The paleomagnetic record in carbonaceous chondrites - Natural remanence and magnetic properties

Recent results of an intensive study of the natural remanence (NRM) and the magnetic properties of carbonaceous chondrites (CC) are summarized. It is convincingly demonstrated that the record of ancient magnetic fields has been preserved in these least-altered old samples of solar system material known. Intensities of specific NRM in the 13 meteorites surveyed span a broad range of values from 0.00005 to 0.5 emu/g. A low-temperature cleaning technique, based on the memory effect in magnetite grains, was followed by alternating field (af) demagnetization of the residual memory to exhibit the relative stability of NRM in the CC studied. No systematic correlation was found of either intensity or stability of NRM to af demagnetization with petrologic subtype, beyond a trend of increasing stability of memory from petrologic subtype C2 to subtype C4. The intensity and stability behavior of the saturation remanence are better suited for use in a magnetic classification of CC.

Brecher, A.↗

Magnetic stress anisotropy field in plated cylindrical Permalloy films.

An analysis is made of the magnetic stress anisotropy field (Hks) arising from internal and external stress sources in plated-wire memory elements. The analysis takes into consideration circumferential composition variation and cylindrical geometry of the Permalloy film. Expressions are derived relating Hks to uniaxial film stress, average composition, and amplitude of composition variation. A result of particular importance is that even for average zeromagnetostrictive composition (ZMC) films, Hks may still make an appreciable contribution to the total anisotropy field if the composition is not uniform. Calculated Hks characteristics are shown to correlate with anisotropy field changes observed in annealing experiments. Examples are given to show the importance of composition uniformity in determining the stability of the anisotropy field. The utility of the analysis is extended by the inclusion of data expressing the inverse relation between anisotropy field and easy-axis dispersion in the film.

Lutes, O. S.↗

All-Metal Magnetic RAM

The factors that enter into the development of an all-metal, nonvolatile magnetic RAM, in which multilayer giant magnetoresistive films are used for all functions - storage, readout, and support electronics - are described. Four significant characteristics are expected to favor all-metal over hybrid magnetic RAM. First, silicon-technology fabrication requires a large number of masking steps, including complex ones such as ion implantation. Conversely, all-metal technology is inherently simple: fewer masking steps, no doping, scaling to lithographic limits, very little operating power. Second, the all-metal footprint is significantly smaller than the hybrid one. Third, an all-metal RAM is expected to be able to be miniaturized to lithographic limits; miniaturization of hybrid magnetic RAMs is likely to be limited by the semiconductor circuitry. Finally, semiconductor processing and magnetic processing in MRAM are done separately because the former requires high temperatures, whereas magnetic fabrication is a low-temperature process. By contrast, because both GMR electronics and the memory elements are made of the same materials, the two major components are deposited and patterned concurrently on the same substrate.

Torok, E. J.↗

Detector Apparatus and Method

Transceiver and methods are included that are especially suitable for detecting metallic materials, such as metallic mines, within an environment. The transceiver includes a digital waveform generator used to transmit a signal into the environment and a receiver that produces a digital received signal. A tracking module preferably compares an in-phase and quadrature transmitted signal with an in-phase and quadrature received signal to produce a spectral transfer function of the magnetic transceiver over a selected range of frequencies. The transceiver initially preferably creates a reference transfer function which is then stored in a memory. Subsequently measured transfer functions will vary depending on the presence of metal in the environment which was not in the environment when the reference transfer function was determined. The system may be utilized in the presence of other antennas, metal, and electronics which may comprise a plastic mine detector for detecting plastic mines. Despite the additional antennas and other metallic materials that may be in the environment due to the plastic mine detector, the magnetic transceiver remains highly sensitive to metallic material which may be located in various portions of the environment and which may be detected by sweeping the detector over ground that may contain metals or mines.

Arndt, G. Dickey↗

Design and Application of Hybrid Magnetic Field-Eddy Current Probe

The incorporation of magnetic field sensors into eddy current probes can result in novel probe designs with unique performance characteristics. One such example is a recently developed electromagnetic probe consisting of a two-channel magnetoresistive sensor with an embedded single-strand eddy current inducer. Magnetic flux leakage maps of ferrous materials are generated from the DC sensor response while high-resolution eddy current imaging is simultaneously performed at frequencies up to 5 megahertz. In this work the design and optimization of this probe will be presented, along with an application toward analysis of sensory materials with embedded ferromagnetic shape-memory alloy (FSMA) particles. The sensory material is designed to produce a paramagnetic to ferromagnetic transition in the FSMA particles under strain. Mapping of the stray magnetic field and eddy current response of the sample with the hybrid probe can thereby image locations in the structure which have experienced an overstrain condition. Numerical modeling of the probe response is performed with good agreement with experimental results.

