Pulse Stripping Analysis: A Technique for Determination of Some Metals in Aerosols and Other Limited Size Samples

A technique for determining lead with a detection limit down to a nanogram on limited size samples is described. The technique is an electrochemical one and involves pre-concentration of the metal species in a mercury drop. Although the emphasis in this paper is on the determination of lead, many metal ion species which are reducible to the metal at an electrode are equally determinable. A technique called pulse polarography is proposed to determine the metals in the drop and this technique is discussed and is compared with other techniques. Other approaches for determination of lead are also compared. Some data are also reported for the lead content of Ventura County particulates. The characterization of lead species by solubility parameters is discussed.

Parry, Edward P.↗

Zinc Oxide–Graphene Nanocomposite-Based Sensor for the Electrochemical Determination of Cetirizine

A nanocomposite electrode of graphene (Gr) and zinc oxide (ZnO) nanoparticles was fabricated to study the electrochemical oxidation behavior of an anti-inflammatory drug, i.e., cetirizine (CET). The voltametric response of CET for bare CPE, Gr/CPE, ZnO/CPE, and the ZnO-Gr nanocomposite electrode was studied. The modifier materials were characterized using scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), and X-ray powder diffraction (XRD) to comprehend the surface morphology of the utilized modifiers. The influence of pH, scan rate, and accumulation time on the electrooxidation of CET was examined. It was found that the electrochemical oxidation of CET was diffusion-controlled, in which two protons and two electrons participated. The detection limit was found to be 2.8 × 10 -8 M in a linearity range of 0.05–4.0 µM. Study of excipients was also performed, and it was found that they had negligible interference with the peak potential of CET. The validation and utility of the fabricated nanocomposite sensor material were examined by analyzing clinical and biological samples. Stability testing of the nanocomposite electrode was conducted to assess the reproducibility, determining that the developed biosensor has good stability and high efficiency in producing reproducible results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

All-aerosol-jet-printed highly sensitive and selective polyaniline-based ammonia sensors: a route toward low-cost, low-power gas detection

In this work, we report the design and scalable fabrication of a low-cost and low-power polyaniline-based (PANI) ammonia (NH3) gas sensor on polyimide (PI) substrates using additive manufacturing techniques. The silver interdigitated electrode (IDE) arrays and conducting polymer films are printed onto PI using a direct-write technology of aerosol-jet printing. Morphological characteristics are examined by scanning electron microscopy and energy-dispersive X-ray analysis which reveal homogeneously printed PANI film on the IDE platform. The gas sensing performance is evaluated in the analytical early leak detection range of 5–1000 ppm NH3 in air as a function of both thermal (23 °C, 50 °C, 80 °C) and relative humidity (RH = 0%, 30%, 50%) exposures. The sensor exhibits sensitivity down to 5 ppm NH3 with a sub-ppm detection limit and good repeatability. We observe rapid NH3 detection at 0% RH with very extended times for equilibration and recovery. However, at both 30 and 50% RH, the room temperature response and recovery times are reduced to only about 1 min and 5 min, respectively. Experiments also reveal good sensitivity toward the analyte even at higher operating temperatures. Present results merit the practical application of aerosol-jet-printed, low-power sensors for industrial applications where low-level hazardous gas detection is essential.

36 MATERIALS SCIENCE↗

Copper-Based Two-Dimensional Conductive Metal–Organic Framework Thin Films for Ultrasensitive Detection of Perfluoroalkyls in Drinking Water

Perfluoroalkyls (PFAS) continue to emerge as a global health threat making their effective detection and capture extremely important. Though metal–organic frameworks (MOFs) have stood out as a promising class of porous materials for sensing PFAS, detection limits remain insufficient and a fundamental understanding of detection mechanisms warrants further investigation. Here, in this study, we show the use of a 2D conductive MOF film based on copper hexahydroxy triphenylene (Cu-HHTP) to fabricate chemiresistive sensing devices for detecting PFAS in drinking water. We further show ultrasensitive detection using electrochemical impedance spectroscopy. Owing to excellent electrostatic attractions and electrochemical interactions between the copper-based MOF and PFAS, confirmed by high-resolution spectroscopy and theoretical simulations, the MOF-based sensor reported herein exhibits excellent affinity and sensitivity toward perfluorinated acids at concentrations as low as 0.002 ng/L.

