Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Imaging electron angular distributions to assess a full-power petawatt-class laser focus

Here we present a technique to assess the focal volume of petawatt-class lasers at full power. Our approach exploits quantitative measurement of the angular distribution of electrons born in the focus via ionization of rarefied gas, which are accelerated forward and ejected ponderomotively by the field. We show that a bivariate (θ,Φ) angular distribution, which was obtained with image plates, not only enables the peak intensity to be extracted, but also reflects nonideality of the focal-spot intensity distribution. In our prototype demonstration at intensities of a few ×10 19 to a few ×10 20 W/cm 2 , an f/10 optic produced a focal spot in the paraxial regime. This allows a plane-wave parametrization of the peak intensity given by tanθ c =2/a 0 (a 0 being the normalized vector potential and θ c the minimum ejection angle) to be compared with our measurements. Qualitative agreement was found using an a 0 inferred from the pulse energy, pulse duration, and focal spot distribution with a modified parametrization, tanθ c =2η/a 0 ($η=2.02^{+0.26}_{–0.22}$). This highlights the need for (i) better understanding of intensity degradation due to focal-spot distortions and (ii) more robust modeling of the ejection dynamics. Using single-shot detection of electrons, we showed that while there is significant shot-to-shot variation in the number of electrons ejected at a given angular position, the average distribution scales with the pulse energy in a way that is consistent with that seen with the image plates. Finally, we note that the asymptotic behavior as θ→0° limits the usability of angular measurement. For 800 nm, this limit is at an intensity ~10 21 W/cm 2 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Noninvasive liquid level sensing with laser generated ultrasonic waves

This article proposes a noninvasive liquid level sensing technique using laser-generated ultrasound waves for nuclear power plant applications. Liquid level sensors play an important role of managing the coolant system safely and stably in the plant structure. Current sensing techniques are mostly intrusive, performing inside the fluidic structure, which is disadvantageous in terms of the regular maintenance of the plant system. Furthermore, typical intrusive sensors do not perform stably under varying environmental conditions such as temperature and radiation. In this study, sensing units are attached to the outer surface of a liquid vessel to capture guided ultrasound waves in a nonintrusive manner. The signal intensity of the guided wave dissipates when the signal interacts with the internal liquid media. The sensing mechanism is mathematically expressed as an index value to correlate the liquid level with the sensor signal. For the acoustic wave generation, laser-generated ultrasound was adopted instead of using typical contact type transducers. Following the simulation validation of the proposed concept, the performance of the developed sensor was confirmed through experimental results under elevated liquid temperature conditions. Finally, the nonlinear multivariable regression exhibited the best-fit to the datasets measured under the variable liquid level and temperature conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding Flow Characteristics in Metal Additive Manufacturing

In fluid flow, the frictional effects from interior surfaces of flow components create pressure loss across the surface. Understanding this inherent pressure loss due to friction and other phenomena is important when designing a flow system. For conventional manufacturing, friction loss has been empirically studied and is well known in the engineering community. However, newer manufacturing techniques, such as laser powder bed fusion (LPBF), an additive manufacturing technique, need to be understood. The inherent flow conditions resulting from the additive processes were studied. Test samples were printed with the flow path oriented in the vertical direction with different channel diameters to characterize the inherent fundamental flow properties of the process. Moody diagrams were replicated for a greater understanding of possibilities and shortfalls when implementing LPBF into design applications. Experimental flow testing revealed that greater effective sand grain roughness resulted from this process when compared to conventional machining methods. This roughness did not correlate well to the average roughness measured with a laser scanning microscope but was consistent with the average particle size of the powder metal feedstock.

