Search NASA⌕ Search

SEARCH · Search NASA

Results for “LIGHT PIPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Flow-Assisted Corrosion in Nuclear Power Plants

The flow-assisted corrosion, or flow-accelerated corrosion (FAC) is one of the major piping degradation mechanisms in aging nuclear power plants and it has been identified as a research area under the Light Water Reactor Sustainability program at Idaho National Laboratory (INL). While every nuclear power plant in US has a dedicated flow-assisted corrosion management program, there are several areas where the management of flow assisted corrosion can be improved. One of such areas is on-line corrosion monitoring which can significantly reduce maintenance inspections and contribute to improvement of economic efficiency of nuclear power plants. The proliferation of low cost sensor modalities such as strain fiber optics sensors and noninvasive concentration sensors, allowed development of on-line nonintrusive monitoring techniques, which can complement or replace existing evaluation techniques. The report presents a literature review of the current state-of-the-art in flow-assisted corrosion monitoring, and a research framework to study on-line monitoring techniques. The report addresses the problem on on-line monitoring of flow-assisted corrosion in nuclear power plants.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary studies on diversion and misuse for TRISO-fueled heat-pipe-cooled microreactors

Microreactors are being developed by multiple reactor designers to mass-produce nuclear facilities for worldwide deployment. Including microreactors in a country’s energy portfolio introduces new concerns for international safeguards regarding the number of reactor locations. Microreactors have smaller quantities of nuclear material compared to current light-water reactors, which makes diverting enough material for clandestine purposes difficult for a single reactor. Diversion or misuse of multiple microreactors to obtain a significant quantity introduces a new acquisition pathway. This work examines diversion and misuse scenarios for a realistic heat-pipe-cooled microreactor to understand how these scenarios would effect reactor operations to determine if monitoring key parameters could reduce the burden of inspection on monitoring agencies. Here, we determined misuse caused too drastic of an effect on core operations to be a valid acquisition pathway for the realistic heat-pipe-cooled microreactor. Diversion was explored across varying levels of severity, where potential diversion scenarios could yield one significant quantity of material from between six and eleven microreactors. Through examining the critical control drum angle, excess reactivity, control drum worth, and power distribution changes from nominal were detected over the operational lifetime, which could indicate a divergence from normal operations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluation of CNT Energy Savers Retrofit Packages Implemented in Multifamily Buildings

This evaluation explored the feasibility of designing prescriptive retrofit measure packages for typical Chicago region multifamily buildings in order to achieve 25%-30% source energy savings through the study of three case studies. There is an urgent need to scale up energy efficiency retrofitting of Chicago's multifamily buildings in order to address rising energy costs and a rapidly depletingrental stock. Aimed at retrofit program administrators and building science professionals, this research project investigates the possibility of using prescriptive retrofit packages as a time- and resource-effective approach to the process of retrofitting multifamily buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Beam Diagnostic by Outside Beam Chamber Fields

Fields induced by a beam and penetrated outside the beam pipe can be used for a beam diagnostic. Wires placed in longitudinal slots in the outside wall of the beam pipe can work as a beam pickup. This has very small beam-coupling impedance and avoids complications of having a feed-through. The signal can be reasonably high at low frequencies. We calculate the beam-coupling impedance due to a long longitudinal slot in the resistive wall and the signal induced in a wire placed in such a slot and shielded by a thin screen from the beam. We present a field waveform at the outer side of a beam pipe, obtained as a result of calculations and measurements. Such kind of diagnostic can be used in storage rings, synchrotron light sources, and free electron lasers, like LINAC coherent light source.

43 PARTICLE ACCELERATORS↗

New μ forces from ν μ sources

Accelerator-based experiments reliant on charged pion and kaon decays to produce muon-neutrino beams also deliver an associated powerful flux of muons. Therefore, these experiments can additionally be sensitive to light new particles that preferentially couple to muons and decay to visible final states on macroscopic length scales. Such particles are produced through rare 3-body meson decays in the decay pipe or via muon scattering in the beam dump, and decay in a downstream detector. To demonstrate the potential of this search strategy, we recast existing MiniBooNE and MicroBooNE studies of neutral pion production in neutrino-induced neutral-current scattering ( ν μ N → ν μ N π 0 , π 0 → γ γ ) to place limits on light ( < 2 m μ ) muon-philic scalar particles that decay to diphotons through loops of virtual muons. While much of this parameter space has already been excluded by E137, we also project that SBND can be sensitive to unexplored parameter space for these models, and provide a road map for future neutrino experiments to perform dedicated searches for muon-philic forces. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Determination of the Convective Heat-Exchange Coefficient in Inner Channels of Light-Absorbing Heat-Exchange Panels of Flat-Plate Solar Water-Heating Collectors Based on the Results of Their Short-Term Thermal Testing in Full-Scale Conditions

