At least 163 records · Page 9

Effects of Long-Duration Microgravity on Fine Motor Skills: ISS One-Year Mission

Fine motor skills will be critical in future long-duration missions, particularly those skills needed to interact with advanced technologies in next-generation vehicles, spacesuits, and habitats. Studies to date on the effects of microgravity and gravitational transitions on fine motor performance have not yielded conclusive results. Datasets are incomplete-timeline gaps in the microgravity data sessions. Studies have not focused on the fine motor actions that are likely to be required for interacting with software displays and controls (pointing, clicking, dragging, multi-touch/pinching). The majority of studies have used a joystick or arm reaching task. Touchscreen tablets are already in use on ISS, and at least one commercial partner is already planning a cockpit with touchscreens as the primary means of input. We must ensure that crewmembers are ready to perform with computer-based devices after a long-duration voyage and transition to surface operations.

Kritina Holden↗

Long Duration Exposure Facility (LDEF) space environments overview

The Long Duration Exposure Facility (LDEF) was retrieved from Earth orbit in January 1990 after spending almost six years in space. It had flown in a near-circular orbit with an inclination of 28.5 degrees. Initially, the orbit altitude was approximately 257 nautical miles; however, when the LDEF was retrieved the orbit altitude had decayed to approximately 179 nautical miles. The LDEF was passively stabilized about three axes while in free flight, making it an ideal platform for exposing experiments which were measuring the environments of near-Earth space and investigating the long-term effects of these environments on spacecraft. A brief overview of the encountered environments that were of most interest to the LDEF investigators is presented.

Kinard, William H.↗

NASA's Rodent Research Project: Validation of Capabilities for Conducting Long Duration Experiments in Space

Research using rodents is an essential tool for advancing biomedical research on Earth and in space. Prior rodent experiments on the Shuttle were limited by the short flight duration. The International Space Station (ISS) provides a new platform for conducting rodent experiments under long duration conditions. Rodent Research (RR)-1 was conducted to validate flight hardware, operations, and science capabilities that were developed at the NASA Ames Research Center. Twenty C57BL6J adult female mice were launched on Sept 21, 2014 in a Dragon Capsule (SpaceX-4), then transferred to the ISS for a total time of 21-22 days (10 commercial mice) or 37 days (10 validation mice). Tissues collected on-orbit were either rapidly frozen or preserved in RNAlater at -80C (n2group) until their return to Earth. Remaining carcasses on-orbit were rapidly frozen for dissection post-flight. The three controls groups at Kennedy Space Center consisted of: Basal mice euthanized at the time of launch, Vivarium controls housed in standard cages, and Ground Controls (GC) housed in flight hardware within an environmental chamber. Upon return to Earth, there were no differences in body weights between Flight (FLT) and GC at the end of the 37 days in space. Liver enzyme activity levels of FLT mice and all control mice were similar in magnitude to those of the samples that were processed under optimal conditions in the laboratory. Liver samples dissected on-orbit yielded high quality RNA (RIN8.99+-0.59, n7). Liver samples dissected post-flight from the intact, frozen FLT carcasses yielded RIN of 7.27 +- 0.52 (n6). Additionally, wet weights of various tissues were measured. Adrenal glands and spleen showed no significant differences in FLT compared to GC although thymus and livers weights were significantly greater in FLT compared to GC. Over 3,000 tissue aliquots collected post-flight from the four groups of mice were deposited into the Ames Life Science Data Archives for future Biospecimen Sharing Program. Together, the RR validation flight successfully demonstrates the capability to support long-duration experimentation on the ISS to achieve both basic science and biomedical objectives.

spaceflight↗

Joint US-USSR Long duration Antarctic Mars calibration Balloon (LAMB) mission

The Long duration Antarctic Mars calibration Balloon (LAMB) project has been established at Goddard Space Flight Center for the evaluation and cross calibration of U.S. and USSR remote sensing gamma-ray and neutron detectors. These detectors are analogs of those flown on the Soviet Phobos mission around Mars and those to be flown on the upcoming U.S. Mars Observer mission. Cosmic rays, which are normally filtered out by the atmosphere, and the earth's magnetic field, will induce gamma-ray and neutron emissions from about a half ton of simulated Mars soil aboard the gondola. The cross calibration of these instruments should greatly facilitate the data analysis from both missions and play a role in U.S.-USSR cooperation in space.

