Search NASA⌕ Search

SEARCH · Search NASA

Results for “LAMP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Resonance lamp absorption technique for simultaneous determination of the OH concentration and temperature at 10 spatial positions in combustion environments

A rugged, easy to implement, line-of-sight absorption instrument which utilizes a low pressure water vapor microwave discharge cell as the light source, has been developed to make simultaneous measurements of the OH concentration and temperature at 10 spatial positions. The design, theory, and capability of the instrument are discussed. Results of the measurements obtained on a methane/air flat flame burner are compared with those obtained using a single-frequency, tunable dye laser system.

Shirinzadeh, B.↗

Electric Plasma Arc-Lamp Combustor Liner Durability Test System Developed

Silicon carbide matrix composites are candidate materials for high-temperature combustor liners. Because through-the-thickness thermal gradients are the primary cause of stress on combustor liners, a unique test facility was developed at the NASA Glenn Research Center at Lewis Field to simulate in-service pure thermal stress distributions in fiber reinforced silicon carbide cylinders. It was developed initially under Phase II of the High- Speed Research Program. This test stand can accommodate 8-in.-long test cylinders that have outer diameters of 4 in. and a wall thickness of about 0.08 to 0.12 in. One cylinder at a time is loaded vertically into the test stand. Water-cooled plates enclose the open ends of the cylinder and provide cooling. Load plates on the exterior side of the water-cooled plates provide support and compression loads. To evaluate a combustor liner material s potential performance, researchers induce thermal gradients with an axisymmetric, direct-current, electric arc within the cylinder while refrigerated air at a rate of 1.5 lb/sec impinges on the outside surface of the cylinder. The achievable through-the-thickness thermal gradient is predicted to be in excess of 200 C. The 8-in. long, 0.5-in.-diameter plasma arc emits full spectrum visible light; radiant intensity exceeds 300 Watts per square centimeters to produce temperatures in excess of 1500 C on materials with emissivity near unity. Because the system does not rely upon the combustion of fuels to achieve the related thermal conditions, ancillary environmental reactions with the sample are eliminated. The system incorporates a standard mechanical test frame, which can impose constant as well cyclical axial stresses up to 2200 lb upon the test piece. Silicon-carbide-fiber reinforced silicon carbide matrix composite cylinders were instrumented with thin-film thermocouples to obtain through-the-thickness thermal flux measurements. Inside wall temperatures reached 1200 C with only 250 A of current. One of the special features of this configuration is the creation of hoop stress states within the cylinder, which up this point have not been obtainable in planar coupon tests. This facility will allow various operational modes, including accelerated tests of thermal transients simulating the effects of repeated engine ignition as well as prescribed thermal and mechanical histories to simulate various duty cycle profiles. Tests can now be performed on thermal-barrier-coated metallic liners and ceramic composite liners that require a combination of high heat flux and controlled mechanical stresses.

Goldsby, Jon C.↗

Versatile Controller for Infrared Lamp and Heater Arrays

A paper describes a modular design for new controllers for infrared heating during cruise stage solar thermal vacuum test of the Mars Science Laboratory. The controllers had to be easy to use and maintain, used with a wide variety of different control schemes, and made using commercial off-the-shelf (COTS) components wherever possible.

McKee, Michael R.↗

Xenon lighting adjusted to plant requirements

Xenon lamps are available as low and high power lamps with relatively high efficiency and a relatively long lifetime up to several thousand hours. Different construction types of short-arc and long-arc lamps permit a good adaptation to various applications in projection and illumination techniques without substantial changes of the spectral quality. Hence, the xenon lamp was the best choice for professional technical purposes where high power at simultaneously good spectral quality of the light was required. However, technical development does not stand still. Between the luminous efficacy of xenon lamps of 25-50 lm/W and the theoretical limit for 'white light' of 250 lm/W is still much room for improvement. The present development mainly favors other lamp types, like metal halide lamps and fluorescent lamps for commercial lighting purposes. The enclosed sections deal with some of the properties of xenon lamps relevant to plant illumination; particularly the spectral aspects, the temporal characteristics of the emission, and finally the economy of xenon lamps will be addressed. Due to radiation exceeding the natural global radiation in both the ultraviolet (UV) and the infrared (IR) regions, filter techniques have to be included into the discussion referring to the requirements of plant illumination. Most of the presented results were obtained by investigations in the GSF phytotron or in the closed Phytocell chambers of the University of Erlangen. As our experiences are restricted to area plant illumination rather than spot lights our discussion will concentrate on low pressure long-arc xenon lamps which are commonly used for such plant illuminations. As the spectral properties of short-arc lamps do not differ much from those of long-arc lamps most of our conclusions will be valid for high pressure xenon lamps too. These lamps often serve as light sources for small sun simulators and for monochromators which are used for action spectroscopy of plant responses.