Wincheski, Buzz↗

Quasi-perfect FIFO: Synchronous or asynchronous with application in controller design for the UNICON laser memory

The first-in-first-out memory buffer (FIFO), is an elastic digital memory whose main application is in data buffering between devices operating at different rates. Data written into the top is moved autonomously down toward the bottom of the FIFO to the lowest unoccupied location, and data read from the bottom of the FIFO will cause data from the top to move autonomously down toward the bottom. The FIFO is available in MOS LSI asynchronous form with data rate in the 1 MHz region. The FIFO described yields a simple high-speed iterative implementation, either synchronous of asynchronous. Because of this simple iterative structure, the FIFO is expandable in both number of words and bits per word, and it is attractive from the viewpoint of integrated-circuit production. For the synchronous FIFO, a model was built and successfully used in the controller for the UNICON laser memory. For the asynchronous FIFO, a model was built and also successfully used in a high-performance magnetic tape controller.

Lim, R. S.↗

Explicit IMF B(sub y)-Effect Maximizes at Subauroral Latitudes (Dedicated to the Memory of Eigil Friis-Christensen)

The most important parameter in the coupling between solar wind and geomagnetic activity is the B(sub z)‐component of the interplanetary magnetic field (IMF). However, recent studies have shown that IMF B(sub y) is an additional, independent driver of geomagnetic activity. We use here local geomagnetic indices from a large network of magnetic stations to study how IMF B(sub y) affects geomagnetic activity at different latitudes for all solar wind and, separately, during coronal mass ejections. We show that geomagnetic activity, for all solar wind, is 20% stronger for B(sub y) > 0 than for B(sub y) < 0 at subauroral latitudes of about 60° corrected geomagnetic latitude. During coronal mass ejections, the B(sub y)‐effect is larger, about 40%, at slightly lower latitudes of about 57° (corrected geomagnetic) latitude. These results highlight the importance of the IMF B(sub y)‐component for space weather at different latitudes and must be taken into account in space weather modeling

Holappa, L.↗

Capturing, Analyzing, Maintaining, and Disseminating Shape Memory Material Data Between Information Management Systems

With an increased demand on reducing the time, cost, and effort to develop new materials, Integrated Computational Materials Engineering (ICME) has received widespread attention in various engineering disciplines as a catalyst for significantly reducing experimental testing during the material design process. An ICME approach to design can enable ‘fit-for-purpose’ materials to be realized in engineering applications by incorporating well-understood process-property-performance relationships between the various length and time scales in a material’s structure, enabling material optimization. However, such an approach requires validated multiscale models at the various length scales for a material, which in turn requires a large amount of data, a robust means of storing the data, and the ability to link data to developed material models. The NASA Vision 2040 [1] has identified nine key elements to enabling ICME approaches in system level design, with one being “Data, Information, and Visualization”, thus outlining the importance of a robust information management system for ICME. As the relationship between microstructure, properties, and material performance become better understood and incorporated into multiscale models that can be leveraged in application design, the emergence of new materials with application-driven properties can be realized. One such new material class that has seen growing attention are shape memory materials (SMM), in which a material can transition between a deformed and undeformed state via a reversible phase transformation when subject to a thermal, mechanical, or magnetic load [2]. SMMs have been used widely in aerospace and biomedical industries, including applications such as actuators, low-shock mechanisms, medical staples, braces, and stents [3, 4]. These materials exhibit unique behavior due to their ability to transition between phases, and thus the mechanisms that enable this transition must be captured in a data information management system and incorporated into SMM material models. At NASA Glenn Research Center, the Shape Memory Materials Database (SMMD) Tool has been developed to capture the necessary information that governs SMM material behavior and provide users the ability to select and visualize various SMMs for a specific application [5]. The database contains point-wise data for published SMM materials, along with the pedigree metadata for traceability necessary for a robust information management system. The database is also capable of storing in-house test data performed at NASA GRC by interacting with the developed Shape Memory Alloy (SMA) Analytics tool to extract the necessary point-wise values and populate the database. Although the SMMD Tool offers its users a single, authoritative source for SMM material data that is critical for model development and material design, the full material pedigree of the in-house test data for SMMs is not currently captured and is out of the scope for the SMMD tool. In this work, the schema for capturing SMM test data within the larger NASA GRC ICME Schema [6, 7, 8, 9] will be developed and implemented for thermomechanical tests conducted at NASA GRC. The developed schema will not only store the relevant data needed for the SMMD tool, but also the material pedigree (i.e., production of the bulk material, bulk material analysis, sample cut-out diagrams, sample fabrication procedure, etc.), test pedigree (i.e., test equipment used, measurement systems used, raw test data), and analysis pedigree (i.e., how the data in the SMMD tool is calculated). Furthermore, a Python-based framework will be developed to seamlessly interact between the SMA Analytics and SMMD tools, which will write the full dataset and associated metadata to the GRC Information Management System before passing the required point-wise data to the SMMD tool. Data informatics is a key element of the NASA Vision 2040, which requires not only that data is stored and maintained throughout the material lifecycle, but that the data is also accessible and reusable such that material development efforts can be minimized. Therefore, for an ICME design approach to be realized, a centralized information management system that drives the ICME process must be able to communicate with other databases. The work that will be presented in this presentation will therefore not only demonstrate the ability of NASA GRC’s information management system to capture SMM data, but also its ability to interact with pre-existing tools specialized for such materials.

