Search NASA⌕ Search

SEARCH · Search NASA

Results for “Low threshold detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Aluminum relaxation as the source of excess low energy events in low threshold calorimeters

A previously unexplained background called the Low Energy Excess has negatively impacted the reach of a variety of low threshold calorimeters including light dark matter direct detection and coherent elastic neutrino-nucleus scattering experiments. The relaxation of stressed aluminum films as mediated by the motion of dislocations may account for these observations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of cosmogenic activation above ground for the DarkSide-20k experiment

The activation of materials due to exposure to cosmic rays may become an important background source for experiments investigating rare event phenomena. DarkSide-20k, currently under construction at the Laboratori Nazionali del Gran Sasso, is a direct detection experiment for galactic dark matter particles, using a two-phase liquid-argon Time Projection Chamber (TPC) filled with 49.7 tonnes (active mass) of Underground Argon (UAr) depleted in 39 Ar. Despite the outstanding capability of discriminating γ / β background in argon TPCs, this background must be considered because of induced dead time or accidental coincidences mimicking dark-matter signals and it is relevant for low-threshold electron-counting measurements. Here, the cosmogenic activity of relevant long-lived radioisotopes induced in the experiment has been estimated to set requirements and procedures during preparation of the experiment and to check that it is not dominant over primordial radioactivity; particular attention has been paid to the activation of the 120 t of UAr used in DarkSide-20k. Expected exposures above ground and production rates, either measured or calculated, have been considered in detail. From the simulated counting rates in the detector due to cosmogenic isotopes, it is concluded that activation in copper and stainless steel is not problematic. The activity of 39 Ar induced during extraction, purification and transport on surface is evaluated to be 2.8% of the activity measured in UAr by DarkSide-50 experiment, which used the same underground source, and thus considered acceptable. Other isotopes in the UAr such as 37 Ar and 3 H are shown not to be relevant due to short half-life and assumed purification methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity of nEXO to 136 Xe charged-current interactions: Background-free searches for solar neutrinos and fermionic dark matter

We study the sensitivity of nEXO to solar neutrino charged-current interactions, 𝜈 𝑒 + 136 Xe → 136 Cs*+𝑒 − , as well as analogous interactions predicted by models of fermionic dark matter. Due to the recently observed low-lying isomeric states of 136 Cs, these interactions will create a time-delayed coincident signal observable in the scintillation channel. Here we develop a detailed Monte Carlo simulation of scintillation emission, propagation, and detection in the nEXO detector to model these signals under different assumptions about the timing resolution of the photosensor readout. We show this correlated signal can be used to achieve background discrimination on the order of 10 −9 , enabling nEXO to make background-free measurements of solar neutrinos above the reaction threshold of 0.668 MeV. We project that nEXO could measure the flux of neutrinos from the carbon-nitrogen-oxygen cycle with a statistical uncertainty of 25%, thus contributing a novel and competitive measurement toward addressing the solar metallicity problem. Additionally, nEXO could measure the mean energy of the 7 Be neutrinos with a precision of 𝜎 ≤ 1.5 keV and could determine the survival probability of 7 Be and pep solar 𝜈𝑒 with precision comparable to the state of the art. These quantities are sensitive to the Sun’s core temperature and to nonstandard neutrino interactions, respectively. Here, the strong background suppression would allow nEXO to search for charged-current interactions of fermionic dark matter in the mass range 𝑚 𝜒 = 0.668–7 MeV with a sensitivity up to three orders of magnitude better than current limits.

