Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enhancing power grid resilience to winter storms via generator winterization with equity considerations

Here we develop two-stage stochastic programming models for generator winterization that enhance power grid resilience while incorporating social equity. The first stage in our models captures the investment decisions for generator winterization, and the second stage captures the operation of a degraded power grid, with the objective of minimizing load shed and social inequity. To incorporate equity into our models, we propose a concept called adverse effect probability that captures the disproportionate effects of power outages on communities with varying vulnerability levels. Grid operations are modeled using DC power flow, and equity is captured through mean or maximum adverse effects experienced by communities. We apply our models to a synthetic Texas power grid, using winter storm scenarios created from the generator outage data from the 2021 Texas winter storm. Our extensive numerical experiments show that more equitable outcomes, in the sense of reducing adverse effects experienced by vulnerable communities during power outages, are achievable with no impact on total load shed through investing in winterization of generators in different locations and capacities.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design and Fabrication of a Thyristor Using Ion Implantation of Anode and Cathode

A thyristor is a solid-state semiconductor switch made up of four alternating p and n type layers. When the switch is turned on by a small pulse, current can flow as long as the device stays on. When the voltage drops below the turn on level or the current reverses, the switch will turn off. Thyristors only allow current to flow in one direction. One of the benefits of a thyristor device is in its capacity to conduct large voltages with a small device and a small turn-on pulse requirement. Another distinguishing feature of thyristors compared to other semiconductor devices is that it can only be in the on or off state, there’s no in-between state for the device to exist within. These properties make thyristors very useful as switch devices, especially in applications where current flow is only needed in one direction and could potentially be damaging in the opposite direction. Currently, thyristors are most commonly used to control very high power loads and they are available commercially in many designs to control different amounts of current.

42 ENGINEERING↗

A Solution Method for the Filtered Lifting Line Theory

The filtered lifting line theory presents a continuous form of the inviscid momentum equations of flow over a lifting device, such as a wing or rotor blade, using body forces without mathematical singularities. This theory is also consistent with an actuator line representation of a lifting device. In this work, we present a reformulation of the equations in terms of the local flow angle along the line, which allows solving the stand-alone equations using multivariate root-finding algorithms. This approach can be used to obtain a fast, computationally inexpensive solution of the loading distribution along a wing without the need to perform computational fluid dynamic simulations. We study the requirements in terms of resolution in the spanwise direction and establish the criteria for spacing and minimum amount of points required along the blade to obtain converged solutions. The solutions are compared to results from large-eddy simulations, and we observed excellent agreement with less than a percent difference in quantities along the blade between the methods.

17 WIND ENERGY↗

Understanding the impact of an applied axial magnetic field on efficient current coupling on the Z machine

Magnetized liner inertial fusion (MagLIF) is an attractive concept for producing thermonuclear fusion reactions. The MagLIF platform involves the operation of Helmholtz coils to apply a 15 Tesla axial magnetic field to the load region, where a cylindrical, fuel-filled metal liner is imploded by a ∼ 2 0 MA current pulse. The fringe field from these coils extends into the transmission line that delivers the current to the target. We investigated the extent to which this applied field disturbs the nominal power flow within that transmission line. A simplified model of the geometry shows that adding the applied magnetic field results in magnetic field lines that connect the cathode to the anode, suggesting electrons may not be magnetically insulated in this region. Particle-in-cell simulations indicated the addition of the applied magnetic field would not significantly impact the current delivery to the load. Velocimetry was used to experimentally assess the current delivery with and without the applied magnetic field. We find no measurable effects of the applied field on current delivery in the configuration investigated in this study. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A real-time distributed solid oxide electrolysis cell (SOEC) model for cyber-physical simulation

