Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROBALANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Rapid quenching effects in glassy polymers

Using a specially constructed microbalance for hydrostatic weighing, density changes in PVC thin film due to rapid quenching through the glass transition temperature were observed. The more severe the quench, the greater the free volume content. Isobaric volume recovery of PVC was also studied by volume dilatometry. Both show aging of relaxing molecular rearrangements taking place as a linear function of logarithmic aging time at room temperature. Distribution of retardation times and Primak's distributed activation energy spectra were applied to the volume recovery data. The concomitant changes in mechanical properties of PVC after quenching were monitored by tensile creep stress-stran to failure rates. All reflect the presence of excess free volume content due to rapid quenching.

Mcgarry, F. J.↗

Rapid quenching effects in PVC films

Using a specially constructed microbalance for hydrostatic weighing, density changes in PVC thin films (with no additives, 30-100 micrometers thick), due to rapid quenching (approximately 300 C/sec) through the glass transition temperature, have been observed. The more severe the quench, the greater is the free volume content. Isobaric volume recovery of PVC has also been studied by volume dilatometry. Both show aging of relaxing molecular rearrangements takes place as a linear function of logarithmic aging time at room temperature. Distribution of retardation times and Primak's distributed activation energy spectra have been applied to the volume recovery data. The concomitant changes in mechanical properties of PVC after quenching have been monitored by tensile creep and stress-strain to failure. All reflect the presence of excess free volume content, due to rapid quenching.

Lee, H. D.↗

Measuring the spacecraft and environmental interactions of the 8-cm mercury ion thrusters on the P80-1 mission

The subject interface measurements are described for the Ion Auxiliary Propulsion System (IAPS) flight test of two 8-cm thrusters. The diagnostic devices and the effects to be measured include: 1) quartz crystal microbalances to detect nonvolatile deposition due to thruster operation; 2) warm and cold solar cell monitors for nonvolatile and volatile (mercury) deposition; 3) retarding potential ion collectors to characterize the low energy thruster ionic efflux; and 4) a probe to measure the spacecraft potential and thruster generated electron currents to biased spacecraft surfaces. The diagnostics will also assess space environmental interactions of the spacecraft and thrusters. The diagnostic data will characterize mercury thruster interfaces and provide data useful for future applications.

Power, J. L.↗

Carbon catalyzed SO2 oxidation by NO2 and O3

The oxidation of SO2 to sulfate on carbon particles by trace quantities of NO2 and O3 was studied. Particulate carbon black was either: (1) directly exposed on the pan of a microbalance to various humidified mixtures of SO2 and oxidant gas and the resultant weight gains monitored, or (2) the gas mixtures were bubbled through aqueous suspensions of carbon black and pure water blanks. In each set of experiments the run times were varied appropriately and the yields of sulfate were determined analytically. Conversion of SO2 to sulfate was thus characterized as a function of exposure time and of oxidant gas. Carbon black was determined to be an excellent catalyst for SO2 oxidation to sulfate by both NO2 and O3. No saturation effects were observed in either experimental approach. Conversions of SO2 to sulfate did not appear pH dependent.

Cofer, W. R., III↗

OSS-1/contamination monitor

A 20-cm high, 18-cm wide, and 30-cm long (8x7x12 inch) box weighing about 7 kg (15 lbs) and consuming about 7 watts of power was carried on the OSS-1 pallet to monitor the mass build-up or accretion of condensible, volatile materials on surfaces in the shuttle bay during all phases of ascent, on-orbit, and descent. Passively thermally controlled, the box holds two witness samples and four actively temperature controlled quartz crystal microbalances (TQCM) whose temperature can vary from -60 C to +80 C. Graphs show the accretion indicated by the TQCM during the launch and early orbital phase. Conditions during tail to the Sun, nose to the Sun, and bay to the Sun attitudes of the shuttle during STS-3 are reflected in temperatures indicated by the OSS-1 thermistor. These temperatures influence outgassing rates of various materials as well as measurements made by the contamination monitor package. The parameters that bear on TQCM measurements data are shown in graphs and discussed.

