Assessment of errors in analytic modeling of permanent magnet electron spectrometers for laser-plasma accelerators

Here, we assess the error in three treatments of a critical electron beam diagnostic for laser-plasma acceleration (LPA) experiments: a permanent magnet electron spectrometer. Since LPA electron spectrometers are often difficult to calibrate due to the scarcity of well-characterized, tunable electron beam sources in the appropriate energy range and the mechanical complexity of electron spectrometers, the standard of calibration is Hall probe measurements. We first compare the electron spectrometer performance between SIMION calculations and the Hall probe measurements. We find up to a 60% (<8%) error in determining the absolute energy for electrons below (above) 80 MeV when using the SIMION-modeled magnetic field vs the measured magnetic field due to SIMION overpredicting fringe field strength. The difference in spectrometer energy resolution is within ∼10% between the modeled and measured fields. We then assess a simple block model, which is commonly used. We find that the simple block model presented here sufficiently captures the predicted as-built spectrometer performance for any application provided that the user can tolerate uncertainties on absolute energy determination up to 5% and errors on energy resolution up to 1%.

Electromagnetic optics↗

Role of hot electrons in shock ignition constrained by experiment at the National Ignition Facility

Shock ignition is a scheme for direct drive inertial confinement fusion that offers the potential for high gain with the current generation of laser facility; however, the benefits are thought to be dependent on the use of low adiabat implosions without laser–plasma instabilities reducing drive and generating hot electrons. A National Ignition Facility direct drive solid target experiment was used to calibrate a 3D Monte Carlo hot-electron model for 2D radiation-hydrodynamic simulations of a shock ignition implosion. The α = 2.5 adiabat implosion was calculated to suffer a 35% peak areal density decrease when the hot electron population with temperature T ℎ = 55 keV and energy E ℎ = 13 kJ was added to the simulation. Optimizing the pulse shape can recover ~1/3 of the peak areal density lost due to a change in shock timing. Here, despite the harmful impact of laser–plasma instabilities, the simulations indicate shock ignition as a viable method to improve performance and broaden the design space of near ignition high adiabat implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LDRD for a high-current polarized-beam photogun

The electron accelerator driving the Ce+BAF conversion target requires a spin-polarized photogun capable of delivering a CW beam current of at least 1 mA. As the high beam current limits the useful operating time of the gun between photocathode reactivations due to ion back-bombardment, it is critical to increase the charge lifetime. A Jefferson Lab LDRD project aims to calibrate the simulation models needed to predict photocathode lifetime as a function of electrostatic optics and drive laser parameters in order to design a gun providing at least 1000 C charge lifetime. A prototype gun demonstrating the validity of the scaling predictions will be built and tested at the Gun Test Stand. I will describe the background and progress of this project and give an outlook on the expected performance.

Bruker, Max [Thomas Jefferson National Accelerator↗

Hydrogen isotope analysis in W-tiles using fs-LIBS

Abstract Laser-Induced Breakdown Spectroscopy (LIBS) is a promising technology for in-situ analysis of Plasma-Facing Components in magnetic confinement fusion facilities. It is of major interest to monitor the hydrogen isotope retention i.e. tritium and deuterium over many operation hours to guarantee safety and availability of the future reactor. In our studies we use ultraviolet femtosecond laser pulses to analyze tungsten (W) tiles that were exposed to a deuterium plasma in the linear plasma device PSI-2, which mimics conditions at the first wall. A high-resolution spectrometer is used to detect the Balmer- $$\alpha$$ α transition of the surface from implanted hydrogen isotopes (H and D). We use Calibration Free CF-LIBS to quantify the amount of deuterium stored in W. This proof-of-principle study shows the applicability of femtosecond lasers for the detection of low deuterium concentration as present in first wall material of prevailing fusion experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A long path-length optical property measurement device for highly transparent detector media

Measurements of the optical properties of highly transparent liquids are necessary for large-scale detectors that seek to detect optical signatures in kiloton-scale or larger volumes. Detailed understanding of the attenuation and scattering properties of fill media is critical to the ability to accurately simulate detector performance, and yet is often unavailable until in-situ measurements can be performed. Moreover, in-situ measurements may rely on effective attenuation lengths or other approximations to characterize performance, rather than absolute measurements of attenuation and scattering. To better understand the optical properties of potential fill media and purification schemes, a system has been developed which provides simultaneous attenuation and differential scattering cross-section measurements for highly transparent liquids. This horizontal, adjustable path-length “long-arm” system provides excellent isolation from the atmosphere, a high degree of vibration insensitivity, and a simple and reliable method of calibration. Further, scattering measurements can be carried out simultaneously at ports along the beamline equipped with optics allowing the selection of scatter angle and polarization. This enables both reliable quantitative scatter measurements and phase-function separation. This system has been extensively tested using deionized (DI) water as a benchmark, and has demonstrated repeatable measurements of attenuation lengths exceeding 100 m and scattering lengths approaching 1 km.

