Method for producing an atomic oxygen beam

A method for producing an atomic oxygen beam is provided by the present invention. First, a material 10' is provided which dissociates molecular oxygen and dissolves atomic oxygen into its bulk. Next, molecular oxygen is exposed to entrance surface 11' of material 10'. Next, material 10' is heated by heater 17' to facilitate the permeation of atomic oxygen through material 10' to the UHV side 12'. UHV side 12' is interfaced with an ultra-high vacuum (UHV) environment provided by UHV pump 15'. The atomic oxygen on the UHV side 12' is excited to a non-binding state by exciter 14' thus producing the release of atomic oxygen to form an atomic oxygen beam 35'.

Outlaw, Ronald A.↗

The Use of the Molecular Adsorber Coating Technology to Mitigate Vacuum Chamber Contamination During Pathfinder Testing for the James Webb Space Telescope

As a coating made of highly porous zeolite materials, the Molecular Adsorber Coating (MAC) was developed to capture outgassed molecular contaminants, such as hydrocarbons and silicones. For spaceflight applications, the adsorptive capabilities of the coating can alleviate on-orbit outgassing concerns on or near sensitive surfaces and instruments within the spacecraft. Similarly, this sprayable paint technology has proven to be significantly beneficial for ground based space applications, in particular, for vacuum chamber environments. This paper describes the recent use of the MAC technology during Pathfinder testing of the Optical Ground Support Equipment (OGSE) for the James Webb Space Telescope (JWST) at NASA Johnson Space Center (JSC). The coating was used as a mitigation tool to entrap persistent outgassed contaminants, specifically silicone based diffusion pump oil, from within JSC's cryogenic optical vacuum chamber test facility called Chamber A. This paper summarizes the sample fabrication, installation, laboratory testing, post-test chemical analysis results, and future plans for the MAC technology, which was effectively used to protect the JWST test equipment from vacuum chamber contamination.

molecular contamination↗

Nuclear pumping by the U-235 /n,ff/ FF reaction

The quenching role of the UF6 in noble gas nuclear pumped lasers is examined. Detailed results are presented for He-UF6-Xe system. These results indicate that depletion of the atomic ion is the mechanism responsible for the observed behavior. Based on this it is concluded that UF6 is not compatible with noble gas lasers but should be compatible with molecular lasers.

Hassan, H. A.↗

A molecular beam/quadrupole mass spectrometer system with synchronized beam modulation and digital waveform analysis

A performance evaluation is conducted for a molecular beam/mass spectrometer (MB/MS) system, as applied to a 1-30 torr microwave-discharge flow reactor (MWFR) used in the formation of the methylperoxy radical and a study of its subsequent destruction in the presence or absence of NO(x). The modulated MB/MS system is four-staged and differentially pumped. The results obtained by the MWFR study is illustrative of overall system performance, including digital waveform analysis; significant improvements over previous designs are noted in attainable S/N ratio, detection limit, and accuracy.

Pellett, G. L.↗

Interstellar molecules

Progress in the discovery and study of interstellar molecules is summarized. The 36 molecular species thus far identified in interstellar space are listed in several groups which include simple hydrides, oxides, and sulfides, various derivatives of ammonia, molecules involving linear carbon chains, cyanides, and molecules related in structure to formaldehyde, alcohols, or ethers. Several free radicals are described, the discovery of molecules in external galaxies is discussed, and possible mechanisms for molecular formation are noted. Methods for examining relative isotopic abundances by measuring molecules in interstellar clouds are outlined, mechanisms for the excitation of interstellar molecules are reviewed, and values are presented for the C-12/C-13 abundance ratio in a number of interstellar clouds. The detection of interstellar masers is discussed along with pumping mechanisms and masing transitions in H2CO, CH, OH, and SiO. The nature of dense interstellar clouds is examined in terms of several simple and complex cloud models, with emphasis on multiple condensation models.

