Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser Calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Laser Pyrometer For Spot Temperature Measurements

Laser pyrometer makes temperature map by scanning measuring spot across target. Scanning laser pyrometer passively measures radiation emitted by scanned spot on target and calibrated by similar passive measurement on blackbody of known temperature. Laser beam turned on for active measurements of reflectances of target spot and reflectance standard. From measurements, temperature of target spot inferred. Pyrometer useful for non-contact measurement of temperature distributions in processing of materials.

Elleman, D. D.↗

Laser Energy Monitor for Triple-Pulse 2-μm IPDA Lidar Application

Integrated path differential absorption (IPDA) lidar is an active remote sensing technique for monitoring different atmospheric species. The technique relies on wavelength differentiation between strong and weak absorbing features normalized to the transmitted energy. An advanced 2-μm triple-pulse IPDA lidar was developed at NASA Langley Research Center for active sensing of carbon dioxide and water vapor simultaneously. The IPDA transmitter produces three successive laser pulses separated by a short interval (200 μs) with a repetition rate of 50Hz. Measurement of laser pulse energy accurately is a prerequisite for the retrieval of gas mixing ratios from IPDA. The design and calibration of a 2-μm triple-pulse laser energy monitor are presented. Due to the short interval between the three transmitted pulses, conventional thermal energy monitors underestimate the total transmitted energy. The design is based on a high speed, extended range InGaAs pin quantum detector suitable for separating the three pulse events. Pulse integration is applied for converting the detected pulse power into energy. The results obtained from the laser energy monitor were compared to an ultra-fast energy-meter reference for energy scaling and verification. High correlations between the pin energy monitor and the total transmitted energy were obtained. The objective of this development is to reduce measurement biases and errors using the triple-pulse IPDA technique.

Refaat, Tamer F.↗

Performance Analysis of Airborne Photon-Counting Lidar Data in Preparation for the ICESat-2 Mission

Two airborne photon-counting laser altimeters have been deployed in direct support of National Aeronautics and Space Adminsitration (NASA's) upcoming Ice, Cloud, and land Elevation Satellite-2 (ICESat-2) mission. Multiple Altimeter Beam Experimental Lidar (MABEL) was developed specifically for ICESat-2 testing and development. MABEL data are used to simulate key aspects of the ICESat-2 measurement strategy and are critical to the development of the algorithms for geophysical data-product generation. Slope Imaging Multipolarization Photon-counting Lidar (SIMPL) is a NASA Goddard Space Flight Center instrument that has also been deployed in support of ICESat-2 performance discovery. Both instruments are photon-counting, small footprint laser altimeters that sample in both the 532- and 1064-nm wavelengths. And both instruments serve as a proxy for ICESat-2 operational performance and error assessment and a basis for the development of potential validation strategies. This paper provides an overview of how data from MABEL and SIMPL overflights have specifically provided the foundation for understanding the quality of ICESat-2 data and how we can plan to evaluate ICESat-2 products through comparison with other modalities of lidar data and/or groundtruth locations using ground fiducials.

MABEL↗

Detector Based Calibration of a Portable Imaging Spectrometer for CLARREO Pathfinder Mission

The Climate Absolute Refractivity and Reflectance Observatory (CLARREO) Pathfinder (CPF) mission is being developed to demonstrate SI-traceable retrievals of reflectance at unprecedented accuracies for global satellite observations. An Independent Calibration of the CPF sensor using the Goddard Laser for Absolute Measurement of Radiance (GLAMR) is planned to allow validation of CPF accuracies. GLAMR is a detector-based calibration system relies on a set of NIST-calibrated transfer radiometers to assess the spectral radiance from the GLAMR sphere source to better than 0.3 % (k=2). The current work describes the calibration of the Solar, Lunar Absolute Reflectance Imaging Spectroradiometer (SOLARIS) that was originally developed as a calibration demonstration system for the CLARREO mission and is now being used to assess the independent calibration being developed for CPF. The methodology for the radiometric calibration of SOLARIS is presented as well as results from the GLAMR-based calibration of SOLARIS. The portability of SOLARIS makes it capable of collecting field measurements of earth scenes and direct solar and lunar irradiance similar to those expected during the on-orbit operation of the CPF sensor. Results of SOLARIS field measurements are presented. The use of SOLARIS in this effort also allows the testing protocols for GLAMR to be improved and the field measurements by SOLARIS build confidence in the error budget for GLAMR calibrations. Results are compared to accepted solar irradiance models to demonstrate accuracy values giving confidence in the error budget for the CLARREO reflectance retrieval.