Koefferlein, M.↗

Heat dissipation in controlled environment enclosures through the application of water screens

The use of plate glass-water thermal barriers in controlled environment facilities effectively reduces the thermal load within the plant growth chamber. This allows high PPFs to be provided for plant growth and development studies, adequate simulation of daily light integrals, and simulation of peak PPF's. Further, substantial amounts of incandescent lamp supplementation can be used to achieve simulation of daylight R:FR ratios which are needed to ensure adequate stem development in some species. While the focus in this paper is on the use of entire thermal barriers which separate the lighting enclosure from the plant growth chamber, the same principles apply to the use of water jackets for cooling individual lamps (such as can occur with xenon-arc lamps). In this instance, the barrier separating the lamps from the plant chamber can be much simpler (e.g., plexiglass) as the main function of the barrier is to separate the air ventilation of the lamp enclosure from the air system within the plant growth chamber. The main advantage of water as a thermal barrier is the negligible absorption of radiation in the photosynthetically-active and near infrared wavebands. Consequently, plate glass-water barriers typically allow transmission of approximately 90% of radiation in these regions. While ventilated double and triple glazing systems appear to be attractive alternative to water barriers from an operating standpoint, their significant absorption in the biologically-important wavebands (7 - 12%) with each glass layer and longer-wave cut-offs (typically 2500 - 4000 nm) makes them a much less attractive alternative. The data presented here demonstrate clearly that measurement of PPF alone is not an adequate representation of the radiation environment being used in a controlled environment study. The amounts and proportions of long-wave and short-wave radiation in a plant growth chamber are dependent on lamp type, lamp combination, presence of a thermal barrier, the type of thermal barrier between the lamps and the plant growing area and the overall construction and design of the chamber. It is important, therefore, in reporting results of controlled environment studies, to adequately describe both the details of the lighting system used and the characteristics of the radiation produced by that system, so results of different studies can be adequately evaluated and compared.

Warrington, I. J.↗

Facility and Methods Developed for Simulated Space Vacuum Ultraviolet Exposure Testing of Polymer Films

Vacuum ultraviolet (VUV) radiation of wavelengths between 115 and 200 nm produced by the Sun in the space environment can degrade polymer films, producing changes in their optical, mechanical, and chemical properties. These effects are particularly important for thin polymer films being considered for ultralightweight space structures, because, for most polymers, VUV radiation is absorbed in a thin surface layer. The NASA Glenn Research Center has developed facilities and methods for long-term ground testing of polymer films to evaluate space environmental VUV radiation effects. VUV exposure can also be used as part of combined or sequential simulated space environmental exposures to determine combined damaging effects with other aspects of the space environment, which include solar ultraviolet radiation, solar flare x-rays, electron and proton radiation, atomic oxygen (for low-Earth-orbit missions), and temperature effects. Because the wavelength sensitivity of VUV damage is not well known for most materials, Glenn's VUV facility uses a broad-spectrum deuterium lamp with a magnesium fluoride window that provides output between 115 and 200 nm. Deuterium lamps of this type were characterized by the National Institute of Standards and Technology and through measurements at Glenn. Spectral irradiance measurements show that from approximately 115 to 160 nm, deuterium lamp irradiance can be many times that of air mass zero solar irradiance, and as wavelength increases above approximately 160 nm, deuterium lamp irradiance decreases in comparison to the Sun. The facility is a cryopumped vacuum chamber that achieves a system pressure of approximately 5310(exp -6) torr. It contains four individual VUV-exposure compartments in vacuum, separated by water-cooled copper walls to minimize VUV radiation and any sample contamination cross interactions between compartments. Each VUV-exposure compartment contains a VUV deuterium lamp, a motor-controlled sample stage coupled with a moveable cesium iodide VUV phototube, and two thermocouples for temperature measurement. The vacuum chamber and exterior equipment is shown. Each VUV lamp is located at the top of the chamber with its projection-tube pushed through an O-ring compression fitting. The lamp assemblies are located on ports that can be isolated from the rest of the vacuum chamber, permitting maintenance or replacement of the lamps without breaking vacuum in the main chamber where the samples are located. A view of two of the four interior VUV-exposure compartments, including the moveable sample stages and detector holders is also shown. Glenn is using this facility to support testing of Next Generation Space Telescope sunshield materials that is being led by the NASA Goddard Space Flight Center and to develop an understanding of the wavelength, intensity, and temperature dependence of VUV-induced polymer degradation.