Kruger, R.↗

Results from a 'small box' realtime molecular contamination monitor on STS-3

On the basis of early estimates of the Shuttle induced environment, Scialdone (1979) concluded that in the vicinity of the cargo, the cargo would have the largest influence on the environment. As a contamination control device, realtime monitors can indicate safe operational periods for sensitive attached payloads. It was, therefore, decided to develop the OSS-1/Contamination Monitor Package (CMP) experiment which was seen as a forerunner of an operational monitor. A description of the CMP is provided, taking into account four actively temperature controlled quartz crystal microbalances (TQCM). The TQCM temperatures could be varied from -60 C to +80 C. The sensor consisted of a matched pair of quartz crystals. The crystals were designated as a sensor and reference crystal. Results obtained during the STS-3 mission are discussed. These results show the feasibility and advantages of a small real-time contamination monitor.

Triolo, J.↗

Investigation of critical surface degradation effects on coatings and solar cells developed in Germany (S1002)

Various coatings developed in the FRG (i.e., second-surface mirrors with interference filters with and without conductive layers, conductive layers on solar-cell covers, and selective absorber coatings) have been qualified by accelerated tests under simulated space environment conditions. Experiments with coatings and solar cells have shown, however, that the thermo-optical behavior can differ considerably when performed on the ground and in space because of the great difficulty in simulating the space environment realistically. The objective of this experiment is to qualify these coatings under realistic space environment conditions. In addition, the experiment will provide design criteria, techniques, and test methods to insure control of the combined space and spacecraft environment effects, such as contamination, electrical conductance, and optical degradation, on the coatings. Data to be measured include the temperature of the samples, the electrical resistance of the conductive layers of the samples, the short circuit current of the solar-cell modules, and the deposition of contaminants on the samples (using quartz crystal microbalances (QCM's)).

Preuss, L.↗

Space simulation testing of the Earth Radiation Budget Satellite (ERBS)

The Earth radiation budget components and dynamics and the interactions of this energy cycle, which influences our climate were investigated. The satellite package was subjected to space simulation testing. The size of the spacecraft dictated that the testing be conducted in the new BRUTUS Thermal Vacuum Facility. Computer aided control (CAC), quartz crystal microbalance (QCM), and residual gas analysis (RGA) monitoring are combined with rigid contamination control procedures to protect the flight hardware from anomalous and potentially destructive out of scope test environments.

Magette, E.↗

Preparation and cleanliness verifications of a space simulation chamber for contamination sensitive test specimens

Contamination sensitive optical devices were to be evaluated under thermal vacuum conditions. Test specifications called for an extremely clean chamber environment, ambient temperature chamber walls, and optical surface temperatures at approximately - 30 C. Chamber preparation included the replacement of diffusion pumps with cryopumps and the cleaning of the chamber walls to reduce contamination levels. Chamber cleaning using vacuum bake was tried and abandoned as time consuming and ineffective. Chemical cleaning and cleanliness verification methods were developed. Gas chromatograph analysis techniques were used extensively throughout the cleaning process to verify cleanliness levels prior to evacuating the chamber. A chamber cleanliness verification test using a thermoelectric quartz crystal microbalance and witness samples was performed to demonstrate that an appropriate cleanliness level was achieved.

