Search NASA⌕ Search

SEARCH · Search NASA

Results for “MM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9

Characterization of a 2-mm thick, 16x16 Cadmium-Zinc-Telluride Pixel Array

The detector under study is a 2-mm-thick, 16x16 Cadmium-Zinc-Telluride pixel array with a pixel pitch of 300 microns and inter-pixel gap of 50 microns. This detector is a precursor to that which will be used at the focal plane of the High Energy Replicated Optics (HERO) telescope currently being developed at Marshall Space Flight Center. With a telescope focal length of 6 meters, the detector needs to have a spatial resolution of around 200 microns in order to take full advantage of the HERO angular resolution. We discuss to what degree charge sharing will degrade energy resolution but will improve our spatial resolution through position interpolation. In addition, we discuss electric field modeling for this specific detector geometry and the role this mapping will play in terms of charge sharing and charge loss in the detector.

Gaskin, Jessica↗

Formations of Tethered Spacecraft as Stable Platforms for Far IR and Sub-mm Astronomy

In this paper we describe current research in tethered formations for interferometry, and a roadmap to demonstrating the required key technologies via on-ground and in-orbit testing. We propose an integrated kilometer-size tethered spacecraft formation flying concept which enables Far IR and Sub-mm astronomy observations from space. A rather general model is used to predict the dynamics, control, and estimation performance of formations of spacecraft connected by tethers in LEO and deep space. These models include the orbital and tethered formation dynamics, environmental models, and models of the formation estimator/controller/commander. Both centralized and decentralized control/sensing/estimation schemes are possible, and dynamic ranges of interest for sensing/control are described. Key component/subsystem technologies are described which need both ground-based and in-orbit demonstration prior to their utilization in precision space interferometry missions using tethered formations. Defining an orbiting formation as an ensemble of orbiting spacecraft performing a cooperative task, recent work has demonstrated the validity of the tethering the spacecraft to provide both the required formation rigidity and satisfy the formation reconfiguration needs such as interferometer baseline control. In our concept, several vehicles are connected and move along the tether, so that to reposition them the connecting tether links must vary in length. This feature enables variable and precise baseline control while the system spins around the boresight. The control architecture features an interferometer configuration composed of one central combiner spacecraft and two aligned collector spacecraft. The combiner spacecraft acts as the formation leader and is also where the centralized sensing and estimation functions reside. Some of the issues analyzed with the model are: dynamic modes of deformation of the distributed structure, architecture of the formation sensor, and sources of dynamical perturbation that need to be mitigated for precision operation in space. Examples from numerical simulation of an envisioned scenario in heliocentric orbit demonstrate the potential of the concept for space interferometry.

Quadrelli, Marco B.↗

COSMOG: Cosmology Oriented Sub-mm Modeling of Galactic Foregrounds

With upcoming missions in mid- and far-Infrared there is a need for software packages to reliably simulate the planned observations. This would help in both planning the observation and scanning strategy and in developing the concepts of the far-off missions. As this workshop demonstrated, many of the new missions are to be in the far-IR range of the electromagnetic spectrum and at the same time will map the sky with a sub-arcsec angular resolution. We present here a computer package for simulating foreground maps for the planned sub-mm and far-IR missions. such as SPECS. The package allows to study confusion limits and simulate cosmological observations for specified sky location interactively and in real time. Most of the emission at wavelengths long-ward of approximately 50 microns is dominated by Galactic cirrus and Zodiacal dust emission. Stellar emission at these wavelengths is weak and is for now neglected. Cosmological sources (distant and not-so-distant) galaxies for specified cosmologies will be added. Briefly, the steps that the algorithm goes through is described.