Dever, Joyce A.↗

Orion Cabin Lighting System: Filter Workaround for Maintaining Crew Circadian Entrainment

Introduction: Suboptimal crew circadian entrainment (CCE) is common and results in cumulative fatigue and reduced cognitive function. This may promote use of psychostimulants and hypnotics. The Orion Cabin Lighting System (OCLS) consists of 15 dimmable lamps circuited to several zones. The OCLS monochromatic white lamp design is insufficient for maintaining CCE. While blue light (480-nm) elicits peak wake-cycle response, it is a powerful disruptor of CCE. We propose OCLS lamp filters (OLFs) as a workaround for maintaining CCE. Methods: Preliminary OLFs testing utilized a tunable-white LED to serve as a baseline lamp in the NASA Lighting Lab’s controlled environment (prototype OCLS lamps were unavailable). Illuminance and spectral irradiances were measured with the NASA Lighting Lab’s spectroradiometer. ConOps is proposed for OLFs. Results: OLFs markedly attenuated 480-nm light and illumination with minimal mass/volume requirements. ConOps includes in-flight deployment of OLFs and reducing OCLS lamp intensity prior to bedtime. Pros: minimal mass/volume, no added power, and a simplistic design. Cons: manual twice-daily articulation of OLFs, undetermined frangibility/flammability/off-gassing and effects on thermal regulation, and untested task illumination or color fidelity in the Orion cabin. Discussion: While OLFs aptly attenuate 480-nm light from our tunable LED lamp in the Lighting Lab’s controlled environment, they remain untested within the Orion cabin on OCLS lamps. Future tests include Orion cabin illumination optimization for appropriate Lux delivery and ensuring task/color fidelity with OLFs deployed. Adequate OCLS cooling should be similarly assessed. Other safety testing includes OLF frangibility/flammability/off-gassing in an enriched-O 2 /hypobaric environment. Together, these data will demonstrate OLFs provide a viable workaround for maintaining CCE further ensuring mission safety and success.

Carlos Rene Dostal↗

High intensity portable fluorescent light

Eight high intensity portable fluorescent lights were produced. Three prototype lights were also produced, two of which were subsequently updated to the physical and operational configuration of the qualification and flight units. Positioning of lamp apertures and reflectors in these lights is such that the light is concentrated and intensified in a specific pattern rather than widely diffused. Indium amalgam control of mercury vapor pressure in the lamp gives high output at lamp ambient temperatures up to 105 C. A small amount of amalgam applied to each electrode stem helps to obtain fast warm-up. Shrinking a Teflon sleeve on the tube and potting metal caps on each end of the lamp minimizes dispersion of mercury vapor and glass particles in the event of accidental lamp breakage. Operation at 20 kHz allows the lamps to consume more power than at low frequency, thus increasing their light output and raising their efficiency. When used to expose color photographic film, light from the lamps produces results approximately equal to sunlight.

Kendall, F. B.↗

Spectral Emittance and Reflectance Measurements at the Jet Propulsion Laboratory

In late 1959 a spectrophotometer laboratory was established at JPL to be used as a support for temperature-control programs. The immediate task was spectroradiometric measurements of light sources to be used in a simulated-deep-space environment chamber. It was also necessary to have permanent provisions for measuring reflectances of surfaces for the calculation of solar absorptance alpha, and thermal emittance epsilon. The spectral distribution of an unknown source, in this case a Ventarc carbon-arc lamp, was derived from the ratio of detector outputs (with monochromatic light) of the arc lamp and a tungsten lamp, and the spectral intensity of the tungsten lamp. The tungsten lamp is a ribbonfilament lamp calibrated from 0.25 to 2.6 microns. A recording of pen deflection (linearly proportional to detector output) of each source over the visible and near infrared range is made with all parameters (slit width, amplifier gain, and source focusing) identical; then the ratios are computed at discrete wavelengths from these recordings. Because the spectral intensities of the tungsten lamp and a solar simulator are very different in most of the range, an adjustable slit is placed immediately in front of the detector to obtain comparable pen deflections for the two sources. This slit is set by means of a feeler gage, and the attenuation coefficient is evaluated by a transmission measurement.