42 ENGINEERING↗

Measuring the effectiveness of high-performance Co-Optima biofuels on suppressing soot formation at high temperature

Soot emissions in combustion are unwanted consequences of burning hydrocarbon fuels. The presence of soot during and following combustion processes is an indication of incomplete combustion and has several negative consequences including the emission of harmful particulates and increased operational costs. Efforts have been made to reduce soot production in combustion engines through utilizing oxygenated biofuels in lieu of traditional nonoxygenated feedstocks. The ongoing Co-Optimization of Fuels and Engines (Co-Optima) initiative from the US Department of Energy (DOE) is focused on accelerating the introduction of affordable, scalable, and sustainable biofuels and high-efficiency, low-emission vehicle engines. The Co-Optima program has identified a handful of biofuel compounds from a list of thousands of potential candidates. In this study, a shock tube was used to evaluate the performance of soot reduction of five high-performance biofuels downselected by the Co-Optima program. Current experiments were performed at test conditions between 1,700 and 2,100 K and 4 and 4.7 atm using shock tube and ultrafast, time-resolve laser absorption diagnostic techniques. The combination of shock heating and nonintrusive laser detection provides a state-of-the-art test platform for high-temperature soot formation under engine conditions. Soot reduction was found in ethanol, cyclopentanone, and methyl acetate; conversely, an α-diisobutylene and methyl furan produced more soot compared to the baseline over longer test times. For each biofuel, several reaction pathways that lead towards soot production were identified. The data collected in these experiments are valuable information for the future of renewable biofuel development and their applicability in engines.

09 BIOMASS FUELS↗

Spatiotemporal control of high-intensity laser pulses with a plasma lens

Spatiotemporal control encompasses a variety of techniques for producing laser pulses with dynamic intensity peaks that move independently of the group velocity. This controlled motion of the intensity peak offers a new approach to optimizing laser-based applications and enhancing signatures of fundamental phenomena. Here, we demonstrate spatiotemporal control with a plasma optic. A chirped laser pulse focused by a plasma lens exhibits a moving focal point, or “flying focus,” that can travel at an arbitrary, predetermined velocity. Unlike currently used conventional or adaptive optics, a plasma lens can be located close to the interaction region and can operate at an orders of magnitude higher, near-relativistic intensity. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interactions between Surface Chemistry and Gas-Phase Combustion: New Optical Tools for Probing Flame-Wall Interactions and the Heterogeneous Chemistry of Soot Growth and Oxidation in Flame. Final report

Some of the most stubborn and technologically critical problems in combustion are dominated by heterogeneous processes. While purely gas-phase combustion systems have been the subject of intense theoretical and experimental study, combustion phenomena occurring at interfaces are far less understood. This is partly caused by the lack of experimental approaches capable of probing locations very close to an interface, especially in the hostile environment of combustion. For laser-based optical techniques, measurements taken near interfaces are often complicated by laser scattering from the surface interfering with relatively weak signals. Further, for measurements intended to probe molecular species adsorbed at the interface between a gas-phase combustion reaction and a condensed phase material, signals are generally overwhelmed by contributions from the bulk phases, causing the small contribution from the interfacial molecular species to be undetectable. Our goal in this project has been to develop new optical tools for imaging chemical species, temperature, and surface species at and near surfaces or interfaces of relevance to combustion. We have placed focus on the development and refinement of ultrafast techniques such as femtosecond coherent Raman imaging and femtosecond/picosecond sum-frequency generation (SFG) scattering, as well as the models used to simulate such spectra under differing conditions of pressure and chemical speciation. The two physical phenomena initially targeted for study in this project were flamewall interactions, and the growth of particulates in flames.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatio-temporally shaped deep UV laser source for ultrabright photocathodes using novel upconversion techniques (Final Report)

