Search NASA⌕ Search

SEARCH · Search NASA

Results for “Latent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Simulation and evaluation of latent heat thermal energy storage

The relative value of thermal energy storage (TES) for heat pump storage (heating and cooling) as a function of storage temperature, mode of storage (hotside or coldside), geographic locations, and utility time of use rate structures were derived. Computer models used to simulate the performance of a number of TES/heat pump configurations are described. The models are based on existing performance data of heat pump components, available building thermal load computational procedures, and generalized TES subsystem design. Life cycle costs computed for each site, configuration, and rate structure are discussed.

Sigmon, T. W.↗

Active heat exchange system development for latent heat thermal energy storage

Alternative mechanizations of active heat exchange concepts were analyzed for use with heat of fusion Phase Change Materials (PCM's) in the temperature range of 250 C to 350 C for solar and conventional power plant applications. Over 24 heat exchange concepts were reviewed, and eight were selected for detailed assessment. Two candidates were chosen for small-scale experimentation: a coated tube and shell that exchanger, and a direct contact reflux boiler. A dilute eutectic mixture of sodium nitrate and sodium hydroxide was selected as the PCM from over fifty inorganic salt mixtures investigated. Preliminary experiments with various tube coatings indicated that a nickel or chrome plating of Teflon or Ryton coating had promise of being successful. An electroless nickel plating was selected for further testing. A series of tests with nickel-plated heat transfer tubes showed that the solidifying sodium nitrate adhered to the tubes and the experiment failed to meet the required discharge heat transfer rate of 10 kW(t). Testing of the reflux boiler is under way.

Lefrois, R. T.↗

Active heat exchange system development for latent heat thermal energy storage

Various active heat exchange concepts were identified from among three generic categories: scrapers, agitators/vibrators and slurries. The more practical ones were given a more detailed technical evaluation and an economic comparison with a passive tube-shell design for a reference application. Two concepts selected for hardware development are a direct contact heat exchanger in which molten salt droplets are injected into a cooler counterflowing stream of liquid metal carrier fluid, and a rotating drum scraper in which molten salt is sprayed onto the circumference of a rotating drum, which contains the fluid heat sink in an internal annulus near the surface. A fixed scraper blade removes the solidified salt from the surface which has been nickel plated to decrease adhesion forces. Suitable phase change material (PCM) storage media with melting points in the temperature range of interest (250 C to 400 C) were investigated. The specific salt recommended for laboratory tests was a chloride eutectic (20.5KCl-24/5 NaCl-55.0MgCl 2% by wt.), with a nominal melting point of 385 C.

Alario, J.↗

Active heat exchange system development for latent heat thermal energy storage

Five tasks to select, design, fabricate, test and evaluate candidate active heat exchanger modules for future applications to solar and conventional utility power plants were discussed. Alternative mechanizations of active heat exchange concepts were analyzed for use with heat of fusion phase change materials (PCMs) in the temperature range of 250 to 350 C. Twenty-six heat exchange concepts were reviewed, and eight were selected for detailed assessment. Two candidates were selected for small-scale experimentation: a coated tube and shell heat exchanger and a direct contact reflux boiler. A dilute eutectic mixture of sodium nitrate and sodium hydroxide was selected as the PCM from over 50 candidate inorganic salt mixtures. Based on a salt screening process, eight major component salts were selected initially for further evaluation. The most attractive major components in the temperature range of 250 to 350 C appeared to be NaNO3, NaNO2, and NaOH. Sketches of the two active heat exchange concepts selected for test are given.

Lefrois, R. T.↗

Metal-halide mixtures for latent heat energy storage

Alkali metal and alkali halide mixtures are identified which may be suitable for thermal energy storage at temperatures above 600 C. The use of metal-halides is appropriate because of their tendency to form two immiscible melts with a density difference, which reduces scale formation and solidification on heat transfer surfaces. Also, the accumulation of phase change material along the melt interface is avoided by the self-dispersing characteristic of some metal-halides, in particular Sr-SrCl2, Ba-BaCl2, and Ba-BaBr2 mixtures. Further advantages lie in their high thermal conductivities, ability to cope with thermal shock, corrosion inhibition, and possibly higher energy densities.