Maclay, James E.↗

HOST liner cyclic facilities: Facility description

A quartz lamp box, a quartz lamp annular rig, and a low pressure liner cyclic can rig planned for liner cyclic tests are described. Special test instrumentation includes an IR-TV camera system for measuring liner cold side temperatures, thin film thermocouples for measuring liner hot side temperatures, and laser and high temperature strain gages for obtaining local strain measurements. A plate temperature of 2,000 F was obtained in an initial test of an apparatus with three quartz lamps. Lamp life, however, appeared to be limited for the standard commercial quartz lamps available. The design of vitiated and nonvitiated preheaters required for the quartz lamp annular rig and the cyclic can test rigs is underway.

Schultz, D.↗

Billion shot flashlamp for spaceborne lasers

A billion-shot flashlamp developed under a NASA contract for spaceborne laser missions is presented. Lifetime-limiting mechanisms are identified and addressed. Two energy loadings of 15 and 44 Joules were selected for the initial accelerated life testing. A fluorescence-efficiency test station was used for measuring the useful-light output degradation of the lamps. The design characteristics meeting NASA specifications are outlined. Attention is focused on the physical properties of tungsten-matrix cathodes, the chemistry of dispenser cathodes, and anode degradation. It is reported that out of the total 83 lamps tested in the program, 4 lamps reached a billion shots and one lamp is beyond 1.7 billion shots, while at 44 Joules, 4 lamps went beyond 100 million shots and one lamp reached 500 million shots.

Richter, Linda↗

Sole-Source Lighting for Controlled-Environment Agriculture

Since plants on Earth evolved under broad-spectrum solar radiation, anytime they are grown exclusively under electric lighting that does not contain all wavelengths in similar proportion to those in sunlight, plant appearance and size could be uniquely different. Nevertheless, plants have been grown for decades under fluorescent (FL) (1) + incandescent (IN) (2) lamps as a sole source of lighting (SSL), and researchers have become comfortable that, in certain proportions of FL + IN for a given species, plants can appear "normal" relative to their growth outdoors. The problem with using such traditional SSLs for commercial production typically is short lamp lifespans and not obtaining enough photosynthetically active radiation (PAR, 400-700 nm) when desired. These limitations led to supplementation of FL + IN lamp outputs with longer-lived, high-intensity discharge (HID) lamps in growth chambers (3). As researchers became comfortable that mixes of orange-biased high-pressure sodium (HPS) and blue-biased metal halide (MH) HIDs together also could give normal plant growth at higher intensities, growth chambers and phytotrons subsequently were equipped mainly with HID lamps, with their intense thermal output filtered out by ventilated light caps or thermal-controlled water barriers. For the most part, IN and HID lamps have found a home in commercial protected horticulture, usually for night-break photoperiod lighting (IN) or for seasonal supplemental lighting (mostly HPS) in greenhouses. However, lack of economically viable options for SSL have held back aspects of year-round indoor agriculture from taking off commercially.