Kashlinsky, A.↗

Phosphocreatine kinetics at the onset of contractions in skeletal muscle of MM creatine kinase knockout mice

Phosphocreatine (PCr) depletion during isometric twitch stimulation at 5 Hz was measured by (31)P-NMR spectroscopy in gastrocnemius muscles of pentobarbital-anesthetized MM creatine kinase knockout (MMKO) vs. wild-type C57B (WT) mice. PCr depletion after 2 s of stimulation, estimated from the difference between spectra gated to times 200 ms and 140 s after 2-s bursts of contractions, was 2.2 +/- 0.6% of initial PCr in MMKO muscle vs. 9.7 +/- 1.6% in WT muscles (mean +/- SE, n = 7, P < 0.001). Initial PCr/ATP ratio and intracellular pH were not significantly different between groups, and there was no detectable change in intracellular pH or ATP in either group after 2 s. The initial difference in net PCr depletion was maintained during the first minute of continuous 5-Hz stimulation. However, there was no significant difference in the quasi-steady-state PCr level approached after 80 s (MMKO 36.1 +/- 3.5 vs. WT 35.5 +/- 4.4% of initial PCr; n = 5-6). A kinetic model of ATPase, creatine kinase, and adenylate kinase fluxes during stimulation was consistent with the observed PCr depletion in MMKO muscle after 2 s only if ADP-stimulated oxidative phosphorylation was included in the model. Taken together, the results suggest that cytoplasmic ADP more rapidly increases and oxidative phosphorylation is more rapidly activated at the onset of contractions in MMKO compared with WT muscles.

NASA Discipline Cell Biology↗

The Arizona Radio Observatory 1 mm Spectral Survey of IRC (plus)10216 and VY Canis Majoris (215-285 GHz)

A low noise (1(sigma) rms approx. 3 mK) 1. nun spectral survey (214.5-285.5 GHz) of the oxygen-rich supergiant VY Canis Majoris and the carbon-rich asymptotic giant branch star IRC +10216 has been conducted using the Arizona Radio Observatory's 10 m Submillimeter Telescope. Here the complete data set is presented. This study, carried out with a new ALMA-type receiver, marks the first continuous band scan of an O-rich circumstellar envelope, and the most sensitive survey to date of IRC +10216. In VY CMa, 130 distinct molecular lines were detected, 14 of which cannot be identified; in IRC +10216, 717 lines were observed, with 126 features remaining unidentified. In the 1 mm bands of VY CMa and IRC +10216, emission is present from 18 and 32 different chemical compounds, respectively, with 10 species common to both sources. Many narrow emission lines were observed in both circumstellar shells, arising from vibrationally excited molecules and from refractory-containing species. Line profiles in VY CMa also exhibit a variety of different shapes, caused by the complex, asymmetric outflow of this object. The survey highlights the fact that C-rich and O-rich circumstellar envelopes are chemically interesting, and both are sources of new interstellar molecules. The high number of unidentified lines and the unreliable, rest frequencies for known species such as NaCN indicate the need for additional laboratory spectroscopy studies.

Tenenbaum, E. D.↗

Design, Fabrication, and Testing of Lumped Element Kinetic inductance Detectors for 3 mm CMB Observations

Kinetic inductance detectors (KIDs) are a promising technology for low-noise, highly-multiplexible mm- and submm-wave detection. KIDs have a number of advantages over other detector technologies, which make them an appealing option in the cosmic microwave background B-mode anisotropy search, including passive frequency domain multiplexing and relatively simple fabrication, but have suffered from challenges associated with noise control. Here we describe design and fabrication of a 20-pixel prototype array of lumped element molybdenum KIDs. We show Q, frequency and temperature measurements from the array under dark conditions. We also present evidence for a double superconducting gap in molybdenum.

cosmic microwave background↗

3D Imaging with a Single-Aperture 3-mm Objective Lens: Concept, Fabrication and Test

There are many advantages to minimally invasive surgery (MIS). An endoscope is the optical system of choice by the surgeon for MIS. The smaller the incision or opening made to perform the surgery, the smaller the optical system needed. For minimally invasive neurological and skull base surgeries the openings are typically 10-mm in diameter (dime sized) or less. The largest outside diameter (OD) endoscope used is 4mm. A significant drawback to endoscopic MIS is that it only provides a monocular view of the surgical site thereby lacking depth information for the surgeon. A stereo view would provide the surgeon instantaneous depth information of the surroundings within the field of view, a significant advantage especially during brain surgery. Providing 3D imaging in an endoscopic objective lens system presents significant challenges because of the tight packaging constraints. This paper presents a promising new technique for endoscopic 3D imaging that uses a single lens system with complementary multi-bandpass filters (CMBFs), and describes the proof-of-concept demonstrations performed to date validating the technique. These demonstrations of the technique have utilized many commercial off-the-shelf (COTS) components including the ones used in the endoscope objective.

