Search NASA⌕ Search

SEARCH · Search NASA

Results for “Leak Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Assessing MMOD Impacts on Seal Performance

The elastomer seal needed to seal in cabin air when NASA s Crew Exploration Vehicle is docked is exposed to space prior to docking. While open to space, the seal might be hit by orbital debris or meteoroids. The likelihood of damage of this type depends on the size of the particle. Our campaign is designed to find the smallest particle that will cause seal failure resulting in loss of mission. We will then be able to estimate environmental risks to the seal. Preliminary tests indicate seals can withstand a surprising amount of damage and still function. Collaborations with internal and external partners are in place and include seal leak testing, modeling of the space environment using a computer code known as BUMPER, and hypervelocity impact (HVI) studies at Caltech. Preliminary work at White Sands Test Facility showed a 0.5 mm diameter HVI damaged areas about 7 times that diameter, boring deep (5 mm) into elastomer specimens. BUMPER simulations indicate there is a 1 in 1440 chance of getting hit by a particle of diameter 0.08 cm for current Lunar missions; and 0.27 cm for a 10 year ISS LIDS seal area exposure.

deGroh, Henry C., III↗

Evaluations of Candidate Materials for Advanced Space-Rated Vacuum Seals to Explore Space Environment Exposure Limits

For many materials used in space hardware, the environment in which they need to operate is harsher than the environment on earth. Exposure to vacuum conditions, atomic oxygen, and ultraviolet radiation can be detrimental, so testing of space hardware in simulated space environments is required. This is especially true for elastomeric components such as seals. NASA is developing advanced space-rated vacuum seals in support of future space exploration missions. These seals must exhibit extremely low leak rates to ensure that astronauts have sufficient breathable air during extended-duration missions. In some applications the seals are not mated during portions of the mission and are left uncovered and exposed to the conditions in space for prolonged periods of time prior to mating. Space-rated vacuum seals are often made of silicone because of the material's wide operating temperature range and ability to be molded or extruded into various shapes and cross sections. One approach being considered to achieve improved performance is to add titanium dioxide to the silicone material to make it more resistant to damage from ultraviolet radiation. In this study, seals made of the baseline material with and without 1.5 percent titanium dioxide additive (by weight) were exposed to atomic oxygen and increasing levels of ultraviolet radiation and then leak tested. Test results revealed that seals made of the new material could withstand longer exposures while still satisfying the leak rate requirement even under worst-case conditions of partial compression at the extremes of the anticipated operating temperature range.

Seals↗

Evaluations of Candidate Materials for Advanced Space-Rated Vacuum Seals to Explore Space Environment Exposure Limits

For many materials used in space hardware, the environment in which they need to operate is harsher than the environment on earth. Exposure to vacuum conditions, atomic oxygen, and ultraviolet radiation can be detrimental, so testing of space hardware in simulated space environments is required. This is especially true for elastomeric components such as seals. NASA is developing advanced space-rated vacuum seals in support of future space exploration missions. These seals must exhibit extremely low leak rates to ensure that astronauts have sufficient breathable air during extended-duration missions. In some applications the seals are not mated during portions of the mission and are left uncovered and exposed to the conditions in space for prolonged periods of time prior to mating. Space-rated vacuum seals are often made of silicone because of the material's wide operating temperature range and ability to be molded or extruded into various shapes and cross sections. One approach being considered to achieve improved performance is to add titanium dioxide to the silicone material to make it more resistant to damage from ultraviolet radiation. In this study, seals made of the baseline material with and without 1.5% titanium dioxide additive (by weight) were exposed to atomic oxygen and increasing levels of ultraviolet radiation and then leak tested. Test results revealed that seals made of the new material could withstand longer exposures while still satisfying the leak rate requirement even under worst-case conditions of partial compression at the extremes of the anticipated operating temperature range.