2D metal−organic frameworks↗

Measurements of Oxychlorine species on Mars

Mars landed and orbiter missions have instrumentation capable of detecting oxychlorine phases (e.g. perchlorate, chlorate) on the surface. Perchlorate (~0.6 wt%) was first detected by the Wet Chemistry Laboratory in the surface material at the Phoenix Mars Landing site. Subsequent analyses by the Thermal Evolved Gas Analyser aboard the same lander detected an oxygen release (~465°C) consistent with the thermal decomposition of perchlorate. Recent thermal analysis by the Mars Science Laboratory’s Sample Analysis at Mars instrument has also indicated the presence of oxychlorine phases (up to 1.2 wt%) in Gale Crater materials. Despite being at detectable concentrations, the Chemistry and Mineralogy (CheMin) X-ray diffractometer has not detected oxychlorine phases. This suggests that Gale Crater oxychlorine may exist as poorly crystalline phases or that perchlorate/chlorate mixtures exist, so that individual oxychlorine concentrations are below CheMin detection limits (~1 wt%). Although not initially designed to detect oxychlorine phases, reinterpretation of Viking Gas Chromatography/Mass Spectrometer data also suggest that oxychlorine phases are present in the Viking surface materials. Remote near-infrared spectral analyses by the Compact Reconnaissance Imaging Spectrometer for Mars (CRISM) instrument indicate that at least some martian recurring slope lineae (RSL) have spectral signatures consistent with the presence of hydrated perchlorates or chlorates during the seasons when RSL are most extensive. Despite the thermal emission spectrometer, Thermal Emission Imaging System, Observatoire pour la Minéralogie, l’Eau, les Glaces et l’Activité and CRISM detection of hundreds of anhydrous chloride (~10–25 vol%) deposits, expected associated oxychlorine phases (>5–10 vol%) have not been detected. Total Cl and oxychlorine data sets from the Phoenix Lander and the Mars Science Laboratory missions could be used to develop oxychlorine versus total Cl correlations, which may constrain oxychlorine concentrations at other locations on Mars by using total Cl determined by other missions (e.g. Viking, Pathfinder, MER and Odyssey). Development of microfluidic or ‘lab-on-a-chip’ instrumentation has the potential to be the next generation analytical capability used to identify and quantify individual oxychlorine species on future landed robotic missions to Mars.

Perchlorate↗

Simultaneous Planck, Swift, and Fermi Observations of X-ray and Gamma-ray Selected Blazars

We present simultaneous Planck, Swift, Fermi, and ground-based data for 105 blazars belonging to three samples with flux limits in the soft X-ray, hard X-ray, and gamma-ray bands, with additional 5 GHz flux-density limits to ensure a good probability of a Planck detection. We compare our results to those of a companion paper presenting simultaneous Planck and multi-frequency observations of 104 radio-loud northern active galactic nuclei selected at radio frequencies. While we confirm several previous results, our unique data set allows us to demonstrate that the selection method strongly influences the results, producing biases that cannot be ignored. Almost all the BL Lac objects have been detected by the Fermi Large Area Telescope (LAT), whereas 30% to 40% of the flat-spectrum radio quasars (FSRQs) in the radio, soft X-ray, and hard X-ray selected samples are still below the gamma-ray detection limit even after integrating 27 months of Fermi-LAT data. The radio to sub-millimetre spectral slope of blazars is quite flat, with (alpha) approx 0 up to about 70GHz, above which it steepens to (alpha) approx -0.65. The BL Lacs have significantly flatter spectra than FSRQs at higher frequencies. The distribution of the rest-frame synchrotron peak frequency (nu(sup s)(sub peak)) in the spectral energy distribution (SED) of FSRQs is the same in all the blazar samples with (nu(sup s)(sub peak)) = 10(exp 13.1 +/- 0.1) Hz, while the mean inverse Compton peak frequency, (nu(sup IC)(sub peak)), ranges from 10(exp 21) to 10(exp 22) Hz. The distributions of nu(sup s)(sub peak) and nu(sup IC)(sub peak) of BL Lacs are much broader and are shifted to higher energies than those of FSRQs; their shapes strongly depend on the selection method. The Compton dominance of blazars. defined as the ratio of the inverse Compton to synchrotron peak luminosities, ranges from less than 0.2 to nearly 100, with only FSRQs reaching values larger than about 3. Its distribution is broad and depends strongly on the selection method, with gamma-ray selected blazars peaking at approx 7 or more, and radio-selected blazars at values close to 1, thus implying that the common assumption that the blazar power budget is largely dominated by high-energy emission is a selection effect. A comparison of our multi-frequency data with theoretical predictions shows that simple homogeneous SSC models cannot explain the simultaneous SEDs of most of the gamma-ray detected blazars in all samples. The SED of the blazars that were not detected by Fermi~LAT may instead be consistent with SSC emission. Our data challenge the correlation between bolometric luminosity and nu(sup s)(sub peak) predicted by the blazar sequence.

