Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals

Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.

Akerib, DS↗

Climate Impact on CO2 Capture Efficiency and Levelized Cost of Liquid solvent-based DAC (Direct Air Capture) System

The transition towards net-zero emission poses economic, technical, and political challenges for the commercial-scale deployment of CO2 removal technologies by 2050. The opportunities for large-scale deployment will largely depend on the distinctive conditions found in the different locations of the world such as energy cost, carbon intensity of energy source, construction, transportation, and weather conditions. In this work, we focus on one of the promising negative emission technology, DAC (Direct Air Capture), and its response to different weather conditions. This work presents two potential operation scenarios: (i) natural gas standalone, (ii) grid electricity connected DAC plant. For the first time, we investigated the influence of temperature and RH (relative humidity) of the air on liquid-based DAC system and its response to carbon capture efficiency and levelized cost of carbon capture with operational sensitivity analysis. It is observed that the overall energy demand decreases from 11.1 to 8.3 GJ/ton-CO2 as the CO2 capture rate increases from 40 to 85%. We observed that a CO2 capture rate of 75% is only possible above 17°C even at 90% RH and this drops tremendously at lower temperatures. It is also observed that water evaporation in the air contactor is highest at dry and low RH as expected. The sensitivity analysis showed that weather conditions are insensitive to CO2 capture efficiency for the liquid-solvent based DAC plant for both scenarios. In addition, higher CO2 capture efficiency is achievable from lower upstream methane emissions and carbon intensity of grid electricity (for grid-connected scenario). Lastly, the levelized cost of natural gas standalone scenario varies from 239.7 to 408.8 $/t-CO2 is sensitive to temperature conditions more than relative humidity and compared to electricity grid-connected scenario, from 265.3 to 440.1 $/t-CO2.

An, Keju↗

Effect of water droplet growth dynamics on electrode current in fuel-cell catalyst layers

Fuel cells are a promising next-generation energy-conversion technology designed to replace internal combustion engines in transportation applications. However, much work remains to optimize them. Operation at high humidities causes liquid water droplet formation on Pt catalyst particles during oxygen reduction, potentially impeding reactant arrival to the reactive electrode. In this work, four different cases of water droplet growth in fuel-cell catalyst layers are considered: pinned or advancing droplets on a bare Pt surface, advancing droplets on a Nafion film, and water-layer growth in carbon nanopores. Transient drop growth is captured with a combination of mass, species mass, and momentum balances, and the subsequent limiting current is determined via oxygen diffusion and Tafel kinetics. Further, water droplets are found not to be mass-transfer limiting due to the relatively large liquid-gas area compared to the Pt nanoparticle. Mass-transfer-limited behavior is calculated in carbon nanopores.

25 ENERGY STORAGE↗

Fixed-target serial femtosecond crystallography using in cellulo grown microcrystals

The crystallization of recombinant proteins in living cells is an exciting new approach in structural biology. Recent success has highlighted the need for fast and efficient diffraction data collection, optimally directly exposing intact crystal-containing cells to the X-ray beam, thus protecting the in cellulo crystals from environmental challenges. Serial femtosecond crystallography (SFX) at free-electron lasers (XFELs) allows the collection of detectable diffraction even from tiny protein crystals, but requires very fast sample exchange to utilize each XFEL pulse. Here, an efficient approach is presented for high-resolution structure elucidation using serial femtosecond in cellulo diffraction of micometre-sized crystals of the protein HEX-1 from the fungus Neurospora crassa on a fixed target. Employing the fast and highly accurate Roadrunner II translation-stage system allowed efficient raster scanning of the pores of micro-patterned, single-crystalline silicon chips loaded with living, crystal-containing insect cells. Compared with liquid-jet and LCP injection systems, the increased hit rates of up to 30% and reduced background scattering enabled elucidation of the HEX-1 structure. Using diffraction data from only a single chip collected within 12 min at the Linac Coherent Light Source, a 1.8 Å resolution structure was obtained with significantly reduced sample consumption compared with previous SFX experiments using liquid-jet injection. This HEX-1 structure is almost superimposable with that previously determined using synchrotron radiation from single HEX-1 crystals grown by sitting-drop vapour diffusion, validating the approach. This study demonstrates that fixed-target SFX using micro-patterned silicon chips is ideally suited for efficient in cellulo diffraction data collection using living, crystal-containing cells, and offers huge potential for the straightforward structure elucidation of proteins that form intracellular crystals at both XFELs and synchrotron sources.