47 OTHER INSTRUMENTATION↗

First Measurement of Differential Charged Current Quasielasticlike $\nu_{\mu}$ -Argon Scattering Cross Sections with the MicroBooNE Detector

We report on the first measurement of flux-integrated single differential cross sections for charged-current (CC) muon neutrino ($\nu_{\mu}$) scattering on argon with a muon and a proton in the final state, 40 Ar $(\nu_{\mu},μp)X$. The measurement was carried out using the Booster Neutrino Beam at Fermi National Accelerator Laboratory and the MicroBooNE liquid argon time projection chamber detector with an exposure of 4.59 × 10 19 protons on target. Events are selected to enhance the contribution of CC quasielastic (CCQE) interactions. The data are reported in terms of a total cross section as well as single differential cross sections in final state muon and proton kinematics. We measure the integrated per-nucleus CCQE-like cross section (i.e., for interactions leading to a muon, one proton, and no pions above detection threshold) of (4.93 ± 0.76 stat ± 1.29 sys )×10 -38 cm 2 , in good agreement with theoretical calculations. The single differential cross sections are also in overall good agreement with theoretical predictions, except at very forward muon scattering angles that correspond to low-momentum-transfer events.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Searches for low-mass dimuon resonances

Searches are performed for a low-mass dimuon resonance, X, produced in proton-proton collisions at a center-of-mass energy of 13 TeV, using a data sample corresponding to an integrated luminosity of 5.1 fb -1 and collected with the LHCb detector. The X bosons can either decay promptly or displaced from the proton-proton collision, where in both cases the requirements placed on the event and the assumptions made about the production mechanisms are kept as minimal as possible. The searches for promptly decaying X bosons explore the mass range from near the dimuon threshold up to 60 GeV, with nonnegligible X widths considered above 20 GeV. The searches for displaced $X → µ^+µ^-$ decays consider masses up to 3 GeV. None of the searches finds evidence for a signal and 90% confidence-level exclusion limits are placed on the $X → µ^+µ^-$ cross sections, each with minimal model dependence. In addition, these results are used to place world-leading constraints on GeV-scale bosons in the two-Higgs-doublet and hidden-valley scenarios.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exploring the keV-scale physics potential of CUORE

We present the analysis techniques developed to explore the keV-scale energy region of the Cryogenic Underground Observatory for Rare Events (CUORE) experiment, based on more than 2 metric ton yr of data collected over five years. By prioritizing a stricter selection over a larger exposure, we are able to optimize data selection for thresholds at 10 keV and 3 keV with 691 kg yr and 11 kg yr of data, respectively. We study how the performance varies among the 988-detector array with different detector characteristics and data-taking conditions. We achieve an average baseline resolution of 2.54 ±0.14 keV FWHM and 1.18 ±0.02 keV FWHM for the data selection at 10 keV and 3 keV, respectively. The analysis methods employed reduce the overall background by about an order of magnitude, reaching 2.06±0.05 counts/(keV kg days) and 16±2 counts/(keV kg days) at the thresholds of 10 keV and 3 keV. We evaluate for the first time the near-threshold reconstruction efficiencies of the CUORE experiment, and find these to be 50 ±2% and 26 ±4% at 10 keV and 3 keV, respectively. This analysis provides crucial insights into rare decay studies, new physics searches, and keV-scale background modeling with CUORE. We demonstrate that ton-scale cryogenic calorimeters can operate across a wide energy range, from keV to MeV, establishing their scalability as versatile detectors for rare event and dark matter physics. These findings also inform the optimization of future large mass cryogenic calorimeters to enhance the sensitivity to low-energy phenomena.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutron Identification Capabilities in MicroBooNE Through the Application of Machine Learning with Blips