System integration and dynamic operability between SOEC and balance-of-plant (BoP) components are major technical challenges before realizing rapid load following of SOEC systems. Cyber-physical simulation (CPS) is a leading-edge digital engineering approach and is regarded as the next step beyond Digital Twins. CPS approach can be used to research SOEC system integration and develop dynamic controls prior to actual pilot testing without using a real SOEC. To seamlessly couple with BoP hardware and access non-observable operational parameters (e.g., local temperature gradient) during transients, a distributed one-dimensional (1D) real-time SOEC model was developed. Its real-time execution was demonstrated for 20 to 640 nodes at the fixed time step of 5 ms. A higher excess air ratio enabled smaller local temperature gradients on SOEC solid materials and faster transients upon current density step change from 0.15 to 0.55 A cm -2 . During the transients, the magnitude of the peak temperature gradient nearly doubled in 10 s from -3.5 to -5.9 °C cm -1 . This represents a significant operating risk that can impact the dynamic operability of SOEC systems. In addition, the local temperature gradient was found to change directions on all nodes in SOEC solid materials, with the greatest impact on the upstream nodes. The SOEC model was also tested at the thermal neutral voltage using actual process air flow parameters as variable model inputs. Variable process air temperatures were found to induce alternating local temperature gradients on SOEC solid materials. These are new operational mechanisms for SOEC degradation relevant for load following operational modes yet distinct from previous reports. To mitigate these unfavorable features, the SOEC can be operated at voltages that are slightly (±20 mV) deviated from the thermal neutral voltage. Here, the corresponding net thermal energy change was less than 1.6% of the electric power consumption. This 1D real-time SOEC model established the basis of cyber-physical simulation of SOEC hybrid systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Global heliospheric termination shock strength in the solar–interstellar interaction

A heliospheric termination shock (HTS) surrounds our Solar System at approximately 100 astronomical units from the Sun, where the expanding solar wind (SW) is compressed and heated before encountering the interstellar medium. HTS-accelerated particles govern the pressure balance with the interstellar medium, but little is known about the global properties of the HTS beyond in situ measurements from Voyager in only two directions of the sky. Here we fill this gap by extracting the HTS strength using particle-in-cell, test particle and magnetohydrodynamic simulations, constrained by Interstellar Boundary Explorer observations of energetic neutral atoms produced from HTS-accelerated particles. Our results reveal there is a higher compression near the poles during solar minimum compared with solar maximum due to the higher Mach number flow. North–south asymmetries arise from the disparate evolution of the polar coronal holes, while minimum compression near the flanks is probably due to SW slowing from mass loading over a greater distance to the HTS. The results imply a strong connection between the HTS strength and the SW and interstellar medium dynamics.

Astrophysical plasmas↗

Supporting ARPA-E Power Grid Optimization (Final Report)

Pacific Northwest National Laboratory (PNNL), Arizona State University (ASU), Georgia Institute of Technology (Georgia Tech), Los Alamos National Laboratory (LANL), National Renewable Energy Laboratory (NREL), Texas A&M University (TAMU), The University of Texas at Austin (UT), and the University of Wisconsin-Madison (UW-M) supported the ARPA-E Grid Optimization (GO) Competition by providing a common problem formulation, data format, datasets, evaluation mechanism, scoring, rules, and results that resulted in the awarding of $\$9.24$ million dollars to teams from academia, industry, and national labs for solving three sets of increasingly difficult non-linear, security- constrained AC Optimal Powerflow (AC-OPF) optimization problems in order to increase the efficiency of the US Electric Grid. It is estimated that a 1% increase in efficiency can save $\$1$ billion. Current industry practices typically use a linear DC model (DC-OPF) in order solve the OPF problem within the time constraints of the operation schedule. The GO Competition challenges the best power engineers, mathematicians, and computer scientists to make possible operational decisions based on accurate physical models. To accomplish this, the GO Competition created a series of Challenges and funded teams to produce the best solver. Challenge 1 was to solve the security constrained Alternating Current Optimal Power Flow (ACOPF) problem. Challenge 2 extended that to by adding adjustable transformer tap ratios, phase shifting transformers, switchable shunts, price-responsive demand, ramp rate constrained generators and loads, and fast-start unit commitment (UC). Furthermore, Challenge 2 was a maximization problem while Challenge 1 was a minimization problem. While Challenge 3 was being developed, the entrants were invited to find better solutions to the Challenge 2 synthetic datasets with no restrictions on time, hardware, or algorithms. The Challenge 2 solutions turned out to be very good. Challenge 3 expanded the Challenge 2 problem further by using multiperiod dynamic markets, including advisory models for extreme weather events, day-ahead markets, and the real-time markets with an extended look-ahead. These problems included active bid-in demand and topology optimization. Together the Challenges used nearly 30 million CPU hours. Since each team was working on the same problem, using the same data, and running on the same hardware, fair comparisons could be drawn as to the best solver. The datasets were varied enough, however, that the best solver for one dataset was not necessarily the best at another, so cumulative scores were used. The process was managed by the PNNL maintained website https://GOCompetition.energy.gov, where Entrants could find information about the problem, the data, the rules, submit their solver for evaluation, and see the scores of all the competing teams on a Leaderboard. Interest was world-wide but only American teams were eligible for prizes. The Competition has produced 34 journal articles 115 papers and been cited over 500 times in the literature, including 12 dissertations (4 from foreign countries; Columbia (2), Germany, and Italy) and 3 from the DOE ExaScale project. Software developed by Pearl Street Technologies for Challenges 1 and 2 is now deployed by Southwest Power Pool (SPP) and Midcontinent Independent Service Operator (MISO). Other teams have received inquiries from venture capitalists. Google DeepMind has thanked the Competition for making the datasets developed for the Competition public. They are using it to train machine learning models. The larger datasets have billions of unknowns to be solved for, but only a small percent matter in the final solution. Knowing what unknowns are important can dramatically speedup the solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Groundwater flowpath characteristics drive variability in per- and polyfluoroalkyl substances (PFAS) loading across a stream-wetland system

