Search NASA⌕ Search

SEARCH · Search NASA

Results for “MICROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Influence of Surface Preparation on Scanning Kelvin Probe Microscopy and Electron Backscatter Diffraction Analysis of Cross Sections of CdTe/CdS Solar Cells: Preprint

In this work we investigated different methods to prepare cross sections of CdTe/CdS solar cells for EBSD and SKPM analyses. We observed that procedures used to prepare surfaces for EBSD are not suitable to prepare cross sections, and we were able to develop a process using polishing and ion-beam milling. This process resulted in very good results and allowed us to reveal important aspects of thecross section of the CdTe film. For SKPM, polishing and a light ion-beam milling resulted in cross sections that provided good data. We were able to observe the depletion region on the CdTe film and the p-n junction as well as the interdiffusion layer between CdTe and CdS. However, preparing good-quality cross sections for SKPM is not a reproducible process, and artifacts are often observed.

14 SOLAR ENERGY↗

Cryo-electron microscopy and single molecule fluorescent microscopy detect CD4 receptor induced HIV size expansion prior to cell entry

Viruses are often thought to have static structure, and they only remodel after the viruses have entered target cells. Here, we detected a size expansion of virus particles prior to viral entry using cryo-electron microscopy (cryo-EM) and single molecule fluorescence imaging. HIV expanded both under cell-free conditions with soluble receptor CD4 (sCD4) targeting the CD4 binding site on the HIV-1 envelope protein (Env) and when HIV binds to receptor on cellular membrane. We have shown that the HIV Env is needed to facilitate receptor induced virus size expansions, showing that the ‘lynchpin’ for size expansion is highly specific. We demonstrate that the size expansion required maturation of HIV and an internal capsid core with wild type stability, suggesting that different HIV compartments are linked and are involved in remodelling. Our work reveals a previously unknown event in HIV entry, and we propose that this pre-entry priming process enables HIV particles to facilitate the subsequent steps in infection. - Highlights: • Cell free viruses are able to receive external trigger that leads to apparent size expansion. • Virus envelope and CD4 receptor engagement is the lynchpin of virus size expansion. • Internal capsid organisation can influence receptor mediated virus size expansion. • Pre-existing virus-associated lipid membrane in cell free virus can accommodate the receptor mediated virus size expansion.

60 APPLIED LIFE SCIENCES↗

Measurement of nanoscale external quantum efficiency of conjugated polymer. Fullerene solar cells by photoconductive atomic force microscopy

Photoconductive atomic force microscopy is used to investigate nanoscale incident photon-to-current efficiency spectra of polymer bulk heterojunction solar cells based on poly[2-methoxy-5-(3,7-dimethyloctyloxy)]-1,4-phenylenevinylene (MDMO-PPV) and [6,6]-phenyl-C 71 -butyric acid methyl ester (PC 71 BM) . Nanoscale external quantum efficiency reveals the complex morphology of MDMO-PPV:PC 71 BM films cast from toluene solution. Not only electron transfer from the photoexcited donor to the fullerene but also hole transfer process from photoexcited fullerene to the donor phase due to highest occupied molecular orbital offset is observed. The difference in performance between toluene and chlorobenzene-cast devices is explained by the variation in relative contributions from two charge transfer mechanisms.

14 SOLAR ENERGY↗

Direct observation of fatigue in epitaxially grown Pb(Zr,Ti)O 3 thin films using second harmonic piezoresponse force microscopy

In this study, we present a direct observation of fatigue phenomena in epitaxially grown Pb(Zr 0.2 Ti 0.8 )O 3 (PZT)thin films using second harmonic piezoresponse force microscopy (SH-PFM). We observed strong correlation between the SH-PFM amplitude and phase signals with the remnant piezoresponse at different switching cycles. The SH-PFM results indicate that the average fraction of switchable domains decreases globally and the phase delays of polarization switching differ locally. In addition, we found that the fatigue developed uniformly over the whole area without developing region-by-region suppression of switchable polarization as in polycrystalline PZTthin films.

36 MATERIALS SCIENCE↗

In situ imaging of orthoclase-aqueous solution interfaces with x-ray reflection interface microscopy

The use of x-ray reflection interface microscopy (XRIM) to image molecular-scale topography at the aqueous-solid interface, in situ, is described. Specifically, we image interfacial topography of the orthoclase-(001)-aqueous solution interface at room temperature and describe the challenges associated with in situ XRIM imaging. The measurements show that the reflectivity signal for in situ XRIM measurements is substantially smaller than that for ex situ measurements, because of both intrinsic and extrinsic factors. There is also a systematic temporal reduction in the image intensity with increasing x-ray dose, revealing that interaction of the focused x-ray beam with the orthoclase interfaces leads to interfacial perturbations, presumably in the form of surface roughening. This image fading is localized to the x-ray beam footprint, suggesting that the primary damage mechanism is initiated by photoelectrons produced by x-ray beam absorption near the substrate-electrolyte interface. Finally, the role of aqueous solution composition in controlling the sensitivity of the orthoclase surface to x-ray beam-induced effects is explored. A substantial increase in the orthoclase (001) surface stability was observed in solutions having elevated ionic strength, apparently as a result of the reduced lifetime of radiation chemistry products at these conditions.