Lahey-Rudolph, J. Mia (ORCID:0000000152797267)↗

Gapped magnetic ground state in quantum spin liquid candidate {kappa}-(BEDT-TTF){sub 2}Cu{sub 2}(CN){sub 3}.

Geometrical frustration, quantum entanglement, and disorder may prevent long-range ordering of localized spins with strong exchange interactions, resulting in an exotic state of matter. kappa-(BEDT-TTF)(2)Cu-2(CN)(3) is considered the prime candidate for this elusive quantum spin liquid state, but its ground-state properties remain puzzling. We present a multifrequency electron spin resonance (ESR) study down to millikelvin temperatures, revealing a rapid drop of the spin susceptibility at 6 kelvin. This opening of a spin gap, accompanied by structural modifications, is consistent with the formation of a valence bond solid ground state. We identify an impurity contribution to the ESR response that becomes dominant when the intrinsic spins form singlets. Probing the electrons directly manifests the pivotal role of defects for the low-energy properties of quantum spin systems without magnetic order.

Miksch, Bjorn↗

The impact of climate on solvent-based direct air capture systems

Direct air capture (DAC) is increasingly seen as a critical technology to reach mid-century net-zero targets and limit climate change to well below 2 °C. While the commercialization of DAC technologies is being pursued by numerous companies, there remains remarkably little information on their performance under “real-world” conditions. In this paper, for the first time, we investigate the influence of temperature and relative humidity of air on the CO 2 capture rate at the air contactor, overall energy requirement, CO 2 capture efficiency, and levelized cost of liquid-solvent based DAC systems. We observe that the overall energy demand decreases from 11.1 to 8.3 GJ/tCO 2 as the CO 2 capture rate increases from 40 to 85 % and that high capture rates can only be achieved in hot and humid climate conditions. We observe that a CO 2 capture rate of 75 % is only possible above 17 °C and 90 % relative humidity, and this drops dramatically at lower temperatures. It is also observed that water evaporation in the air contactor is highest at dry and low relative humidity, as expected. The sensitivity analysis showed that CO 2 capture efficiency is relatively insensitive to climate conditions for the liquid-solvent based DAC plant. Lastly, the levelized cost of natural gas standalone scenario varies from $240/tCO 2 to $409/tCO 2 , and this is more sensitive to temperature than relative humidity. The levelized cost of the natural gas stand-alone case is between 7 % and 10 % lower than that of an electric grid-connected case across all climate conditions.

54 ENVIRONMENTAL SCIENCES↗

Insight into pseudo-film-boiling in supercritical water under simplified interfacial conditions

The focus of this paper is the physics of supercritical water film boiling through the simulation of natural convection of supercritical water in a rectangular cavity. It has been widely believed that above a fluid's critical point, only one phase exists. However, recent research has indicated the existence of distinct gas-like and liquid-like regions separated by the Widom line, which is the locus of the maxima of the specific heat. Along the Widom line, density decreases sixfold, viscosity drops by a factor of two, while specific heat spikes by an order of magnitude. These variations, specifically in density and viscosity, produce a thick pseudo-interface and flow dynamics behavior akin to film-boiling, denoted here as pseudo-two-phase flow dynamics. When the cavity is heated from the bottom, a pseudo-film of gas-like fluid is formed at the heated wall, and the flow complexity evolves, characterized by the formation of multiple vortices. Results demonstrate the ability of modern conjugate heat transfer computational fluid dynamics to capture the pseudo two-phase regime, with the formation of a pseudo-film at the heated wall. Further, the boiling curve is studied, showing an increase in heat flux with an increase in the temperature differential between the wall and the pseudo-critical temperature. Furthermore, results also show a previously uncharacterized instability, where the convection cells in the cavity oscillate and can flip directions under certain conditions.