Aytac, Yigit↗

Laser Energy Monitor for Double-Pulsed 2-Micrometer IPDA Lidar Application

Integrated path differential absorption (IPDA) lidar is a remote sensing technique for monitoring different atmospheric species. The technique relies on wavelength differentiation between strong and weak absorbing features normalized to the transmitted energy. 2-micron double-pulsed IPDA lidar is best suited for atmospheric carbon dioxide measurements. In such case, the transmitter produces two successive laser pulses separated by short interval (200 microseconds), with low repetition rate (10Hz). Conventional laser energy monitors, based on thermal detectors, are suitable for low repetition rate single pulse lasers. Due to the short pulse interval in double-pulsed lasers, thermal energy monitors underestimate the total transmitted energy. This leads to measurement biases and errors in double-pulsed IPDA technique. The design and calibration of a 2-micron double-pulse laser energy monitor is presented. The design is based on a high-speed, extended range InGaAs pin quantum detectors suitable for separating the two pulse events. Pulse integration is applied for converting the detected pulse power into energy. Results are compared to a photo-electro-magnetic (PEM) detector for impulse response verification. Calibration included comparing the three detection technologies in single-pulsed mode, then comparing the pin and PEM detectors in double-pulsed mode. Energy monitor linearity will be addressed.

Refaat, Tamer F.↗

Sub-nanosecond ranging possibilities of optical radar at various signal levels and transmitted pulse widths

The behavior of the photomultiplier is considered, as well as the method of derivation of the photomultiplier output pulse and its relation to the reflected light pulse width and amplitude, and the calibration of range precision and accuracy. Pulsed laser radars with light pulse widths of 30, 3, and 0.1 nanosec a considered, with the 0.1 nanosec system capable of highest precision in several modes of operation, including a high repetition rate, single photoelectron reception mode. An alternate calibration scheme using a fast, triggerable light pulser is described in detail.

Poultney, S. K.↗

Equipment for On-Wafer Testing From 220 to 325 GHz

A system of electronic instrumentation, constituting the equivalent of a two-port vector network analyzer, has been developed for use in on-wafer measurement of key electrical characteristics of semiconductor devices at frequencies from 220 to 325 GHz. A prior system designed according to similar principles was reported in Equipment for On-Wafer Testing at Frequencies Up to 220 GHz (NPO-20760), NASA Tech Briefs, Vol. 25, No. 11 (November 2001), page 42. As one would expect, a major source of difficulty in progressing to the present higher-frequency-range system was the need for greater mechanical precision as wavelengths shorten into the millimeter range, approaching the scale of mechanical tolerances of prior systems. The system (see figure) includes both commercial off-the-shelf and custom equipment. As in the system of the cited prior article, the equipment includes test sets that are extended versions of commercial network analyzers that function in a lower frequency range. The extension to the higher frequency range is accomplished by use of custom frequency-extension modules that contain frequency multipliers and harmonic mixers. On-wafer measurement is made possible by waveguide wafer probes that were custom designed and built for this wavelength range, plus an on-wafer calibration substrate designed for use with these probes. In this case, the calibration substrate was specially fabricated by laser milling. The system was used to make the first on-wafer measurements of a semiconductor device in the frequency range from 220 to 320 GHz. Some of the measurement results showed that the device had gain.