surgery↗

Sub-mm Scale Fiber Guided Deep/Vacuum Ultra-Violet Optical Source for Trapped Mercury Ion Clocks

We demonstrate the functionality of a mercury capillary lamp with a diameter in the sub-mm range and deep ultraviolet (DUV)/ vacuum ultraviolet (VUV) radiation delivery via an optical fiber integrated with the capillary. DUV spectrum control is observed by varying the fabrication parameters such as buffer gas type and pressure, capillary diameter, electrical resonator design, and temperature. We also show spectroscopic data of the 199Hg+ hyper-fine transition at 40.5GHz when applying the above fiber optical design. We present efforts toward micro-plasma generation in hollow-core photonic crystal fiber with related optical design and theoretical estimations. This new approach towards a more practical DUV optical interface could benefit trapped ion clock developments for future ultra-stable frequency reference and time-keeping applications.

lamps↗

Failure Analysis and Recovery of a 50-mm Highly Elastic Intermetallic NiTi Ball Bearing for an ISS Application

Ball bearings used inside the ISS Distillation Assembly centrifuge require superior corrosion and shock resistance to withstand acidic wastewater exposure and heavy spacecraft launch related loads. These requirements challenge conventional steel bearings and provide an ideal pathfinder application for 50-mm bore, deep-groove ball bearings made from the corrosion immune and highly elastic intermetallic material 60NiTi. During early ground testing in 2014 one 60NiTi bearing unexpectedly and catastrophically failed after operating for only 200 hr. A second bearing running on the same shaft was completely unaffected. An investigation into the root cause of the failure determined that an excessively tight press fit of the bearing outer race coupled with NiTi's relatively low elastic modulus were key contributing factors. The proposed failure mode was successfully replicated by experiment. To further corroborate the root cause theory, a successful bearing life test using improved installation practices (selective fitting) was conducted. The results show that NiTi bearings are suitable for space applications provided that care is taken to accommodate their unique material characteristics.

DellaCorte, Christopher↗

Advanced ACTPol Multichroic Polarimeter Array Fabrication Process for 150 mm Wafers

Advanced ACTPol (AdvACT) is a third-generation cosmic microwave background receiver to be deployed in 2016 on the Atacama Cosmology Telescope (ACT). Spanning five frequency bands from 25 to 280 GHz and having just over 5600 transition-edge sensor (TES) bolometers, this receiver will exhibit increased sensitivity and mapping speed compared to previously fielded ACT instruments. This paper presents the fabrication processes developed by NIST to scale to large arrays of feedhorn-coupled multichroic AlMn-based TES polarimeters on 150-mm diameter wafers. In addition to describing the streamlined fabrication process which enables high yields of densely packed detectors across larger wafers, we report the details of process improvements for sensor (AlMn) and insulator (SiN(sub x)) materials and microwave structures, and the resulting performance improvements.

Atacama Cosmology Telescope(ACT)↗

Apollo 15 Index of 70 mm Photographs

All Apollo 15 70 mm photographs to which NASA photo numbers have been assigned are described in this index. In the first section all photographs are listed in sequence by NASA photo numbers. In subsequent sections, lunar surface and lunar orbital photographs are cross-indexed. Lunar surface photographs are listed in chronological order within the following categories: SEVA and LM window photos (LM window photos were taken before, between, and after EVA's), EVA 1, EVA 2, and EVA 3. Photographs of the lunar surface taken while in lunar orbit are cross-indexed by longitude in 10 deg increments, starting with the easternmost (farside) photos, and progressing to the westernmost (nearside) photos. Within each 10 deg interval of longitude, photographs are listed sequentially by NASA photo number, not by specific longitude of the principal point of each photograph.