Chen, K.↗

Non-quasi-geostrophic effects in baroclinic waves with latent heat release

A study is conducted for the non-quasi-geostrophic baroclinic wave effects in a saturated atmosphere whose vertical motion is subject to pseudo-adiabatic processes. With respect to the characteristics of energetics for the first-order solution, it is noted that, in the cases of both the dry mode and the first moist mode, the heat transport quantities due to the second-order eddy are small and opposite in sign to their respective transports. The non-quasi-geostrophic effects render the vertical motion field asymmetric in each of the regions involved and enter into the present treatment only as nonlinear terms. The moisture transport terms in the eddy-available potential energy equation is small by comparison to other individual terms in the cyclone scale motion's energetics calculation. This is consistent with the observational results of Smith (1980).

Fichtl, G. H.↗

Advanced latent heat of fusion thermal energy storage for solar power systems

The use of solar thermal power systems coupled with thermal energy storage (TES) is being studied for both terrestrial and space applications. In the case of terrestrial applications, it was found that one or two hours of TES could shift the insolation peak (solar noon) to coincide with user peak loads. The use of a phase change material (PCM) is attractive because of the higher energy storage density which can be achieved. However, the use of PCM has also certain disadvantages which must be addressed. Proof of concept testing was undertaken to evaluate corrosive effects and thermal ratcheting effects in a slurry system. It is concluded that the considered alkali metal/alkali salt slurry approach to TES appears to be very viable, taking into account an elimination of thermal ratcheting in storage systems and the reduction of corrosive effects. The approach appears to be useful for an employment involving temperatures applicable to Brayton or Stirling cycles.

Phillips, W. M.↗

Latent energy storage with salt and metal mixtures for solar dynamic applications

This paper examines three design alternatives for the development of a solar dynamic heat receiver as applied to power systems operating in low earth orbit. These include a base line design used for comparison in ongoing NASA studies, a system incorporating a salt energy storage system with the salt dispersed within a metal mesh and a hybrid system incorporating both a molten salt and molten metal for energy storage. Based on a typical low earth orbit condition, designs are developed and compared to determine the effect of resultant conductivity, heat capacity and heat of fusion on system size, weight, temperature gradients, cycle turbine inlet temperature and material utilization.

Crane, R. A.↗

Net radiation, sensible and latent heat flux densities on slopes computed by the energy balance method

Energy balance components obtained over five grass-covered sloping surfaces near Manhattan, KS, using the Bowen ratio energy balance technique with the instruments mounted horizontally were compared with calculated values when the instruments were mounted parallel to the surfaces. Hourly values of the components changed when the instruments were parallel to the surfaces. The changes were larger at low solar angles (spring and fall) and on steeper slopes. An area average of daylight totals, assuming that all aspects were equally represented, changed only 0.1 percent on June 6 and 2.3 percent on October 11. The calculations, extended to steeper slopes, indicated small changes in the daylight totals for slopes of less than 10 deg.

Fritschen, Leo↗

Detecting Latent Faults In Digital Flight Controls

Report discusses theory, conduct, and results of tests involving deliberate injection of low-level faults into digital flight-control system. Part of study of effectiveness of techniques for detection of and recovery from faults, based on statistical assessment of inputs and outputs of parts of control systems. Offers exceptional new capability to establish reliabilities of critical digital electronic systems in aircraft.

Mcgough, John↗

Spatial and temporal variations of CO2, sensible and latent heat fluxes over the FIFE site

The temporal and spatial variations of mass and energy exchanges are characterized by data taken from grid flights at a constant pressure altitude. Data from two separate studies are presented to demonstrate that the correlation coefficients increase with improved estimates of the origin of mass and energy exchange. Measurements taken from aircraft can effectively describe relationships between surface processes and vegetation characteristics on a regional scale.

Desjardins, R. L.↗

Evaluation of sensible heat flux, latent heat flux, and effective aerodynamic roughness at the land surface from a combination of satellite and in-situ data

A simple method is presented for using the daytime rise of the PBL height, combined with coincident satellite skin temperature measurements, to evaluate sensible heating and the effective surface roughness for heat transfer at synoptic locations. Multiple runs of a combination surface layer-mixed layer model are made in the central U.S., varying the values of surface moisture and roughness length around climatological means, and initializing the model with a set of atmospheric conditions from the synoptic report. The results, shown in figures and tables, are quite reasonable and spatially coherent, and depict well the sharp change in surface moisture and roughness which is known to take place across the central U.S.