Floyd, S. R.↗

Enabling Long-Duration Lunar Equatorial Operations With Thermal Wadi Infrastructure

Long duration missions on the Moon s equator must survive lunar nights. With 350 hr of cryogenic temperatures, lunar nights present a challenge to robotic survival. Insulation is imperfect, so it is not possible to passively contain enough heat to stay warm through the night. Components that enable mobility, environmental sensing and solar power generation must be exposed, and they leak heat. Small, lightweight rovers cannot store enough energy to warm components throughout the night without some external source of heat or power. Thermal wadis, however, can act as external heat sources to keep robots warm through the lunar night. Electrical power can also be provided to rovers during the night from batteries stored in the ground beside wadis. Buried batteries can be warmed by the wadi s heat. Results from analysis of the interaction between a rover and a wadi are presented. A detailed three-dimensional (3D) thermal model and an easily configurable two-dimensional (2D) thermal model are used for analysis.

Jones, Heather L.↗

TBS (Trabecular Bone Score) Expands Understanding of Spaceflight Effects on the Lumbar Spine of Long Duration Astronauts

Background: Bone loss due to long-duration spaceflight has been characterized by both DXA and QCT serial scans. It is unclear if these spaceflight-induced changes in bone mineral density and structure result in increased fracture incidence. NASA astronauts currently fly on 5-6-month missions on the International Space Station (ISS) and at least one 12-month mission is planned. While NASA has measured areal BMD (by DXA) and volumetric BMD (by QCT), and has estimated hip strength (by finite element models of QCT data, no method has yet been used to examine bone microarchitecture from lumbar spine (LS). DXA scans are routinely performed pre- and post-flight on all ISS astronauts to follow BMD changes associated with space flight. Trabecular Bone Score (TBS) is a relatively new method that measures grey-scale-level texture information extracted from lumbar spine DXA images and correlates with 3D parameters of bone micro-architecture. We evaluated the ability of LS TBS to discriminate changes in astronauts who have flown on ISS missions and to determine if TBS can provide additional information compared to DXA. Methods: LS (L1-4) DXA scans from 51 astronauts (mean age, 47 +/- 4) were divided into 3 groups based on the exercise regimes performed while onboard the ISS. Pre-ARED (exercise using a load-limited resistive exercise device, <300lb), ARED (exercise with a high-load resistive exercise device, up to 600lb) and a Bisphos group (ARED exercise and a 70-mg alendronate tablet once a week before and during flight, starting 17 days before launch). DXA scans were performed and analyzed on a Hologic Discovery W using the same technician for the pre- and postflight scans. LSC for the LS in our laboratory is 0.025 g/cm2. TBS was performed at the Mercy Hospital, Cincinnati, Ohio on a similar Hologic computer. TBS precision was calculated from 16 comparable test subjects (0.0XX g/cm2). Data were preliminary analyzed using a paired, 2-tailed t-test for the difference between pre- and postflight means.

Sibonga, Jean D.↗

Post-Test Inspection of NASA's Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge Chamber

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014 after demonstrating 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for the discharge chamber as well as other miscellaneous components such as the high-voltage propellant isolators and electrical cabling. Comparison of magnetic field measurements taken during pretest and post-test inspections indicate that the field strength did not degrade, consistent with performance data obtained during the test. Inspection of discharge chamber mesh samples show a deposition coating primarily composed of grid material that is approximately 15 micrometers in thickness. This thickness is well within the retention capability of the mesh and is therefore not expected to present any issues. Approximately 3.1 grams of deposition flakes were found at the bottom of the discharge chamber, composed primarily of grid material and carbon. Calculated size histograms of these flakes indicate that 99% have a maximum dimension of 200 micrometers or smaller, which is significantly less than the ion optics grid gap. Larger flakes that are capable of causing a grid-to-grid short will be analyzed to determine if their formation will occur in flight or is a facility effect. The high-voltage propellant isolators as well as numerous other electrical insulators were inspected and no evidence of arcing or any other issues were found.