Data management↗

Preliminary design for a standard 10 sup 7 bit Solid State Memory (SSM)

A modular concept with three separate modules roughly separating bubble domain technology, control logic technology, and power supply technology was employed. These modules were respectively the standard memory module (SMM), the data control unit (DCU), and power supply module (PSM). The storage medium was provided by bubble domain chips organized into memory cells. These cells and the circuitry for parallel data access to the cells make up the SMM. The DCU provides a flexible serial data interface to the SMM. The PSM provides adequate power to enable one DCU and one SMM to operate simultaneously at the maximum data rate. The SSM was designed to handle asynchronous data rates from dc to 1.024 Mbs with a bit error rate less than 1 error in 10 to the eight power bits. Two versions of the SSM, a serial data memory and a dual parallel data memory were specified using the standard modules. The SSM specification includes requirements for radiation hardness, temperature and mechanical environments, dc magnetic field emission and susceptibility, electromagnetic compatibility, and reliability.

Hayes, P. J.↗

A solid state data recorder for spacecraft telemetry applications

A solid state data recorder (SSDR) has been developed which offers a high-reliability alternative to tape recorders in many spacecraft telemetry applications. The storage medium used in this recorder was ferrimagnetic garnet films supporting nonvolatile magnetic bubble domains. The recorder was designed using modular construction consisting of a digital control unit, power supply, and two memory modules. A prototype SSDR has been fabricated which is designed for 100-million bits of storage but was populated with 128 chips for a 13-million bit capacity. Preliminary tests indicate satisfactory operation.

Stermer, R. L., Jr.↗

The Giotto magnetic-field investigation

The objectives of the Giotto magnetometer experiment are the investigation of the interaction between Comet Halley and the solar wind 0.9 AU from the Sun, to within 500 km of the cometary nucleus, and the study of the interplanetary magnetic field. The instrumentation consists of a triaxial and a separate biaxial system of fluxgate sensors of the ring-core type, the associated analog electronics and a digital processor. The measuring ranges of + or 1 16 up to + or - 65536 nT are digitized by a 12-bit analog-to-digital converter. Memory modes allow the bridging of gaps in telemetry coverage of up to 10 days. Because of the dust hazard near closest approach, a magnetometer boom could not be included in the spacecraft design. The magnetic contamination problem was attacked by the use of two magnetometers and by a magnetic-cleanliness program. In-flight results show that the instrument is working flawlessly, though magnetic-contamination problems remain.