47 OTHER INSTRUMENTATION↗

Calibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL

In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.

47 OTHER INSTRUMENTATION↗

Self-calibration strategies for reducing systematic slope measurement errors of autocollimators in deflectometric profilometry

Deflectometric profilometers are used to precisely measure the form of beam shaping optics of synchrotrons and X-ray free-electron lasers. They often utilize autocollimators which measure slope by evaluating the displacement of a reticle image on a detector. Based on our privileged access to the raw image data of an autocollimator, novel strategies to reduce the systematic measurement errors by using a set of overlapping images of the reticle obtained at different positions on the detector are discussed. It is demonstrated that imaging properties such as, for example, geometrical distortions and vignetting, can be extracted from this redundant set of images without recourse to external calibration facilities. This approach is based on the fact that the properties of the reticle itself do not change – all changes in the reticle image are due to the imaging process. Firstly, by combining interpolation and correlation, it is possible to determine the shift of a reticle image relative to a reference image with minimal error propagation. Secondly, the intensity of the reticle image is analysed as a function of its position on the CCD and a vignetting correction is calculated. Thirdly, the size of the reticle image is analysed as a function of its position and an imaging distortion correction is derived. It is demonstrated that, for different measurement ranges and aperture diameters of the autocollimator, reductions in the systematic errors of up to a factor of four to five can be achieved without recourse to external measurements.

47 OTHER INSTRUMENTATION↗

A critical look at the prediction of the temperature field around a laser-induced melt pool on metallic substrates

The study of microstructure evolution in additive manufacturing of metals would be aided by knowing the thermal history. Since temperature measurements beneath the surface are difficult, estimates are obtained from computational thermo-mechanical models calibrated against traces left in the sample revealed after etching, such as the trace of the melt pool boundary. Here we examine the question of how reliable thermal histories computed from a model that reproduces the melt pool trace are. To this end, we perform experiments in which one of two different laser beams moves with constant velocity and power over a substrate of 17-4PH SS or Ti-6Al-4V, with low enough power to avoid generating a keyhole. We find that thermal histories appear to be reliably computed provided that (a) the power density distribution of the laser beam over the substrate is well characterized, and (b) convective heat transport effects are accounted for. Poor control of the laser beam leads to potentially multiple three-dimensional melt pool shapes compatible with the melt pool trace, and therefore to multiple potential thermal histories. Ignoring convective effects leads to results that are inconsistent with experiments, even for the mild melt pools here.

42 ENGINEERING↗

Dynamic computational optical fringe mitigation in tunable laser absorption spectroscopy

In optical spectroscopic systems where unwanted optical scattering cannot be eliminated, Fabry-Pérot etalons cause unpredictable changes in the spectral background. Frequent system calibration is then required to maintain the desired measurement accuracy, which presents a major limitation to the spectrometer. We introduce a computational approach to mitigate the adverse effects of optical fringing without hardware modifications. Motivated by experimental observations of complicated fringe behaviors, we simplify the problem by decomposing the fringe background into component etalons that can be addressed according to their individual characteristics. The effectiveness of the proposed method is demonstrated on a silicon photonic methane sensor, where accurate measurements of methane concentration are obtained from spectral data strongly affected by optical fringes.

Teng, Chu C. (ORCID:0000000152744835)↗

Pixel response characterization of the ARCADIA fully depleted MAPS

Monolithic Active Pixel Sensors (MAPS) achieved widespread use in several scientific applications, thanks to their properties, such as low material budget and high granularity. The ARCADIA INFN project developed a Fully-Depleted MAPS (FD-MAPS), using a modified LFoundry 110 nm CIS process. This work presents the first laboratory characterization of the ARCADIA MD3 prototype. Measurements include threshold uniformity studies using both test-pulse injection and a 55 Fe source, as well as threshold and noise calibration achieved thanks to monochromatic X-ray sources. Ultimately, charge-collection efficiency is evaluated using an infrared laser setup.