The goal of this project was to take a VUV laser system designed by Kapteyn-Murnane Labs (KMLabs)—the Hyperion VUV, and increase its functionality, efficiency, and applicability by further probing the fundamental physics taking place in the system and optimizing the system performance. More specifically, DOE accelerator applications—particularly for XFELs that require low-emittance electron beams, require precisely controlled ultrashort pulses in the deep-UV at 250-260 nm to drive the photocathode electron source. This is conventionally done using an ultrafast infrared laser, with subsequent stages of nonlinear upconversion in solid-state nonlinear-optical crystal media (principally BBO, which is commonly used for UV upconversion). However, maintaining high spatial mode beam quality, as well as precisely controlled temporal profile, has proven a persistent challenge. As a possible alternative to this approach, KMLabs has demonstrated a system that generates vacuum ultraviolet light (VUV) by upconverting pulses from an infrared ultrafast laser in a gas-filled hollow waveguide, driving a process of highly cascaded harmonic generation (HCHG). Because HCHG upconversion is done in a gas, rather than a solid, at high intensity in a guided-wave geometry, it retains an excellent beam spatial profile as well as a large spectral bandwidth that allows for control over the temperal structure of the pulse. A challenge, however, is in energy scaling of this HCHG technique to the ~1-20 μJ pulses required for photocathode applications. To-date, the pulse energies used in published HCHG work are sub-10-nJ. This project proposed to explore ways to generate higher-energy pulses using HCHG, as well as to investigate spectral and temporal shaping of the deep UV pulses by pulse shaping the infrared laser used to seed the process. Although we showed that our approach works for generating light at 259 nm, the total pulse energy achieved seems limited to approximately the same value as past work. However, the techniques we investigated may well have benefits for extending this source to much shorter wavelength output.

43 PARTICLE ACCELERATORS↗

High speed laser-induced refractive index change in ophthalmic HEMA hydrogel using a line focus

Laser-induced refractive index change (LIRIC) techniques typically focus femtosecond laser pulses to a tight spot to achieve the high intensities required to alter ophthalmic materials. A line-focus implementation using 800 nm pulses at 1 kHz repetition rate has been shown to greatly increase the effective writing speed of the process, but the high pulse energies used led to nonlinear propagation effects, presenting challenges for the fabrication of ophthalmic correctors. By taking advantage of the lower effective order of multiphoton absorption for 514 nm pulses, power levels may be reduced, allowing overlapped pulse writing. We demonstrate that this allows high-quality phase bars and devices to be made at high speeds.

Manning, Zachary A. [University of Rochester, NY (↗

ElementLIBS User's Guide: An operational aid for use and development

Laser-Induced Breakdown Spectroscopy or LIBS is a rapid, in-situ analytical technique where a laser of known energy is pulsed at the surface of an analyte. The laser pulse rapidly heats a localized area to many thousand degrees Kelvin, ablating part of the analyte and turning it into a plasma. As the plasma cools, excited atoms return to a ground state with known emission energies. This emitted energy is captured by various spectrometers and provides a spectrum of the emitted energies and intensities. This spectrum can be analyzed to provide the elemental composition of a sample by using known emission lines and relative abundance. ElementLIBS was developed for the SciAps hand-held LIBS model Z300 but will work with any model that provides a LIBS spectrum of similar resolution. The Z300 has an integrated resolution of 1/30 nm with a range of approximately 180nm – 960nm, providing an output spectrum of 23431 pixels across three spectrometers. These criteria are only provided as a reference, as the software was designed to work with any size spectrum, provided the input file is of the correct format and the models were developed using the same framework. If spectra of varying dimensions are used, the software will fail without warning and unusual events could occur.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of proton deflectometry with in situ x-ray fiducial for magnetized high-energy-density systems

We report a design and implementation of proton deflectometry with an in situ reference x-ray image of a mesh to precisely measure non-uniform magnetic fields in expanding plasmas at the OMEGA and OMEGA EP laser facilities. The technique has been developed with proton and x-ray sources generated from both directly driven capsule implosions and short pulse laser–solid interactions. The accuracy of the measurement depends on the contrast of both the proton and x-ray images. Here we present numerical and analytic studies to optimize the image contrast using a variety of mesh materials and grid spacings. Our results show clear enhancement of the image contrast by factors of four to six using a high Z mesh with large grid spacing. This leads to further improvement in the accuracy of the magnetic field measurement using this technique in comparison with its first demonstration at the OMEGA laser facility [Rev. Sci. Instrum. 93, 023502 (2022) [CrossRef]].