Giommi, P.↗

Analysis of Defense Waste Processing Facility (DWPF) Condensate Samples and Evaluation of the Glycolate Destruction Process during Nitric-Glycolic flowsheet Transition

Glycolate concentrations were measured by the Savannah River National Laboratory (SRNL) in Slurry Mix Evaporator Condensate Tank (SMECT) and Recycle Collection Tank (RCT) samples retrieved after implementation of the Nitric-Glycolic Acid flowsheet at the Defense Waste Processing Facility (DWPF). No glycolate has been detected in any sample using Ion Chromatography (IC) with a detection limit of 8 mg/L, and no glycolate has been detected using either IC or Proton Nuclear Magnetic Resonance Spectroscopy ( 1 HNMR) after a permanganate strike was performed in the RCT.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Single Channel Infrasound Detection Using Machine Learning

Infrasound, low frequency sound less than 20 Hz, is generated by both natural and anthropogenic sources. Infrasound sensors measure pressure fluctuations only in the vertical plane and are single channel. However, the most robust infrasound signal detection methods rely on stations with multiple sensors (arrays), despite the fact that these are sparse. Automated methods developed for seismic data, such as short-term average to long-term average ratio (STA/LTA), often have a high false alarm rate when applied to infrasound data. Leveraging single channel infrasound stations has the potential to decrease signal detection limits, though this cannot be done without a reliable detection method. Therefore, this report presents initial results using (1) a convolutional neural network (CNN) to detect infrasound signals and (2) unsupervised learning to gain insight into source type.

47 OTHER INSTRUMENTATION↗

Radio survey of Markarian galaxies at 6 and 11 cm

One hundred and fifty-one objects from Markarian's lists 6 and 7 were observed at 6 cm with a 3 sigma detection limit of about 30 mJy. Eight Markarian objects were detected, six of which were also observed at 11 cm. Forty-five others were negative at this wavelength. Two of the detections, numbers 533 and 668, are Seyfert galaxies; additionally, UB1 was detected at 6 cm and NGC 7715 and III Zw 2 were found at 11 cm.

Kojoian, G.↗

Hydrazine monitoring in spacecraft

Hydrazine (HZ) and monomethyl hydrazine (MMH) are highly toxic compounds used as fuels in the Space Shuttle Orbiter Main Engines and in its maneuvering and reaction control system. Satellite refueling during a mission may also result in release of hydrazines. During extravehicular activities, the potential exists for hydrazines to contaminate the suit and to be brought into the internal atmosphere inadvertantly. Because of the high toxicity of hydrazines, a very sensitive, reliable, interference-free, and real-time method of measurement is required. A portable ion mobility spectrometer (IMS) has exhibited a low ppb detection limit for hydrazines suggesting a promising technology for the detection of hydrazines in spacecraft air. The Hydrazine Monitor is a modified airborne vapor monitor (AVM) with a custom-built datalogger. This off-the-shelf IMS was developed for the detection of chemical warfare agents on the battlefield. After early evaluations of the AVM for hydrazine measurements showed a serious interference from ammonia, the AVM was modified to measure HZ and MMH in the ppb concentration range without interference from ammonia in the low ppm range. A description of the Hydrazine Monitor and how it functions is presented.

