Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Permeameter for high-temperature magnetic measurements

A permeameter is described that measures the magnetizing force and the corresponding magnetic induction up to 1000 C. The two symmetrical yokes are made of an alloy of 9 percent iron, 91 percent cobalt. A coil surrounding the specimen supplies a magnetizing force of up to 100 oersteds. The instrument uses the magnetic potentiometer principle to cancel the effects of the reluctance of the yoke and the joint gaps. Very close agreement was obtained at room temperature when compared to an MH type permeameter. The effect of temperature on the normal induction curves for the yoke material is also presented.

Barranger, J. P.↗

The magnetic-field investigation on ISPM

The International Solar Polar Mission (ISPM) onboard instrumentation for the magnetic field experiment to establish, on the basis of in-situ observations, the heliolatitude dependence of the interplanetary magnetic field, is described. The prime output consists of vector measurements, made by two triaxial magnetometers, of the ambient magnetic field along the orbit of the spacecraft. The onboard data processor generates two data streams to be transmitted through the spacecraft telemetry. The low speed, analog data stream consists of averaged and despun vector measurements, digitized in the spacecraft analog to digital converter (ADC). The despinning algorithm used in the analog processor is described. The high speed, digital data stream consists of vector measurements digitized in the instrument ADCs, generating up to two vector samples per sec. Multiple data-path switching is used to increase system reliability and to allow cross calibration of the ADCs. On board facilities for inflight calibration are described.

Balogh, A.↗

ZEEMANS - a high magnetic

ZEEMANS, a new instrument proposed for the Spallation Neutron Source (SNS)at Oak Ridge, will provide highest available magnetic elds for neutron scattering experiments.The unique capabilities of the magnet, large size and required connection to utilities demanda versatile instrument, able of performing diraction (powder and single crystal), SANS,reectometry, and inelastic spectrometry, with minimal modications between congurations.In this paper we present preliminary design features for ZEEMANS. Monte Carlo simulationsand analytical calculations were used to study its expected performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The magnetic field investigation on the Ulysses mission - Instrumentation and preliminary scientific results

A fundamental feature of the heliosphere is the three-dimensional structure of the interplanetary magnetic field. The magnetic field investigation on Ulysses, the first space probe to explore the out-of-ecliptic and polar heliosphere, aims at determining the large-scale features and gradients of the field, as well as the heliolatitude dependence of interplanetary phenomena so far only observed near the ecliptic plane. The Ulysses magnetometer uses two sensors, one a Vector Helium Magnetometer, the other a Fluxgate Magnetometer. Onboard data processing yields measurements of the magnetic field vector with a time resolution up to 2 vectors/second and a sensitivity of about 10 pT. Since the switch-on of the instrument in flight on 25 October 1990, a steady stream of observations has been made, indicating that at this phase of the solar cycle the field is generally disturbed: several shock waves and a large number of discontinuities have been observed, as well as several periods with apparently intense wave activity. The paper gives a brief summary of the scientific objectives of the investigation, followed by a detailed description of the instrument and its characteristics. Examples of wave bursts, interplanetary shocks and crossings of the heliospheric current sheet are given to illustrate the observations made with the instrument.

Balogh, A.↗

Time-Distance Helioseismology with the HMI Instrument

We expect considerable improvement of time-distance results from the Helioseismic and Magnetic Imager (HMI) instrument as opposed to the earlier MDI and GONG data. The higher data rate makes possible several improvements, including faster temporal sampling (45 sec), smaller spatial pixels (0.5 arc sec), better wavelength coverage (6 samples across the line all transmitted to the ground), and year-round coverage of the full disk. The higher spatial resolution makes possible better longitude coverage of active regions and supergranulation and also better latitude coverage. Doppler, continuum, and line depth images have a strong granulation signal. Line core images show little granulation. Analyses to test the limits of these new capabilities will be presented.

Duvall, Thomas L., Jr.↗

A Faraday-effect polarimeter for fast magnetic dynamics measurement on DIII-D

A Faraday-effect-based radial-interferometer-polarimeter diagnostic has been developed to explore fast magnetic dynamics in high-performance DIII-D plasmas. The instrument measures radial magnetic field perturbations using three chords positioned near the magnetic axis. Newly developed solid-state sources operating at 650 GHz provide phase noise down to 0.01°/$\sqrt{kHz}$ and tunable bandwidth up to 10 MHz. Various systematic errors which can contaminate the polarimetric measurement have been investigated in detail. Distortion of circular polarization due to non-ideal optical components is calibrated using a rotating quarter wave plate technique. The impact of perpendicular magnetic field, i.e., the Cotton-Mouton effect, is evaluated. The error due to non-collinearity of probe beams is minimized to less than 0.5° for electron density up to 7 × 10 19 m -3 by alignment optimization. Optical feedback, due to multiple reflections induced by the double-pass configuration, is identified and reduced. Lastly, coherent and broadband high-frequency magnetic fluctuations for DIII-D H-mode plasmas are observed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structural and magnetic properties of La–Co substituted Sr–Ca hexaferrites synthesized by the solid state reaction method