Controlled-Environment Agriculture↗

Lander Lighting Solution to Reduce Pilot & Autonomous Approach Errors

The south pole lighting environment will have harsh low inclination sunlight, making overhead judgement of surface features difficult. Autonomous solutions are great, however, the need for visual monitoring and independent go/no-go decisions remain. Our project proposes that lunar landing systems will be better served by including a powerful landing light system that improves visibility of surfaces from overhead by illuminating the ground at critical distances for the crew to make last minute decisions regarding an approach. The project utilized computer-based optical modeling software to predict requirements for a potential landing light system. The analysis based the lamp prediction from commercially available LED chip sets and lamp optics. The goal was to illustrate a method to raise the surface contrast of a landing site within an acceptable contrast threshold for most camera systems and human observers to recognize hazards that would not be noticed with low inclination sunlight alone. The Apollo lunar landings benefitted from overhead sun or dark conditions. The surface lighting at the Lunar South Pole is a harsh environment where surfaces are lit from a low inclination angle by the sun (from the side). This change in lighting condition precipitates a need for updated lunar landing systems that facilitate improved recognition of landing sites, and thereby increase pilot awareness of landing hazards. The reliance on LIDAR and other autonomous mechanisms alone is risky given the known usage of visual monitoring for operator concurrence on current spacecraft programs and present-day autonomous land-based vehicles. Visual monitoring via cameras or windows requires the surface contrast to be within 3 orders of magnitude for reasonable recognition of objects. Artificial overhead illumination, when sufficiently sized, provides a means to even out contrast problems created by low inclination sunlight, potentially reducing piloting errors. Current vehicle requirements do not specify this type of guidance for the purpose of increasing mission success. An optical ray-trace simulation model was developed in Zemax Optics Studio to predict the best combination of LED power, LED optics, lamp quantity, and lamp location to raise the surface contrast to within 2 orders of magnitude from 3 orders required to further increased visibility and reduce risk. The project considered the following design constraints: potential base diameter of lander, approach distance(s) for a go-no-go decision point (200 meter), solar inclination angle (2-7), lunar surface reflectance (10%), LED chip sets, LED focusing optics, LED power, lamp quantity, lamp locations, and illumination diameter of lunar surface landing zone. The results can be used to establish minimum design constraints for vehicle landing light systems. With a solar inclination angle ranging from 2-7 degrees, the horizontal illumination of the lunar surface is attenuated by about 10% when compared to overhead illumination from the Sun. This modifies the sun's maximum of 130,000 lux to 13,000 lux horizontal illuminance. The artificial lighting system was designed to provide an 18-meter-wide illumination zone, to create viewing clearances around a 6-meter-wide lander. The system provides an average illuminance of 300 lux, meeting the 2 orders of magnitude criteria. The solution utilized modern Chip On Board LEDs, that each utilized 17 watts, with focusing Total Internal Reflection (TIR) lenses. A lighting system of 300 LEDs was arrayed along the "bottom" of a “lander”. With 17 watts per LED, the system is estimated to require 5100 watts. This is a large amount of power, but it would only be needed during critical phases during the landing. LED lighting systems can be dimmed, and it is assumed that as the lander arrives closer to the landing site, the lighting system power can be adjusted as needed to produce the necessary surface illuminance. The designed reduction of contrast improves reliability of safety assessments using real time visible light camera systems and out the window viewing by the crew.

T A Clark↗

Heads up display

A heads up aircraft display which allows the pilot to view the display without diverting his attention from the scene ahead is disclosed. The display is designed for use on propeller driven aircraft comprised of a radially disposed row of lamps embedded in the rear surface of a propeller. Measurements of flight data are made by conventional means and converted into digital signals. These digital signals are applied to graphic generators which control lamp drivers which in turn control lamps through slip rings. The lamps are lit at the appropriate times during each revolution of the propeller to display the flight data in graphic form to the pilot. The combination of graphic generators and radially disposed lamps embedded in an aircraft propeller enables the pilot to view the display without diverting his attention from the scene ahead.

Garner, H. D.↗

Investigation of light source and scattering medium related to vapor-screen flow visualization in a supersonic wind tunnel

Methods for increasing the radiant in light sheets used for vapor screen set-ups were investigated. Both high-pressure mercury arc lamps and lasers were considered. Pulsed operation of the air-cooled 1-kW lamps increased the light output but decreased reliability. An ellipsoidal mirror improved the output of the air-cooled lamps by concentrating the light but increased the complexity of the housing. Water-cooled-4-kW lamps coupled with high-aperture Fresnel lenses provided reasonable improvements over the air-cooled lamps. Fanned laser beams measurements of scattered light versus dew point made in conjunction with successful attempts to control the fluid injection. A number of smoke generators are described and test results comparing smoke and vapor screens are shown. Finally, one test included a periscope system to relay the image to a camera outside the flow.

Snow, W. L.↗

HOST liner cyclic facilities

The HOST Liner Cyclic Program is utilizing two types of test apparatus, rectangular box rigs and a full annular rig. To date two quartz lamp cyclic box rigs have been tested and a third is to begin testing in late October 1983. The box rigs are used to evaluate 5x8 inch rectangular linear samples. A 21 inch diameter outer liner simulator is also being built up for testing beginning in April 1984. All rigs are atmospheric rigs. The first box rig, a three 6-kVA lamp installation, was operated under adverse conditions to determine feasibility of using quartz lamps for cyclic testing. This work was done in December 1981 and looked promising. The second box rig, again using three 6-kVA lamps, was operated to obtain instrumentation durability information and initial data input to a Finite Element Model. This limited test program was conducted in August 1983. Five test plates were run. Instrumentation consisted of strain gages, thermocouples and thermal paint. The strain gages were found to fail at 1200 F as expected though plates were heated to 1700 F. The third box rig, containing four 6-kVA lamps, is in build up for testing to begin in late October 1983. In addition to 33 percent greater power input, this rig has provision for 400 F backside line cooling air and a viewing port suitable for IR camera viewing. The casing is also water cooled for extended durability.

Schultz, D.↗