Townes, C. H.↗

Fiber optic Raman thermometer for Space Shuttle main engine preburner profiling

The feasibility of combustion gas temperature measurements in the SSME fuel preburner using nonintrusive optical diagnostics was investigated. Temperature profiles are desired in the high pressure, hydrogen-rich preburner stream to evaluate designs to alleviate thermal stressing of the fuel pump turbine blades. Considering the preburner operating conditions and optical access restrictions, a spontaneous Raman backscattering system, implemented with optical fibers to couple to the combustion device, was selected as the most practical for gas temperature probing. A system is described which employs a remotely-located argon-ion laser to excite the molecular hydrogen Raman spectrum. The laser radiation is conveyed to the combustor through an optical fiber and focused through a window into the chamber by an optical head attached to the combustor. The gas temperature is determined from the distribution of rotational populations represented in the Raman spectrum.

Shirley, J. A.↗

Interacting masers and the extreme brightness of astrophysical water masers

Extreme surface brightnesses have long been reported for water masers which are well beyond what is found in self-consistent, theoretical investigations of these masers. The transport of maser radiation is calculated when two masers, having the properties inferred for the numerous weaker masers and separated by distances characteristic of the molecular cloud, are aligned to within the angular spread of the beam of maser radiation. The beam size is reduced and brightness temperatures similar to the highest observed values are readily produced. This enhanced beaming reduces the number of photons required from each maser feature to a level that can be understood within available pumping scenarios. The large number of weaker masers that have been identified in the most luminous galactic cloud of water masers (the W49 region) makes it especially plausible that alignments occur and produce the very bright masers in this region.

Deguchi, Shuji↗

Laboratory measurement of the S(9) pure rotation frequency in H2

The S(9) J = 11-9 ground-state transition in H2 is investigated experimentally, applying a 514.5-nm 300-mW single-mode CW Ar-ion laser to probe the stimulated Raman emission of a CH4-air flame pumped by a single-frequency electronically scannable dye laser amplified to 2 MW by a 10-Hz frequency-doubled Nd:YAG laser. An H2 Raman spectrum with an S(9) frequency of 2130.102 + or - 0.004/cm is shown, and the results are found to be consistent with the measurements obtained in the Orion molecular cloud by Knacke and Young (1980 and 1981).

Jennings, D. E.↗

High-power operation of highly reliable narrow stripe pseudomorphic single quantum well lasers emitting at 980 nm

Ridge waveguide pseudomorphic InGaAs/GaAs/AlGaAs single-quantum-well lasers exhibiting record high quantum efficiencies and high output power densities (105 mW per facet from a 6 micron wide stripe) at a lasing wavelength of 980 nm are discussed that were fabricated from a graded index separate confinement heterostructure grown by molecular beam epitaxy. Life testing at an output power of 30 mW per uncoated facet reveals a slow gradual degradation during the initial 500 h of operation after which the operating characteristics of the lasers become stable. The emission wavelength, the high output power, and the fundamental lateral mode operation render these lasers suitable for pumping Er3+-doped fiber amplifiers.

Larsson, A.↗

Thermal Water Vapor Emission from Shocked Regions in Orion

Using the Long Wavelength Spectrometer on board the Infrared Space Observatory, we have observed thermal water vapor emission from a roughly circular field of view approximately 75" in diameter centered on the Orion BN-KL region. The Fabry-Perot line strengths, line widths, and spectral line shifts observed in eight transitions between 71 and 125 micron show good agreement with models of thermal emission arising from a molecular cloud subjected to a magnetohydrodynamic C-type shock. Both the breadth and the relative strengths of the observed lines argue for emission from a shock rather than from warm quiescent gas in the Orion core. Although one of the eight transitions appears anomalously strong and may be subject to the effects of radiative pumping, the other seven indicate an H2O/H2 abundance ratio on the order of 5 x 10(exp -4) and a corresponding gas-phase oxygen-to-hydrogen abundance ratio on the order of 4 x 10(exp -4). Given current estimates of the interstellar, gas-phase, oxygen and carbon abundances in the solar vicinity, this value is consistent with theoretical shock models that predict the conversion into water of all the gas-phase oxygen that is not bound as CO. The overall cooling provided by rotational transitions of H2O in this region appears to be comparable to the cooling through rotational lines of CO but is an order of magnitude lower than cooling through H2 emission. However, the model that best fits our observations shows cooling by H2O and CO dominant in that portion of the postshock region where temperatures are below approximately 800 K and neither vibrational nor rotational radiative cooling by H2 is appreciable.