Computational fluid dynamics↗

Drop Size Distribution Variability in Central Argentina during RELAMPAGO-CACTI

The Remote sensing of Electrification, Lightning, And Meso-scale/micro-scale Processes with Adaptive Ground Observations (RELAMPAGO) and the Cloud, Aerosol, and Complex Terrain Interactions Experiment Proposal (CACTI) field campaigns provided an unprecedented thirteen-disdrometer dataset in Central Argentina during the Intensive (IOP, 15 November to 15 December 2018) and Extended (EOP, 15 October 2018 to 30 April 2019) Observational Periods. The drop size distribution (DSD) parameters and their variability were analyzed across the region of interest, which was divided into three subregions characterized by the differing proximity to the Sierras de Córdoba (SDC), in order to assess the impact of complex terrain on the DSD parameters. A rigorous quality control of the data was first performed. The frequency distributions of DSD-derived parameters were analyzed, including the normalized intercept parameter (logN w ), the mean volume diameter (D 0 ), the mean mass diameter (D m ), the shape parameter (μ), the liquid water content (LWC), and the rain rate (R). The region closest to the SDC presented higher values of logN w , lower D 0 , and higher μ, while the opposite occurred in the farthest region, i.e., the concentration of small drops decreased while the concentration of bigger drops increased with the distance to the east of the SDC. Furthermore, the region closest to the SDC showed a bimodal distribution of D 0 : the lower values of D 0 were associated with higher values of logN w and were found more frequently during the afternoon, while the higher D 0 were associated with lower logN w and occurred more frequently during the night. The data were analyzed in comparison to the statistical analysis of Dolan et al. 2018 and sorted according to the classification proposed in the cited study. The logN w -D 0 and LWC-D 0 two-dimensional distributions allowed further discussion around the applicability of other mid-latitude and global precipitation classification schemes (startiform/convection) in the region of interest. Finally, three precipitation case studies were analyzed with supporting polarimetric radar data in order to relate the DSD characteristics to the precipitation type and the microphysical processes involved in each case.

54 ENVIRONMENTAL SCIENCES↗

Recovery of Alkaline-Earths into Liquid Bi in Ternary LiCl-KCl-SrCl 2 /BaCl 2 Electrolytes at 500 °C

Electrochemical reduction of Sr 2+ and Ba 2+ into liquid Bi was investigated in dilute concentrations of SrCl 2 /BaCl 2 (0-5 mol%) in LiCl-KCl electrolytes at 500 °C to ascertain the limit of liquid Bi electrodes for alkaline-earth recovery. Analysis of the electrodes after constant current electrolysis to the specific charge of 270 C g -1 showed Sr 2+ ions consuming 29% of charge at 5 mol% before dropping to 8%-10% of the total charge at 0.45-0.72 mol% SrCl 2 . Ba 2+ ions consumed 54% at 5 mol% BaCl 2 before decreasing to 22%-24% at 0.42-0.89 mol% BaCl 2 ; substantial co-deposition of Li was observed in all chemistries, consuming up to 53% of charge. Considering only 1% of the total charge was consumed for depositing Ba 2+ and Sr 2+ ions in ~0.1 mol% SrCl 2 /BaCl 2 electrolyte, the lower recovery limit of Bi for alkaline-earth elements is suggested to be at ~0.4 mol% SrCl 2 /BaCl 2 to achieve appreciable deposition of alkaline-earths (>1.5 mol% Ba/Sr in liquid Bi). The overpotentials of liquid Bi at 5 mol% of SrCl 2 /BaCl 2 were evaluated by electrochemical impedance spectroscopy. The co-deposition of Sr and Li exhibited the largest increase in charge transfer resistances implying sluggish charge transfer kinetics whereas the co-deposition of Ba and Li exhibited a large increase in mass transport resistances due to the slow diffusion of Ba 2+ ions in the electrolyte.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Glycolate Analysis in Tank 22: Developing and Testing Analytical Methods for the Savannah River Site Liquid Waste System