Graphical abstract: The change of the remanence (B{sub r}) and intrinsic coercivity (H{sub cj}) with La content (x) and Co content (y) of hexagonal ferrite Sr{sub 0.7−x}Ca{sub 0.3}La{sub x}Fe{sub 12−y}Co{sub y}O{sub 19} magnets. - Highlights: • Sr{sub 0.7−x}Ca{sub 0.3}La{sub x}Fe{sub 12−y}Co{sub y}O{sub 19} hexaferrites were synthesized by the solid state reaction method. • B{sub r} continuously increases with increasing dopant contents. • H{sub cb}, H{sub cj} and (BH){sub max} for the magnets first increases and then decreases with an increase in the La–Co contents. - Abstract: Hexagonal ferrite Sr{sub 0.7−x}Ca{sub 0.3}La{sub x}Fe{sub 12−y}Co{sub y}O{sub 19} (x = 0.05–0.50; y = 0.04–0.40) magnetic powders and magnets were synthesized by the solid state reaction method. X-ray diffraction was employed to determine the phase compositions of the magnetic powders. There is a single magnetoplumbite phase in the magnetic powders with the substitution of La (0.05 ≤ x ≤ 0.15) and Co (0.04 ≤ y ≤ 0.12) contents. For the magnetic powders containing La (x ≥ 0.20) and Co (y ≥ 0.16), magnetic impurities begin to appear in the structure. A field emission scanning electron microscope was used to characterize the micrographs of the magnets. The magnets have formed hexagonal structures. Magnetic properties of the magnets were measured by a magnetic properties test instrument. The remanence continuously increases with increasing dopant contents. Whereas, the magnetic induction coercivity, intrinsic coercivity and maximum energy product for the magnets first increases and then decreases with an increase in the La–Co contents.

36 MATERIALS SCIENCE↗

Direct thrust measurement of a permanent magnet helicon double layer thruster

Direct thrust measurements of a permanent magnet helicon double layer thruster have been made using a pendulum thrust balance and a high sensitivity laser displacement sensor. At the low pressures used (0.08 Pa) an ion beam is detected downstream of the thruster exit, and a maximum thrust force of about 3 mN is measured for argon with an rf input power of about 700 W. The measured thrust is proportional to the upstream plasma density and is in good agreement with the theoretical thrust based on the maximum upstream electron pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Data Report of Hydrographic Observations: Geomagnetic Observations at the Hatizyo Hydrographic Observatory for the Year 1994

The Hatizyo Hydrographic Observatory, which is one of the essential magnetic observatories in Japan, was established in 1979 and is currently operated by the Hydrographic Department, Maritime Safety Agency. This is the annual report compiled from the results of magnetic observations carried out at the observatory in 1994. As to the instruments used for magnetic observations, the digital recording variometer was replaced by a fluxgate magnetometer in 1986, and one set each of the proton and fluxgate magnetometers was additionally installed in January and October 1992, respectively.

Source record↗

Data Report of Hydrographic Observations: Geomagnetic Observations at the Hatizyo Hydrographic Observatory for the Year 1993

The Hatizyo Hydrographic Observatory, which is one of the essential magnetic observatories in Japan, was established in 1979 and is currently operated by the Hydrographic Department, Maritime Safety Agency. This is the annual report compiled from the results of magnetic observations carried out at the observatory in 1993. As to the instruments used for magnetic observations, the digital recording variometer was replaced by a fluxgate magnetometer in 1986, and one set each of the proton and fluxgate magnetometers was additionally installed in January and October 1992, respectively.

Source record↗

The Giotto magnetic-field investigation

The objectives of the Giotto magnetometer experiment are the investigation of the interaction between Comet Halley and the solar wind 0.9 AU from the Sun, to within 500 km of the cometary nucleus, and the study of the interplanetary magnetic field. The instrumentation consists of a triaxial and a separate biaxial system of fluxgate sensors of the ring-core type, the associated analog electronics and a digital processor. The measuring ranges of + or 1 16 up to + or - 65536 nT are digitized by a 12-bit analog-to-digital converter. Memory modes allow the bridging of gaps in telemetry coverage of up to 10 days. Because of the dust hazard near closest approach, a magnetometer boom could not be included in the spacecraft design. The magnetic contamination problem was attacked by the use of two magnetometers and by a magnetic-cleanliness program. In-flight results show that the instrument is working flawlessly, though magnetic-contamination problems remain.