Ultraviolet radiation↗

Embedding of Optical Fibers with Electric Field Assisted Sintering

The Electric Field Assisted Sintering (EFAS) technique was used for embedding the fibers, involving rapid heating via an electric current and pressure, reducing fiber exposure to high temperatures. Stainless steel guide tubes were inserted at the fiber-matrix junctions to prevent fiber breakage during the sintering process. The study varied key EFAS parameters—temperature (800°C to 980°C), pressure (40-50 MPa), and hold time (5-10 minutes)—to assess how they influenced fiber embedding. After embedding, the fibers were inspected using optical frequency domain reflectometry (OFDR) to evaluate optical losses and strain along the fiber length. The OFDR scans confirmed that the fibers remained intact, and subsequent transmission tests demonstrated no macroscopic fractures. The embedded samples were also analyzed using scanning electron microscopy (SEM) and X-ray computed tomography (CT) scans. These tests confirmed good bonding between the fiber and matrix with no cracking, though some porosity was present in samples fabricated at lower temperatures. At higher temperatures (980°C), the fiber-matrix bonding was continuous and defect-free, with metal coatings aiding in the bonding process. Elemental analysis showed interdiffusion between the fiber coatings and matrix materials, particularly between the gold coating and stainless steel. Helium leak tests revealed that lower sintering temperatures resulted in matrix porosity, causing leaks, but samples fabricated at 980°C were leak-tight.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Performance of all-metal demountable cryogenic seals at superfluid helium temperatures

Two all-metal demountable cryogenic seals with an outside diameter of 36.6 mm, inside diameter of 27.2 mm and thickness of 0.51 mm were leak-tested at room temperature (300 K), liquid nitrogen temperature (21 cycles at 77 K), liquid helium temperature (nine cycles at 4.2K) and superfluid helium temperature (four cycles at 1.6 K). Each seal was mounted and demounted for 13 cycles. Thickness measurements at 90 deg intervals along the circumference showed a maximum seal compression of 0.038 mm. Leak rate measurements at all temperatures showed no detectable leak above the helium background level, typically 0.1 x 10 exp -9 std cu cm/s, during testing.

Salerno, L. J.↗

Performance of all-metal demountable cryogenic seals at superfluid helium temperatures

Two all-metal demountable cryogenic seals with an outside diameter of 36.6 mm, inside diameter of 27.2 mm, and thickness of 0.51 mm were leak-tested at room temperature (300 K), liquid nitrogen temperature (21 cycles at 77 K), liquid helium temperature (9 cycles at 4.2 K), and susperfluid helium temperature (4 cycles at 1.6 K). Each seal was mounted and demounted for 13 cycles. Thickness measurements at 90 deg intervals along the circumference showed a maximum seal compression of 0.038 mm. Leak-rate measurements at all temperatures showed no detectable leak above the helium background level, typically 0.1 x 10(-9) std-cc/sec, during testing.

Salerno, Louis J.↗

Performance of all-metal demountable cryogenic seals at superfluid helium temperatures

Two all-metal demountable cryogenic seals with an outside diameter of 36.6 mm, inside diameter of 27.2 mm, and thickness of 0.51 mm were leak-tested at room temperature (300 K), liquid nitrogen temperature (21 cycles at 77 K), liquid helium temperature (9 cycles at 4.2 K), and superfluid helium temperature (4 cycles at 1.6 K). Each seal was mounted and demounted for 13 cycles. Thickness measurements at 90 deg intervals along the circumference showed a maximum seal compression of 0.038 mm. Leak-rate measurements at all temperatures showed no detectable leak above the helium background level, typically 0.1 x 10(-9) std-cc/sec, during testing.

Salerno, Louis J.↗

Methodology to estimate vapor quality of refrigerant leaks

The US Department of Energy (DOE) Building Technology Office (BTO) and the Air-conditioning, Heating & Refrigeration Technology Institute (AHRTI) are sponsoring an experimental study of refrigerant leak characteristics. The objectives are to conduct refrigerant leak tests on several heating, ventilating, air conditioning and refrigeration (HVAC&R) systems under operating conditions representative of actual applications to document the pressure decay rate and the mass flow rate of leaked refrigerant as a function of time. Another aspect of the study was to formulate and document a procedure for estimating the quality (vapor versus liquid) of the leaking refrigerant and oil escaping from the high- and low-pressure sides with the unit energized and with the unit turned off. Refrigerant quality was estimated by tracking total system weight of a packaged air-conditioning (A/C) unit and the total weight of a large container used to capture the refrigerant leakage escaping the packaged unit.