Groundwater dependent ecosystems in areas with industrial and military land use are at risk of direct exposure to a wide range of contaminants, including PFAS chemicals. Glaciated terrain often has mixed high and low permeability sediments coupled with groundwater flow-through lake features. These hydrogeologic attributes create highly complex ‘source to seep’ dynamics that make spatiotemporal contaminant transport patterns difficult to predict. We investigated one such system in detail using a suite of heat-tracing and chemical methods. Numerous (n=57) preferential groundwater discharge zones (vertical flux rates ranging 0.2 to 3.2 m/d) were identified across the upper Quashnet River stream-wetland system in Mashpee, MA, USA, adjacent to an Air Force Base with several known PFAS source areas. Surface-water and groundwater samples were collected and analyzed (n=145) for precursors and terminal PFAS compounds between March and September 2022. Samples were collected at identified seeps along the Quashnet River (n=59), from wells upgradient from the stream-wetland system (n= 44), from contributing flow-through kettle lakes (n=8), and at multiple locations along the Quashnet River (n=34). Samples from seeps and wells had measured PFAS concentrations ranging from non-detect to approximate 3,500 ng/L (mean= 1,650 ng/L), and a range of deuterium excess values (3.2 to 15.9 per mil) indicative of varying degrees of groundwater-lake interaction prior to emergence at the discharge zones. Groundwater-lake interaction along flowpaths that sourced the sampled seeps was farther supported by significant correlations (p < 0.01) between deuterium excess and %PFAS precursors, and between %PFAS precursors and multiple terminal PFAS compounds (e.g., PFPeS, PFBS, PFHxS). However, some sampled seeps contributing groundwater to the stream-wetland system had much higher total PFAS concentrations (>1000 ng/L) than the upgradient kettle lakes, despite showing lake (evaporative) isotopic signatures, indicating the potential for groundwater flowpath convergence at wetland discharge zones and the influence of lakebed PFAS precursor reactions. PFAS compounds and water isotopic composition at sampled multilevel groundwater wells, rivers, lakes, and seeps suggest that a complex mixture of source groundwater and flowpath characteristics are responsible for diverse observed PFAS mixtures at preferential discharge zones across the stream-wetland system. Further, total PFAS loading patterns to the Quashnet River via groundwater discharge remained remarkably similar from winter to summer to fall conditions, despite a regional dry period in late summer 2022 with the upper river channel completely drying. This work addresses gaps in the existing PFAS literature by demonstrating the importance of subsurface fate and transport on PFAS compound concentrations in controlling contaminant mass loading in preferential groundwater discharge zones and presents a transferrable field toolkit for efficient characterization of spatially preferential PFAS transport dynamics.

Contaminant transport↗

Thermo-hydraulic steam pipe models for district heating simulations: Simplifications to balance accuracy and simulation speed

Steam piping networks are essential for optimizing performance in industrial processes and district heating systems. However, dynamic models that balance thermo-hydraulic accuracy with computational efficiency remain limited. In response, this paper presents a new discretized steam pipe model based on the plug flow approach, capturing key thermo-hydraulic behaviors while simplifying steam phase change processes. Implemented in Modelica, the model accurately calculates temperature and pressure distributions along steam pipelines. To improve computational efficiency for district-scale simulations, five model simplifications are introduced: lumped thermo-hydraulic functions, empirical correlations, fluid state approximations, steady-state dynamics and inclusion of flow derivatives. These simplified models achieve 85%-98% accuracy in predicting pressure drop and condensation losses, including dynamic condensate behavior during pipe warm-up—a factor often overlooked in existing models. The models support diverse network configurations, scaling effectively to systems with multiple distribution pipes and connected building loads. Discrete models provide detailed insights but exhibit a cubic increase in simulation time as the network scales by N connected building O(N 2.42 ). In contrast, lumped models simulate 10–28 times faster than discrete, offering quadratic scaling of simulation time O(N 1.73 ). However, they still require 6 times more computation time than a lossless network, highlighting the inherent computational challenges of modeling compressible fluid flow. In conclusion, the steady-state lumped variant, with its near-linear scalability in computational time O(N 1.01 ), emerges as an efficient solution for preliminary design evaluations and extensive parametric studies.