Harwitt, Martin↗

Waveguide CO2 laser gain: Dependence on gas kinetic and discharge properties

Using a simple rate equation approach the gas kinetic and discharge properties of waveguide CO2 lasers were examined. The dependence was calculated of the population inversion and laser small signal gain on gas pressure, gas mixture, pumping rate (discharge current), tube bore diameter, and wall temperature. At higher pressures the gain is optimized by using more helium rich mixtures and smaller bore diameters. The dependence of laser tunability on the gas kinetic properties and cavity losses was determined, it was found that for loss cavities the laser tunability may substantially exceed the molecular fullwidth at half maximum. The more helium rich gas mixtures give greater tunability when cavity losses are small and less tunability when cavity losses are large. The role of the various gases in the waveguide CO2 laser is the same as that in conventional devices, by contrast with conventional lasers, the waveguide laser transition is homogeneously broadened. The dependence of gain on gas pressure and other kinetic and discharge properties differs substantially from that predicted by scaling results from conventional low pressure lasers.

Cohen, S. C.↗

433 micron laser heterodyne observations of galactic CO from Mauna Kea

A submillimeter heterodyne radiometer, developed for astronomical applications, uses an optically pumped laser local oscillator and a quasi-optical Schottky diode mixer. The resultant telescope-mounted system, which has a noise temperature less than 4000 K (double sideband) and high frequency and spatial resolution, has been used to detect the J = 6 to 5 rotational transition of carbon monoxide at 434 micrometers in the Orion molecular clouds. The measurements, when compared with previous millimeter-wave data, indicate that the broad carbon monoxide emission feature is produced by an optically thin gas whose temperature exceeds 180 K.

Buhl, D.↗

Determination of molecular spectroscopic parameters and energy-transfer rates by double-resonance spectroscopy

The spectroscopy of small to medium-size polyatomic molecules can be extremely complex, especially in higher-lying overtone and combination vibrational levels. The high density of levels also complicates the understanding of inelastic collision processes, which is required to model energy transfer and collision broadening of spectral lines. Both of these problems can be addressed by double-resonance spectroscopy, i.e., time-resolved pump-probe measurements using microwave, infrared, near-infrared, and visible-wavelength sources. Information on excited-state spectroscopy, transition moments, inelastic energy transfer rates and propensity rules, and pressure-broadening parameters may be obtained from such experiments. Examples are given for several species of importance in planetary atmospheres, including ozone, silane, ethane, and ammonia.

Steinfeld, J. I.↗

A New Method to Correct the Electrochemical Concentration Cell (ECC) Ozonesonde Time Response and its Implications for "Background Current" and Pump Efficiency