Miller, William A.↗

Duct Leakage Repeatability Testing

The purpose of this report is to evaluate the repeatability of the three most significant measurement techniques for duct leakage using data from the literature and recently obtained field data. We will also briefly discuss the first two factors. The main question to be answered by this study is to determine if differences in the repeatability of these tests methods is sufficient to indicate that any of these methods is so poor that it should be excluded from consideration as an allowed procedure in codes and standards. The three duct leak measurement methods assessed in this report are the two duct pressurization methods that are commonly used by many practitioners and the DeltaQ technique. These are methods B, C and A, respectively of the ASTM E1554 standard. Although it would be useful to evaluate other duct leak test methods, this study focused on those test methods that are commonly used and are required in various test standards, such as BPI (2010), RESNET (2014), ASHRAE 62.2 (2013), California Title 24 (CEC 2012), DOE Weatherization and many other energy efficiency programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of flightweight static face seals for 75.84 MPa /11 000 psi/ pressure and cryogenic temperatures

The development of a static seal configuration to meet the lightweight low-leakage requirements of the Space Shuttle Main Engine (pressure carrying capability of up to 75.84 MPa) is discussed. The design features, fabrication methods, lab testing, and performance of seal are examined. Flange and bolt details of the joint assembly are considered with attention to an ultrasonic technique for measuring preload in the bolts. Methods used for leak testing in the laboratory and in the field are described; the practicality of the procedures is considered. Attention is directed to hydrogen-environment embrittlement and its influence on seal and joint design.

Daniels, C. M.↗

Design and Development of a Composite Dome for Experimental Characterization of Material Permeability

This paper presents the design and development of a carbon fiber reinforced plastic dome, including a description of the dome fabrication, method for sealing penetrations in the dome, and a summary of the planned test series. This dome will be used for the experimental permeability characterization and leakage validation of composite vessels pressurized using liquid hydrogen and liquid nitrogen at the Cryostat Test Facility at the NASA Marshall Space Flight Center (MSFC). The preliminary design of the dome was completed using membrane shell analysis. Due to the configuration of the test setup, the dome will experience some flexural stresses and stress concentrations in addition to membrane stresses. Also, a potential buckling condition exists for the dome due to external pressure during the leak testing of the cryostat facility lines. Thus, a finite element analysis was conducted to assess the overall strength and stability of the dome for each required test condition. Based on these results, additional plies of composite reinforcement material were applied to local regions on the dome to alleviate stress concentrations and limit deflections. The dome design includes a circular opening in the center for the installation of a polar boss, which introduces a geometric discontinuity that causes high stresses in the region near the hole. To attenuate these high stresses, a reinforcement system was designed using analytical and finite element analyses. The development of a low leakage polar boss system is also investigated.

Estrada, Hector↗

Fabrication Status of ITER Central Solenoid Modules

The fabrication of the modules for the ITER Central Solenoid (CS) is in progress at General Atomics (GA) in Poway, California, USA. This purpose built facility has been established with the requisite tools and machines to fabricate the seven 110 tonne CS modules (six required plus one spare). GA’s project responsibility is completing the fabrication design, developing and qualifying the fabrication processes and tools, fabricating the seven modules, and testing the modules at 4.5 K with full current. The current schedule has the first module’s completing fabrication in 2018 followed by electrical and full current testing. Upon completion of testing, the modules will be shipped to the ITER site for assembly into the CS stack. GA has co mpleted the fabrication of a qualification coil, simulating all of the processes and exercising all of the tooling required to fabricate a production module. After completion, the qualification coil underwent a cool down cycle to 4.5K which served as the final commissioning step of the helium cooling system on the parallel flow paths of a module. In addition, other final test station systems and procedures were simulated to verify their functionality including simulated critical current sharing temperature (Tcs) measurements, DC switch operation to dump the energy from the coil, and a helium leak test on the coil at <10K. After warming the coil, Paschen tests were repeated prior to the coil being dissected to evaluate the quality of the vacuum pressure impregnation (VPI). Dissection is scheduled for early spring 2018 and the results showed full resin impregnation of all areas. In the production and testing of the qualification coil, many lessons were learned and the improvements incorporated into the module fabrication processes. GA currently has five production modules in fabrication, at different stages in the process. The first module is nearly ready for vacuum pressure impregnation. The second and third modules are currently in the insulation process and the 7 pancakes of the forth module are being joined together into a 110 tonne module. Module 5 is currently being wound. The qualification coil has been completed and dissected to evaluate the VPI. A description of the VPI process is provided. To verify the turn insulation of a module, unique impulse testing methods were developed to test the insulation between the 560 turns of a module. These methods are reported in this paper.