Researchers developed and tested a range of techniques to support a low mg/L Limit of Quantitation (LOQ) of glycolate in radioactive Tank 22 waste solution by Ion Chromatography (IC) and by proton NMR. For the IC method, Dionex OnGuard II cartridges were tested as a means of removing alkali earth and transition metals that can interfere during ion chromatography applications especially when analyzing for low-concentration, chelating analytes. Additionally, concentrations of nitrate in the raw Tank 22 sample (5,000 to 10,000 mg/L) were managed by using reasonable levels of sample dilution. The resulting IC performance quality was enhanced by improving the baseline, increasing sensitivity [Limit of Quantitation (LOQ) of 12 mg/L and Limit of Detection (LOD) of 4.0 mg/L], and resolving analytes into well-defined Gaussian peaks when using the Dionex OnGuard II H⁺ cartridges to remove matrix interferences. High concentrations of nitrate limited the performance of the IC method. To achieve an acceptable baseline, samples with high nitrate content require more dilution, resulting in higher detection limits. Tests on samples with higher concentrations of nitrate (Tank 30 and 32 supernate with approximately 150000 mg/L nitrate) suggested that IC detection limits for glycolate in these samples would be > 500 mg/L. Thus, an LOQ of 12 mg/L is not feasible by this IC method on evaporator feed samples. An alternative method of glycolate analysis, using proton nuclear magnetic resonance (H NMR), was developed by the research team. In initial tests, the H NMR technique provided reasonable quantitation of glycolate in Tank 22 conditions by direct observation of the liquid. The H NMR method may provide improved detection limits for solutions with higher nitrate concentrations. We recommend further development of this analysis for high nitrate LWS samples such as evaporator feed and evaporator drop tank content. A method for pretreatment of samples using crystalline silicotitanate (CST) was developed and tested. The objective of the pretreatment was to facilitate analysis of samples with higher levels of radioactivity. The pretreatment did not influence the glycolate concentration in solution, and the pretreatment is projected to reduce Cs 137 activity in a sample by a factor of 16,200. The double strike CST pretreatment was demonstrated and would allow milliliters of higher activity samples to be transferred from the Shielded Cells and handled in a containment unit for glycolate analysis. The various studies validated IC and H NMR methods for glycolate analysis, defined the range of applicability, and demonstrated key supporting analytical protocols. Based on the results, high quality glycolate analysis of Tank 22 is feasible down to approximately 12 mg/L, with the potential for broader applicability of the methods to other conditions in the Savannah River Site Liquid Waste System (LWS).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Control of the Plasma-Material Interface for Long Pulse Optimization in EAST Final Report

This final report describes the funded activity to understand and control the plasma-material interface to improve long pulse discharge control and performance on the EAST (Experimental Advanced Superconducting Tokamak) facility, located in Hefei, China. The primary focus of the research was long pulse recycling control via optimization of lithium (Li) delivery systems, including flowing liquid lithium plasma facing components (PFCs), because Li persists as the main wall conditioning technique. On EAST, lithium was primarily introduced using crucible evaporation, pellet injection, and gravitationally dropped powder. Overall, the introduction of lithium into the EAST plasma had strong and persistent effects on the ELM behavior during long pulse EAST discharges demonstrating overall improved performance. Additionally, a flexible impurity injection tool, a multi-chamber impurity powder dropper, was developed and deployed on EAST, to extend powder injection to elements other than Li. Finally, improvements to the Soft X-ray diagnostic system were introduced to improve measurements of impurity transport and electron temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

CFD Simulations of Molten Salts Within Plasma-Facing Components with Twisted Tape Inserts Under One-Sided–Heated Conditions