Neubauer, F. M.↗

Effect of Graphene Addition on Shape Memory Behavior of Epoxy Resins

Shape memory polymers (SMPs) and composites are a special class of smart materials known for their ability to change size and shape upon exposure to an external stimulus (e.g. light, heat, pH, or magnetic field). These materials are commonly used for biomedical applications; however, recent attempts have been made towards developing SMPs and composites for use in aircraft and space applications. Implementing SMPs and composites to create a shape change effect in some aircraft structures could potentially reduce drag, decrease fuel consumption, and improve engine performance. This paper discusses the development of suitable materials to use in morphing aircraft structures. Thermally responsive epoxy SMPs and nanocomposites were developed and the shape memory behavior and thermo-mechanical properties were studied. Overall, preliminary results from dynamic mechanical analysis (DMA) showed that thermally actuated shape memory epoxies and nanocomposites possessed Tgs near approximately 168 C. When graphene nanofiller was added, the storage modulus and crosslinking density decreased. On the other hand, the addition of graphene enhanced the recovery behavior of the shape memory nanocomposites. It was assumed that the addition of graphene improved shape memory recovery by reducing the crosslinking density and increasing the elasticity of the nanocomposites.

Williams, Tiffany↗

The automation of the stellar proper motion survey

A microdensitometer, scanning pairs of star plates of identical areas of the sky taken a decade apart, is coupled to a magnetic tape unit through a data acquisition system. This system performs an image density threshold level selection for each plate and a buffer memory system to smooth the data flow as well as analog and digital display controls. The data from the tape are processed later by a large scale high speed computer which reconstructs the scanned images, discovers, measures, and documents stellar proper motions by precise comparison of corresponding areas of the two star plates to detect those images which have moved at least 0.10 seconds annually in the time interval between the exposures.

Newcomb, J. S.↗

First-Generation Jet Propulsion Laboratory "Hockey-Puck" Free-Flying Magnetometers for Distributed In-Situ Multiprobe Measurement of Current Density Filamentation in the Northern Auroral Zone: Enstrophy Mission

The sub-orbital rocket mission was a collaborative project between the University of New Hampshire, Cornell University, and the Jet Propulsion Laboratory (JPL) to study filamentation phenomena in the northern Auroral zone. The Enstrophy mission test flies the JPL Free-Flying Magnetometer (FFM) concept. The FFM technology development task has been funded by NASA develop miniaturized, low-power, integrated "sensorcrafts". JPL's role was to design, integrate, test, and deliver four FFMs for deployment from the sounding rocket, allowing a unique determination of curl-B. This provides a direct measurement of magnetic-field-aligned current density along the rocket trajectory. A miniaturized three-axis fluxgate magnetometer was integrated with a 4-channel 22-bit sigma-delta Analog to Digital Converter (ADC), four temperature sensors, digital control electronics, seven (Li-SOCl2) batteries, two (4 deg x 170 deg field of view) sun-sensors, a fan-shaped-beam laser diode beacon, a (16 MHz) stable Temperature Compensated Crystal Oscillator (TCXO) clock, Radio Frequency (RF) communication subsystem, and an antenna for approximately 15 minutes of operation where data was collected continuously and transmitted in three (3) bursts (approximately 26 seconds each) to ground station antennas at Poker Flat, Alaska. FFMs were stowed within two trays onboard the rocket during the rocket launch and were released simultaneously using the spinning action of the rocket at approximately 300 km altitude (approximately 100 sec. into the flight). FFMs were deployed with spin rate of approximately 17 Hz and approximately 3 m/sec linear velocity with respect to the rocket. For testing purposes while the rocket was in the launch pad and during flight prior to release of FFMs from the rocket, commands (such as "power on", "test", "flight", "power off', and clock "Reset" signal) were transmitted via a infrared Light Emitting Diode to an infrared detector in the FFM. Special attention was paid to low magnetic signature electronic design and choice of materials in packaging. The miniaturized fluxgate magnetometers had a range of 1-60000 nT with 0.1% full-scale linearity. The frequency range of interest for magnetic measurement was 10 mHz - 50 Hz. Digital data from the magnetometer's three axes were placed in a 4MB Static Random Access Memory (SRAM) in data packages (frames) formatted together with time tags and frame ID. After a specified time was elapsed, the data were Viterbi encoded and transmitted at a rate of 100 kbps (BPSK). Each of the four FFMs transmitted at different frequency. These carrier frequencies were in the range of 2200-2300 MHz. The antenna was a single patch on a high dielectric constant substrate covering one end-plate of the hockey-puck-sized unit. The local clocks aboard the FFMs were reset at the start of the mission and stayed synchronized within 3 msec during the mission. Position of each FFM with respect to the rocket is calculated by the knowledge of its release velocity (measured at exit point of the FFM launcher tract) providing an accuracy of 1 m over the maximum range of 3 km. Spatial and temporal nature of observants can be separated to within 3 m in space or 3 msec time interval.