The results of investigations to determine the convective heat-exchange coefficient in the inner heat-exchange channels (HECs) of the light-absorbing heat-exchange panels (LAHPs) of flat-plate solar water-heating collectors (FPSWHCs) are given based on the results of their short-term heat testing in fullscale quasi-stationary conditions. The research method is based on determining the value of the required parameter from the heat-balance equation formed for the inner surfaces of the LAHP HEC walls. The structures of the flow LAHPs with a sheet-piped and thin parallelepiped form are selected as the test objects. The thermal tests of the FPSWHC are carried out during the near-midday hours of the light day to ensure the quasi-stationary mode condition. The reliability of the proposed method and results of the investigations is proved by comparing the values of the thermal-efficiency coefficients of the FPSWHC LAHPs obtained using two independent approaches.

14 SOLAR ENERGY↗

Advanced radiator concepts

Two radiator systems to reject heat from future space nuclear power systems were conceptually designed. One design would dissipate 1.7 MWt of heat at 600 K, and the other would reject 2.4 MWt at 875 K. The low-temperature radiator utilized a pumped loop system constructed of titanium, and achieved a specific mass of 5.8 kg/sq m, including pumps and structure. The high-temperature radiator system utilized potassium heat pipes constructed of SiC-reinforced titanium, and achieved a specific mass of 5.5 kg/sq m. Both radiators took advantage of light, high-thermal-conductivity carbon/graphite composite fins to distribute and radiate the rejected heat.

Begg, L. L.↗

Method for transporting impellent gases

The described system DAL comprises a method and a device for transportation of buoyant impellent gases, without the need for expensive pipes and liquid tankers. The gas is self air-lifted from its source to a consignment point by means of voluminous, light, hollow bodies. Upon release of the gas at the consignment point, the bodies are filled with another cheap buoyant gas (steam or heated air) for the return trip to the source. In both directions substantial quantities of supplementary freight goods can be transported. Requirements and advantages are presented.

Papst, H.↗

Mirascope Luminescent Beam Profile Monitor

Advanced beam diagnostics are essential for reliable operation of high-performance accelerators and the intense beams produced by them. Non-invasive diagnostics can be used continuously with intense beams, while invasive techniques interfere with the beams and distort the beam profiles. In addition, traditional solid-based beam monitoring instrumentation produces unacceptable levels of radiation operating in high power beam environments. Noninvasive determination of accelerated particle distributions and profiles is the most difficult task of bunch diagnostics. Muons, Inc. proposed to develop non-interfering residual-gas beam profile monitors for transfer lines with pulse-to-pulse precision of better than 0.1 mm in position and size that will operate over a wide range of proton beam intensities including those needed for multi-MW beams of future facilities. The approach was to develop a low mass residual-gas profile monitor, where beam induced fluorescence (BIF) will be used to monitor the beam profile. An original scheme of light collection using a mirascope, an optical device invented in the 16th century, is proposed. The gas composition and pressure in the beam pipe are locally controlled to minimize unwanted radiation and to improve resolution.

43 PARTICLE ACCELERATORS↗

ISOTHERMAL AIR INGRESS VALIDATION EXPERIMENTS AT IDAHO NATIONAL LABORATORY: DESCRIPTION AND SUMMARY OF DATA

Idaho National Laboratory performed air ingress experiments as part of validating computational fluid dynamics code (CFD). An isothermal stratified flow experiment was designed and set to understand stratified flow phenomena in the very high temperature gas cooled reactor (VHTR) and to provide experimental data for validating computer codes. The isothermal experiment focused on three flow characteristics unique in the VHTR air-ingress accident: stratified flow in the horizontal pipe, stratified flow expansion at the pipe and vessel junction, and stratified flow around supporting structures. Brine and sucrose were used as heavy fluids and water was used as light fluids. The density ratios were changed between 0.87 and 0.98. This experiment clearly showed that a stratified flow between heavy and light fluids is generated even for very small density differences. The code was validated by conducting blind CFD simulations and comparing the results to the experimental data. A grid sensitivity study was also performed based on the Richardson extrapolation and the grid convergence index method for modeling confidence. As a result, the calculated current speed showed very good agreement with the experimental data, indicating that the current CFD methods are suitable for predicting density gradient stratified flow phenomena in the air-ingress accident.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MELCOR Accident Progression and Source Term Demonstration Calculations for a Heat Pipe Reactor