Particle tracking detectors↗

The Role of Quantum Science Concepts in Enhancing Sensing and Imaging Technologies: Applications for Biology: Proceedings of a Workshop

Quantum concepts hold the potential to enable significant advances in sensing and imaging technologies that could be vital to the study of biological systems. The workshop Quantum Science Concepts in Enhancing Sensing and Imaging Technologies: Applications for Biology, held online March 8–10, 2021, was organized to examine the research and development needs to advance biological applications of quantum technology. Hosted by the National Academies of Sciences, Engineering, and Medicine, the event brought together experts working on state-of-the-art, quantum-enabled technologies and scientists who are interested in applying these technologies to biological systems. Through talks, panels, and discussions, the workshop facilitated a better understanding of the current and future biological applications of quantum-enabled technologies in fields such as microbiology, molecular biology, cell biology, plant science, mycology, and many others. The workshop was organized around three main themes. The first, quantum in biology, examined quantum concepts that are hypothesized to be important for life processes and that researchers are working to observe through biological imaging and sensing. The second, quantum for biology, addressed ways to use quantum concepts to enhance technologies for biological imaging and sensing. The third, biology for quantum, offered a wider discussion of how the frontiers of biological imaging and sensing could enable future study using quantum concepts, tools, or technologies. Throughout the workshop, participants identified a wide range of emerging approaches and opportunities at the intersection of quantum physics and biological sensing and imaging. During the workshop, there were some differences in how each speaker defined the term quantum. During one of the panels, Prem Kumar offered thoughts on what phenomena are classical versus quantum, explaining that techniques get progressively more quantum as you move from just having superposition to having superposition with measurement and entanglement. Another explanation from Clarice Aiello delineates the definition into several levels. This includes a base level of “quantum-ness,” which reflects that all matter is made of atoms, and when these particles are isolated they behave based on quantum mechanical principles. A second level is related to quantum coherence, where a single quantum object might be found in a coherent superposition state. A final level, which she described as the quantum-entangled level, involves multiple quantum systems which are entangled among themselves. Overall, the workshop touched on concepts such as superposition, entanglement, and squeezing and their potential implications for communication, computing, and simulation, in addition to the workshop’s main focal area, biological sensing and imaging. At the opening of the workshop, Thorsten Ritz of the University of California, Irvine, identified two questions at the heart of quantum biology: Is the machinery of life quantum mechanical, and can quantum mechanics be used to study the machinery of life in new ways? Participants highlighted systems in which researchers have explored these questions, from the vast array of molecular interactions involved in biological processes such as photosynthesis, to the mechanics involved in cellular functions such as differentiation and aggregation, to the role of oscillating magnetic fields in flight orientation among birds. Sensing and imaging technologies are crucial to biological research; these technologies could both enhance the study of quantum effects and be enhanced by quantum concepts. A critical challenge in biological research is to develop imaging and sensing tools that do not damage or interfere with the often fragile and fleeting systems being studied. Attendees discussed a variety of established and emerging technologies that could enhance noninvasive biological imaging, including single- and two-photon spectroscopy, single-molecule spectroscopy, quantum illumination, ghost imaging, and cryo-electron microscopy. One example came from Marlan Scully who gave a keynote address on the first day of the workshop. Scully emphasized the use of different laser technologies, which exhibit coherence and other quantum properties, in moving toward real-world biological applications, such as the detection of SARS-CoV-2. Both tools and theory will play an important role in advancing quantum biology research and applications. Several participants suggested theorists and experimentalists should work in tandem to understand and model biological processes. While physics often reduces systems to their simplest forms for fundamental insights, participants also noted the value of observing and understanding biological systems in all their “messiness,” capturing both the inner workings of biological systems and the complex interactions that occur within and between organisms. In discussions among participants, several attendees stressed the need to match emerging tools with the right scientific questions. Rather than developing quantum technologies as “a hammer looking for a nail,” participants emphasized a focus on exploring the problems these technologies are best suited to address. For example, it is important to consider the size of the phenomenon being studied, the timescales that are important in answering the scientific question, and other relevant considerations. Every tool along the spectrum from classical to quantum involves its own set of trade-offs. For example, Ted Laurence of the Lawrence Livermore National Laboratory said that quantum measurements, such as single photon counting, fluorescence transitions, and lasers, can take longer to produce the same results as classical measurements. These quantum measurements, however, do not require calibration and can enable new research questions to be answered. Prem Kumar, Northwestern University, noted that, despite their promise, quantum approaches should not be used simply for the sake of using quantum, especially in situations where classical approaches better meet the needs of the researcher. Understanding and applying quantum concepts could enable advances in a wide range of application areas including energy, synthetic biology, medicine, and sustainability. For example, Michelle O’Malley, University of California, Santa Barbara, described how improved noninvasive imaging approaches could help capture the complex interactions and functions involved in the breakdown of organic matter by microbial communities and lead to new technologies for capturing valuable products from plant waste. Several other participants discussed needs in tracking the movement of metabolites and molecules in microbial communities for insights into nutrient cycling in environments such as soil. Margaret Ahmad, Sorbonne University, discussed potential opportunities to leverage the magnetic properties of cryptochromes to advance new treatment approaches for diseases such as COVID-19 and cancer. Looking toward the future development of the field, participants discussed challenges to advancing quantum biology that arise from disciplinary disconnects between physicists and biologists. The siloing of academic research disciplines represents a significant barrier to progress. Disconnects in terminology, motivations and priorities, and structural barriers to collaborative work underscore the need for concerted efforts to bridge these divides. Attendees and speakers offered suggestions for resolving these divergences, establishing a shared language, moving the field forward, and fostering meaningful feedback between disciplines. Overall, participants stressed a need for balance, open communication, collaboration, unity, and clear dialogue on trade-offs between quantum and classical approaches. Keiko Torii, The University of Texas at Austin, said that the best collaborations happen when the project provides mutual advantages that can show off everyone’s talents, each team finds the work interesting, and partners develop a camaraderie to pursue new knowledge. To enable near- and long-term opportunities in this space, participants suggested that exploratory, high-risk funding could improve existing instrumentation to explore quantum enhancement collaboratively. They also emphasized the need for collaboration between quantum physicists and sensing/imaging scientists, which could be advanced through a dedicated quantum biology investigator program. People, even more than technology, will be crucial to the future of quantum biology. Participants explored training, education, and workforce needs to further develop this burgeoning field and cultivate the next generation of scientists. While many programs are still in their nascent stages, participants highlighted examples of approaches and programs being developed at various types of institutions to engage students and professional scientists in quantum biology research. Several participants stressed the need for an inclusive approach, spanning disciplines as well as communities to foster a diverse field fueled by the intellectual contributions of a wide range of people, including historically under-resourced schools and students. To increase awareness and excitement about quantum physics and related areas of biology, attendees suggested capitalizing on the “buzz” around quantum. Several participants emphasized the need to start early, introducing students to quantum concepts and their appealing “weirdness” in K–12 education. Engaging students early—before they become entrenched in traditional disciplinary siloes as typically happens in graduate school—could help to galvanize interest in the area and foster a generation of scientists with the interdisciplinary mindset and skills needed to advance this interdisciplinary field. While these efforts could be advanced at many levels and across multiple sectors, several participants suggested a national quantum biology center could be a valuable hub to coordinate and support quantum biology education and workforce development across academia, industry, and government.