Samoska, Lorene↗

A Simulation Study of Multi-Beam Altimetry for Lunar Reconnaissance Orbiter and Other Planetary Missions

The combined use of altimetry, Earth-based Doppler and Earth-based range measurements in the lunar reconnaissance orbiter (LRO) mission (Chin et al. in Space Sci Rev 129:391-419, 2007) has been examined in a simulation study. It is found that in the initial phases of the mission orbit and altimeter geolocation accuracies should be better than 10m in the radial component and 60m overall. It is demonstrated that LRO's precise 1-way laser range measurement from Earth-based stations (Smith et al. in Proceedings of the 15th International Laser Ranging Workshop, Canberra, Australia, October 15-20, 2006) will be useful for gravity recovery. The advantages of multiple laser beams are demonstrated for altimeter calibration, orbit determination and gravity recovery in general planetary settings as well as for LRO.

Rowlands, D. D.↗

Lidar Systems - Where We Are

A general review of the past ten years of LIDAR system development will be presented. Equipment problems and many of their solutions are discussed. These include problems with photomultipliers, lasers, interference filters, data acquisition, etc. Calibration and alignment techniques are also presented. Instrumentation for multi-wavelength, Raman, doppler, monostatic and bistatic techniques being used by various researchers are described. New developments and a gaze into the future are included.

McCormick, M. P.↗

Five-Channel Infrared Laser Absorption Spectrometer for Combustion Product Monitoring Aboard Manned Spacecraft

Continuous combustion product monitoring aboard manned spacecraft can prevent chronic exposure to hazardous compounds and also provides early detection of combustion events. As future missions extend beyond low-Earth orbit, analysis of returned environmental samples becomes impractical and safety monitoring should be performed in situ. Here, we describe initial designs of a five-channel tunable laser absorption spectrometer to continuously monitor combustion products with the goal of minimal maintenance and calibration over long-duration missions. The instrument incorporates dedicated laser channels to simultaneously target strong mid-infrared absorption lines of CO, HCl, HCN, HF, and CO2. The availability of low-power-consumption semiconductor lasers operating in the 2 to 5 micron wavelength range affords the flexibility to select absorption lines for each gas with maximum interaction strength and minimal interference from other gases, which enables the design of a compact and mechanically robust spectrometer with low-level sensitivity. In this paper, we focus primarily on absorption line selection based on the availability of low-power single-mode semiconductor laser sources designed specifically for the target wavelength range.

Briggs, Ryan M.↗

Data Reduction Procedures for Laser Velocimeter Measurements in Turbomachinery Rotors

Blade-to-blade velocity distributions based on laser velocimeter data acquired in compressor or fan rotors are increasingly used as benchmark data for the verification and calibration of turbomachinery computational fluid dynamics (CFD) codes. Using laser Doppler velocimeter (LDV) data for this purpose, however, must be done cautiously. Aside from the still not fully resolved issue of the seed particle response in complex flowfields, there is an important inherent difference between CFD predictions and LDV blade-to-blade velocity distributions. CFD codes calculate velocity fields for an idealized rotor passage. LDV data, on the other hand, stem from the actual geometry of all blade channels in a rotor. The geometry often varies from channel to channel as a result of manufacturing tolerances, assembly tolerances, and incurred operational damage or changes in the rotor individual blades.

Lepicovsky, Jan↗

Technology for active laser remote sensing from space

The requirements for the experiments to be performed on the laser atmospheric sounder and altimeter facility of the polar orbiting platform are considered. The proposed instruments for the Lidar In-Space Technology Experiment designed to calibrate and verify the radiative transfer equation for laser energies at wavelengths of 1060, 532, and 355 nm, and to measure the vertical distribution of aerosols, the optical thickness of high altitude clouds, and the top of clouds are described. Research in the area of tunable laser materials and Lidar transmitters, in particular Ti:Al2O3 materials and Lidar transmitters, aimed at increasing wavelength tunability, efficiency, and the lifetime of solid-state lasers for utilization on Space Station polar orbiting platforms is discussed.