Koch, W. R.↗

Contamination Measurements During Ius Thermal Vacuum Tests in A Large Space Chamber

The levels of contamination that originate from inside the IUS equipment support section (ESS) due to outgassing from electronics components and wiring operating at elevated temperatures (80-160 F) were investigated. Pressure was measured inside and outside the ESS. Mass deposition measurements were made with quartz crystal microbalances (QCM) facing into and away from ESS vents. The OCM's were operated at -50 C and -180 C using thermoelectrically and cryogenically cooled QCM's. Gaseous nitrogen flow inside the ESS was used to obtain the effective molecular flow vent area of the ESS, which was evaluated to be 359 sq cm (56 sq in) compared to the 978 sq cm (150 sq in) estimated by an earlier atmosphere pressure billowing test. The total outgassing rate of the ESS materials at a temperature of 60 C (140 F) decays with a time constant of 11.5 hours based on pressure measurements during the hot cycle. A time constant of 22 hours was estimated for the fraction of the outgassing which will condense on a -50 C surface. In contrast, the time constant is only 10.1 hours for the outgassing material which condenses on a surface at -180 C. A surface at -180 C collects approximately one half of the material vented from the ESS which impinges on it. Pressure measurements show very good correlation with the mass deposition measurements.

C R Mullen↗

Spacecraft contamination environment; Proceedings of the Meeting, Arlington, VA, May 4-6, 1982

Aspects of IECM debriefing are considered, taking into account preliminary results of the induced environment contamination monitor measurements of STS-2, the humidity monitor and dew point hygrometer, the induced environment contamination monitor cascade impactor, the optical effects module and passive sample array, temperature-controlled quartz crystal microbalance measurements on STS-2, camera/photometer results, the mass spectrometer, and a summary regarding the induced environment contamination monitor/space transport system. Other subjects explored are related to contamination management and control, contamination/optical degradation, and contamination assessments and measurements. Attention is given to approaches for controlling contamination before launch, the coronagraph as the ultimate device to monitor orbiting particulates in the Space Transport System environment, and the contamination sensitivity of typical mirror coatings.

Maag, C. R.↗

Induced environment contamination monitor (IECM) cascade impactor

The Cascade Impactor on the IECM is an aerosol sampling instrument which employs three cascade impaction-type nozzles of progressively smaller diameter. The considered approach makes it possible to achieve particle size discrimination involving three ranges (5 microns and larger, 1 to 5 microns, and 0.3 to 1 micron). In addition to the particulate measuring cascade stages, a fourth quartz crystal microbalance measures the cumulative airborne molecular nonvolatile residue (NVR) at ambient temperature. The cascade measurements provide a temporal record of the payload bay's particulate environment during ascent, descent, and immediate postlanding periods. The NVR stage functions throughout the mission. Particulates of a size greater than five microns in diameter were below 10 micrograms per cu m throughout the mission.

Duncan, B. J.↗

The appearance of carbon aerosol particles in the lower stratosphere

Very small carbonaceous particles, thought to be meteoritic, have been found in small quantities in the lower stratosphere during aircraft sampling flights. The sampling was accomplished using a quartz crystal microbalance (QCM) cascade impactor operating on a U-2 aircraft as it flew stratospheric sampling missions. Post flight analyses of the samples using scanning electron microscopy, X-ray energy spectroscopy and Auger electron spectroscopy have identified carbon particles 0.1 micron aerodynamic diameter and smaller in 16 of 28 sets of samples obtained between 1979 and 1983. The presence of such carbon particles in the stratosphere has implications relating to global climate, to the conversion of SO2 to sulfuric acid, and to the phenomenon of the Arctic haze.

Chuan, R. L.↗

Advanced smoke meter development survey and analysis

Ideal smoke meter characteristics are determined to provide a basis for evaluation of candidate systems. Five promising techniques are analyzed in detail to evaluate compilance with the practical smoke meter requirements. Four of the smoke measurement concepts are optical methods: Modulated Transmission (MODTRAN), Cross Beam Absorption Counter (CBAC), Laser Induced Incandescence (LIN), and Photoacoustic Spectroscopy (PAS). A rapid response filter instrument called a Taper Element Oscillating Microbalance (TEOM) is also evaluated. For each technique, the theoretical principles are described, the expected performance is determined, and the advantages and disadvantages are discussed The expected performance is evaluated against each of the smoke meter specifications, and the key questions for further study are given. The most promising smoke meter technique analyzed was MODTRAN, which is a variation on a direct transmission measurement. The soot-laden gas is passed through a transmission cell, and the gas pressure is modulated by a speaker.