MELCOR is an integrated thermal hydraulics, accident progression, and source term code for reactor safety analysis that has been developed at Sandia National Laboratories for the United States Nuclear Regulatory Commission (NRC) since the early 1980s. Though MELCOR originated as a light water reactor (LWR) code, development and modernization efforts have expanded its application scope to includ e non-LWR reactor concepts. Current MELCOR development efforts include providing the NRC with the analytical capabilities to support regulatory readiness for licensing non-LWR techno logies under Strategy 2 of the NRC?s near- term Implementation Action Plans. Beginning with the Next Generation Nuclear Project (NGNP), MELCOR has undergone a range of enha ncements to provide analytical capabilities for modeling the spectrum of advanced non-LWR concepts. This report describes the generic plant model developed to demonstrate MELCOR capabilities to perform heat pipe reactor (HPR) safety evaluations. The generic plant mode l is based on a publicly-available Los Alamos National Laboratory (LANL) Megapower design as modified in the Idaho National Laboratory (INL) Design A description. For plant aspects (e.g., reactor building size and leak rate) that are not described in the LANL and INL references , the analysts made assumptions needed to construct a MELCOR full-plant model. The HP R uses high assay, low-enrichment uranium (HALEU) fuel with steel cladding that uses heat pipes to transfer heat to a secondary Brayton air cycle. The core region is surrounded by a stainless-steel shroud, alumina reflector, core barrel and boron carbide neutron shield. The reactor is secured inside a below-grade cavity, with the operating floor located above the cavity. Example calculations are performed to show the plant response and MELCOR capabilities to characterize a range of accident conditions. The accidents selected for evaluation consider a range of degraded and failed modes of operation for key safety functions providing re activity control, the primary and secondary system heat removal, and the effectiveness of th e confinement natural circulation flow into the reactor cavity (i.e., a flow blockage).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The use of holographic interferometry for measurements of temperature in a rectangular heat pipe

Holographic interferometry is a nonintrusive method and as such possesses considerable advantages such as not disturbing the velocity and temperature field by creating obstacles which would alter the flow field. These optical methods have disadvantages as well. Holography, as one of the interferometry methods, retains the accuracy of older methods, and at the same time eliminates the system error of participating components. The holographic interferometry consists of comparing the objective beam with the reference beam and observing the difference in lengths of optical paths, which can be observed during the propagation of the light through a medium with locally varying refractive index. Thus, change in refractive index can be observed as a family of nonintersecting surfaces in space (wave fronts). The object of the investigation was a rectangular heat pipe. The goal was to measure temperatures in the heat pipe, which yields data for computer code or model assessment. The results were obtained by calculating the temperatures by means of finite fringes.

Marn, Jure↗

Additive Manufacturing and Working Fluid Characterization of Ceramic Heat Pipes

In this work, additively manufactured (AM) aluminum nitride (AlN) ceramic heat pipes were developed to improve spacecraft heat rejection capabilities beyond the current state-of-the-art metal systems. A low sintering temperature aluminum nitride slurry is developed for digital light processing printing (DLP) and the optimal debinding curves are examined. Printed AlN parts are characterized via SEM and optical profilometry. AlN 3D-printed parts are also tested for compatibility with aluminum bromide, aluminum chloride, and iodine, among other proposed working fluids at 350-600 K in an inert atmosphere, with reactivity measured via SEM and Fourier transform infrared spectroscopy (FTIR).

Thermal Management↗

Working Fluid Trade Study for a Two-Phase Mechanically Pumped Loop Thermal Control System

NASA Jet Propulsion Laboratory is investigating a two-phase mechanically pumped fluid loop (MPFL) technology for spacecraft thermal control for future planetary space science mission concepts. The two-phase technology combines the potential of single-phase MPFL and the passive two-phase heat pipe systems. Previous two-phase MPFL studies at JPL have identified an evaporator system with a separated flow architecture as providing a robust light mass thermal control system with very high spatial and temporal thermal stability required by the science instruments on these missions. These studies have further identified the thermophysical properties of the working fluid to be key to the performance of a two-phase fluid loop. This paper describes the methodology used in the selection of the working fluids for optimizing the performance of the two-phase MPFL. A high level model was developed that includes the constraints and boundaries driven by the system components. The performance of fluids from the REFPROP database are investigated and rated for this system. The working fluid attributes such as cost, hazardous properties, and heritage were taken into account in this selection. A typical spacecraft dissipating 1000 W and a fluid loop consisting of an evaporator, accumulator, radiator, and associated tubing components is used as an example in this study.