Neutrinos (ν) are subatomic particles first observed in 1956 by LANL physicists Clyde Cowan and Frederick Reines but first theorized by Wolfgang Pauli in 1930. Neutrinos are the least massive known particle and are classified as leptons with 3 flavors corresponding to their leptonic counterparts (electron, muon, and tau). We know that they are abundant, 65 billion neutrinos travel through your fingertip every second, and elusive, a single neutrino could fly through a lightyear of lead without interacting at all. Though, there is much still unknown and a better characterization of these “ghostly” particles can give us clues as to the matter/anti-matter asymmetry in the early universe and possible glimpses into new physics. To measure a particle that is extremely light and rarely interacting, physicists have developed an extremely sensitive detector known as a Liquid Argon Time Projection Chamber (LArTPC). The fiducial volume (or TPC) is bombarded with neutrinos, some of which interact with argon (Ar) atoms to produce particles that in turn excite and ionize the Ar. The products of these are free electrons which then drift through the TPC’s applied magnetic field towards a multi-plane wire readout system. The electrons’ charge is collected at this anode and the light from the initial interactions is collected by photomultiplier tubes (PMTs). In conjunction, these mechanisms allow LArTPCs to achieve millimeter spatial resolution and sub-MeV energy thresholds. The detector of interest in this study is the MicroBooNE Experiment at Fermilab. MicroBooNE is an above ground LArTPC with dimensions of approximately 10m × 2.5m × 2.3m, about the size of a school bus. Its purpose is to study neutrinos, so to improve rates of measured ν interactions, the detector is squarely in the path of the Booster Neutrino Beam (BNB) at Fermilab. A major challenge in neutrino studies is energy reconstruction, much of the neutrino’s original energy is lost in interactions that the detector is not sensitive to, often due to low-energy products. The initial goal of this analysis was to better identify neutrons, the main source of poor energy reconstruction in neutrino events. Because neutrons are neutral particles, like neutrinos, we can only directly measure the products of their interactions in LArTPCs. Most of these products are low-energy signals and while each one contributes a negligible amount of energy, collectively these signals make up most of the lost energy in each neutrino event. We define these signals as blips; point-like, isolated depositions of charge in the detector. Blips have MeV-scale energies and are the size of a single hit (charge deposition) or a cluster of a few hits on at least two wire planes. Blips are the principal detector features used to study low-energy physics; thus, they are the key to unlocking information not only about neutrons but gamma photons, supernova and solar neutrinos as well as helping us better identify certain particles. Therefore, this analysis strives to use blips for improved neutron identification (ID) and characterization.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single-nucleon knockout cross sections for reactions producing resonance states at or beyond the drip line

Single-nucleon knockout cross sections from fast secondary beams of the proton-drip-line nuclei 9 C, 13 O, and 17 Ne on a 9 Be target have been studied with emphasis on the production of resonance states. These states were identified by their invariant mass, and resonances with two-, three-, and five-body exit channels were examined. The measured cross sections for these states were compared with eikonal-model predictions using shell-model or variational Monte Carlo spectroscopic factors. The experimental yields were found to be suppressed relative to the model predictions, especially when a well-bound neutron or proton is removed. This suppression exceeds that found systematically in measured inclusive cross sections to particle-bound final states. In neutron knockout from 9 C and 13 O projectiles, this suppression of the unbound ground-state residuals yield is a factor of two to three times larger than that found in the bound final-state studies. Modifications to the structure of these systems due to coupling of the shell-model configurations to the continuum is expected to contribute to this extra suppression, especially when the final state is a near-threshold resonance. Furthermore, other considerations including the role of nuclear dynamics may be required to explain all the observed trends.

6 ≤ A ≤ 19↗

Developing new analysis tools for near surface radio-based neutrino detectors

The ARIANNA experiment is an Askaryan radio detector designed to measure high-energy neutrino induced cascades within the Antarctic ice. Ultra-high-energy neutrinos above 10 16 eV have an extremely low flux, so experimental data captured at trigger level need to be classified correctly to retain as much neutrino signal as possible. We first describe two new physics-based neutrino selection methods, or "cuts", (the updown and dipole cut) that extend the previously published analysis to a specialized ARIANNA station with 8 antenna channels, which is double the number used in the prior analysis. For a standard trigger with a threshold signal to noise ratio at 4.4, the new cuts produce a neutrino efficiency of > 95% per station-year of operation, while rejecting 99.93% of the background (corresponding to 53 remaining experimental background events). When the new cuts are combined with a previously developed cut using neutrino waveform templates, all background is removed at no change of efficiency. In addition, the neutrino efficiency is extrapolated to 1,000 station-years of operation, obtaining 91%. This work then introduces a new selection method (the deep learning cut) to augment the identification of neutrino events by using deep learning methods and compares the efficiency to the physics-based analysis. The deep learning cut gives 99% signal efficiency per station-year of operation while rejecting 99.997% of the background (corresponding to 2 remaining experimental background events), which are subsequently removed by the waveform template cut at no significant change in efficiency. Here the results of the deep learning cut were verified using measured cosmic rays which shows that the simulations do not introduce artifacts with respect to experimental data. The paper demonstrates that the background rejection and signal efficiency of near surface antennas meets the requirements of a large scale future array, as considered in baseline design of the radio component of IceCube-Gen2.