59 BASIC BIOLOGICAL SCIENCES↗

Diagnostics of plasma–liquids systems: Challenges and their mitigation

This article will review two popular methods of laser diagnostics in a plasma–liquid system and generally in low-temperature plasmas. These are Thomson scattering and laser-induced fluorescence. Setting up the plasma–liquid interaction experiment will be described while stressing the important points for laser diagnostics and maintaining conditions for correct and repeatable measurements. In this work, I will discuss the caveats that are encountered when measuring an inherently unstable and collisional system, such as plasma interacting with the liquid and how these challenges impact that data analysis and calibration efforts for these two-diagnostic approaches.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ex situ calibration of the scattered-light time-history diagnostic on the National Ignition Facility

The scattered-light time-history diagnostic (SLTD) suite measures time-resolved scattered light in three wavelength bands: stimulated Brillouin scattering (350–352 nm), stimulated Raman scattering (430–760 nm), and plasma emission at half the laser frequency (695–735 nm), at 15 locations around the National Ignition Facility (NIF) target chamber. The SLTD, along with the full-aperture backscatter station (FABS), collects scattered light from direct- and indirect-drive inertial confinement fusion experiments. The SLTD calibration was revisited after a discrepancy between FABS and SLTD measurements was observed on NIF polar direct-drive experiments. An integrated calibration of the SLTD was performed for the first time, and individual components were also calibrated for the wavelengths of 351, 527, and 532 nm. The optical transmission of the instrument was measured to be (1.12 ± 0.04) × 10 –7 and (1.96 ± 0.11) × 10 –7 for the wavelengths of 351 and 532 nm, respectively. The revised calibration at 351 nm brings the SLTD measured scattered energy in agreement with the FABS measured scattered energy after additionally accounting for the degradation of an optical element in FABS. Furthermore, this decreased the inferred absorption by 7% for a representative experiment. However, discrepancies remain between FABS and SLTD measurements in the SRS band (532 nm).