36 MATERIALS SCIENCE↗

Elemental and magnetic sensitive imaging using x-ray excited luminescence microscopy

We demonstrate the potential of x-ray excited luminescence microscopy for full-field elemental and magnetic sensitive imaging using a commercially available optical microscope, mounted on preexisting synchrotron radiation (SR) beamline end stations. The principal components of the instrument will be described. Bench top measurements indicate that a resolution of 1 {mu}m or better is possible; this value was degraded in practice due to vibrations and/or drift in the end station and associated manipulator. X-ray energy dependent measurements performed on model solar cell materials and lithographically patterned magnetic thin film structures reveal clear elemental and magnetic signatures. The merits of the apparatus will be discussed in terms of conventional SR imaging techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Near-field microwave microscopy of high-κ oxides grown on graphene with an organic seeding layer

Near-field scanning microwave microscopy (SMM) is used for non-destructive nanoscale characterization of Al{sub 2}O{sub 3} and HfO{sub 2} films grown on epitaxial graphene on SiC by atomic layer deposition using a self-assembled perylene-3,4,9,10-tetracarboxylic dianhydride seeding layer. SMM allows imaging of buried inhomogeneities in the dielectric layer with a spatial resolution close to 100 nm. The results indicate that, while topographic features on the substrate surface cannot be eliminated as possible sites of defect nucleation, the use of a vertically heterogeneous Al{sub 2}O{sub 3}/HfO{sub 2} stack suppresses formation of large outgrowth defects in the oxide film, ultimately improving lateral uniformity of the dielectric film.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Pressure-induced densification in GeO{sub 2} glass: A transmission x-ray microscopy study

Nanoscale transmission x-ray microscopy measurements have been performed to determine the effect of pressure (P) on the volume (V) change in GeO{sub 2} glass up to 38.5 GPa. The P-V data show a continuous increase upon compression, indicating that the density-driven structural transformation is a gradual process. Over the pressure range studied, a transition is observed at approximately 10–13 GPa, where the material displays distinct compression behaviors. The pressure-induced densification that involves the coordination number change has been discussed. Using this newly developed high-pressure imaging technique with tens of nanometer resolution, we have provided a direct and unequivocal way for measuring density of amorphous materials to much higher pressures with accuracy rivaling x-ray diffraction of crystalline solids.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dual harmonic Kelvin probe force microscopy at the graphene–liquid interface

Kelvin probe force microscopy (KPFM) is a powerful technique for the determination of the contact potential difference (CPD) between an atomic force microscope tip and a sample under ambient and vacuum conditions. However, for many energy storage and conversion systems, including graphene-based electrochemical capacitors, understanding electrochemical phenomena at the solid–liquid interface is paramount. Despite the vast potential to provide fundamental insight for energy storage materials at the nanoscale, KPFM has found limited applicability in liquid environments to date. Here, using dual harmonic (DH)-KPFM, we demonstrate CPD imaging of graphene in liquid. We find good agreement with measurements performed in air, highlighting the potential of DH-KPFM to probe electrochemistry at the graphene–liquid interface.

36 MATERIALS SCIENCE↗

High-speed nanoscale characterization of dewetting via dynamic transmission electron microscopy

The dewetting of thin films can occur in either the solid or the liquid state for which different mass transport mechanisms are expected to control morphological changes. Traditionally, dewetting dynamics have been examined on time scales between several seconds to hours, and length scales ranging between nanometers and millimeters. The determination of mass transport mechanisms on the nanoscale, however, requires nanoscale spatial resolution and much shorter time scales. This study reports the high-speed observation of dewetting phenomena for kinetically constrained Ni thin films on crystalline SrTiO{sub 3} substrates. Movie-mode Dynamic Transmission Electron Microscopy (DTEM) was used for high-speed image acquisition during thin film dewetting at different temperatures. DTEM imaging confirmed that the initial stages of film agglomeration include edge retraction, hole formation, and growth. Finite element modeling was used to simulate temperature distributions within the DTEM samples after laser irradiation with different energies. For pulsed laser irradiation at 18 μJ, experimentally observed hole growth suggests that Marangoni flow dominates hole formation in the liquid nickel film. After irradiation with 13.8 μJ, however, the observations suggest that dewetting was initiated by nucleation of voids followed by hole growth through solid-state surface diffusion.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