a successful design concept and the FRL is suitable for future separation tests.

Johnston, Nick↗

A simple laboratory method for determining flash fire propensity of materials

A simple laboratory method for determining flash fire propensity of materials is described. The apparatus consists of a tube furnace and a combustion tube. The ignition source can be a wooded match but the hot pyrolysis tube itself may be the most suitable ignition source. Test results are presented for various materials including polyethylene, polystyrene, polycarbonate, and polyurethane and polychloroprene flexible foams.

Hilado, C. J.↗

Generation of a parallel X-ray beam and its use for testing collimators

A technique is described, by which a glass strip may be bent to match any curve of large radius of curvature, to a high degree of accuracy, so that it may be used as a glancing incidence X-ray or extreme ultraviolet optical element. The desired match is obtained by applying the optimum combination of end couples and by varying the cross-sectional moment of inertia along the length of the strip. A particular case, that of a parabola for use as a laboratory X-ray collimator, is considered in detail. The analysis predicts that a collimation of one or two arc seconds should be obtainable in practice, with simple and inexpensive apparatus. A prototype collimator to be used for the testing of space payloads using geometric (McGrath) collimators is described and laboratory results presented.

Underwood, J. H.↗