47 OTHER INSTRUMENTATION↗

Laser-induced fluorescence thermometry of supercritical CO 2 flows inside a micro-channel

This work demonstrates a thermometric technique using laser-induced fluorescence (LIF) in supercritical carbon dioxide flows in a micro-channel. Rhodamine 6G was used as a temperature-sensitive fluorescent dye. The flow conditions were at a pressure of 7.9 MPa and temperature in the range of 23°–90°C. 2D spatial distributions and time-resolved temperature profiles were obtained at this high pressure. Measured LIF signals showed close relations to the temperatures obtained from resistance temperature detectors.

Park, Suhyeon↗

Spatiotemporal control of laser intensity using differentiable programming

Optical techniques for spatiotemporal control can produce laser pulses with custom amplitude, phase, or polarization structure. In nonlinear optics and plasma physics, the use of structured pulses typically follows a forward design approach, in which the efficacy of a known structure is analyzed for a particular application. Inverse approaches, in contrast, enable the discovery of new structures with the potential for superior performance. Here, an implementation of the unidirectional pulse propagation equation that supports automatic differentiation is combined with gradient-based optimization to design structured pulses with features that are advantageous for a range of nonlinear optical and plasma-based applications: (1) a longitudinally uniform intensity over an extended region, (2) a superluminal intensity peak that travels many Rayleigh ranges with constant duration, spot size, and amplitude, and (3) a laser pulse that ionizes a gas to form a uniform column of plasma. In the final case, optimizing the full spatiotemporal structure improves the performance by a factor of 15 compared to optimizing only spatial or only temporal structure, highlighting the advantage of spatiotemporal control.

automatic differentiation↗

Collaborative Research: Enhancing Laser-Based Ion Sources with High Data Rate Techniques

This collaborative research project focuses on leveraging advanced machine learning techniques to analyze and optimize data from high-repetition-rate laser experiments. The main goal is to apply modern computing hardware, customized data acquisition firmware/software, and machine learning approaches to improve data analysis and experimental control. The project also explores how methodology can be developed on smaller-scale experimental setups and then translated to larger facilities within DOE's LaserNetUS network. With extensive data collection and modeling, the research aims to predict and optimize experimental parameters to enhance performance and efficiency.

47 OTHER INSTRUMENTATION↗

Enhanced sensitivity for electron affinity measurements of rare elements

The electron affinity (EA), the energy released when a neutral atom binds an additional electron, is a fundamental property of atoms that is governed by electron-electron correlations and is strongly related to an element’s chemical reactivity. However, conventional techniques for EA determination lack the experimental sensitivity to probe very scarce samples. As a result, the EA for the heaviest elements of the periodic table is entirely uncharted. Here, we present a novel technique to determine EAs through Laser Photodetachment Threshold Spectroscopy, performed in an electrostatic ion beam trap to increase the samples’ exposure to laser photons and, thus, improve the experimental signal sensitivity by three orders of magnitude. Moreover, the additional exposure time allows the use of lower-power continuous-wave narrow-band lasers that reduce uncertainties associated with broadening effects induced by the laser bandwidth. By applying this technique, we measure the EA of 35 Cl to be 3.612720(44) eV, achieving state-of-the-art precision while employing five orders of magnitude fewer anions. The demonstrated sensitivity paves the way for systematic EA measurements across isotopic chains - including isotope shifts and hyperfine splittings - and ultimately for the first direct determination of electron affinities in superheavy elements.