For liquid immersion blankets (LIBs), the heat removal within different plasma-facing components (PFCs) requires substantial heat removal capabilities that could benefit from the usage of heat transfer enhancements. Of consideration are twisted tape insert heat transfer enhancements that are ribbon-like metal pieces inserted within cooling channels that increase fluid mixing, resulting in higher heat transfer and pressure drop. Unlike traditional applications, PFCs such as divertor coolant tubes experience a significantly higher heat flux on one side versus the other or entirely one-sided heating. These conditions are not well studied for molten salts where the higher Prandtl numbers characteristic of the fluids are significantly higher than water, gases, and liquid metals. As an effort to study this knowledge gap, large eddy simulations were done with Prandtl numbers representative of FLiBe at proposed operating conditions. In this study, the effects of applying a surface heat flux to one side of a tube versus the entire tube with a twisted tape insert were investigated for the heat transfer coefficient and effects on the temperature profile. The findings of the study suggest that for Prandtl number fluids above unity, the Nusselt number was largely unaffected by the change in boundary condition. Both boundary conditions showed good agreement with the Manglik and Bergles Nusselt number correlation for tight-fitting twisted tapes. Finally, the outcomes of this study will be useful for future design studies of LIBs to provide fundamental guidance implementing twisted tape inserts and their performance in one-sided–heated conditions.

molten salts↗

Vertical Structure and Ice Production Processes of Shallow Convective Postfrontal Clouds over the Southern Ocean in MARCUS. Part I: Observational Study

A study of the vertical structure of postfrontal shallow clouds in the marine boundary layer over the Southern Ocean is presented here. The central question of this two-part study regards cloud phase (liquid/ice) of precipitation, and the associated growth mechanisms. In this first part, data from the Measurements of Aerosols, Radiation, and Clouds over the Southern Ocean (MARCUS) field campaign are analyzed, starting with a 75-h case with continuous sea surface-based thermal instability, modest surface heat fluxes, an open-cellular mesoscale organization, and very few ice nucleating particles (INPs). The clouds are mostly precipitating and shallow (tops mostly around 2 km above sea level), with weak up- and downdrafts, and with cloud-top temperatures generally around –18° to –10°C. Further, the case study is extended to three other periods of postfrontal shallow clouds in MARCUS. While abundant supercooled liquid water is commonly present, an experimental cloud-phase algorithm classifies nearly two-thirds of clouds in the 0° to –5°C layer as containing ice (cloud ice, snow, or mixed phase), implying that much of the precipitation grows through cold-cloud processes. The best predictors of ice presence are cloud-top temperature, cloud depth, and INP concentration. Measures of convective activity and turbulence are found to be poor indicators of ice presence in the studied environment. The water-phase distribution in this cloud regime is explored through numerical simulations in Part II. Significance Statement: Climate models generally predict a lower albedo than observed over the Southern Ocean, and this is largely attributed to a lack of cloudiness, especially in the postfrontal cold sector of midlatitude cyclones. This in turn may be due to an excess of ice in these simulated clouds, resulting in rapid precipitation fallout and an overly brief cloud lifespan. The objective of this study is to examine whether shallow postfrontal clouds over the Southern Ocean are dominated by supercooled drops, or by snow and ice, using data collected by a U.S. Department of Energy Atmospheric Radiation Measurement Mobile Facility deployed aboard an Australian Antarctic supply vessel. We find that these clouds contain much supercooled liquid, even though cloud-top temperatures generally are around –18° to –8°C, and that about two-thirds of the clouds just above the freezing level contain ice. Much of the precipitation appears to grow through cold-cloud processes above the freezing level, rather than drizzle/rain. Updrafts and/or turbulence in convection or in cloud-top generating cells do not initiate much ice, compared to observations elsewhere in a similar temperature range. This may be attributable to the extremely low concentration of ice nucleating particles in this environment. Ultimately, the deepest clouds with the coldest cloud tops are most likely to be ice dominated.

54 ENVIRONMENTAL SCIENCES↗

Metal additively manufactured wavy fin cold-plate architecture for improved thermal-hydraulic performance