15 GEOTHERMAL ENERGY↗

Closed-Loop Wind Turbine Controllers for Active Wake Mixing Strategies

Wind turbine active wake mixing (AWM) is an exciting new field of research where dynamic actuation, usually on the blade pitch angles, is used to increase wind farm-wide power production. From a controls perspective, the current state-of-the-art AWM strategies are very simple: a dynamic, usually periodic, reference signal is prescribed to actuators in an open-loop (OL) fashion. The actuation is then presumed to have a certain desired effect on the system, i.e., the wind turbine and the flow it affects. However, this system is highly nonlinear and experiences disturbances in the form of wind variations that are not known a priori. As a result, the OL approach might not yield optimal results. In this article, a novel approach is presented, which closes the loop on AWM controllers. A feedback loop is implemented, which uses measurements of the individual blade bending moments that are widely available on modern wind turbines to determine the individual blade pitch angles. A proof of concept of this implementation is presented in this article, and a thorough comparison with the OL method is executed using high-fidelity flow simulations. These simulations show that the novel closed-loop controller does not substantially increase wake mixing but achieves similar performance as the OL controller while reducing fatigue loads on the controlled turbine.

17 WIND ENERGY↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Engineering Assembly Kinetics and Line Roughness in Solvent Vapor-Annealed Block Copolymer/Homopolymer Blends

Block copolymer (BCP) directed self-assembly (DSA) is a promising route to enhance lithography resolution by multiplying nanopattern density and reducing feature roughness. Eliminating kinetically trapped self-assembly defects requires fast self-assembly. However, acceleration strategies like solvent vapor annealing or homopolymer blending broaden domain interfaces, implying a trade-off in increased feature roughness. In this work, we experimentally investigate this apparent dilemma between self-assembly kinetics and line roughness for solvent vapor-annealed thin films of a lamellar poly(styrene-block-2-vinylpyridine) (PS-b-P2VP) BCP blended with PS and P2VP homopolymers. Binary blends with PS or P2VP homopolymers and ternary blends incorporating both in equal weight fractions were solvent vapor annealed using acetone, a near-neutral solvent for PS and P2VP, followed by P2VP-selective vapor-phase infiltration with alumina (AlOx) and polymer etching. Binary blends with P2VP exhibit a modest kinetic enhancement but also higher line-edge and -width roughness due to the increased frequency of P2VP protrusions and bridge defects in the alumina line patterns. In contrast, binary blends with PS self-assemble noticeably faster, while domain asymmetry from the added PS homopolymer reduces roughness by curbing the number of alumina protrusions and bridge defects. Ternary blends maintain DSA line patterns across a wider composition window and, at higher homopolymer loadings, reduce roughness at length scales near the lamellar period, consistent with a reduced impact of intradomain compositional fluctuations. These findings provide important insights for codesigning blend compositions and process flows to achieve high-resolution, defect free patterns with minimal roughness through BCP DSA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of an Optimal Variable-Pitch Controller for Floating Axial-Flow Marine Hydrokinetic Turbines: Preprint

This article discusses the development of an optimal variable-pitch controller for floating, axial-flow marine turbines. Recently, OpenFAST, an open-source wind turbine modeling tool, has been extended to model marine turbines. A controller is necessary to simulate marine turbines for different load cases using OpenFAST, which greatly impacts the performance of the energy system. Previous studies have designed controllers using a linearized model of the marine turbine, which can be timeconsuming and require the expertise of a control engineer. In this study, we use an automated approach that uses generic models of the marine turbine to identify the controller gains, which can expedite the process of designing a controller. Using an optimizer to identify the control system parameters can additionally improve the controller's performance. The optimal controller tuned using such an approach results in a 20% reduction in the towerbase damage equivalent loading and better tracking of the rated generator speed and power.