97 MATHEMATICS AND COMPUTING↗

The Analog Front-end for the LGAD Based Precision Timing Application in CMS ETL

The analog front-end for the Low Gain Avalanche Detector (LGAD) based precision timing application in the CMS Endcap Timing Layer (ETL) has been prototyped in a 65 nm CMOS mini-ASIC named ETROC0. Serving as the very first prototype of ETL readout chip (ETROC), ETROC0 aims to study and demonstrate the performance of the analog frontend, with the goal to achieve 40 to 50 ps time resolution per hit with LGAD (therefore reach about 30ps per track with two detector-layer hits per track). ETROC0 consists of preamplifier and discriminator stages, which amplifies the LGAD signal and generates digital pulses containing time of arrival and time over threshold information. This paper will focus on the design considerations that lead to the ETROC front-end architecture choice, the key design features of the building blocks, the methodology of using the LGAD simulation data to evaluate and optimize the front-end design. The ETROC0 prototype chips have been extensively tested using charge injection and the measured performance agrees well with simulation. The initial beam test results are also presented, with time resolution of around 33 ps observed from the preamplifier waveform analysis and around 41 ps from the discriminator pulses analysis. A subset of ETROC0 chips have also been tested to a total ionizing dose of 100 MRad with X-ray and no performance degradation been observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of photosensors in a high-rate environment for gas Cherenkov detectors

We report the solenoidal large intensity device (SoLID) at Jefferson Lab will push the boundaries of luminosity for a large-acceptance detector, which necessitates the use of a light-gas threshold Cherenkov counter for online event selection. Due to the high luminosity, the single-photon background rate in this counter can exceed 160 kHz/cm 2 at the photosensors. Therefore, it is essential to validate the high-rate limits of the planned photosensors and readout electronics in order to mitigate the risk of failure. We report on the design and an early set of studies carried out using a small Cherenkov counter in a high-rate environment up to 60 kHz/cm 2 , in Hall C at Jefferson Lab. Commercially available multi-anode photomultipliers (MaPMT) and low-cost large-area picosecond photodetectors (LAPPD) were tested using the JLab FADC250 modules for readout. The test beam results show that the MaPMT array and the internal stripline LAPPD can detect and identify single-electron and pair-production events in high-rate environments. Due to its higher quantum efficiency, the MaPMT array provided a better separation between the single-electron and the pair-production events compared to the internal stripline LAPPD. A GEANT4 simulation confirms the beam test performance of our counter device.

47 OTHER INSTRUMENTATION↗

A Flux-Tunable cavity for Dark matter detection

Developing a dark matter detector with wide mass tunability is an immensely desirable property, yet it is challenging due to maintaining strong sensitivity. Resonant cavities for dark matter detection have traditionally employed mechanical tuning, moving parts around to change electromagnetic boundary conditions. However, these cavities have proven challenging to operate in sub-Kelvin cryogenic environments due to differential thermal contraction, low heat capacities, and low thermal conductivities. Instead, we develop an electronically tunable cavity architecture by coupling a superconducting 3D microwave cavity with a DC flux tunable SQUID. With a flux delivery system engineered to maintain high coherence in the cavity, we perform a hidden-photon dark matter search below the quantum-limited threshold. A microwave photon counting technique is employed through repeated quantum non-demolition measurements using a transmon qubit. With this device, we perform a hidden-photon search and constrain the kinetic mixing angle to ${\varepsilon}< 8.2\times 10^{-15}$ in a tunable band from 5.672 GHz to 5.694 GHz. By coupling multimode tunable cavities to the transmon, wider hidden-photon searching ranges are possible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dual particle imaging using time-of-flight neutron classification