Electric Propulsion↗

Teamwork Training Needs Analysis for Long-Duration Exploration Missions

The success of future long-duration exploration missions (LDEMs) will be determined largely by the extent to which mission-critical personnel possess and effectively exercise essential teamwork competencies throughout the entire mission lifecycle (e.g., Galarza & Holland, 1999; Hysong, Galarza, & Holland, 2007; Noe, Dachner, Saxton, & Keeton, 2011). To ensure that such personnel develop and exercise these necessary teamwork competencies prior to and over the full course of future LDEMs, it is essential that a teamwork training curriculum be developed and put into place at NASA that is both 1) comprehensive, in that it targets all teamwork competencies critical for mission success and 2) structured around empirically-based best practices for enhancing teamwork training effectiveness. In response to this demand, the current teamwork-oriented training needs analysis (TNA) was initiated to 1) identify the teamwork training needs (i.e., essential teamwork-related competencies) of future LDEM crews, 2) identify critical gaps within NASA’s current and future teamwork training curriculum (i.e., gaps in the competencies targeted and in the training practices utilized) that threaten to impact the success of future LDEMs, and to 3) identify a broad set of practical nonprescriptive recommendations for enhancing the effectiveness of NASA’s teamwork training curriculum in order to increase the probability of future LDEM success.

Smith-Jentsch, Kimberly A.↗

Post-test Inspection of NASA’s Evolutionary Xenon Thruster Long-Duration Test Hardware: Discharge Chamber

The NEXT Long-Duration Test is part of a comprehensive thruster service life assessment intended to demonstrate overall throughput capability, validate service life models, quantify wear rates as a function of time and operating condition, and identify any unknown life-limiting mechanisms. The test was voluntarily terminated in February 2014after demonstrating 51,184 hours of high-voltage operation, 918 kg of propellant throughput, and 35.5 MN-s of total impulse. The post-test inspection of the thruster hardware began shortly afterwards with a combination of non-destructive and destructive analysis techniques, and is presently nearing completion. This paper presents relevant results of the post-test inspection for the discharge chamber as well as other miscellaneous components such as the high-voltage propellant isolators and electrical cabling. Comparison of magnetic field measurements taken during pretest and post-test inspections indicate that the field strength did not degrade, consistent with performance data obtained during the test. Inspection of discharge chamber mesh samples show a deposition coating primarily composed of grid material that is approximately 15 μm in thickness. This thickness is well within the retention capability of the mesh and is therefore not expected to present any issues. Approximately 3.1 grams of deposition flakes were found at the bottom of the discharge chamber, composed primarily of grid material and carbon. Calculated size histograms of these flakes indicate that 99% have a maximum dimension of 200 μm or smaller, which is significantly less than the ion optics grid gap. Larger flakes that are capable of causing a grid-to-grid short will be analyzed to determine if their formation will occur in flight or is a facility effect. The high-voltage propellant isolators as well as numerous other electrical insulators were inspected and no evidence of arcing or any other issues were found.

Rohit Shastry↗

Neuronal plasticity in relation to long-duration spaceflight

Exposure to microgravity leads to a marked reduction in sensory-motor stimuli to the vestibular, proprioceptive and somatosensory systems. Long-duration missions, such as those proposed for a trip to Mars, may lead to significant changes in neural function. This paper presents results based on studies of sensory deafferentation of specific brain regions and detailed changes which occur in neuronal architecture. Data from these studies emphasize the need for further research related to sensory system deprivation and the development of new unique countermeasures for long-duration space flight.

Hillman, Dean E.↗

Astronaut Preflight Cardiovascular Variables Associated with Vascular Compliance are Highly Correlated with Post-Flight Eye Outcome Measures in the Visual Impairment Intracranial Pressure (VIIP) Syndrome Following Long Duration Spaceflight