Daimaru, Takuro↗

Study of solid molecular deuterium D 2 growth under gas pressure

The injection of high-speed cryogenic pellets made of frozen hydrogen-isotopes, represents to date the most effective method to fuel magnetically confined thermonuclear fusion plasmas. Additionally, the injection of very large pellets composed of cryogenic solid of some suitable impurity (typically a noble-gas such as H 2 , Ne, or H 2 /Ne, D 2 /Ne mixtures), shattered in relatively small fragments just before entering the plasma, seems to be the most promising method to reduce the damage risks for the plasma-facing components in case of a plasma disruption. This technology, known as "Shattered Pellet Injection" (SPI), allows to spread out the plasma energy and mitigate possible damage to the in-vessel components, as well as to densify the plasma to suppress the formation of runaway electrons, and/or dissipate their energy. Several techniques to produce and launch cryogenic pellets have been investigated in the past decades. "Pipe gun" injectors are reliable and relatively simple devices are still commonly used today. They make use of single- or two-stage pneumatic light-gas guns to accelerate the pellet at high speeds. In these injectors, the cryogenic pellets are formed “ in situ ” (i.e., inside the launching barrel), by de-sublimating them directly from the gas phase, i.e., at temperatures and pressures below those of the triple point. The simplest case is pure deuterium pellets ($\mathcal{T}$ < 18.7 K, $\mathcal{P}$ < 171.3 hPa). The production of good quality solid deuterium, capable of withstanding the mechanical stress during the acceleration of the pellets, is a key issue. To this end the phase transition of deuterium from gas to solid (and vice versa) is modeled with extensive molecular-dynamics (MD) simulations. Furthermore, the solid growth from the gas phase is simulated in an ample range of temperatures and pressures, to find the best compromise between growth velocity and mechanical properties of the resulting solid system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Working Fluid Trade Study for a Two-Phase Mechanically Pumped Loop Thermal Control System

NASA Jet Propulsion Laboratory is investigating a two-phase mechanically pumped fluid loop (MPFL) technology for spacecraft thermal control for future planetary space science mission concepts. The two-phase technology combines the potential of single-phase MPFL and the passive two-phase heat pipe systems. Previous two-phase MPFL studies4,5 at JPL have identified an evaporator system with a separated flow architecture as providing a robust light mass thermal control system with very high spatial and temporal thermal stability required by the science instruments on these missions. These studies have further identified the thermophysical properties of the working fluid to be key to the performance of a two-phase fluid loop. This paper describes the methodology used in the selection of the working fluids for optimizing the performance of the two-phase MPFL. A high level model was developed that includes the constraints and boundaries driven by the system components. The performance of fluids from the REFPROP database were investigated and rated for this system. The working fluid attributes such as cost, hazardous properties, and heritage were taken into account in this selection. A typical spacecraft dissipating 1000 W and a fluid loop consisting of an evaporator, accumulator, radiator, and associated tubing components was used as an example in this study.

Daimaru, Takuro↗

Acoustic Emission and Guided Ultrasonic Waves for Detection and Continuous Monitoring of Cracks in Light Water Reactor Components

Acoustic emission (AE) and guided ultrasonic waves (GUW) are considered for continuous monitoring and detection of cracks in Light Water Reactor (LWR) components. In this effort, both techniques are applied to the detection and monitoring of fatigue crack growth in a full scale pipe component. AE results indicated crack initiation and rapid growth in the pipe, and significant GUW responses were observed in response to the growth of the fatigue crack. After initiation, the crack growth was detectable with AE for approximately 20,000 cycles. Signals associated with initiation and rapid growth where distinguished based on total rate of activity and differences observed in the centroid frequency of hits. An intermediate stage between initiation and rapid growth was associated with significant energy emissions, though few hits. GUW exhibit a nearly monotonic trend with crack length with an exception of measurements obtained at 41 mm and 46 mm.

Acoustic Emission↗