Javadi, H.↗

TPSAS-NF1676L-13664-DND

The safety of aerospace vehicles is largely dependent on the ability of modern non-destructive evaluation (NDE) tools to accurately detect structural damage before a critical flaw size is reached. However, existing NDE technologies are inherently limited by the physical response of the materials being inspected making the detection of small cracks or pre-crack damage difficult. One innovative solution to this problem is to create a multifunctional metallic material that can be used in structural applications and contains second phase sensory particles that significantly enhance the ability of conventional NDE techniques to detect incipient damage during use and at regularly scheduled inspections. Ferromagnetic shape-memory alloys (FSMAs) are an ideal material for use as this second phase material as they undergo a uniform and repeatable change in both magnetic properties and crystallographic structure when strained. These changes are more readily detected than small cracks, thereby, allowing for enhanced detection of damage by conventional NDE techniques. In this study, a multifunctional metallic material was produced by embedding the sensory material particles within an aluminum alloy to form a sensory alloy. The NDE response of the FSMA and the sensory alloy during tension/compression and fatigue loading have been investigated. These results suggest that sensory alloys can be utilized for improved on-board structural health monitoring and to improve the accuracy and reduce time for ground-based inspection.

T. A. Wallace↗

Deblurring

In most instances, traditional EEG methodology provides insufficient spatial detail to identify relationships between brain electrical events and structures and functions visualized by magnetic resonance imaging or positron emission tomography. This article describes a method called Deblurring for increasing the spatial detail of the EEG and for fusing neurophysiologic and neuroanatomic data. Deblurring estimates potentials near the outer convexity of the cortex using a realistic finite element model of the structure of a subject's head determined from their magnetic resonance images. Deblurring is not a source localization technique and thus makes no assumptions about the number or type of generator sources. The validity of Deblurring has been initially tested by comparing deblurred data with potentials measured with subdural grid recordings. Results suggest that deblurred topographic maps, registered with a subject's magnetic resonance imaging and rendered in three dimensions, provide better spatial detail than has heretofore been obtained with scalp EEG recordings. Example results are presented from research studies of somatosensory stimulation, movement, language, attention and working memory. Deblurred ictal EEG data are also presented, indicating that this technique may have future clinical application as an aid to seizure localization and surgical planning.

Non-NASA Center↗

A New Concept for Non-Volatile Memory: The Electric-Pulse Induced Resistive Change Effect in Colossal Magnetoresistive Thin Films

A novel electric pulse-induced resistive change (EPIR) effect has been found in thin film colossal magnetoresistive (CMR) materials, and has shown promise for the development of resistive, nonvolatile memory. The EPIR effect is induced by the application of low voltage (< 4 V) and short duration (< 20 ns) electrical pulses across a thin film sample of a CMR material at room temperature and under no applied magnetic field. The pulse can directly either increase or decrease the resistance of the thin film sample depending on pulse polarity. The sample resistance change has been shown to be over two orders of magnitude, and is nonvolatile after pulsing. The sample resistance can also be changed through multiple levels - as many as 50 have been shown. Such a device can provide a way for the development of a new kind of nonvolatile multiple-valued memory with high density, fast write/read speed, low power-consumption, and potential high radiation-hardness.

Liu, S. Q.↗

MEMS Memory Elements

This paper presents a design example that illustrates the potential of microelectromechanical systems (MEMS) to perform the mechanical positioning required for addressing stored data and to enable an entirely new mechanism for reading and writing magnetic data. Specifically, MEMS sensors and actuators can be used to achieve active servo control of the separation between magnetic probe tips and a media surface with sub-nanometer accuracy. This allows mechanical position to be used to selectively write magnetic marks in a continuous thin-film magnetic media. In addition, MEMS sensors can be used to measure the separation between a magnetic probe tip and the media with a noise floor of roughly 22 picometers, allowing them to be used as position sensors in a magnetic force microscope (MFM) style data detection system.

Carley, L. Richard↗