Cross, J. H.↗

Unmanned Aircraft Systems (UAS) Integration in the National Airspace System (NAS) Project

Phase 1 of the UAS-NAS (Unmanned Aircraft Systems-National Airspace System) project focused on MOPS (Minimum Operational Performance Standards) development for large UAS transitioning through Class D, E, and G airspace. Phase 2 activities are currently focused on extended UAS operations in Class D, E, and G airspace, as well as sensors and architectures that will enable DAA (Detect and Avoid) equipment to be installed on a wider range of UAS. Encounters with non-cooperative intruders in low altitude airspace under 10,000 feet will be explored for UAS with a low Size, Weight, and Power (SWaP) radar. New sensors for detecting non-cooperative intruder aircraft will have a more limited detection range and field of regard; therefore, the analysis of non-cooperative encounter geometries may help in developing the requirements for an onboard low SWaP radar (and electro-optical sensor). The current simulation, led by HSI (Human Systems Integration Division at NASA Ames Research Center) as part of the DAA subproject, will support efforts toward developing a modified DAA Well Clear (DWC) definition that would be more appropriate for UAS equipped with limited surveillance and aircraft performance capabilities compared to the Phase 1 DAA system. The findings will inform Phase 2 display requirements for alternative surveillance use cases.

Collision Avoidance↗

Remote sensing of OH in the atmosphere using the technique of laser-induced fluorescence

The use of a laser-induced fluorescence technique for the sensitive measurement of the atmospheric hydroxyl radical is discussed. Results of laboratory studies of the fluorescence and other spectroscopic properties of OH which allow the calculation of OH concentrations from the returned signals for various altitudes, water vapor contents and temperatures are presented. The experimental setup used for airborne OH measurements is then described, with particular attention given to the use of a telescope for excitation and light collection in a coaxial configuration and the periodic tuning of the exciting radiation necessary to obtain an OH signal in the presence of strong solar and nonresonant fluorescence backgrounds. The best detection limit obtained to date with the system is noted to be about 700,000 OH/cu cm, and it is expected that, with planned improvements in detection and tuning schemes, limits in the neighborhood of 1,000,000 OH/cu cm will be achieved routinely.

Wang, C. C.↗

On the possibility of baryon acoustic oscillation measurements at redshift z > 7.6 with the Roman space telescope

ABSTRACT The Nancy Grace Roman Space Telescope (RST), with its field of view and high sensitivity will make surveys of cosmological large-scale structure possible at high redshifts. We investigate the possibility of detecting baryon acoustic oscillations (BAO) at redshifts z > 7.6 for use as a standard ruler. We use data from the hydrodynamic simulation bluetides in conjunction with the gigaparsec-scale Outer Rim simulation and a model for patchy reionization to create mock RST High Latitude Survey grism data for Lyman α emission line selected galaxies at redshifts z = 7.4 to z = 10, covering 2280 deg2. We measure the monopoles of galaxies in the mock catalogues and fit the BAO features. We find that for a line flux of $L = 7\times 10^{-17} \ {\rm erg\, s^{-1}\, cm}^{-2}$, the 5σ detection limit for the current design, the BAO feature is partially detectable (measured in three out of four survey quadrants analysed independently). The resulting root mean square error on the angular diameter distance to z = 7.7 is 7.9 ${{\ \rm per\ cent}}$. If we improve the detection sensitivity by a factor of two (i.e. $L = 3.5\times 10^{-17} \ {\rm erg\, s^{-1}\, cm}^{-2}$), the distance error reduces to $1.4{{\ \rm per\ cent}}$. We caution that many more factors are yet to be modelled, including dust obscuration, the damping wing due to the intergalactic medium, and low redshift interlopers. If these issues do not strongly affect the results, or different observational techniques (such as use of multiple lines) can mitigate them, RST, or similar instruments may be able to constrain the angular diameter distance to the high redshift universe.

79 ASTRONOMY AND ASTROPHYSICS↗

Site Alteration Effects from Rocket Exhaust Impingement During a Simulated Viking Mars Landing. Part 2: Chemical and Biological Site Alteration

Chemical and biological alteration of a Mars landing site was investigated experimentally and analytically. The experimental testing was conducted using a specially designed multiple nozzle configuration consisting of 18 small bell nozzles. The chemical test results indicate that an engine using standard hydrazine fuel will contaminate the landing site with ammonia (50-500ppm), nitrogen (5-50ppm), aniline (0.01-0.5ppm), hydrogen cyanide (0.01-0.5ppm), and water. A purified fuel, with impurities (mostly aniline) reduced by a factor of 50-100, limits the amount of hydrogen cyanide and aniline to below detectable limits for the Viking science investigations and leaves the amounts of ammonia, nitrogen, and water in the soil unchanged. The large amounts of ammonia trapped in the soil will make interpretation of the organic analysis investigation results more difficult. The biological tests indicate that the combined effects of plume gases, surface heating, surface erosion, and gas composition resulting from the retrorockets will not interfere with the Viking biology investigation.