Pitz, R. W.↗

Sulfur dioxide and particles in quiescent volcanic plumes from Poas, Arenal, and Colima volcanos, Costa Rica and Mexico

Measurements of SO2 emission rates and concentrations and of particle distribution, size, shape, and composition were made in quiescent volcanic plumes emitted into the troposphere from Poas and Arenal volcanos, Costa Rica, and Colima volcano, Mexico. SO2 emission rates were 700 + or - 180 metric tons per day (t/d) for Poas, 210 + or - 30 t/d for Arenal, and 320 + or - 50 t/d for Colima. The concentrations of SO2 calculated from the COSPEC/lidar data were 5-380 ppb. Concentrations of SO2 measured directly by flame photometry were 10-250 ppb. Particles collected in the plumes with a quartz crystal microbalance impactor were mostly less than 3 microns in diameter and consisted of droplets of dilute sulfur-bearing solutions and minor amounts of layer silicate particles coated with a sulfur-bearing film or crust. Total particle concentrations were 4.7 micrograms per cu.m for Poas and 18.8 micrograms per cu.m for Colima. Comparison of concentrations of SO2 in the plumes with gas samples collected at fumaroles on the ground suggests that the plumes are diluted by the atmosphere by factors of up to 100,000.

Casadevall, T. J.↗

Analysis of TQCM surface contamination adsorbed during the Spacelab I Mission

The Temperature-Controlled Quartz Crystal Microbalance (TQCM) system was flown on the Spacelab I Mission as part of the Induced Environment Contamination Monitor to monitor surface contamination (SC) in the payload bay. SC on the five sensors of the TQCM was analyzed by means of IR spectroscopy, scanning electron spectroscopy, and energy dispersive X-ray fluorescence. The amount of SC ranged from 1.4 micrograms/sq cm for the -Z sensor to 39.9 micrograms/sq cm for the +X sensor. The IR analysis showed strong CH2, CH3, and carbonyl absorption bands, indicative of ester and polyester compounds found in adhesives, plasticizers, and tape. The particulates (mostly ranging from 1 micron to 20 microns in size) were mainly composed of Mg, Al, Al2O3, and Si, and probably originated in the solid rocket firings.

Mckeown, D.↗

An analytical and experimental investigation of resistojet plumes

As a part of the electrothermal propulsion plume research program at the NASA Lewis Research Center, efforts have been initiated to analytically and experimentally investigate the plumes of resistojet thrusters. The method of G.A. Simons for the prediction of rocket exhaust plumes is developed for the resistojet. Modifications are made to the source flow equations to account for the increased effects of the relatively large nozzle boundary layer. Additionally, preliminary mass flux measurements of a laboratory resistojet using CO2 propellant at 298 K have been obtained with a cryogenically cooled quartz crystal microbalance (QCM). There is qualitative agreement between analysis and experiment, at least in terms of the overall number density shape functions in the forward flux region.

Zana, L. M.↗

Optimization of outgassing bake-out temperatures and duration of space systems

Satellite components, e.g., solar panels, were subjected to bake-out tests to model outgassing characteristics and to identify methods for minimizing the bake-out time. Bake-out removes gases and particulates that are trapped at the surfaces of components during manufacture, storage, transit and handling. The tests covered temperatures from 45-85 C for up to 200 hr. Measurements of the mass loss rates were used to model the process as a function of the temperature, time and mass. Data sampling with a quartz crystal microbalance was found to be an effective means for ascertaining the mass loss rate and the activation energy of the release. The tests showed that the duration of the bake-out depends on the amount of material which must be removed and the type of outgassing which occurs. Materials which are resistant to high temperatures can be baked at the highest feasible temperatures to accelerate the outgassing process.

John Scialdone↗