The detection of the first VIIP case occurred in 2005, and adequate eye outcome measures were available for 31 (67.4%) of the 46 long duration US crewmembers who had flown on the ISS since its first crewed mission in 2000. Therefore, this analysis is limited to a subgroup (22 males and 9 females). A "cardiovascular profile" for each astronaut was compiled by examining twelve individual parameters; eleven of these were preflight variables: systolic blood pressure, pulse pressure, body mass index, percentage body fat, LDL, HDL, triglycerides, use of anti‐lipid medication, fasting serum glucose, and maximal oxygen uptake in ml/kg. Each of these variables was averaged across three preflight annual physical exams. Astronaut age prior to the long duration mission, and inflight salt intake was also included in the analysis. The group of cardiovascular variables for each crew member was compared with seven VIIP eye outcome variables collected during the immediate post‐flight period: anterior-posterior axial length of the globe measured by ultrasound and optical biometry; optic nerve sheath diameter, optic nerve diameter, and optic nerve to sheath ratio‐ each measured by ultrasound and magnetic resonance imaging (MRI), intraocular pressure (IOP), change in manifest refraction, mean retinal nerve fiber layer (RNFL) on optical coherence tomography (OCT), and RNFL of the inferior and superior retinal quadrants. Since most of the VIIP eye outcome measures were added sequentially beginning in 2005, as knowledge of the syndrome improved, data were unavailable for 22.0% of the outcome measurements. To address the missing data, we employed multivariate multiple imputation techniques with predictive mean matching methods to accumulate 200 separate imputed datasets for analysis. We were able to impute data for the 22.0% of missing VIIP eye outcomes. We then applied Rubin's rules for collapsing the statistical results across our 200 multiply imputed data sets to assess the canonical correlation between the eye outcomes and the twelve astronaut cardiovascular variables available for all 31 subjects. Results: A highly significant canonical correlation was observed among the canonical solutions (p<.00001), with an average best canonical correlation of.97. The results suggest a strong association between astronauts' measures of cardiovascular health and the seven eye outcomes of the VIIP syndrome used in this analysis. Furthermore, the "joint test" revealed a significant difference in cardiovascular profile between male and female astronauts (Prob > F = 0.00001). Overall, female astronauts demonstrated a significantly healthier cardiovascular status. Individually, the female astronauts had significantly healthier profiles on seven of twelve cardiovascular variables than the men (p values ranging from <0.0001 to <0.05). Male astronauts did not demonstrate significantly healthier values on any of the twelve cardiovascular variables measured

Otto, Christian↗

Long Duration Hot Hydrogen Exposure of Nuclear Thermal Rocket Materials

An arc-heater driven hyper-thermal convective environments simulator was recently developed and commissioned for long duration hot hydrogen exposure of nuclear thermal rocket materials. This newly established non-nuclear testing capability uses a high-power, multi-gas, wall-stabilized constricted arc-heater to .produce high-temperature pressurized hydrogen flows representative of nuclear reactor core environments, excepting radiation effects, and is intended to serve as a low cost test facility for the purpose of investigating and characterizing candidate fuel/structural materials and improving associated processing/fabrication techniques. Design and engineering development efforts are fully summarized, and facility operating characteristics are reported as determined from a series of baseline performance mapping runs and long duration capability demonstration tests.

Litchford, Ron J.↗

Comparing Long-Duration Gamma-Ray Flares and High-Energy Solar Energetic Particles

Little is known about the origin of the high-energy and sustained emission from solar long-duration gamma-ray flares (LDGRFs) identified with the Compton Gamma Ray Observatory, the Solar Maximum Mission, and now Fermi. Though the Fermi Large Area Telescope (LAT) has identified dozens of flares with LDGRF signatures, the nature of this phenomenon has been a challenge to explain due to both extreme energies and long durations. The highest-energy emission has generally been attributed to pion production from the interaction of 300 MeV protons with the ambient matter. The extended duration suggests that particle acceleration occurs over large volumes extending high in the corona, either from stochastic acceleration within large coronal loops or from back precipitation from coronal mass ejection–driven shocks. It is possible to test these models by making a direct comparison between the properties of the accelerated ion population producing the γ-ray emission derived from the Fermi/LAT observations and the characteristics of solar energetic particles (SEPs) measured by the Payload for Matter-Antimatter Exploration and Light Nuclei Astrophysics spacecraft in the energy range corresponding to the pion-related emission detected with Fermi. For 14 of these events, we compare the two populations—SEPs in space and the interacting particles at the Sun—and discuss the implications in terms of potential sources. Our analysis shows that the two proton numbers are poorly correlated, with their ratio spanning more than 5 orders of magnitude, suggesting that the back precipitation of shock-acceleration particles is unlikely to be the source of the F emission.