Sokoloski, M. M.↗

Airborne simultaneous spectroscopic detection of laser-induced water Raman backscatter and fluorescence from chlorophyll a and other naturally occurring pigments

The airborne laser-induced spectral emission bands obtained simultaneously from water Raman backscatter and the fluorescence of chlorophyll and other naturally occurring waterborne pigments are reported here for the first time. The importance of this type data lies not only in its single-shot multispectral character but also in the application of the Raman line for correction or calibration of the spatial variation of the laser penetration depth without the need for in situ water attenuation measurements. The entire laser-induced fluorescence and Raman scatter emissions resulting from each separate 532-nm 10-nsec laser pulse are collected and spectrally dispersed in a diffraction grating spectrometer having forty photomultiplier tube detectors. Results from field experiments conducted in the North Sea and the Chesapeake Bay/Potomac River are presented. Difficulties involving the multispectral resolution of the induced emissions are addressed, and feasible solutions are suggested together with new instrument configurations and future research directions.

Hoge, F. E.↗

Theory of CW lidar aerosol backscatter measurements and development of a 2.1 microns solid-state pulsed laser radar for aerosol backscatter profiling

The performance and calibration of a focused, continuous wave, coherent detection CO2 lidar operated for the measurement of atmospheric backscatter coefficient, B(m), was examined. This instrument functions by transmitting infrared (10 micron) light into the atmosphere and collecting the light which is scattered in the rearward direction. Two distinct modes of operation were considered. In volume mode, the scattered light energy from many aerosols is detected simultaneously, whereas in the single particle mode (SPM), the scattered light energy from a single aerosol is detected. The analysis considered possible sources of error for each of these two cases, and also considered the conditions where each technique would have superior performance. The analysis showed that, within reasonable assumptions, the value of B(m) could be accurately measured by either the VM or the SPM method. The understanding of the theory developed during the analysis was also applied to a pulsed CO2 lidar. Preliminary results of field testing of a solid state 2 micron lidar using a CW oscillator is included.

Kavaya, Michael J.↗

Cryogenic absolute radiometers as laboratory irradiance standards, remote sensing detectors, and pyroheliometers

The dramatic improvement in heat diffusivity of pure Cu at liquid-He temperatures makes possible very important advances in the absolute accuracy, reproducibility, sensitivity, and time constant of cryogenic electrical substitution radiometers (ESRs), relative to conventional ESRs. The design and characterization of a table-top cryogenic ESR now available for detector calibration work to the 0.01-percent level of absolute accuracy under laser illumination is discussed. A sensitive cryogenic ESR recently delivered to the NIST for radiometric calibrations of black bodies is also described, along with the design and testing of a very fast cryogenic ESR developed for NASA remote-sensing studies of the earth's radiation budget.

Foukal, Peter V.↗

Vertical Roughness of the Polar Regions of Mars from Mars Orbiter Laser Altimeter Pulse-Width Measurements

The sub-kilometer scale vertical roughness of the martian surface in the polar regions can be investigated using calibrated, optical pulse width data provided by the Mars Orbiter Laser Altimeter (MOLA). Garvin and others have previously discussed initial observations of what we have called "total vertical roughness" or TVR, as derived from MOLA optical pulse width observations acquired during the pre-mapping phases of the Mars Global Surveyor (MGS) mission. Here we present the first assessment of the Mars polar region properties of the TVR parameter from more than nine months of continuous mapping by MOLA as part of the MGS mapping mission. Other than meter-scale surface properties directly inferred from Mars Orbiter Camera (MOC) images, MOLA measurements of footprint-scale TVR represent the only direct measurements of the local vertical structure of the martian surface at approx. 150 m length scales. These types of data have previously been shown to correlate with geologic process histories for terrestrial desert surfaces on the basis of Shuttle Laser Altimeter (SLA) observations. Additional information is obtained in the original extended abstract.

Garvin, J. B.↗