The electrochemical concentration cell (ECC) ozonesonde has been the main instrument for in situ profiling of ozone worldwide; yet, some details of its operation, which contribute to the ozone uncertainty budget, are not well understood. Here, we investigate the time response of the chemical reactions inside the ECC and how corrections can be used to remove some systematic biases. The analysis is based on the understanding that two reaction pathways involving ozone occur inside the ECC that generate electrical currents on two very different timescales. The main fast-reaction pathway with a time constant of about 20 s is due the conversion of iodide to molecular iodine and the generation of two free electrons per ozone molecule. A secondary slow-reaction pathway involving the buffer generates an excess current of about 2 %–10 % with a time constant of about 25 min. This excess current can be interpreted as what has conventionally been considered the “background current”. This contribution can be calculated and removed from the measured current instead of the background current. Here we provide an algorithm to calculate and remove the contribution of the slow-reaction pathway and to correct for the time lag of the fast-reaction pathway. This processing algorithm has been applied to ozonesonde profiles at Costa Rica and during the Central Equatorial Pacific Experiment (CEPEX) as well as to laboratory experiments evaluating the performance of ECC ozonesondes. At Costa Rica, where a 1 % KI, 1/10th buffer solution is used, there is no change in the derived total ozone column; however, in the upper troposphere and lower stratosphere, average reported ozone concentrations increase by up to 7 % and above 30 km decrease by up to 7 %. During CEPEX, where a 1 % KI, full-buffer solution was used, ozone concentrations are increased mostly in the upper troposphere, with no change near the top of the profile. In the laboratory measurements, the processing algorithms have been applied to measurements using the majority of current sensing solutions and using only the stronger pump efficiency correction reported by Johnson et al. (2002). This improves the accuracy of the ECC sonde ozone profiles, especially for low ozone concentrations or large ozone gradients and removes systematic biases relative to the reference instruments. In the surface layer, operational procedures prior to launch, in particular the use of filters, influence how typical gradients above the surface are detected. The correction algorithm may report gradients that are steeper than originally reported, but their uncertainty is strongly influenced by the prelaunch procedures.

electrochemical concentration cell (ECC) ozonesond↗

Molecular rotational line profiles from oxygen-rich red giant winds

We have developed a radiative transfer model of the dust and gas envelopes around late-type stars. The gas kinetic temperature for each star is calculated by solving equations of motion and the energy balance simultaneously. The main processes include viscous heating and adiabatic and radiative cooling. Heating is dominated by viscosity as the grains stream outward through the gas, with some contribution in oxygen-rich stars by near-IR pumping of H2O followed by collisional de-excitation in the inner envelope. For O-rich stars, rotational H2O cooling is a dominant mechanism in the middle part of the envelope, with CO cooling being less significant. We have applied our model to three well-studied oxygen-rich red giant stars. The three stars cover a wide range of mass-loss rates, and hence they have different temperature structures. The derived temperature structures are used in calculating CO line profiles for these objects. Comparison of the dust and gas mass-loss rates suggests that mass-loss rates are not constant during the asymptotic giant branch phase. In particular, the results show that the low CO 1-0 antenna temperatures of OH/IR stars reflect an earlier phase of much lower mass-loss rate.

Justtanont, K.↗

NASA's New Laser Risk Reduction Program For Future Space Lidar Missions

NASA has been performing ground, airborne, and space-based scientific measurements since it was formed in 1958. Initial ground and airborne measurements were made with in situ instruments. By necessity, initial earth observation space-based missions were accomplished with passive remote sensing. Active microwave radar was added to the sensor repertoire in the late 1970s. A few key measurements important to NASA remain unaccomplished, however, despite the passive and radar successes. These critical measurements include space-based altimetry; and high spatial resolution profiling of aerosol properties, wind velocity, clouds, and molecular concentrations. Fortunately, a new technology, active optical radar or laser radar or lidar, has matured to the point that the last decade has seen a growing consideration of lidar for space missions. Part of the surge in consideration of lidar has been the tremendous progress in solid-state lasers fueled by advances in crystal growth quality and pump laser diode technology.

Michael J. Kavaya↗

Solar-simulator-pumped atomic iodine laser kinetics

The literature contains broad ranges of disagreement in kinetic data for the atomic iodine laser. A kinetic model of a solar-simulator-pumped iodine laser is used to select those kinetic data consistent with recent laser experiments at the Langley Research Center. Analysis of the solar-simulator-pumped laser experiments resulted in the following estimates of rate coefficients: for alkyl radical (n-C3F7) and atomic iodine (I) recombination, 4.3 x 10 to the 11th power (1.9) + or - cu cm/s; for n-C3F7I stabilized atomic iodine recombination (I + I) 3.7 x 10 to the -32nd power (2.3) + or -1 cm to the 6th power/s; and for molecular iodine (I2) quenching, 3.1 x 10 to the -11th power (1.6) + or - 1 cu cm/s. These rates are consistent with the recent measurements.