47 OTHER INSTRUMENTATION↗

Model-based quantification of margins and uncertainties in metal additive manufacturing for process design and qualification

Laser powder bed fusion (LPBF) Additive Manufacturing (AM) has the potential to enable the production of components with novel designs and material properties unachievable otherwise. However, process repeatability is a challenge, making qualification ill-defined and greatly reducing the utility of what could be an important manufacturing technology. In this work, a combination of modeling, uncertainty quantification (UQ), and experimentation are used in an effort to predict and bound the range of possible outcomes of the LPBF process. Quantities of interest predicted are melt pool dimensions, microstructure features, and mechanical distortions. A combination of high fidelity thermal-fluid models, microstructure growth models, and reduced fidelity, rapid thermal and mechanical models are used. Uncertainty propagation techniques are used to predict probability distributions of quantities of interest from estimates of process uncertainties. Repeated experiments are done to quantify observed probability distributions and compared to predicted distributions to determine if predictions are precise and accurate. Novel modeling methods are microstrucutre characterization techniques are also discussed. It is found that high fidelity models do a generally good job bounding experimentally observed melt pool morphologies for both bead-on-plate and powder bed cases. Microstructure models are able to bound a number of experimentally observed microstructure statistics, but with low precision due to challenges with calibrating the microstructure growth model parameters. A developed modified inherent strain distortion model does not accurately predict observed distortions. A lumped laser distortion model shows promise in being both accurately and precisely bounding observed outcomes from the deflection comb build, but requires further evaluation on more builds and geometries.

36 MATERIALS SCIENCE↗

Electro-optical measurement of intense electric field on a high energy pulsed power accelerator

We describe a direct electro-optical approach to measuring a strong 118 MV/m narrow pulse width (~ 33 ns) electric field in the magnetically insulated transmission line (MITL) of a pulsed power accelerator. To date, this is the highest direct external electric field measured electro-optically in a pulsed power accelerator, and it is between two to three orders of magnitude higher than values reported in comparable high energy scientific experiments. The MITL electric field is one of the most important operating parameters in an accelerator and is critical to understanding the properties of the radiation output. However, accurately measuring these high fields using conventional pulsed power diagnostics is difficult due to the strength of interfering particles and fields. Our approach uses a free-space laser beam with a dielectric crystal sensor that is highly immune to electromagnetic interference and does not require an external calibration. Here we focus on device theory, operating parameters, laboratory and pulsed power accelerator experiments as well as challenges that were overcome in the measurement environment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

EPCAPE-PT-LANL Measurements: Single Particle Soot Photometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Single Particle Soot Photometer (Droplet Measurements Technology) Data Notes: Contact us if you want additional data products from this instrument. Reported data is the black carbon (rBC) number and mass concentration with diagnostic flags. The SP2 measures incandescence from particles that is induced with a 1064 Nd-YAG laser. Particles that absorb the laser energy and then emit radiation is assumed to contain black carbon. The amount of intensity of radiation is related to the mass of absorbing material in the particle. Here, we calibrate the incandescence intensity to size selected Regal Black (Cabot) nebulized from solution. Data provided for the EPCAPE campaign used the combined broadband high-gain + low-gain channels (BHBL). Each channel has a lower threshold of detection equivalent to 2-s of the respective channel noise. Thresholding has been applied to select between the high-gain and low-gain channels. The detection limit is 80-540 nm (Deq) or 0.36- 55 fg. It is assumed that rBC is the only aerosol type that is in significant concentration in the sampled atmosphere that absorbs the laser energy. Particle data are integrated over 10 second windows to calculate a rBC number and mass concentration. QC/QA: • Diagnostic flags that impacted measured concentration: - Sample, Sheath, and Purge Flow Rates: Despite observing fluctuations in all flows, the rBC detection and mass quantification are generally observed to be stable, although large changes in sample flow rate did impact detection efficiency. A flag was implemented for sample flow deviations >12 cm3/min from the set point averaged over 30 seconds - Laser Power: Detection efficiency decreases with laser power and deviations in laser power also affect mass quantification. Flag for laser power is set for deviations in laser current from the set value >5 mA. - Primary Detector Threshold: Primary thresholding is the signal value which determines whether a “particle” is recorded. Thresholding errors occur when the threshold value is too HIGH and real particles are ignored. • Several periods without data: - 16-18 Nov: Ultra Zero Air generator failure, flows deviated significantly from set points. rBC # conc recovered but questionable. - 20-21 Nov: Offline for calibrations for several hours each day. - 25-27 Nov: Data is missing. - 30 Nov: Power outage 3 Dec: SP2 hard-drive full. - 3 Dec: Power Outage Header: - BHBL_NumbConc[#/cc]: Refers to the number concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in particles per cubic centimeter. - BHBL_BCMass_Conc[ug/m3]: Refers to the mass concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in micrograms per cubic meter. - NoData_Flag[bool]: A boolean flag that indicates whether no data was recorded during a measurement. - NoBC_Flag[bool]: A boolean flag indicating whether no black carbon particles were recorded during the measurement. - Laser_Flag[bool]: A boolean flag indicating deviations in laser current during the measurement. - SampleFlow_Flag[bool]: A boolean flag indicating deviations from the set sample flow rate during the measurement. - PrimThresh_Flag[bool]: A boolean flag indicating deviations from the set primary threshold during the measurement, potentially ignoring real particles. - Manual_Flag[bool]: A boolean flag indicating manual intervention or adjustments during the measurement. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active or inactive during the measurement.