Rapid growth in artificial intelligence and data center workloads demands high-performance liquid cooling to manage increasing chip power. This study presents two metal-additive-manufactured cold plates with sinusoidal fins, constant-amplitude wavy fins and linearly variable-amplitude wavy fins and compares them against metal-additive-manufactured straight fins using experiments conducted at 1 kW heat dissipation as well as high-fidelity 3D conjugate computational fluid dynamic simulations. The cold plates were printed in AlSi10Mg material and underwent design using a Python-automated workflow prior to manufacture and testing. The experiments show that wavy fins reduce the normalized thermal resistance by 35 to 45 % at water flow rates from 1 to 4 LPM. At a fixed 20 kPa pressure drop, the variable-waviness design lowered peak surface temperature by 9 °C and thermal resistance by 51 %, while edge-channel maldistribution in the constant wavy fin design limited gains. A thermal resistance breakdown revealed that 55–63 % of the total thermal resistance in wavy designs comes from base heat conduction, 27–33 % from fin heat conduction, and 9–13 % from fin heat convection, indicating the need to address conduction bottlenecks. Parametric sweeps identify a 3 mm fin pitch as optimal, and that horizontal inlet/outlet manifolds further reduce pressure drop by 30–60 % and thermal resistance by 9–16 % relative to vertical inlet-outlet manifolds. The results yield comprehensive guidelines for fin geometry, manifold alignment, material selection and additive-manufacturing constraints to realize high-performance liquid-cooled cold plates for power-dense electronics.

3d printing↗

CROCUS Forward Scatter Disdrometer Data at Argonne National Laboratory Prairie Site

The Vaisala FD70 is a multi-parameter present weather and visibility sensor designed to measure precipitation type, intensity, and visibility with high accuracy in diverse environmental conditions. It uses a combination of forward-scatter measurement and optical disdrometer technologies to detect drop size, fall speeds, and optical properties, enabling the classification of various precipitation types such as rain, snow, sleet, and freezing rain along is visibility estimates. The FD70 provides quantitative estimates of liquid-equivalent precipitation rate and meteorological optical range (MOR), supporting applications in meteorological research, aviation, and road weather monitoring. These measurements are collected at the Argonne Testbed for Multiscale Observational Science (ATMOS), a 20 acre prairie site at Argonne National Lab, located in Lemont, IL. Data is available in netcdf format. Each file contains one second interval data, for approximately 24 hrs each day. File naming convention includes the project (CROCUS), location (ATMOS), instrument name, data level (raw, a1), and date (year, month, day).

54 ENVIRONMENTAL SCIENCES↗

Study on Emulsification/Demulsification Behavior and Mechanism of Produced Liquid from Polymer Flooding on Alaska North Slope

Heavy oil reservoirs on Alaska North Slope (ANS) are unconsolidated and contain abundant clay minerals, where the first-ever field pilot is currently implemented to validate the use of polymer floods for heavy oil enhanced oil recovery (EOR). The polymer molecules and/or fine clay particles carried with the produced liquid could potentially affect the oil/water separation, which is one of the major concerns for field operators. This dissertation aims to investigate the emulsification behavior of produced liquid, understand the emulsifying mechanism, and seek an adaptive and cost-effective method to treat the produced liquid from polymer flooding. Emulsions were prepared by mechanically mixing the actual heavy oil and the produced water from the pilot site, of which the stability was investigated by bottle test method or multiple light scattering method. Drop size distribution and interfacial properties were measured via microscope and pendant drop technique to probe the stability mechanism further. Results showed that oil-continuous or water-continuous emulsion could be generated depending on the water cut, clay types, clay concentration, and polymer concentration. In the crude oil/water system, the increasing water cut triggered the phase inversion of oil-continuous emulsion to water-continuous emulsion, resulting in faster separation and lower emulsion stability. Whereas, clay particles, no matter added to the oil or water phase, resulted in an unfavorable phase inversion from the loose water-continuous emulsion to the tight oil-continuous emulsion as clay concentration increased. For all four types of clay except Ca-montmorillonite, clay particles added to water led to an earlier phase inversion and higher emulsion stability than that added to the oil. The dual function of polymer on emulsion stability was observed. On the one hand, both sheared and unsheared polymer tended to convert the oil-continuous emulsion formed in either crude oil/water system or complex crude oil/water/clay particle system to the water-continuous emulsion, acting as a weak demulsifier to accelerate the oil/water separation. On the other hand, the addition of polymer to the water-continuous emulsion could result in enhanced emulsion stability, which is primarily attributed to the increased viscosity of the continuous phase and the decreased drop size of the dispersed oil phase. Particularly, the sheared polymer had a weaker ability to stabilize the o/w emulsion than the unsheared polymer due to the lower viscosity of the sheared polymer solution resulting from the breakdown of the polymer macromolecules. As for the chemical demulsification tests, the performance of demulsifiers showed a complex dependency upon the water cut, the shearing intensity, demulsifier type and dosage, and the polymer concentration. A compound emulsion breaker, E12+E18, exhibited the most satisfactory demulsification performance despite the varied test conditions. For severe water-continuous emulsions that might require a multi-fold dosage of demulsifier, a less expensive electrolyte, KCl, was proposed to be used in combination with demulsifier E12+E18 to improve the demulsification performance. In the proposed demulsifier formula, the effectiveness of the commercial demulsifier relied on its destructive effect on the interfacial film, while the efficacy of KCl was mainly dependent on its viscosity reduction effect on the continuous phase. This dissertation illustrates that intermediate layer elimination and water clarification are the major challenges for produced liquid treatment from polymer flooding. It also provides practical and theoretical guidance in advance for the demulsification strategy of the produced liquid from the ongoing first-ever polymer flooding pilot on ANS.