Smith, J.↗

ANSYS Explicit Modeling for Prospective SAVY Designs and Worst Case Impact Orientation during Drop

A preliminary experimental drop test of a new 5.5 gallon SAVY-4000 container at a 12 ft height resulted in an impact angle of approximately 26 degrees and significant deformation of the locking ring and locking collar. Subsequently, the SAVY failed leak tests following the drop test. Based on previous analyses on SAVY containers, the primary modes of failure were determined to be vertical drops directly over the lid for the larger diameter sizes. The tests were initially bounded by the 45 degree impact angle. It was necessary to determine if a new bounding case existed at or near an impact angle of 26 degrees. In addition to characterizing the drop angle, modifications to the existing SAVY components were applied and analyzed to determine if container deformations could be minimized. Figure 1 includes the primary drop configurations investigated. A parametric study was conducted to determine the sensitivity of lid and collar deformation as a function of impact angle.

42 ENGINEERING↗

Small-Scale Spray Releases: Additional Aerosol Test Results

One of the events postulated in the hazard analysis at the Waste Treatment and Immobilization Plant (WTP) and other U.S. Department of Energy (DOE) nuclear facilities is a breach in process piping that produces aerosols with droplet sizes in the respirable range. The current approach for predicting the size and concentration of aerosols produced in a spray leak involves extrapolating from correlations reported in the literature. These correlations are based on results obtained from small engineered spray nozzles using pure liquids with Newtonian fluid behavior. The narrow ranges of physical properties on which the correlations are based do not cover the wide range of slurries and viscous materials that will be processed in the WTP and across processing facilities in the DOE complex. To expand the data set upon which the WTP accident and safety analyses were based, an aerosol spray leak testing program was conducted by Pacific Northwest National Laboratory (PNNL). PNNL’s test program addressed two key technical areas to improve the WTP methodology (Larson and Allen 2010). The first technical area was to quantify the role of slurry particles in small breaches where slurry particles may plug the hole and prevent high-pressure sprays. The results from an effort to address this first technical area can be found in Mahoney et al. (2012a). The second technical area was to determine aerosol droplet size distribution and total droplet volume from prototypic breaches and fluids, including sprays from larger breaches and sprays of slurries for which literature data are largely absent. To address the second technical area, the testing program collected aerosol generation data at two scales, commonly referred to as small-scale and large-scale. The small-scale testing and resultant data are described in Mahoney et al. (2012b) and the large-scale testing and resultant data are presented in Schonewill et al. (2012). In tests at both scales, simulants were used to mimic the relevant physical properties projected for actual WTP process streams.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analyses of Transistor Punchthrough Failures

The failure of two transistors in the Altitude Switch Assembly for the Solid Rocket Booster followed by two additional failures a year later presented a challenge to failure analysts. These devices had successfully worked for many years on numerous missions. There was no history of failures with this type of device. Extensive checks of the test procedures gave no indication for a source of the cause. The devices were manufactured more than twenty years ago and failure information on this lot date code was not readily available. External visual exam, radiography, PEID, and leak testing were performed with nominal results Electrical testing indicated nearly identical base-emitter and base-collector characteristics (both forward and reverse) with a low resistance short emitter to collector. These characteristics are indicative of a classic failure mechanism called punchthrough. In failure analysis punchthrough refers to an condition where a relatively low voltage pulse causes the device to conduct very hard producing localized areas of thermal runaway or "hot spots". At one or more of these hot spots, the excessive currents melt the silicon. Heavily doped emitter material diffuses through the base region to the collector forming a diffusion pipe shorting the emitter to base to collector. Upon cooling, an alloy junction forms between the pipe and the base region. Generally, the hot spot (punch-through site) is under the bond and no surface artifact is visible. The devices were delidded and the internal structures were examined microscopically. The gold emitter lead was melted on one device, but others had anomalies in the metallization around the in-tact emitter bonds. The SEM examination confirmed some anomalies to be cosmetic defects while other anomalies were artifacts of the punchthrough site. Subsequent to these analyses, the contractor determined that some irregular testing procedures occurred at the time of the failures heretofore unreported. These testing irregularities involved the use of a breakout box and were the likely cause of the failures. There was no evidence to suggest a generic failure mechanism was responsible for the failure of these transistors.