54 ENVIRONMENTAL SCIENCES↗

Calorimeter with Bayesian unfolding of spectra of high-flux broadband x rays

We report the development of a multipurpose differential x-ray calorimeter with a broad energy bandwidth. The absorber architecture is combined with a Bayesian unfolding algorithm to unfold high energy x-ray spectra generated in high-intensity laser–matter interactions. Particularly, we show how to extract absolute energy spectra and how our unfolding algorithm can reconstruct features not included in the initial guess. The performance of the calorimeter is evaluated via Monte Carlo generated data. The method accuracy to reconstruct electron temperatures from bremsstrahlung is shown to be 5% for electron temperatures from 1 to 50 MeV. We study bremsstrahlung generated in solid target interaction showing an electron temperature of 0.56 ± 0.04 MeV for a 700 μm Ti titanium target and 0.53 ± 0.03 MeV for a 50 μm target. We investigate bremsstrahlung from a target irradiated by laser-wakefield accelerated electrons showing an endpoint energy of 551 ± 5 MeV, inverse Compton generated x rays with a peak energy of 1.1 MeV, and calibrated radioactive sources. The total energy range covered by all these sources ranges from 10 keV to 551 MeV.

47 OTHER INSTRUMENTATION↗

Long-term thermal stability and calibration of Type-II fiber Bragg grating array inscribed in radiation-hardened fibers

This paper investigates the long-term thermal stability of Type-II fiber Bragg grating (FBG) arrays, inscribed by femtosecond laser in radiation-hardened fiber, for potential applications as multiplexed sensors in high-temperature energy systems. The thermal stability of FBG sensors was assessed through 16 thermal cycles from room temperature (RT) to 750 ℃ about two months, involving 100 FBG sensors. The results show that the absolute temperature drift of FBG sensors can be reduced to less than 0.4 pm/day after 54 h thermal annealing process at a constant temperature of 800 ℃. As temperature sensors, the FBGs demonstrated stable performance, achieving a standard deviation (STD) of 1.8 pm (corresponding to a temperature resolution of 0.118 ℃) post-annealing. Repeated thermal cycles revealed a random drift of 2.3 pm in the FBG wavelength at RT. Polynomial fitting was explored as a calibration method to convert FBG wavelength shifts into absolute temperature measurements. By optimizing calibration temperature points (RT, 200 ℃, 400 ℃, and 750 ℃), the study shows that cubic polynomial calibration using four points yields an average R2 of 0.9997 and an RMSE of 3.58 ℃ across the entire temperature range (RT to 750 ℃). This approach represents an 11.53-fold improvement over empirical slope calibration and a 1.34-fold improvement over four-point piecewise fitting. The findings indicate that Type-II FBGs inscribed in radiation-hardened fibers can function as accurate temperature sensors, with performance on par with or exceeding that of thermocouples. With their multiplexing capability, robust signal transmission over long lead cables, and immunity to electromagnetic interference, FBG sensors offer a promising alternative to traditional electronic sensors for energy system monitoring.

Dominguez-Ontiveros, Elvis [ORNL] (ORCID:000000018↗