Nolfo, G. A. de↗

Effect of long-duration spaceflight on postural control during self-generated perturbations

This report is the first systematic evaluation of the effects of prolonged weightlessness on the bipedal postural control processes during self-generated perturbations produced by voluntary upper limb movements. Spaceflight impacts humans in a variety of ways, one of which is compromised postflight postural control. We examined the neuromuscular activation characteristics and center of pressure (COP) motion associated with arm movement of eight subjects who experienced long-duration spaceflight (3--6 mo) aboard the Mir space station. Surface electromyography, arm acceleration, and COP motion were collected while astronauts performed rapid unilateral shoulder flexions before and after spaceflight. Subjects generally displayed compromised postural control after flight, as evidenced by modified COP peak-to-peak anterior-posterior and mediolateral excursion, and pathlength relative to preflight values. These changes were associated with disrupted neuromuscular activation characteristics, particularly after the completion of arm acceleration (i.e., when subjects were attempting to maintain upright posture in response to self-generated perturbations). These findings suggest that, although the subjects were able to assemble coordination modes that enabled them to generate rapid arm movements, the subtle control necessary to maintain bipedal equilibrium evident in their preflight performance is compromised after long-duration spaceflight.

NASA Discipline Neuroscience↗

Aerobic Capacity Following Long Duration International Spaces Station (ISS) Missions: Preliminary Results

Maximum oxygen uptake (VO2max) is reduced immediately following space flights lasting <15 d, but has not been measured following long-duration missions. The purpose of this study is to measure VO2max and maximum work rate (WRmax) data from astronauts following ISS flights (91 to 188 d). Methods: Five astronauts [3 M, 2 F: 47+/-6 yr, 174+/-6 cm, 71.9+/-10.9 kg (mean +/- SD)] have participated in the study. Subjects performed upright cycle exercise tests to symptom-limited maximum. An initial test was done approx.270 d before flight to establish work rates for subsequent tests. Subsequent tests, conducted approx.45 d before flight and repeated on the first or second day (R+1/2) and at approx.10 d (R+10) following landing, consisted of 3 5 min stages designed to elicit 25%, 50%, and 75% of preflight VO2max, followed by 25 W(dot)/min increases. VO2, WR, and heart rate (HR) were measured using the ISS Portable Pulmonary Function System [Damec, Odense, DK]. Descriptive statistics are reported. Results: On R+1/2 mean VO2max decreased compared to preflight (Pre: 2.98+/-0.99, R+1/2: 2.63+/-0.56 L(dot)/min); 4 of 5 subjects demonstrated a loss of > 6%. WRmax also decreased on R+1/2 compared to preflight (Pre: 245+/-69, R+1/2: 210+/-45 W). On R+10, VO2max was 2.86+/-0.62 L(dot)/min, with 2 subjects still demonstrating a loss of > 6% from preflight. WRmax on R+10 was 240+/-49 W. HRmax did not change from pre to post-flight. Conclusions: These preliminary results, from the first 5 of 12 planned subjects of an ongoing ISS study, suggest that the majority of astronauts will experience a decrease in VO2max after long-duration space-flight. Interestingly, the two astronauts with the highest preflight VO2max had the greatest loss on R+1/2, and the astronaut with the lowest preflight VO2max increased by 13%. Thus, maintenance of VO2max may be more difficult in astronauts who have a high aerobic capacity, perhaps requiring more intense in-flight exercise countermeasure prescriptions.

Moore, Alan D.↗

The frequency of long-duration solar X-ray events

The rate of occurrence of coronal and interplanetary phenomena during the solar sunspot cycle was studied based on nearly continuous satellite data for long-duration events in the period 1969-1982. The data were obtained using the NRL SOLRAD and the NOAA GOES spacecraft for each year in the interval. The duration of the X-ray events was defined as the time for the logarithm of the 1-8 A flux to return to approximately 10 percent of the pre-event level. The total number of X-ray events is plotted next to the annual sunspot number for the interval 1969-1982. It is shown that the long duration of X-ray events was not related to the sunspot cycle, particularly events of 6 hr or more.