Chang, Hongli↗

Local convection characteristics of inline arrangement of Kagome-shaped unit cells in a square duct

Transient liquid crystal thermography experiments have been conducted to determine detailed convective heat transfer coefficients at the endwalls of lattice-frame configurations based on Kagome-shaped unit cells. Kagome unit cells with porosity of 0.88 were arranged in an inline manner, where two such arrangements were studied. In the first arrangement, a total of ten unit cells were placed next to each other along the streamwise direction resulting in a continuous configuration. In the 2nd arrangement, alternate unit cells from the continuous configuration were dropped, resulting in a discrete configuration which featured a total of 5 Kagome unit cells. Due to the asymmetric nature of the strut connections within the unit cell, the convective heat transfer coefficient maps were determined for the two opposite walls where the struts meet the endwalls. Transient liquid crystal experiments were conducted for Reynolds number ranging between 10,000 and 30,000. Here, the study was focused on the developing nature of flow along the streamwise direction and the local convection characteristics for continuous and discrete arrangement of unit cells. For the continuous configuration, the Nusselt number ratios (N u /Nu 0 ) varied between 3.15–3.46 and 2.75–2.89 for the two walls A and B, respectively. For the discrete configuration, convective heat transfer coefficients varied between 2.56–2.71 and 2.09–2.40 for the two walls. Kagome unit cells have the potential to be fabricated through inexpensive manufacturing routes such as wire-woven method and these unit cells find their applications in the areas which require different heat transfer levels on opposite walls.

Kagome↗

High-temperature high-pressure microfluidic system for rapid screening of supercritical CO 2 foaming agents

CO 2 foam helps to increase the viscosity of CO 2 flood fluid and thus improve the process efficiency of the anthropogenic greenhouse gas’s subsurface utilization and sequestration. Successful CO 2 foam formation mandates the development of high-performance chemicals at close to reservoir conditions, which in turn requires extensive laboratory tests and evaluations. This work demonstrates the utilization of a microfluidic reservoir analogue for rapid evaluation and screening of commercial surfactants (i.e., Cocamidopropyl Hydroxysultaine, Lauramidopropyl Betaine, Tallow Amine Ethoxylate, N,N,N' Trimethyl-N'-Tallow-1,3-diaminopropane, and Sodium Alpha Olefin Sulfonate) based on their performance to produce supercritical CO 2 foam at high salinity, temperature, and pressure conditions. The microfluidic analogue was designed to represent the pore sizes of the geologic reservoir rock and to operate at 100 °C and 13.8 MPa. Values of the pressure drop across the microfluidic analogue during flow of the CO 2 foam through its pore network was used to evaluate the strength of the generated foam and utilized only milliliters of liquid. The transparent microfluidic pore network allows in-situ quantitative visualization of CO 2 foam to calculate its half-life under static conditions while observing if there is any damage to the pore network due to precipitation and blockage. The microfluidic mobility reduction results agree with those of foam loop rheometer measurements, however, the microfluidic approach provided more accurate foam stability data to differentiate the foaming agent as compared with conventional balk testing. The results obtained here supports the utility of microfluidic systems for rapid screening of chemicals for carbon sequestration or enhanced oil recovery operations.