Fast-neutron imaging technology is well-suited for passive nuclear material monitoring, secondary inspection of flagged cargo, and wide-area search for lost neutron sources. However, imaging systems that use pulse shape discrimination for event classification require complex pulse waveform analysis. In this work, we evaluate time-of-flight (TOF) based particle classification as an alternative solution for fast-neutron imaging by classifying all events with a TOF above a maximum threshold as neutrons. We measured a Cf-252 source next to Cs-137 using a 12-bar organic-glass scintillator array. By varying the TOF thresholds for neutron identification, we demonstrate a clear trade-off between event yield and backprojection image fidelity, with stricter thresholds improving precision at the cost of statistics, TOF thresholded data generated an image that predicted the neutron source direction with 20% reduced mean central angle prediction error compared to a traditional pulse shape discrimination (PSD) method with comparable event count. Time-of-flight particle classification shows promise as an alternative to pulse shape discrimination systems for fast neutron imaging systems looking to minimize costs and size of electronics with comparable imaging quality. The sources used demonstrate that the method is effective in classifying measured neutrons in a measurement environment with 150 μCi Cs-137 and 1.6 × 10 6 n/s Cf-252 sources positioned at distances of 66 cm and 81 cm from the detector. Additionally, the method classifies low-energy neutron events that pulse shape discrimination removes, so a combination of both methods would result in a higher overall neutron event efficiency.

Heriot, William [Univ. of Michigan, Ann Arbor, MI ↗

Performance of a Front End prototype ASIC for picosecond precision time measurements with LGAD sensors

For the High-Luminosity phase of LHC, the ATLAS experiment is proposing the addition of a High Granularity Timing Detector (HGTD) in the forward region, to mitigate the effects of the increased pile-up. The chosen detection technology is Low Gain Avalanche Detector (LGAD) silicon sensors that can provide an excellent timing resolution below 50 ps. The front-end read-out ASIC must exploit the large signal derivative and small noise provided by the sensor, while keeping low power consumption. This paper presents the results on the first prototype of a front-end ASIC, named ALTIROC0, which contains the analog stages (preamplifier and discriminator) of the read-out chip. The ASIC was characterised both alone and as part of a module with a 2×2 LGAD array of 1.1×1.1 mm 2 pads bump-bonded to it. The various contributions of the electronics to the time resolution were investigated in test-bench measurements with a calibration setup. Both when the ASIC is alone or with a bump-bonded sensor, the jitter of the ASIC is better than 20 ps for an injected charge of 10 fC. The time walk effect, which arises from the different preamplifier response for various injected charges, can be corrected up to 10 ps using a Time Over Threshold measurement. The combined performance of the ASIC and the LGAD sensor, which was measured during a beam test campaign in October 2018 with pions of 120 GeV energy at the CERN SPS, is around 40 ps for all measured modules. All tested modules show good efficiency and time resolution uniformity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Carbon-13 Radiofrequency Amplification by Stimulated Emission of Radiation of the Hyperpolarized Ketone and Hemiketal Forms of Allyl [1- 13 C]Pyruvate