Nicolas, David P.↗

Metabolic Vessel for Impedance Spectroscopy and Electrochemistry (MVISE): The Ground Mapping Unit for the Lunar Explorer Instrument for Space Biology Applications (LEIA)​

The BioSensor payload on the upcoming LEIA platform aboard a CLPS lander will carry yeast to the moon to study response to radiation and lunar gravity. The LEIA BioSensor is designed to monitor metabolic activity using absorbance in conjunction with alamarBlue for measuring colorimetric changes as proxy measurement for redox potential. The science data returned from small spacecraft mission modules like LEIA is limited as it relies solely on optical measurements, necessitating a corresponding ground mapping unit that is equipped with multiple electrochemical sensors for accurate mapping of the optical data and operates fully automatically. This technology development work discusses the extensive design and optimization efforts put into the ground mapping unit, MVISE. MVISE is a custom designed, 3D-printed vessel with an agitation system, with six different electrochemical sensor probes, and ports for sample collection and a pressure release valve. The sensors provide real-time data, with dry absorbance measurements aligning with LEIA flight hardware and wet measurements demonstrating invasive sensor design enabling a comparison between the two setups. The 3D printer resin was tested for mechanical robustness, biocompatibility, and resistance to autoclave sterilization. The inner walls were coated with food-grade epoxy, ensuring a smooth finish to prevent microbial lodging and dye staining. The MVISE has successfully passed a week-long leak test and is now undergoing active biology tests. The MVISE prototype will be prepared for radiation tests, with three identical units being tested for varying radiation levels and culture compositions at the NASA Space Radiation Laboratory in November 2024. The integrated sensor approach proposed in this work will enable the accurate mapping of the BioSentinel/LEIA optical flight data to six sensor parameters on the ground unit for better science data return and will enable the first effort to evaluate classical biochemical sensor measurements by comparing and contrasting their responses.

Chinmayee Govinda Raj↗

Non-contact measurement of partial gas pressure and distribution of elemental composition using energy-resolved neutron imaging

Neutron resonance absorption imaging is a non-destructive technique that can characterize the elemental composition of a sample by measuring nuclear resonances in the spectrum of a transmitted beam. Recent developments in pixelated time-of-flight imaging detectors coupled with pulsed neutron sources pose new opportunities for energy-resolved imaging. In this paper we demonstrate non-contact measurements of the partial pressure of xenon and krypton gases encapsulated in a steel pipe while simultaneously passing the neutron beam through high-Z materials. The configuration was chosen as a proof of principle demonstration of the potential to make non-destructive measurement of gas composition in nuclear fuel rods. The pressure measured from neutron transmission spectra (~739 ± 98 kPa and ~751 ± 154 kPa for two Xe resonances) is in relatively good agreement with the pressure value of ~758 ± 21 kPa measured by a pressure gauge. This type of imaging has been performed previously for solids with a spatial resolution of ~ 100 μm. In the present study it is demonstrated that the high penetration capability of epithermal neutrons enables quantitative mapping of gases encapsulate within high-Z materials such as steel, tungsten, urania and others. This technique may be beneficial for the non-destructive testing of bulk composition of objects (such as spent nuclear fuel assemblies and others) containing various elements opaque to other more conventional imaging techniques. As a result, the ability to image the gaseous substances concealed within solid materials also allows non-destructive leak testing of various containers and ultimately measurement of gas partial pressures with sub-mm spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High energy density capacitors for vacuum operation with a pulsed plasma load

Results of the effort of designing, fabricating, and testing of a 40 joules/lb (88.2 joules/Kg) high voltage energy storage capacitor suitable for operating a pulsed plasma thruster in a vacuum environment for millions of pulses are presented. Using vacuum brazing and heli-arc welding techniques followed by vacuum and high pressure helium leak tests it was possible to produce a hermetically sealed relatively light weight enclosure for the dielectric system. An energy density of 40 joules/lb was realized with a KF-polyvinylidene fluoride dielectric system. One capacitor was D.C. life tested at 4 KV (107.8 joules/lb) for 2,000 hours before it failed. Another exceeded 2,670 hours without failure at 38.3 joules/lb. Pulse life testing in a vacuum exceeded 300,000 discharges with testing still in progress. The D.C. life test data shows a small decrease in capacitance and an increase in dissipation factor with time. Heat transfer from the load to the capacitor must also be considered besides the self-heat generated by the capacitor.

Guman, W. J.↗