Wilson, H. W.↗

Automated Fluidics Device for Extraction and Quantification of miRNA Biomarkers From Blood

Radiation Assessment DuRing Exposure And long-Duration Spaceflight (RADREADS) demonstrates space-compatible point-of-care technology for quantitative biological monitoring of blood miRNA biomarkers in response to long-term low dose radiation exposure. This individualized monitoring approach will inform targeted treatment strategies to maximize medical resource utilization by accounting for individual susceptibility to radiation-related illnesses. As human spaceflight progresses beyond Earth’s magnetic shielding, radiation exposure poses a significant risk to astronaut health and safety. Extended operation in this environment comes with an increased risk of radiation exposure, leading to higher risks of radiation sickness, cancer, central nervous system effects, and degenerative diseases. While conventional physical dosimetry techniques capture radiation dose, individualistic susceptibility to radiation damage is varied. Multiple characteristics, including age, body weight, sex, genetics, and immune status, have been found to influence radiosensitivity (Liu et al. 2011, and Bouffler 2016). This differential response necessitates individualized monitoring and targeted treatment strategies to maximize medical resource utilization; however, a practical diagnostic platform for quantifying long-term, low dose radiation-induced tissue damage does not currently exist. MicroRNAs (miRNAs) are a class of small, non-coding RNAs that regulate gene expression by mediating the degradation of messenger RNA. The levels of particular miRNAs are influenced by biological processes such as inflammation and serve as biomarkers for a variety of conditions including cancer (Singh et al. 2017). MicroRNAs are found in various bodily fluids and are amenable to collection via liquid biopsies, providing a minimally invasive and easily quantifiable readout for a variety of radiosensitive reporters. A preliminary signature of 15 spaceflight sensitive miRNA has been identified in rodent and human studies, including miR-21-5p, miR-24-3p, miR-92a-3p, miR-17-5p, miR-16a-3p, miR-34a-3p, and miR-223-3p. These targets generally increased expression with radiation dose and linear energy transfer, though variation between individuals is not yet described. Current gaps in the field include a lack of understanding of longitudinal biological responses to long-term, low dose radiation exposure and the absence of space-compatible point-of-care technology for quantitative biological monitoring. In this body of work, we aim to develop an automated bleed-to-read system to process whole blood for the detection of miRNA biomarkers in order to monitor individualistic responses to radiation exposure. This will be achieved via separating serum (or plasma) from whole blood, followed by extraction, amplification, and quantification of the miRNA using a RT-qPCR reaction. Previously, the WetLab-2 hardware enabled execution of a RT-qPCR reaction aboard ISS; however, it is a manual system that requires crew manipulation and bulky components (Parra et al. 2017). To address these issues, automated fluid handling hardware was developed for each stage of sample preparation. Extraction of total RNA is achieved by sequentially pumping reagents through an off-the-shelf nucleic acid binding column (miRNeasy Serum/Plasma Advanced Kit, Qiagen). This approach eliminates several manual pipetting and centrifuging steps and limits the use of toxic chemicals commonly found in other sample processing techniques. The resulting elution will then be automatically dispensed for RT-qPCR analysis using a compact rotary qPCR (Mic qPCR Cycler, Bio Molecular Systems) that will improve spaceflight compatibility by removing bubbles from the detection region, another challenge highlighted by WetLab-2 (Parra et al. 2017). Efforts are also being made to simplify the RT-qPCR reaction to a 1-step air-dryable mix to improve long-term reagent stability at room temperature and reduce system complexity. By automating the RT-qPCR processes via microfluidic manipulation, RADREADS will reduce crewmember hands-on time and enable the personalized detection of radiation-induced tissue damage during long duration missions. Minimally invasive, longitudinal monitoring of individual’s response to radiation exposure will inform how the physiological system responds to long-term low dose space radiation and enables development of targeted countermeasures by the medical team. Ultimately, this portable technology will require minimal technical expertise and can also be used to monitor miRNA biomarkers associated with other diseases.

Tristen Head↗