Source record↗

Characterization of AlMn TES Impedance, Noise, and Optical Efficiency in the First 150 mm Multichroic Array for Advanced ACTPol

The Advanced ACTPol (AdvACT) upgrade to the Atacama Cosmology Telescope features large arrays of multichroic pixels consisting of two orthogonal-polarization pairs of superconducting bolometers at two observing frequency bands. We present measurements of the detector properties and noise data in a subset of a fielded multichroic array of AlMn transition-edge sensor (TES) detectors. In this array, the distribution of critical temperature T(sub c) across detectors appears uniform at the percent level. The measured noise-equivalent power (NEP) distributions over approximately 1200 detectors are consistent with expectations. We find median NEPs of 4.0×10(exp −17) W/ √ Hz for low-band detectors and 6.2×10(exp −17) W/ √ Hz for high-band detectors under covered-window telescope test conditions with optical loading comparable to observing with precipitable water vapor approximately 0.5 mm. Lastly, we show the estimated detector optical efficiency, and demonstrate the ability to perform optical characterization over hundreds of detectors at once using a cryogenic blackbody source.

Crowley, Kevin T.↗

Highly Uniform 150 mm Diameter Multichroic Polarimeter Array Deployed for CMB Detection

The Advanced Atacama Cosmology Telescope Polarimeter is an upgraded receiver for the Atacama Cosmology Telescope, which has begun making measurements of the small angular scale polarization anisotropies in the Cosmic Microwave Background using the first of four new multichroic superconducting detector arrays. Here, we review all details of the optimization and characterization of this first array, which features 2012 AlMn transition edge sensor bolometers operating at 150 and 230 GHz. We present critical temperatures, thermal conductivities,saturation powers, time constants, and sensitivities for the array. The results show high uniformity across the 150 mm wafer and good performance in the field.

Ho, Shuay-Pwu Patty↗

Hybrid CMOS System-on-Chip / InP MMIC Systems for Deep-Space Planetary Exploration at mm-Wave and THz

This paper discusses the applicability of hybrid CMOS/InP-MMIC mm-Wave systems to remote sensing instrumentation for space exploration in Earth and Planetary science. We review the need for lower power and lighter weight instruments to accommodate the limited payload resources of exploration spacecraft, and then demonstrate how hybrid systems can address these challenges. An example hybrid CMOS-InP radiometer operating at 100 GHz is discoursed in detail including circuit & system design, interfacing and packaging techniques. Measurements are presented showing that the hybrid approach does not compromise instrument sensitivity.

Tang, Adrian↗

Total Variation Majorization Minimization (TV-MM) Approach to Radiometer Brightness Temperature Gridding and Reconstruction

This paper presents the implementation of an algorithm to enhance the image resolution of the Earth's surface brightness temperature (T B ) data measured by radiometers such as the one onboard of the Soil Moisture Active Passive (SMAP) mission. A key step in radiometer T B processing is the conversion of the swath-based calibrated antenna temperature (T A ) measurements to the Level 3 Earth-centered grid. The simplest algorithm to transform this data from swath to gridded format is called drop-in-the-bucket which simply averages surrounding noisy T A samples to form a T B value at the gridded location. This method reduces noise, however produces low resolution products. To obtain a higher resolution product, SMAP uses other techniques such the Backus-Gilbert (BG) algorithm, which is the conventional method used in microwave radiometry. Although this method performs the required interpolation, it is not effective in denoising and removing blurring effects due to antenna filtering of the radiometer image data. Our motivation for this development is to further improve the resolution through post-processing of the radiometer T B image, a highly cost-effective method of image enhancement. The approach adapted in this work is based on the minimization of the Total Variation (TV) regularized objective function that is used extensively in solving general ill-posed linear inverse problems in image processing. Since the TV-based objective function is convex but not everywhere differentiable, there exists many numerical algorithms that can estimate the solution and the one selected for this work is called Majorization- Minimization (MM). By applying this algorithm, simulation experiments were performed based on synthetic data from the Geophysical model as well as real SMAP data to demonstrate the effectiveness of the technique. Results were then compared against the BG method.

Wing Lee↗