Neubauer, F. M.↗

Instrumentation status of the low-b magnet systems at the Large Hadron Collider (LHC)

The low-{beta} magnet systems are located in the Large Hadron Collider (LHC) insertion regions around the four interaction points. They are the key elements in the beams focusing/defocusing process allowing proton collisions at luminosity up to 10{sup 34}cm{sup -2}s{sup -1}. Those systems are a contribution of the US-LHC Accelerator project. The systems are mainly composed of the quadrupole magnets (triplets), the separation dipoles and their respective electrical feed-boxes (DFBX). The low-{beta} magnet systems operate in an environment of extreme radiation, high gradient magnetic field and high heat load to the cryogenic system due to the beam dynamic effect. Due to the severe environment, the robustness of the diagnostics is primordial for the operation of the triplets. The hardware commissioning phase of the LHC was completed in February 2010. In the sake of a safer and more user-friendly operation, several consolidations and instrumentation modifications were implemented during this commissioning phase. This paper presents the instrumentation used to optimize the engineering process and operation of the final focusing/defocusing quadrupole magnets for the first years of operation.

43 PARTICLE ACCELERATORS↗

Compact Doppler Magnetograph

Here we present a design for a high-performance, compact, low-cost flight instrument that measures velocity and magnetic fields on the photospere. This instrument is called the Compact Doppler Magnetograph, or CDM, and is based on the magneto-optical filter invented by A. Cacciani.

Doppler↗

Ion composition of the bulk ring current during a magnetic storm - Observations with the CHEM-instrument on AMPTE-CCE

Ion composition measurements in the entire energy range of the ring current population, obtained with the Charge-, Energy-, Mass-spectrometer instrument on the Charge Composition Explorer in September 1984, are reported. From the energy spectra obtained for all major constituents during the main phase of a magnetic storm, the number densities, energy densities, and mean energies are calculated and displayed as radial profiles. The mean energies of He(2+) are found to be about twice that of H(+) and He(+) throughout this storm, and the time profiles for the mean energies of all major ions are seen to bunch together (when normalizing mean energies by the ionic charge), with the largest variations of the energy densities and mean energies occurring for O(+) ions.

Stuedemann, W.↗

Magnetoelastics of a spin liquid : x-ray diffraction studies of Tb{sub 2}Ti{sub 2}O{sub 7} in pulsed magnetic fields.

We report high resolution single crystal x-ray diffraction measurements of the frustrated pyrochlore magnet Tb{sub 2}Ti{sub 2}O{sub 7}, collected using a novel low temperature pulsed magnet system. This instrument allows characterization of structural degrees of freedom to temperatures as low as 4.4 K, and in applied magnetic fields as large as 30 T. We show that Tb{sub 2}Ti{sub 2}O{sub 7} manifests intriguing structural effects under the application of magnetic fields, including strongly anisotropic giant magnetostriction, a restoration of perfect pyrochlore symmetry in low magnetic fields, and ultimately a structural phase transition in high magnetic fields. It is suggested that the magnetoelastic coupling thus revealed plays a significant role in the spin liquid physics of Tb{sub 2}Ti{sub 2}O{sub 7} at low temperatures.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SAMPEX mission overview

The Solar, Anomalous, and Magnetospheric Particle Explorer SAMPEX will carry out energetic particle studies of outstanding scientific questions in the fields of space plasma physics, solar physics, magnetospheric and middle atmospheric physics, and cosmic ray physics. SAMPEX will measure the electron and ion composition of energetic particle populations from about 0.4 MeV/nucleon to hundreds of MeV/nucleon from a zenith-pointing small satellite in near-polar orbit. While over the magnetic poles, the instruments will study the composition of anomalous cosmic rays, solar energetic particles, and Galactic cosmic rays. At lower magnetic latitudes, geomagnetic cutoff effects will allow determination of the ionization state of these particles at energies much higher than can be studied from interplanetary spacecraft. At subauroral latitudes, SAMPEX will also observe precipitating relativistic magnetospheric electrons, which undergo important intertactions within the middle atmosphere.

Mason, G. M.↗

Crosstalk in solar polarization measurements

The instrumental crosstalk associated with the Marshall Space Flight Center Vector Magnetograph and the solar crosstalk created by the magnetic field are described and their impact on the reconstruction of the solar vector magnetic field is analyzed. It is pointed out that identifying and correcting the crosstalk is important in the development of realistic models describing the solar atmosphere. Solar crosstalk is spatially dependent on the structure of the magnetic field while instrumental crosstalk is dependent on the position of the analyzer.

West, E. A.↗