Maier, F. M. [Univ. of Greifswald (Germany); Europ↗

Fiber coupled laser ultrasound system using a single mode hollow core fiber for excitation laser: Theory and demonstration for on-machine thickness gauging

Laser ultrasound (LU) is a technique that uses a pump laser and a probe laser to optically generate and detect elastic waves in a material. Despite its advantages over traditional contact transducer-based ultrasound, industrial adoption has been limited by complex optical setups and the inability of multi-mode fibers to deliver a stable Gaussian profile for the pump laser. Here, we report a fully fiber-coupled thermoelastic LU system that uses an anti-resonant hollow-core single-mode fiber to deliver 1 mJ nanosecond pulses of 1064 nm light, while preserving the fundamental Gaussian mode (pump laser). When combined with a fiber-coupled interferometer (probe laser), a small, flexible, and environmentally robust sensor capable of optically generating and detecting high frequency broadband ultrasound is realized. We demonstrate such an LU system implemented in situ on a four-axis precision lathe. High-resolution thickness gauging is performed, before and after precision cutting, by exciting and measuring a zero-group velocity guided wave mode. The measurements are verified with ex-situ traceable coordinate measuring machine data. Mean absolute deviations of 0.1%, of nominal thickness, before cutting, and 0.2% and 0.3%, after stepped and tapered cuts, respectively, are reported. A theoretical background for thermoelastic ultrasound generation in an elastic waveguide is also presented. Attention is given to the effect of the pump laser profile on wave generation to elucidate the importance of using single-mode laser light. The fiber-coupled system demonstrated is well-suited for use in scientific and engineering sensing applications and facilitates the adoption of LU for industrial non-destructive testing.

Engineering↗

Neutron Characterization of 3D Printed Gas Turbine Alloy With Internal Cooling Structure

The objective of this research work is to investigate the residual strains induced by the presence of a exit hole and internal hollow geometry present in a 3D printed IN718 similar to that seen in a gas turbine blade. The specimens were manufactured with an internal hollow structure that ended with an exit hole, and fabricated by direct metal laser sintering additive manufacturing technique. Using this technique, metal powder was melted by a laser source and rapidly cooled to form the part layer by layer. Rapid heating and cooling generate large thermal gradients and residual stresses in the 3D printed material. To be aligned with industry standards, specimens were heat-treated to relieve most of the residual stresses as well as to investigate whether IN718 still preserved a nonhomogeneous stress state after the thermal treatment. Roughness and microstructure analysis was performed to understand the heat-treated sample properties. To investigate the volumetric residual strain, the neutron diffraction technique was used with a definite neutron wavelength. Bragg’s law was used to determine lattice spacing. Interplanar lattice spacing and stress-free state lattice spacings were measured to calculate the strains. Residual strains were measured in the x and y direction to understand the impact of the presence of a exit hole and internal hollow geometry. The results of volumetric residual strain in the x and y directions showed no significant variations in the distribution of the strain due to the presence of a hollow structure as well as the exit hole. Overall, no significant stress concentration was observed in the heat treated sample. Sample geometry, instrumentation for neutron diffraction, and material properties are discussed in detail in this paper.

Raju, Nandhini↗

Longitudinal shaping of plasma waveguides using diffractive axicons for laser wakefield acceleration

New techniques for the optical generation of plasma waveguides—optical fibers for ultra-intense light pulses—have become vital to the advancement of multi-GeV laser wakefield acceleration. Here, we demonstrate the fabrication and characterization of a transmissive 8-level logarithmic diffractive axicon (LDA) for the generation of meter-scale plasma waveguides. These LDAs enable the formation of a Bessel-like beam with controllable start and end locations of the focal line and near-constant intensity on axis. We present measurements of the Bessel-like focal profile produced by the LDA and of the leading end of the plasma column generated by it. One important feature is the formation of a funnel-mouthed plasma channel entrance that can act as waveguide coupler. We also compare the diffraction efficiency of our 8-level LDA to 4-level and binary versions, with measurements comparing well to theory.

Tripathi, N.↗