Husted, R. R.↗

Trace element analyses of spheres from the melt zone of the Greenland ice cap using synchrotron X ray fluorescence

Synchrotron X-ray fluorescence spectra of unpolished iron and chondritic spheres extracted from sediments collected on the melt zone of the Greenland ice cap allow the analysis of Ni, Cu, Zn, Ga, Ge, Pb, and Se with minimum detection limits on the order of several parts per million. All detected elements are depleted relative to chondritic abundance with the exception of Pb, which shows enrichments up to a factor of 500. An apparent anticorrelation between the Ni-content and trace element concentration was observed in both types of spherules. The fractionation patterns of the iron and chondritic spheres are not complementary and consequently the two iron spheres examined in this study are unlikely to result from ejection of globules of Fe/Ni from parent chondritic micrometeoroids.

Chevallier, P.↗

Evaluation of liquid water measuring instruments in cold clouds sampled during FIRE

Airborne liquid water content (LWC) measurements were conducted with an icing detector and a forward-scattering spectrometer probe during 10 flights into cold clouds, as part of the First ISCCP Research Experiment (FIRE). The LWC measurements thus obtained compare favorably with those from the hot-wire probes in the range where LWC is above the detection limits of the latter; the hot-wire probes have detection thresholds about one order of magnitude higher than is possible with the icing detector and spectrometer probe. FIRE experiment data indicate that LWC should be taken into consideration in cloud studies at temperatures down to at least 35 C.

Heymsfield, Andrew J.↗

Compact Multi-Channel Infrared Laser Absorption Spectrometer for Spacecraft Fire Safety Monitoring

We report on the design of a six-channel tunable laser absorption spectroscopy instrument for measuring ambient gas-phase concentrations of CO, HCl, HCN, HF, CO2, and O2 in spacecraft environments. Monitoring of these compounds can provide early warning detection of fire events while also indicating what materials have been exposed to heating. Continued post-fire monitoring of these hazardous gases can also facilitate safe and effective cleanup. The sensor is a miniaturized version of a five-channel prototype that was previously validated in ground-based oxidative pyrolysis tests. Here, we describe absorption line selection and theoretical detection limits for a sensor with reduced absorption pathlengths for each detection channel, which allows for a substantial reduction in overall instrument footprint. Ultimately, the new instrument is designed to be used in fire safety tests conducted by NASA, where various materials will undergo oxidative pyrolysis in an unmanned spacecraft returning from low Earth orbit.

Briggs, Ryan M.↗

Tea ( Camellia sinensis ) Extract-Mediated Green Synthesis of Co 3 O 4 and Co 3 O 4 @Graphene Nanocomposites for Multifunctional Applications in Pollutant Degradation, Sensing, and Energy Storage

A novel solution-mixing method was proposed to synthesize Co 3 O 4 /graphene nanocomposites (Co 3 O 4 @Gr) using a green tea leaf (Camellia sinensis) extract as the reducing agent. XRD analysis shows that the as-prepared Co 3 O 4 @Gr exhibits a cubic spinel crystal structure. From morphological analysis, the obtained Co 3 O 4 NS forms spherical clusters that are uniformly distributed on the graphene surface. FT-IR and Raman analyses confirmed the strong molecular and vibrational interactions between the Co 3 O 4 NS and Gr. The suppressed PL intensity peak of the Co 3 O 4 @Gr NCs indicated significant inhibition in the recombination of charge carriers between the hybrid orbitals within the composites. As a result, the catalytic efficiency of Co 3 O 4 @Gr NCs increased to 80% compared to pristine Co 3 O 4 , which exhibited only 45% efficiency against methylene blue (MB) dye. Moreover, the as-prepared NCs exhibited a detection limit of 0.01−224 μM, demonstrating a superior low-DPA detection with high sensitivity. The Co 3 O 4 @Gr/GCE exhibits admirable selectivity for various pesticides, fungicides, and metal ions, with outstanding reproducibility and stability. From electrochemical investigations, the highest specific capacitance values of the as-synthesized Co 3 O 4 @Gr were 349 F/g at a scan rate of 5 mV/s and 158 F/g at a current density of 1 A/g.

Capacitors↗