13 C hyperpolarized pyruvate is an emerging MRI contrast agent for sensing molecular events in cancer and other diseases with aberrant metabolic pathways. This metabolic contrast agent can be produced via several hyperpolarization techniques. Despite remarkable success in research settings, widespread clinical adoption faces substantial roadblocks because the current sensing technology utilized to sense this contrast agent requires the excitation of 13 C nuclear spins that also need to be synchronized with MRI field gradient pulses. Here, we demonstrate sensing of hyperpolarized allyl [1- 13 C]pyruvate via the stimulated emission of radiation that mitigates the requirements currently blocking broader adoption. Specifically, 13 C Radiofrequency Amplification by Stimulated Emission of Radiation ( 13 C RASER) was obtained after pairwise addition of parahydrogen to a pyruvate precursor, detected in a commercial inductive detector with a quality factor (Q) of 32 for sample concentrations as low as 0.125 M with 13 C polarization of 4%. Moreover, parahydrogen-induced polarization allowed for the preparation of a mixture of ketone and hemiketal forms of hyperpolarized allyl [1- 13 C]pyruvate, which are separated by 10 ppm in 13 C NMR spectra. This is a good model system to study the simultaneous 13 C RASER signals of multiple 13 C species. This system models the metabolic production of hyperpolarized [1- 13 C]lactate from hyperpolarized [1- 13 C]pyruvate, which has a similar chemical shift difference. Our results show that 13 C RASER signals can be obtained from both species simultaneously when the emission threshold is exceeded for both species. On the other hand, when the emission threshold is exceeded only for one of the hyperpolarized species, 13 C stimulated emission is confined to this species only, therefore enabling the background-free detection of individual hyperpolarized 13 C signals. Furthermore, the reported results pave the way to novel sensing approaches of 13 C hyperpolarized pyruvate, potentially unlocking hyperpolarized 13 C MRI on virtually any MRI system–an attractive vision for the future molecular imaging and diagnostics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of silicon and indium gallium arsenide photodiodes as direct timing detectors for pulsed x-ray systems

Benchtop pulsed x-ray systems are commonly used to record dynamic material data on the order of nanoseconds, but pulse timing is often difficult to accurately determine. This study demonstrates that commercially available photodiodes can be used effectively for direct x-ray pulse detection without the need for visible light scintillators. X-ray pulses from four commercially available flash x-ray systems were quantified using one silicon and two indium gallium arsenide (InGaAs) photodiodes. The measured InGaAs pulse durations were strongly dependent on radiation dose in the non-linear operating regime, so the photodiodes were shielded to operate below the 2.5 V non-linear regime threshold. The average pulse duration and pulse arrival time jitter of the photodiodes for each x-ray source were within several nanoseconds with the exception of two sets of measurements that were affected by low instrument sensitivity and electrical noise. These results show that InGaAs photodiodes can be used as effective and repeatable stand-alone timing diagnostics for x-ray pulses as short as 20 ns or less.

47 OTHER INSTRUMENTATION↗

Heralded Multiplexed High-Efficiency Cascaded Source of Dual-Rail Entangled Photon Pairs Using Spontaneous Parametric Down-Conversion

Deterministic sources of high-fidelity entangled qubit pairs encoded in the dual-rail photonic basis, i.e., presence of a single photon in one of two orthogonal modes, are a key enabling technology of many applications of quantum information processing, including high-rate, high-fidelity quantum communications over long distances. The most popular and mature sources of such photonic entanglement, e.g., those that leverage spontaneous parametric down-conversion (SPDC) or spontaneous four-wave mixing, generate an entangled (so-called continuous-variable) quantum state that contains contributions from high-order photon terms that lie outside the span of the dual-rail basis, which is detrimental to most applications. One often uses low pump power to mitigate the effects of those high-order terms. However, that reduces the pair generation rate, and the source becomes inherently probabilistic. We investigate a cascaded source that performs a linear-optical entanglement swap between two SPDC sources, to generate a heralded photonic entangled state that has a higher fidelity (to the ideal Bell state) compared to a free-running SPDC source. Furthermore, with the Bell swap providing a heralding trigger, we show how to build a multiplexed source, which despite reasonable switching losses and detector loss and noise, yields a fidelity versus success probability trade-off of a high-efficiency source of high-fidelity dual-rail photonic entanglement. We find, however, that there is a threshold of 1.5 dB of loss per switch, beyond which multiplexing hurts the fidelity versus success probability trade-off.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