Diak, George R.↗

Estimating the daily course of Konza Prairie latent heat fluxes using a modified Tergra model

Experimental tests of the Tergra-2 model are based on data collected under moderately wet to wet and very dry soil moisture conditions. Further testing of the model under intermediate soil moisture conditions is required and additional testing under very dry conditions may lead to modifications that make the model more suitable to water-stressed conditions. Combining the Tergra model with a soil evaporation routine should enhance the accuracy of the model and allow it to be employed in situations where vapor fluxes are not almost solely attributable to transpiration.

Hope, Allen S.↗

Environmental Forcing of Super Typhoon Paka's (1997) Latent Heat Structure

The distribution and intensity of total (i.e., combined stratified and convective processes) rainrate/latent heat release (LHR) were derived for tropical cyclone Paka during the period 9-21 December, 1997 from the F-10, F-11, F-13, and F-14 Defense Meteorological Satellite Special Sensor Microwave/Imager and the Tropical Rain Measurement Mission Microwave Imager observations. These observations were frequent enough to capture three episodes of inner core convective bursts that preceded periods of rapid intensification and a convective rainband (CRB) cycle. During these periods of convective bursts, satellite sensors revealed that the rainrates/LHR: 1) increased within the inner eye wall region; 2) were mainly convectively generated (nearly a 65% contribution), 3) propagated inwards; 4) extended upwards within the middle and upper-troposphere, and 5) became electrically charged. These factors may have caused the eye wall region to become more buoyant within the middle and upper-troposphere, creating greater cyclonic angular momentum, and, thereby, warming the center and intensifying the system. Radiosonde measurements from Kwajalein Atoll and Guam, sea surface temperature observations, and the European Center for Medium Range Forecast analyses were used to examine the necessary and sufficient condition for initiating and maintaining these inner core convective bursts. For example, the necessary conditions such as the atmospheric thermodynamics (i.e., cold tropopause temperatures, moist troposphere, and warm SSTs [greater than 26 deg]) suggested that the atmosphere was ideal for Paka's maximum potential intensity (MPI) to approach super-typhoon strength. Further, Paka encountered weak vertical wind shear (less than 15 m/s ) before interacting with the westerlies on 21 December. The sufficient conditions, on the other hand, appeared to have some influence on Paka's convective burst, but the horizontal moisture flux convergence values in the outer core were weaker than some of the previously examined tropical cyclones. Also, the upper tropospheric outflow generation of eddy relative angular momentum flux convergence was 4D much less than that found during moderate tropical cyclone/trough interaction. These results indicated how important the external necessary condition and the internal forcing (i.e., CRB cycle) were in generating Paka's convective bursts as compared to the external sufficient forcing mechanisms found in higher latitude tropical cyclones. Later, as Paka began to interact with the westerlies, both the necessary (i.e., strong vertical shear and colder SSTs) and sufficient (i.e., dry air intrusion) external forcing mechanisms helped to decrease Paka's rainrate.

Rodgers, Edward B.↗

Northwestern Tharsis Latent Outflow Activity Mars

Previously defined outflow channels, which are indicated by relict landforms similar to those observed on Earth, signify ancient catastrophic flood events on Mars. These conspicuous geomorphic features are some of the most remarkable yet profound discoveries made by geologists to date. These outflow channels, which debouched tremendous volumes of water into topographic lows such as Chryse, Utopia, Elysium, and Hellas Planitiae, may represent the beginning of warmer and wetter climatic periods unlike the present-day cold and dry Mars. In addition to the previously identified outflow channels, observations permitted by the newly acquired Mars Orbiter Laser Altimeter (MOLA) data have revealed a system of gigantic valleys, referred to as the northwestern slope valleys (NSV), that are located to the northwest of a huge shield volcano, Arsia Mons, western hemisphere of Mars. These features generally correspond spatially to gravity lows similar to the easternmost, circum-Chryse outflow channel systems. Geologic investigations of the Tharsis region suggest that the large valley system pre-dates the construction of Arsia Mons and its extensive associated lava flows of mainly Late Hesperian and Amazonian age and coincides stratigraphically with the early development of the circum-Chryse outflow channel systems that debouch into Chryse Planitia. This newly identified system, the NSV, potentially signifies the largest flood event(s) ever recorded for the solar system. Additional information is contained in original extended abstract.

Dohm, J. M.↗