closed-loop control↗

Assembly Bowing Reactivity Calculation Methodology Applied to Lead Fast Reactor

Ducted assemblies bow during operation due to power and temperature gradients which can be influenced by operating flow rates. For fast spectrum cores using ducted assemblies, the bowing behavior follows that of the duct and because there are gaps between the ducts, the bowing can result in compaction or expansion of the active core. This local displacement can have a positive or negative impact and knowing the net effect during transients is important for system reactivity control. Keeping the net bowing reactivity worth low is possible with attentive placement of load pads above the active core and selecting load pad gap thicknesses that result in a desired behavior at standard operating conditions. This paper considers a Lead Fast Reactor (LFR) concept fueled by HALEU UO2 developed by Westinghouse Electric Company (WEC) and applies a workflow of Argonne-developed codes to estimate the core bowing reactivity worth. Using orifice flow rates grouped by assembly type, the net reactivity impact due to core assembly bowing for the LFR was found to be small and in line with other liquid metal fast reactors: +29/+32/+35 pcm, or about +$0.049/+$0.055/+$0.059, for BOEC/MOEC/EOEC, respectively.

bowing reactivity↗

Distribution System Blackstart and Restoration Using DERs and Dynamically Formed Microgrids

Extreme weather events have led to long-duration outages in the distribution system (DS), necessitating novel approaches to blackstart and restore the system. Existing blackstart solutions utilize blackstart units to establish multiple microgrids (MGs), sequentially energize non-blackstart units, and restore loads. However, these approaches often result in isolated MGs. In DERs-aided blackstart, the continuous operation of these MGs is limited by the finite energy capacity of commonly used blackstart units like battery energy storage (BES)-based gridforming inverters (GFMIs). To address this issue, this article proposes a holistic blackstart and restoration framework that incorporates synchronization between dynamic MGs and the entire DS with the transmission grid (TG). To support synchronization, we leveraged virtual synchronous generator-based control for GFMIs to estimate their frequency response to load pick-up events using only initial/final quasi-steady-state points. Subsequently, a synchronization switching condition is developed to model synchronizing switches, aligning them seamlessly with a linearized branch flow problem. Finally, we designed a bottomup blackstart and restoration framework that considers the switching structure of the DS, energizing/synchronizing switches, DERs with grid-following inverters, and BES-based GFMIs with frequency security constraints. In conclusion, the proposed framework is validated in IEEE-123-bus system, considering cases with two and four GFMIs under various TG recovery instants.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Elucidating lipid nanoparticle properties and structure through biophysical analyses

Designing lipid nanoparticle (LNP) delivery systems with specific targeting, potency and minimal side effects is crucial for their clinical use. However, traditional characterization methods, such as dynamic light scattering, cannot accurately quantify physicochemical properties of LNPs and how these are influenced by the lipid composition and mixing method. Here, we structurally characterize polydisperse LNP formulations by applying emerging solution-based biophysical methods that have higher resolution and provide biophysical data beyond size and polydispersity. These techniques include sedimentation velocity analytical ultracentrifugation, field-flow fractionation followed by multiangle light scattering and size-exclusion chromatography in line with synchrotron small-angle X-ray scattering. Here, we show that LNPs have intrinsic polydispersity in size, RNA loading and shape, which depend on both the formulation technique and the lipid composition. Lastly, we predict LNP transfection in vitro and in vivo by examining the relationship between mRNA translation and physicochemical characteristics. Solution-based biophysical methods will be essential for determining LNP structure–function relationships, facilitating the creation of new design rules for LNPs.

36 MATERIALS SCIENCE↗

Benchmark of numerical modeling approaches on the systematic performance evaluation of wave energy converters

Different numerical modeling methods have been developed and applied to evaluate a variety of performance indicators of wave energy converters (WECs), including the power performance, structural loads, levelized cost of energy, etc. Based on the modeling fidelity, the commonly used numerical modeling approaches can be classified as linear modeling, weakly nonlinear modeling and fully nonlinear modeling approaches. Each method differs in accuracy and computational efficiency, making them suitable for different stages of WEC design. However, the selection of modeling approach could significantly impact evaluation outcomes. For instance, simplified linear models may underestimate structural loads or overestimate energy production in some operational conditions, potentially leading to less cost-effective designs. Given the widespread utilization of these models, it is essential to understand the uncertainties brought by them in performance evaluations. This work is dedicated to benchmarking different linear-potential-flow-based numerical models for evaluating the systematic performance of WECs. Three representative numerical modeling approaches are considered in this work, including linear frequency-domain modeling, statistically linearized spectral-domain modeling and Cummins equation-based nonlinear time-domain modeling. A generic point absorber WEC is considered as the research reference in this work, and different sea sites are taken into account. The numerical models are utilized to predict critical performance indicators, including power performance, the annual energy production, the capacity factor, the levelized cost of energy and the PTO fatigue loads. By comparing the results, this work identifies the uncertainties associated with different modeling approaches in evaluating WEC performance.

Fatigue↗